Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Mar 2025
Closing Date2 Apr 2025
Tender Amount₹ 57,00,000
Costs
EMD
₹ 38,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Drama Stage In Gghss At Thimiri
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_536214_1Bid Award Id
ViewTender No
26/VLR-CLE/24-25/11.03.2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and filling of conveyed Gravel by lorry in basement filling including stacking for premeasurement, conveyance loading and unloading charges and all other incidential charges and including filling laying watering and consolidating etc., complete as directed by the dept., Officers and complying with standard specification.
114
-
-
... More
Supplying and filling in foundation, basement, etc with filling Crushed Stone Sand (M-sand) and in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
51
-
-
... More
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation and Flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
27
-
-
... More
Brick work in Cement Mortar 1:6 (One Cement and Six M-Sand) using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" including neat finishing, curing, etc., complete complying with standard specifiction.
-
-
-
... More
For Foundation and Basement
30.5
-
-
... More
For Superstructure In Ground Floor
25
-
-
... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
207
-
-
... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
7
-
-
... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
98.5
-
-
... More
Providing and laying in position, Standardised Concrete Mix M-20 Grade using M-Sand in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of M-sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
... More
For Foundation and Basement
52.5
-
-
... More
For Superstructure In Ground Floor
4
-
-
... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
51
-
-
... More
Paving the floor with best approved quality fine polished Kota stone slabs of size above 600 x 600 of 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
79
-
-
... More
Paving with hydraulically pressed cement concrete paver block with pattern design of 50% colour and 50% Plain of 83 mm of approved quality and colour, over the sand filling to full depth of slab perfectly and neat finishing the joints, compressing with vibrator. The rate shall be inclusive of cost of paver block, taxes, incidental charges, transportion charges and labour charges for fixing, neat finishing the joints as directed by the departmental officers etc., complete complying with standard specification. The paver block should got approved by the departmental officers before use on work.
447
-
-
... More
Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick with Plasticizer in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
351
-
-
... More
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shtter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. (Single Leaf)
4.2
-
-
... More
Manufacturing, Supplying and fixing in position of steel windows with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 Kg/m and mullion 'J' section (F4B) of size 46x25 x 3mm at 2.28 kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 Kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS flat at 0.70 Kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR sheets in position firmly. 4 numbers of sturdy hinges and Two number of handle-cum-latch of special type made with 18x5mm MS Flats are revetted to the shutters at an appropriate height in window. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each window shutter having an adjustable stay made out of 18x5mm at 0.70 kg/m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the nds are welded to the out frame of the window by using MS flat of 18x5 mm at 0.70 kg/m, welded to the shutter at two place equivalent from each other from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one cat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS7452/1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.
-
-
-
... More
Three Leaves
8
-
-
... More
Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for G.I. sheet roofing using MS. L. angle of size 50x50x6 mm raffter, Tie angles and MS angle of size 50x50x6mm for sturts and MS plat of size 12 mm thick for fixing G.I. sheet. The purlins using MS L. angle of size 50x50x6 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification.
9769
-
-
... More
Supplying and fixing by drilling holes and not by puching for Roofing with pre painted Galvalum sheet of 0.47mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers, including cutting the sheet to the required size found necessary during execution etc., Complete complying with standard specifications. [The sheet should be got approved by the Engineer incharge before use on works]
667
-
-
... More
Supplying, Fabricating, erecting and fixing Hilux (or) equivalent Gyp Board FALSE CELING upto a ceiling height of 4.50 m from floor level using Perforated sheet 10mm thick which includes shaped GI channels of size 25 x 25 x 0.50 mm thick suspended from ceilling at 1.2 m both longitudinal and cross vertical support and fixing shaped GI channels of size 50 x 30 x 0.50 mm and 150 x 10 x 0.50 mm thick at 0.60m centre longitudinal and cross difrection for vertical supports and fixing U shaped GI channels of size 50 x 30 x 0.50 mm thick and 50 x 10 x 0.50 mm thick at 0.60 m centre to centre in cross direction and respectively for horizantal supports of zig - zag pattern and fixing of Gyp board in the panel provided in the desing pattern given and sprating the standard spection and as directed by the departmental officers. The rate shall be inclusive of finishing the edges and wall junctions with suitable lipping and cornice arrangements.
103
-
-
... More
Providing Cornice Work for Gyp Board False Ceiling as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
80
-
-
... More
Painting two coats of newly plastered wall surface with ready mixed Plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
351
-
-
... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
326.5
-
-
... More
GST @ 18 %
1
-
-
Evaluation Notes How It Works ?