Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Southern Railway - SR Tender

Goods
Paints and Enamels
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date18 Jun 2024
Closing Date10 Jul 2024
Tender Amount₹ 44,04,656 
Notes
Download

Costs

Summary

Salem Division -provision Of Facade Lighting For Morappur (map) And Samalpatty (sly) Station Under Amrit Bharat Station Scheme Phase-i-electrical Arrangements.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing, and Commissioning of exterior BIS registered 75W LED RGBW flood lighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum system lumen efficacy equal to or greater than 50lm/w. The luminaire shall be capable of producing dynamic colorchanging light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512 protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical as per the site requirement. Fixture with constant locking hinges for simple position control from various angles without special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burning 4 hours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/LEDNIUM/AVAGO make.DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The product should be BIS-approved with the R number mentioned on the product label. To be supported with Product test reports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for the proper working of the fixture including weatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to the competent authority for approval. After installation, assembling, and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week

6

39203

235218

... More
Supply, Installation, Testing, and Commissioning of exterior BIS registered 55W LED RGBW flood lighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum system lumen efficacy equal to greater than 50 lm/w. The luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512 protocol /Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical as per the site requirement. Fixture with constant locking hinges for simple position control from various angles without special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burning hours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/LEDNIUM/AVAGO make. 5 DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The product should be BIS-approved with the R number mentioned on the product label. To be supported with Product test reports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for the proper working of the fixture including weatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to the competent authority for approval. After installation, assembling, and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week.

2

34401

68802

... More
Supply, Installation, Testing, and Commissioning of exterior BIS registered 45W LED RGBW flood lighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum system lumen efficacy equal to or greater than 50lm/w. The luminaire shall be capable of producing dynamic colorchanging light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512 protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical as per the site requirement. Fixture with constant locking hinges for simple position control from various angles without special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burning 6 hours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/ LEDNIUM/AVAGO make. DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9.The product should be BIS-approved with the R number mentioned on the product label. To be supported with Product test reports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for the proper working of the fixture including weatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to the competent authority for approval.After installation, assembling, and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week.

15

29788

446820

... More
Supply, installation, testing & commissioning of Sky cove LED RGB flexible strip light strip 5 mtr long (1 roll) with 7.2 watt per meter with driver Model, LED strip should have 30 nos LEDs per meter through out the length with the silicon cover. The strip should have IP 68 protection and should have cover Glue Injected with 7 polyurethane. , the nominal voltage should be DC 24V, working temperature range should be between -20 deg C to +50deg c. work should be completed with necessary factory made weather proof cable, lenses and external power and data supply[if any]. suitable fixing arrangement as required complete in all respect as per direction of engineer in charge, warranty:-5 years, electrical safety class: class 1 (The work to be executed as per direction of engineer in charge at site).

22

1022

22484

... More
Supply Erection testing and commissioning of DMX signal cable / shielded Cat. 6 or better data cable shall be used for digital communication networks. Size and quantity of cable shall be as per site requirement and as directed by SSE Incharge. Copper lugs, glands of proper size shall be used for connections.

506

263

133078

... More
Supply Erection testing commissioning of male-Female sets for connecting DMX cable of RGB 9 fitting with 5-pin DMX XLR connectors for lighting cables and Effects,Set includes one male connector and one female connector, Gold pins for optimum signal transfer,Stranded Tinned Copper Conductors,PVC Jacket, Length - 6 inches.

224

773

173152

... More
Supply, Installation, Testing and Commissioning of DMX Splitter with Input Voltage range : 100- 240V 50-60Hz AC, Power Consumption 4W/8W max. Housing is made of polycarbonate with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature -17°C to +55°C, 5 Output with 5pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 5 DMX output per universe/10 DMX output for double rack versions. The output terminals of Splitters are optically 10 isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment. All test reports and technical data sheets to be submitted to the competent authority for approval. After installation, assembling and commissioning contractor should ensure that all parts of the DMX splitter are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the DMX splitter to be done in the presence of Site Engineer for a minimum period of 1 week. The make of the cable used shall be approved by Railways.

4

73062

292248

... More
Supply, Installation, Testing and Commissioning, of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-12V DC and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & 11 Ethernet. DMX controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It must have sufficient DMX512 RJ45 ports and sufficient RS-232 - pin serial ports. It must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presets and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. Facade lighting product and its driver should be compatible with DMX controller. To be provided with IP 66 polycarbonate enclosure. (Warranty Period of 5 years). All test reports and technical data sheets to be submitted to the competent authority for approval. After installation, assembling and commissioning contractor should ensure that all parts of the DMX controller are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the DMX controller to be done in the presence of Site Engineer for a minimum period of 1 week

2

177372

354744

... More
Supply at Site fixing testing and commissioning of 9W landscape Bollard of height 1m made up of Graphite grey powder-coated GI Pipe housing. Sample to be submitted for approval before supply, The luminaire shall have opal acrylic diffuser with IP65 protection is fixed in a die-cast aluminium base for pleasant light output LEDs mounted on a die-cast aluminium base Luminaire is available with colour temperature: Warm White 12 (WW):3000K 250K Luminaire is wired with an inbuilt driver with 4.5kV surge protection device, having constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection. And Installation of the above bollard fixtures complete with pole of height 1m or above compatible for the above bollard with terminal connections & mounting accessories suitable and concrete foundation alongwith wiring by 3 C x 1.0 sq.mm PVC insulated & sheathed round flexible copper cable in an approved manner as directed section Engineer in charge at site

20

3275

65500

... More
Design, Supply and fixing of aesthetically designed IP65 type LED Post Top Lantern of 45Watts with symmetrical light distribution, spun aluminium top cover landscape luminaire with high power LEDs as light 13 source. Sample to be submitted for approval before supply, luminaire is wired with inbuilt driver with 4.5kV surge protection device, Constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection duly Installation of above bollard fixtures complete with suitable concrete foundation and wiring by 3 C x 1.0 sq.mm PVC insulated & sheathed round flexible copper cable in an approved manner as directed by section Engineer in charge at site.

20

9009

180180

... More
Supply Erection testing and commissioning of LED Aesthetically designed, decorative strip light for decorative & cove lighting applications 22W /5 Mtrs with necessary driver,3M adhesive tape on the back for fixing per site condition as directed by SSE Incharge at site

8

269

2152

... More
Supply and laying of 4CX2.5sqmm XLPE insulated armoured copper cable suitable for Rated Voltage of 1100V grade and conforming to IS 7098 part I with amendment number 1 2 and 3 reaffirmed 2005 or 15 latest and IS 8130 with latest amendments and with ISI marking. Cable shall be supplied by the OEM or their authorized dealer duly producing dealership certificate Cable shall be tested by CPRI ERDA NABL or any other laboratories recognized by the Govt. of India test certificate and OEM warranty certificate shall be produced by the supplier along with the supply of the cable

770

153

117810

... More
Supply and termination of Polyamide cable glands & copper lugs suitable for terminating 4C x 2.5 sqmm XLPE Insulated armoured copper cable. Cable Glands - Cable shall be terminated using double compression type cable glands. Testing requirements of Cable glands shall conform to BS:6121 and gland shall be of robust construction capable of clamping cable and cable armour (for armoured cables) firmly without injury to insulation. Cable glands shall be made of heavy duty brass machine finished and nickel chrome plated. Thickness of plating shall not be less than 10 micron. All washers and hardware shall also be made of brass with nickel chrome plating Rubber components shall be of neoprene or better synthetic material and of tested quality. Cable glands shall be suitable for the sizes of cable supplied/erected. Cables to be terminated - Unarmored HT power cables, Armoured and Unarmored LT power cables, unarmored Control cables and unarmored Screened (instrumentation) cables 2. Cable Lugs - Cable lugs for power cables shall be tinned copper solderless crimping type suitable for copper compacted conductor cables. Cable lugs and ferrules for control cables shall be tinned copper type. All power cable lugs shall be Single hole type. The cable lugs for control cables and screened/instrumentation cables shall be pin type and shall be provided with insulating sleeve. Cable lugs and ferrule shall conform to DIN standards.

108

118

12744

... More
Supply Erection testing commissioning of 14 SWG GI Earth wire including binding with 16 SWG GI 17 wire complete Hard drawn GI, 14 SWG shall be erected at site as per requirement and is should be bind with 16 SWG GI wire in proper manner, nuts check nuts to be fixed from underside the bottom bracket with one set of nut on the top and other set of at the bottom to keep the wire in position for supporting/ terminating of the guard wire.The work shall be done in an approved manner as per the site conditions and instructions of field Engineer

770

4

3080

... More
Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRP JB (IP 65) Size:139x119x70 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm XLPE armoured cable,The junction box be 2.7 mm thick with electrically insulated body shock proof, connector leads and control equipped 18 with 1 nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight. The junction box shall be vermin proof having rubber bushes at cable entry. The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size. Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer

88

908

79904

... More
Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRP JB (IP 65) Size:260x210x116 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm armoured cable & housing 1 driver,The junction box should be 2.7 mm thick with electrically insulated body shock proof, connector leads and 19 control equipped with 1 nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight. The junction box shall be vermin proof having rubber bushes at cable entry. The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size. Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer.

20

1119

22380

... More
Supply fitting fixing of 25 watts all in one solar street light (LED based) consist of white LED 20 luminaire (LED + Driver) rating as per configuration along with Solar PV modules and LiFePO4 battery of given capacity, necessary control electronics, interconnecting wires/ cables, module mounting structures, etc. to operate from dusk to dawn. The tenderer must provide the LED street light that conforms to the technical specification As per annexure I

20

21868

437360

... More
Supply of MS work of miscellaneous size and for cable tray etc including painting complete

100

71

7100

... More
Fabrication fixing and erection of MS work of miscellaneous size,riveted, bolted or welded in built 22 up sections including cutting, grinding and straightening, drilling, riveting, handling, hoisting and fixing in position etc. including applying a priming coat of approved steel primer etc. and duly painted with fine finish with contractors steel and materials. The work shall be done as per the site requirement in an approved manner and as per the instructions of field supervisor

100

10

1000

... More
Supply and concealing of rigid PVC conduits of 25 mm Dia (IVORY colour) confirming to IS 23 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0mm along with the all accessories and including cutting the wall/ceiling/chipping or elsewhere and making good the same as directed by Engineer in charge at site

125

50

6250

... More
Supply and fixing of PVC conduits (IVORY colour) of 25 mm Dia confirming to IS:9537/P3/1983 or latest(ISI Marked) with wall thickness not less than 2.0 mm along with, all accessories on wall surfaces and clamped at regular intervals, as directed by Engineer in charge at site.

770

60

46200

... More
Supply and wiring (Single phase) including termination by using 2 Nos. of 4.0 sq.mm PVC insulated 25 FRLS type flexible copper cable conforming to IS.No:694, 1100 V grade with 1 No. of 14 SWG tinned copper wire/4.0 sq.mm flexible copper cable through the PVC pipe already laid.Color coding shall be followed as directed by Engineer incharge at site. (2 Nos. of 4.0 Sq.mm Copper cable and 1 No. of 14 SWG tinned copper wire shall be taken as 1 Mtr. for measurement purpose).

45

156

7020

... More
Supply and wiring of 2 Nos. of 2.5sqmm PVC insulated flexible copper wire & 1 No. of 1.5 Sq.mm 26 PVC insulated multi strand copper wire including supply and fixing of PVC conduit/casing and capping with all accessories like round block, ceiling rose, flexible wire for connecting lights,fan fittings etc as per specification. (2 Nos. of 2.5 Sq.mm Copper cable and 1 No. of 1.5 Sq.mm PVC insulated multi strand copper wire shall be taken as 1 Mtr. for measurement purpose). PVC conduit/casing and capping to be used as per site condition.

140

130

18200

... More
Supply, erection and testing of L.T. Earthing arrangements duly stenciling of Earth Pit No., resistance value, date etc., as per Drg. no. CEE/CN/MS/16-2004, including supply and laying of earth continuity wire GI, 6 SWG wire of required length and as directed by Engineer incharge at site.

4

5800

23200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.