Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date8 Jan 2025
Closing Date13 Jan 2025
Tender Amount₹ 25,06,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Finishing the top of roof with one course of old machine pressed tiles of size 230mm x 230mm x 20mm set in Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers

15.5

-

-

... More
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.

87

-

-

... More
Supplying and filling in foundation, basement, etc with filling M-Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

13.05

-

-

... More
Supplying and filling of well gravel by lorry in basement filling stacking for premeasurtement including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification.

36.5

-

-

... More
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification

19.5

-

-

... More
Brick work in Cement Mortar 1:6 (One Cement and Six M-Sand) using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" including neat finishing, curing, etc., complete complying with standard specification.

-

-

-

... More
For Foundation and Basement

25.2

-

-

... More
For Superstructure in First Floor

30

-

-

... More
Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M-Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) For Superstructure in Second Floor

35

-

-

... More
Supplying and erecting steel Centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

34

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

9.5

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

38

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of M-sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
For Foundation and Basement

9

-

-

... More
For Superstructure in Ground Floor

3

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. Reinforced Cement Concrete Precast Slab 50mm thick using 20mm jelly

54

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

15

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two M-Sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.

3.1

-

-

... More
Paving the floor with best approved quality fine polished Kota Stone Slabs of above size 600 x 600 of 18 / 20mm thick with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

38.5

-

-

... More
Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

11.6

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. Above ground level (External Water Supply) 25mm dia UPVC Pipe

15

-

-

... More
Supplying UPVC Specials (with working pressure 10 kg / sq.cm) in water supply arrangements (both in internal and external water supply arrangements) etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.)

-

-

-

... More
25mm dia UPVC Elbow

2

-

-

... More
25mm dia UPVC Bend

2

-

-

... More
Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)

2

-

-

... More
Supplying and fixing in position best quality approved make cuddapah sink including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]

2

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five M-Sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

440.77

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

48

-

-

... More
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey with machine cut edges for worktable arrangements laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

18.7

-

-

... More
Supplying and painting the walls with two coats of cement paint as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

523

-

-

... More
Supplying and painting the walls with two coats of oil bound distemper including cost for distemper, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).

265

-

-

... More
Painting two coats of plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

177

-

-

... More
Supplying and painting the old walls with two coats of oil bound distemper including cost for distemper, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).

560

-

-

... More
Painting two coats of plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

699

-

-

... More
Painting old wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour in all floors doors, windows, ventilators etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

27

-

-

... More
Painting old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

86.2

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

76.5

-

-

... More
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shtter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. (Double Leaves)

5.04

-

-

... More
Manufacturing, Supplying and fixing in position of steel windows with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 Kg/m and mullion 'J' section (F4B) of size 46x25 x 3mm at 2.28 kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 Kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS flat at 0.70 Kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR sheets in position firmly.

-

-

-

... More
4 numbers of sturdy hinges and Two number of handle-cum-latch of special type made with 18x5mm MS Flats are revetted to the shutters at an appropriate height in window. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each window shutter having an adjustable stay made out of 18x5mm at 0.70 kg/m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the out frame of the window by using MS flat of 18x5 mm at 0.70 kg/m, welded to the shutter at two place equivalent from each other from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one cat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS7452/1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.

-

-

-

... More
Three Leaves

11.7

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete

6.4

-

-

... More
Supplying, fixing of cylindrical vertical notational polyethene water storage tank of 1000 litres capacity confirming to IS 12701 / 96. The tank is meant of outer (or) indoor, use complete with removable hnged top locking arrangements and to make provision to fix with simply pipelines necessary man hole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the departmental officers)

1

-

-

... More
Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for PPGL sheet roofing using MS. square tube of size 50x50x4.50 mm raffter, Tie angles and MS square tube of size 50x50x4.50mm for sturts and MS plat of size 12 mm thick for fixing PPGL sheet. The purlins using MS square tube of size 38x38x4.05 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification.

890

-

-

... More
Supplying and fixing by drilling holes and not by punching for roofing with pre painted Galvalum sheet of 0.47 mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers. including cutting the sheet to the required size found necessary during execution etc., complete complying with standard specifications [ The sheet should be got approved by the Executive Engineer before use on work]

117.5

-

-

... More
GST 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.