Southern Railway Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Southern Railway - SR Tender
Electrical and Electronics
Electrical Works
Ireps
Opening Date19 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 37,51,064
Costs
EMD
₹ 75,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
SA-E16-2024-25-W1-SALEM DIVISION-ELECTRICAL/SOUTHERN RLYTender No
SA-E16-2024-25-W1Tender Authority
Southern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and provision of mass concrete for platforms or elsewhere with 1:3:6 ratio using 20 mm blue metal complete in a manner as directed by the Section Engineer in charge at site.
15
6150
92250
... More
Supply and fixing of Cable encasing pipe of 'B' class GI pipes 50mm Dia including one number of clamp made out of MS flat of 40mm x 6mm size, one per meter length of pipe and cable sealing compound units open end where ever required as directed by Engineer in charge at site.
50
650
32500
... More
Labour Charges for Laying of 50 mm Dia PE 63,PN 6 type HDPE pipes in the excavated 6 trench, on walls or on platform shelter etc., including suitable fixing arrangement complete in a manner as directed by Section Engineer-in-charge at site. (Note: Required HDPE Pipe will be supplied by Railways.)
600
39
23400
... More
Labour Charges for Laying of 110 mm Dia PE 100 PN 6 type HDPE pipes in the 7 excavated trench, on walls or on platform shelter etc., including suitable fixing arrangement complete in a manner as directed by Section Engineer-in-charge at site. (Note: Required HDPE Pipe will be supplied by Railways.)
1100
50
55000
... More
Supply and laying of 6 SWG GI wire along with the LTUG Cable, for earth continuity 8 confirming to IS 12776 complete in an approved manner and as directed by Engineer in charge at site.
1700
31
52700
... More
Supply and fixing of cable route indicator made of cast iron plate type as per specification in drawing No. CEE/CN/MS/11-2004 complete in an approved manner and as directed by Engineer in charge at site.
35
500
17500
... More
Labour charges for Laying, testing and commissioning of LTUG power cables of size 10 upto and including 50 sq.mm in the excavated trench/on Building walls/Sheds/Shelters etc., as per IS No:1255 complete in an approved manner and as directed by Engineer in charge at site. Note: LTUG Cables only will be supplied by Railways.
700
30
21000
... More
Labour charges for Laying, testing and commissioning of LTUG power cables upto and 11 including the size of above 50 sq.mm and upto 240 sq.mm in the excavated trench/on Building walls/Sheds/Shelters etc., as per IS No:1255 complete in an approved manner and as directed by Engineer in charge at site. (Note: Required LTUG Cable will be supplied by Railways.)
1110
50
55500
... More
Fabrication, Supply and fixing of Cable fixing clamps of suitable sizes made out of MS flat of 40mm x 6mm size including painting suitable for clamping/fixing of LTUG cables on the walls/ building/ sheds/ shelters etc., using bolts and nuts as desired by Section Engineer-in-charge at site.
150
68
10200
... More
Supply and concealing of rigid PVC conduits of 25 mm Dia confirming to IS 13 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0mm along with the all accessories and including cutting the wall/ceiling/chipping and re plastering the same as good condition as directed by Engineer in charge at site.
1497
50
74850
... More
Supply and fixing of PVC conduits (IVORY colour) of 25mm Dia confirming to 14 IS:9537/P3/1983 or latest(ISI Marked) with wall thickness not less than 2.0 mm, all accessories on existing wall/stanchion/portal/column and clamped at regular intervals as directed by Engineer in charge at site.
199
60
11940
... More
Supply and concealing of rigid PVC conduits of 20 mm Dia confirming to IS 15 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0mm along with the all accessories and including cutting the wall/ceiling/chipping and re plastering the same as good condition as directed by Engineer in charge at site.
379
42
15918
... More
Supply and fixing of PVC conduits (IVORY colour) of 20mm Dia confirming to 16 IS:9537/P3/1983 or latest(ISI Marked) with wall thickness not less than 2.0 mm, all accessories on existing wall/stanchion/portal/column and clamped at regular intervals as directed by Engineer in charge at site.
455
48
21840
... More
Supply and wiring by 4 nos of 10.0 sq.mm (3 phase) PVC insulated FRLS type flexible 17 copper cable conforming to IS.No:694,1100 V grade with 1 no of 14 SWG tinned copper wire/10.0 sq.mm flexible copper cable through PVC conduit pipe already fixed. The Color coding shall be followed as directed by Engineer in charge at site(4 nos of 10.0 sq.mm copper cable and 1 no of 14 SWG tinned copper shall be taken as 1 Mtr for measurement purpose)
220
789
173580
... More
Supply and wiring including termination by 3 nos. of 6 sqmm PVC insulated fire 18 retardant low smoke (FRLS) flexible copper cable conforming to IS. No: 694, 1100 V grade through the existing PVC pipe already laid, Color coding shall be followed as directed by Engineer in charge at site(3 nos. of 6 sqmm copper cable wire shall be taken as 1 m for measurement purpose)
780
213
166140
... More
Supply and wiring including termination by 3 nos. of 4 sqmm PVC insulated fire 19 retardant low smoke (FRLS) flexible copper cable conforming to IS. No: 694, 1100 V grade through the existing PVC pipe already laid, Color coding shall be followed as directed by Engineer in charge at site (3 nos. of 4 sqmm copper cable wire shall be taken as 1 m for measurement purpose)
380
167
63460
... More
Supply and wiring including termination by 3 nos of 2.5 sqmm PVC insulated fire 20 retardant low smoke (FRLS) flexible copper cable conforming to IS.No:694,1100 V grade through the existing PVC pipe already laid,including one Green color wire for earth.(3 nos of 2.5 sqmm copper cable wire shall be taken as 1m for measurement purpose)
1260
125
157500
... More
Supply and wiring (single phase)including termination by 2 runs of 1.5 sqmm FRLS PVC insulated flexible copper cables for phase and neutral and 1 run of 1.5 sqmm thermostat pilot lamp with timer etc in an approved manner and as directed by Engineer in charge at site.
952
120
114240
... More
Supply and wiring including termination for lights, fans and calling bell points etc. by 3 22 nos. of 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) flexible copper cable, conforming to IS. No: 694, 1100 V grade, and 1 no of 14 SWG tinned copper wire through existing PVC pipes already laid including, three plate ceiling rose and other accessories. Color coding shall be followed as directed by Engineer in charge at site.(Up to 3 m long points).
36
343
12348
... More
Supply and wiring including termination for lights, fans and calling bell points etc. by 3 23 nos. of 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) flexible copper cable, conforming to IS. No: 694, 1100 V grade,and 1 no of 14 SWG tinned copper wire through existing PVC pipes already laid including, three plate ceiling rose and other accessories. Color coding shall be followed as directed by Engineer in charge at site.(Above 3 m and up to and including 7 m long points).
34
485
16490
... More
Supply and wiring including termination for lights, fans and calling bell points etc. by 3 24 nos. of 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) flexible copper cable, conforming to IS. No: 694, 1100 V grade, and 1 no of 14 SWG tinned copper wire through existing PVC pipes already laid including, three plate ceiling rose and other accessories. Color coding shall be followed as directed by Engineer in charge at site (Above 7 m long points).
20
525
10500
... More
Supply at site, fixing, testing and commissioning of 12 way modular switch box with concealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the 25 following works at the location where the boxes are to be fixed: (1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
20
450
9000
... More
Supply at site, fixing, testing and commissioning of 08 way modular switch box with concealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the 26 following works at the location where the boxes are to be fixed: (1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
6
350
2100
... More
Supply at site, fixing, testing and commissioning of 06 way modular switch box with concealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the 27 following works at the location where the boxes are to be fixed:(1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
53
245
12985
... More
Supply at site, fixing, testing and commissioning of 04 way modular switch box with concealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the 28 following works at the location where the boxes are to be fixed:(1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
8
210
1680
... More
Supply at site, fixing, testing and commissioning of 03 way modular switch box with concealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the 29 following works at the location where the boxes are to be fixed: (1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
8
146
1168
... More
Supply at site, fixing, testing and commissioning of 02 way modular switch box withconcealed metallic flush box as base, mounting plate (modular white plate) confirming to latest IS specification complete in an approved manner. The boxes are to be fixed firmly after doing the following works at the location where the boxes are to be fixed: (1) Required opening for fixing the modular metallic switch box to be made by cutting the wall without causing major damage to wall (2) Unwanted projections are to be chipped and the wall surface is to be made even, (3) The wall surface is to be plastered to the present level of the wall surrounding the board. (4) The gap between box and wall surface to be filled with suitable filling material.
13
143
1859
... More
Supply at site, fixing, testing and commissioning of 1 way 6A modular switch 31 confirming to latest IS specification complete on the appropriate modular switch boxes already erected including internal wiring connection in the modular switch box complete in an approved manner as per the section in charge's instruction.
327
68
22236
... More
Supply at site, fixing, testing and commissioning of modular type socket 6Asocket, 32 2/3Pin, flush confirming to latest IS specification complete on the appropriate modular boxes already erected including internal wiring connection and earth connection to earth terminal in switch board by 1.5sqmm PVC insulated single core copper conductor complete in an approved manner as per the section in charge's instruction.
156
105
16380
... More
Supply at site, fixing, testing and commissioning of 1 way 16A modular switch 33 confirming to latest IS specification complete on the appropriate modular switch boxes already erected including internal wiring connection in the modular switch box complete in an approved manner as per the section in charge's instruction.
18
105
1890
... More
Supply at site, fixing, testing and commissioning of modular type socket 16Asocket, 34 5/3Pin, flush confirming to latest IS specification complete on the appropriate modular boxes already erected including internal wiring connection by 4.0sqmm PVC insulated single core copper conductor and earth connection to earth terminal in switch board in an approved manner as per the section in charge's instruction.
18
140
2520
... More
Supply at site, fixing, testing and commissioning of Dummy plate suitable for modular box mentioned in the schedule No;25-30 wherever required with necessary fixing by suitable screws & nuts in approved manner as directed by the Engineer in-charge at site.
13
25
325
... More
Fixing,testing and commissioning of 20 watts LED light. Fitting shall be fixed with 36 Round block with patterns on side wall/ceiling with TW round blocks including wiring by 3 C x 1.0 sqmm PVC insulated & sheathed round flexible copper cable in an approved manner as directed by the Engineer in charge at site. (Note:Necessary LED Light fittings will be supplied by Railways)
21
177
3717
... More
Supply Fixing testing and commissioning of Surface mounted type 15W LED Light fitting rated voltage 230 V at 50 Hz AC in conformity to IS:10322-5-2(2012). The Fitting shall be fixed 37 on ceiling including wiring by 3 C x 1.0 sqmm PVC insulated & sheathed round flexible copper cable in an approved manner as directed by the Engineer in charge at site. The Warranty for the LED Light fitting will be 5 years and the payment condition will be followed as per Special condition-II para no:31.
100
702
70200
... More
Supply Fixing testing and commissioning of Recess mounted type 20W Square type 1x1 LED polycarbonate Light fitting rated voltage 230 V at 50 Hz AC with IP 20 in conformity to 38 IS:10322/part 5/sec-2/2012 and IS 16107 (Part 2/Sec 1) : 2012 for Recess type, with higher efficacy >/=140 Lm/Watt.The Fitting shall be fixed on ceiling including wiring by 3 C x 1.0 sqmm PVC insulated & sheathed round flexible copper cable in an approved manner as directed by the Engineer in charge at site. The Warranty for the LED Light fitting will be 5 years and the payment condition will be followed as per Special condition-II para no:31.
100
935
93500
... More
Fixing, testing and commissioning of BLDC fan in the existing fan hook including wiring with 3 C X 1.0 sq.mm PVC insulated & sheathed copper flexible cable in an approved manner and as directed by Engineer in charge at site. (Note: BLDC fan only will be supplied by Railways.)
50
260
13000
... More
Fixing, testing and commissioning of Exhaust fan including wall opening, fixing of 40 frame and plastering as required for housing. Exhaust fan including wiring with 3C x 1.0 sq.mm PVC insulated & sheathed copper flexible cable. Note: Necessary Exhaust fan only will be supplied by Railways.
12
690
8280
... More
Fixing, testing and commissioning of wall mounting type fan 450mm sweep in the existing wall/Stanchion/pillar by using screws, nuts, washers etc in an approved manner and can be fixed at suitable safe height as directed by Engineer in charge at site. Note: Necessary wall mounting fan only will be supplied by Railways.
48
397
19056
... More
Supply, fixing testing and commissioning of Metal Clad Plug and socket enclosure 20A DP-1 No with i) metal clad plug 20A -1 No ,ii)Metal clad socket 20A -1 No, iii)6-32A DP RCCB-1 No complete in an approved manner and as directed by the Engineer-in-Charge at site.
10
3152
31520
... More
Supply and fixing of 5 star rated 9W,B22 type LED Lamp with Minimum Lumens output 43 of 100 Lumens/Watts including supply and fixing of suitable batten /angle holder including all connected materials to be fixed in an approved manner and as directed by Engineer in charge at site. The Warranty for the LED Light fitting will be 5 years and the payment condition will be followed as per Special condition-II para no:31.
28
165
4620
... More
Supply, Fixing, testing and commissioning of 10W LED type Bulk Head fitting ,IP65 luminaires with opal diffuser suitable fixing arrangement on the wall duly supplying supporting 44 arrangements etc., and wiring from ceiling rose to light fitting by 3C x 1.0 sqmm PVC insulated and sheathed fire retardant low smoke (FRLS) flexible copper cable complete to be done by contractor in an approved manner as directed by the Engineer in charge at site. The Warranty for the LED Light fitting will be 5 years and the payment condition will be followed as per Special condition-II para no:31.
28
720
20160
... More
Supply and installation of Cable tray of Size 300mmx50mm height using50x50x6mm 45 angles of perforated cable trays with perforation not more than17.5% fabricated out of Mild steel conforming to IS 2062/1079 and Hot dip galvanized as perIS2629/4759(galvanizing not less than80 microns) in convenient sections, jointed with connectors complete as per the detailed specification enclosed in Annexure and as desired by the Engineer-in charge at site.
150
700
105000
... More
Supply, Fixing, testing and commissioning of street light LED fitting 40 W on octagonal poles/wall with Bracket made out of suitable GI pipe (B class) having IP65 protection The fitting 46 should be operated on 100-285V, 50Hz, pf-.95 cool white colour, constant current LED driver with THD of less than 10%, beam angle 120degree, lumens per watt minimum100, The fitting should be fixed with suitable fixing arrangement on the wall duly supplying supporting arrangements complete in an approved manner and as directed by Engineer in charge. The Warranty for the LED Light fitting will be 5 years and the payment condition will be followed as per Special condition-II para no:31.
15
2000
30000
... More
Supply and erection of 5m long, GI, octagonal lamp post with one meter length single arm. The price offered shall be inclusive of the cost of pole(5Mtr), bracket/top cover, arm, foundation bolt and base plate. The octagonal poles shall be designed to withstand the maximum wind speed asper IS 875. The bracket shall be suitable for the fixing the canopy of water tight lamp fitting directly. The poles shall be manufactured from special HT steel confirming to gradeS355JO having 3 mm thick. The pole shall be of continuously tapered with single longitudinal welding. The pole shall have a minimum dia of 130mm at bottom and 70 mm at top. The welding shall be done by submerged Arc welding process. The pole shall be provided with a base plate of size200mm X 200mm X 12mm of Fe 410grade steel confirming to IS 226/IS2062 with provision for fixing foundation bolts. This base plate shall be fillet welded to the pole shaft from inside and outside. The pole shall be provided with 4 numbers of foundation bolt confirming to EN-8 grade of 16mmdia. The foundation bolt shall have minimum length of 600mm. The pole with base shall be hot dip galvanized both internally and externally having uniform thickness not less than 70microns. Hot dip galvanizing shall be done after fabrication in single dipping method. The galvanization shall be done as per IS 2629 / IS 26336/IS4759. The pole shall be fabricated in single section. Section having circumferential joints will be rejected. The pole shall be provided with a suitable arrangement for fixing terminal box inside the pole. The terminal box shall be protected with500 mm long reinforced and weatherproof door. The door shall be provided with internal locking arrangement and with chain arrangement and gasket. The pole shall be manufactured in anISO 9001, 2000 & ISO 14001 certified fabrication unit to ensure consistent quality. The pole foundation shall be erected strictly as per pole manufactures design, including excavation of earth, supply of concrete of all types, provision of reinforcement steel rods of sizes including fabrication and binding and supply and insertion of PVC pipe of 63 mm OD at 1.0 m per foundation. This also includes provision of foundation bolts already supplied in the required PCD.The price offered shall be inclusive of the cost of erection charges. Octagonal poles shall be erected to plumb on the concrete foundation already provided using 'J'foundation bolts already supplied and embedded in the concrete foundation. This includes assembly of all the bracket arms supplied as per standard. The technical particulars shall be obtained from the manufacturer showing the compliance of the specification and documentary proof towards certification of ISO 9001- 2000/ISO14001 for the manufacturing unit shall be submitted for obtaining the approval. The octagonal post shall be supplied only after obtaining the approval. (Note: Supply of octagonal pole is inclusive of pole, bracket arms, base plate, foundation bolts, required fasteners for assembling, terminal block with rewirable fuse units etc. Cable gland to be provided inside the pole is covered under different item of schedule)
-
-
47
... More
Wiring of light points through octagonal pole with 3 core 1.5 sq.mm wire. The price offered shall be inclusive of the cost of 1.5 sq mm wire PVC insulated copper cable three numbers one for phase, one for neutral and one for earth or 3 core 1.5 sq mm PVC insulated copper cable 48 confirming to IS 694 for extending the power supply from the terminal box to the lamps erected on the pole. No intermediate joints will be permitted in copper cable. The price offered shall be inclusive of the cost of labour charges required for wiring the lamp post. If the pole is fitted with double arm arrangement for providing two light fittings, Two sets of cable shall be provided. Measurement will be taken as two for double arm lamp post whereas measurement for this item will be counted as one when pole is equipped with single light fitting.
10
675
6750
... More
Fabrication, supply, fixing and commissioning of outdoor type powder coated MS cable end termination box made of 14 SWG sheet steel of size not less than 400 x 300 x 200 mm as 49 directed by Engineer in charge at site.The looping box shall consist of 100A/63A,4way terminal connectors and shall be fixed on suitable 6mm thick Hylum sheet with proper cable looping/terminal connections. The loop box shall have back clamps of suitable size for fixing at wall/Lamp post/Stanchion.
10
5625
56250
... More
Supply and fixing of IP66 class powder coated metallic cable looping box of 250 x 300 50 x 150 mm size made of CRCA draw quality sheet steel 1.2mm thickness similar to BCH make BIL- 60020 with suitable fixing arrangement on wall/structures.The rate includes provision of hylum sheet of suitable size and 1 no of 100A 4 way terminal connectors and 2 nos of cable glands od suitable size.
20
4018
80360
... More
Supply, erection and testing of L.T. Earthing arrangements duly stenciling of Earth Pit 51 No., resistance value, date etc., as per Drg. no. CEE/CN/MS/16-2004, including supply and laying of earth continuity wire GI, 6 SWG wire of required length and as directed by Engineer in charge at site required.
30
5800
174000
... More
Shifting of 20 Mtr High mast from one place to other place, Overhauling, Servicing, Re- erection and commissioning of released High mast Tower with all complete accessories along with 52 Foundation for the high mast. Foundation as per general specifications enclosed in the Drawing III. The complete job includes:- 1. Dismantling, Re-erection & commissioning of High Mast. 2. Repairing of lifting & lowering units of High Mast. 3. Maintenance, Repair, greasing & oiling of gear box. 4. Repair and maintenance of lighting circuit of the flood lights. 5. Lubrication of the steel ropes and tightening of all bolts and nuts. 6. Lubrication of the chain of the electric unit. Chain to be changed if required and shall be supplied by the contactor. 7. Checking that the cable has a perfectly intact sheath and when the crown is lowered it has not to be stretched but very soft. Any electric connections not well executed or that are worn out, will be repaired by the contactor with supply of cable and other materials., The maintenance operations must be performed in favorable weather conditions (no wind). The work of dismantling and re-erection of High Mast shall be done in close co- ordination with DEE/G/SA authorized representative. The re erection shall be done at locations as indicated by DEE/G/SA authorized representative which includes transportation also. All materials, equipment's & labors required shall be supplied by the contractor.
1
144223
144223
... More
Fabrication, Supply, Erection, Testing, Commissioning of cubical type panel MCCB DB, back to wall type with the following switch gear & indication accessories, (1)1 number of 630 amps FP MCCB (Adjustable thermal & fixed Magnetic)with 50 kA breaking capacity as incomer with (2)FP- 400 amps MCCB (Adjustable thermal & fixed Magnetic) with 50 KA Breaking capacity -2 Nos, (3)FP- 125 53 amps MCCB (Fixed thermal & fixed Magnetic) with 50 KA Breaking capacity-2 Nos,(4) FP-100 amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-4 Nos,(5)FP-63Amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-3 Nos (6)32A FP MCCB-3nos (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity as outgoing, Including copper bus bar of sizes, measuring/indicating devices, etc as per the detailed specification enclosed in Annexure - II and as instructed by Engineer-in-charge at site.(Substation Essential MCCB DB Panel)
1
235225
235225
... More
Fabrication, Supply, Erection, Testing, Commissioning of cubical type panel MCCB DB, back to wall type with the following switch gear & indication accessories, (1)1 number of 400 amps FP MCCB (Adjustable thermal & fixed Magnetic) with 50 kA breaking capacity as incomer with (2)FP-200 amps MCCB (Fixed thermal & fixed Magnetic) with 35 KA Breaking capacity -2 Nos, (3)FP- 125 amps 54 MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-2 Nos,(4) FP-100 amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-2 Nos,(5) FP-63Amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-3 Nos (6)32A FP MCCB-3 nos (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity as outgoing, Including copper bus bar of sizes, measuring/indicating devices, etc as per the detailed specification enclosed in Annexure - II and as instructed by Engineer-in-charge at site.(Substation Non- Essential MCCB DB Panel).
1
180032
180032
... More
Fabrication, Supply, Erection, Testing, Commissioning of cubical type panel MCCB DB, back to wall type with the following switch gear & indication accessories, (1)1 number of 400 amps FP MCCB (Adjustable thermal & fixed Magnetic)with 50 kA breaking capacity as incomer with (2)TP-250 amps MCCB (Fixed thermal & fixed Magnetic) with 50 KA Breaking capacity -1 Nos, (3)TP- 160 amps 55 MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-4 Nos,(4) TP-125 amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-7 Nos,(5)TP-63AmpsMCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-2 Nos (6)32A TP MCCB-2 nos (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity as outgoing, Including copper bus bar of sizes, measuring/indicating devices, etc as per the detailed specification enclosed in Annexure - II and as instructed by Engineer-in-charge at site.(Switch Room Essential MCCB DB Panel)
2
184442
368884
... More
Fabrication, Supply, Erection, Testing, Commissioning of cubical type panel MCCB DB, back to wall type with the following switch gear & indication accessories, (1)1 number of 200 amps FP MCCB (fixed thermal & fixed Magnetic)with 50 kA breaking capacity as incomer with (2)TP-100 amps 56 MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity -3 Nos, (3)TP- 63 amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-3 Nos,(4) TP-32 amps MCCB (Fixed thermal & fixed Magnetic) with 25 KA Breaking capacity-4 Nos as outgoing, Including copper bus bar of sizes, measuring/indicating devices, etc as per the detailed specification enclosed in Annexure - II and as instructed by Engineer-in-charge at site.(Switch Room Non Essential MCCB DB Panel)
2
92714
185428
... More
Supply at site, erection, testing & commissioning of vertical Flush/wall mounting type , powder coated sheet steel , TPN MCB 4 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 63 amps FP MCCB (fixed thermal and fixed magnetic) with 25 KA breaking capacity, as incoming control with 08 Nos. of 6-32 amps SP MCBs with 10 KA 57 breaking capacity as outgoing control, including internal wiring by suitable wire and incoming cabletermination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.
1
14596
14596
... More
Supply at site, erection, testing & commissioning of vertical flush/ wall mounting type , powder coated sheet steel , TPN MCB 4 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 63 amps TPN MCB with 10 KA breaking capacity , as incoming control with 12 Nos. of 6-32 amps SP MCBs with 10 KA breaking capacity as outgoing 58 control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner. (Non-essential Good shed)
1
5842
5842
... More
Supply at site, erection, testing & commissioning of Horizontal flush/ wall mounting type , powder coated sheet steel , SPN MCB 12 Way distribution board phosphatised and powder coated, single door with supply and fixing of 1 Nos. of 40 amps DP RCBO with 10 KA breaking capacity , as incoming control with 08 Nos. of 6-32 amps SP MCBs with 10 KA breaking capacity as 59 outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Essential)
16
6030
96480
... More
Supply at site, erection, testing & commissioning of Vertical flush/ wall mounting type , powder coated sheet steel , TPN MCB 4 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 160 amps FP MCCB (fixed thermal and fixed magnetic) with 25 KA breaking capacity, as incoming control with 12 Nos. of 40 amps SP MCBs with 10 KA 60 breaking capacity as outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Essential)
3
22014
66042
... More
Supply at site, erection, testing & commissioning of Vertical flush/wall mounting type , powder coated sheet steel , TPN MCB 4 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 100 amps FP MCCB (fixed thermal and fixed magnetic) with 25 KA breaking capacity, as incoming control with 08 Nos. of 6-32 amps SP MCBs with 10 KA 61 breaking capacity as outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Non-Essential)
3
15240
45720
... More
Supply at site, erection, testing & commissioning of Horizontal flush/wall mounting type , powder coated sheet steel , SPN MCB 12 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 32 amps DP RCBO with 10 KA breaking capacity, as incoming control with 08 Nos. of 6-32 amps SP MCBs with 10 KA breaking capacity as 62 outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Non-Essential)
8
5341
42728
... More
Supply at site, erection, testing & commissioning of Vertical flush/wall mounting type , powder coated sheet steel , TPN MCB 8 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 125 amps FP MCCB (fixed thermal and fixed magnetic) with 25 KA breaking capacity as incoming control with 14 Nos. of 6-32 amps SP MCBs with 10 KA breaking capacity as outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Essential)
2
18677
37354
... More
Supply at site, erection, testing & commissioning of Vertical flush/wall mounting type , powder coated sheet steel , TPN MCB 8 Way distribution board phosphatised and powder coated, double door with supply and fixing of 1 Nos. of 100 amps FP MCCB (fixed thermal fixed magnetic) with 25 KA breaking capacity, as incoming control with 13 Nos. of 6-32 amps SP MCBs with 10 KA 64 breaking capacity as outgoing control, including internal wiring by suitable wire and incoming cable termination using suitable terminal block with suitable cable gland, earthing / neutral din channel complete with all accessories duly making necessary opening on the wall and masonry work for controlling power/lighting/fan circuits in each building in an approved manner as directed by the section in charge at site.. Note: 1.Bi-metallic washers must be provided for AL & Cu joints and for others GI bolts, Nuts & washers must be used. 2.Cable termination shall be using GI bolts & nuts with flat and spring washers &lugs invariably. 3. Board shall be fixed in concealed manner.(Non-Essential)
1
18773
18773
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%