National Highways Authority Of India Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

National Highways Authority Of India - NHAI Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date21 Nov 2024
Closing Date5 Dec 2024
Tender Amount₹ 10,94,28,615 
Notes
Download

Costs

Summary

Annual Maintenance Including Incident Management Of Four Laning Of Trichy Bypass To Tovarankurichi To Madurai Section From Km 0/000 To Km 124/840 Of Nh-45b

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

1563.23

145

227957

... More
Clearing road side/Median open lined/pucca drains to bring them original shape, drainage capacity including disposal of sediments , extraneous debris & vegetation growth blocking the free flow from site outside ROW with all leads and lifts complete in all respect as directed by the engineer in charge and as per road maintenance standard clause no .6.1.20 & 6.7 of SP 95-2011 (Frequency of cleaning will be once in a year i.e. before start of monsoon)

15877

48

771940

... More
Clearing slab/box type culverts and pipe culverts including clearing, cleaning and reshaping of upstream and downstream faces of those culverts with in the ROW. The Job includes disposal of excess material recovered site including vegetation outside ROW with all leads and lifts complete in all respect as per direction of Engineer in charge and as per road maintanence Standard clause no.6.5 of SP 95-2011.(Frequency of cleaning will be once in a year i.e. before start of monsoon)

-

-

-

... More
Major and Minor Bridges

13

8739

113609

... More
Slab/Box type culverts/Pipe culvert

288

2375

684262

... More
Repair of kerb with cement concrete of M-20 grade by cutting and trimming the damaged portion to a regular shape, cleaning the area to be repaired thoroughly, applying cement concrete after erection of proper form work.

1168.4

693

810481

... More
Repairing of expanssion joints in Major/minor bridges and flyovers with replacing of modular Strip seal expanssion joints shall confirming IRC SP : 69-2011 clause 7.7, concrete having strength not less than that in superstructure subject to a minimum of M35, for modular strip seal joint the space beneath the joint boxes shall be completed filled with concrete, the technical requirements all as per IRC SP:69-2011 (as per MORTH specification.2607)

44.92

8931

401217

... More
Repair and Replacement of Drainage Spouts complete as per drawing and Technical specification

240

2252

540480

... More
Repair and Replacement of Rainwater Pipe line (160mm dia pvc pipe) complete as per drawing and Technical specification

2255.99

419

946838

... More
Repair and Rehabilitation of Existing structure (Grouting)

178.42

557

99464

... More
Replacment of Rcc Hand Rail by Rcc Crash Barrier on Minor Bridge locations

120

175

21031

... More
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications

459.04

1908

875854

... More
Carriageway cleaning

-

-

-

... More
Carrying out proper cleaning , and removing of dust/silt/trash/plastic/rubbish/garbage/waste from the main carriageway (total width of carriageway LHS+RHS Including median width), foot paths , verges ( Including the verges central median) by mechanical means and from shoulders up to toe line of the embankment including side slopes manually and disposing of the waste material at a suitable place outside ROW as directed by the Engineer and as per road maintenance Standard clause no.6.1.21,6.2,6.3,6.4 of IRC-SP 95-2011. The job includes cleaning of road studs and delineators also.The project stretch should be kept free from rank vegetation all the time throughout the contract period. Payment will be released proportionately in the event of any default.

-

-

-

... More
Cleaning of Maincarriageway length from km.0+317 to km.124+840 ( for 1 Year)

1414.1

11406

16130590

... More
Cleaning of Service road 2 lane (for 1 Year)

132.76

5703

757204

... More
Removal of rank vegetation /weeds and undesirable vegetations from shoulders, embankment slopes up to ROW (both side) complete in all respect including , breaking of clods, rough dressing and disposal of waste material and vegetation at a place outside ROW & Removal of unauthorized board with in ROW and stacking etc.., complete in all respect including transportation from site to nearest store/suitable location as per direction of Engineer in charge and as per road maintenance Standard clause no.6.14 of IRC-SP 95-2011. The project stretch should be kept free from rank vegetation all the time throughout the contract period. Payment will be released proportionately in the event of any default.

1130329.2

6

7279320

... More
Clearing out cleaning of expansion joints, water spouts, vent holes, vegetation around the structure & similar operation each time over bridge/fly over as directed by the Engineer-in-charge.

47

539

25352

... More
Road property Management

-

-

-

... More
Maintenance of Existing plants/shrubs in medians/roads including watering, supply and spreading farmyard manure at 0.064 cum/plant, trimming replacements of causalities of similar edge, providing ad spraying insecticides/ pesticides (existing plants to the tune of 35,778 Nos staggered into 108.95 should be maintained in all respects)as per scope of the work in contract including cleaning small cross drains across the medians complete as per the direction of engineer and as per road maintenance standard clause no.6.1.20 of IRC-SP 95-2011. Payment will be made in pro-rata baisis based on monthly inspection of horticulture expert as per IRC.

322.32

14224

4584951

... More
Painting two coats after filling the Surfase with Synthetic enamel paint in all Shades on Existing /new Plastered Concreate Surface complete in all respect confirming to clause 803 of MORTH rev.V amd as directed by Enginner and a per Clause 803 of MORTH Revv.V and as per other applicable clause in agreement (Up to any lift)

18680.04

146

2727286

... More
Painting two coats after filling the Surfase with Synthetic enamel paint in all Shades on new Plastered Concreate Surface complete in all respect confirming to clause 803 of MORTH rev.V amd as directed by Enginner and a per Clause 803 of MORTH Revv.V and as per other applicable clause in agreement (Up to any lift)

-

-

-

... More
Hectometers stone

244

48

11841

... More
Km stone

45

110

4992

... More
5th km stone

13

228

2974

... More
Providing, painting, lettering and fixing of distant measurement stones including dismantling of old damaged/broken ones confirming to technical specification clause 804 of MORTH Rev.V

-

-

-

... More
Hectometers stone

25

1000

25009

... More
Km stone

5

3568

17841

... More
Providing, fixing and painting of pedestrian guard rails of specified size and specifications as per annexure-1. The one unit of Railing shall be 2 Mtr long with 2 nos of ISA 50 x 50 x 6mm used as the end posts and 20 x 20 mm Sq Bars shall be places at 120mm C/C on One horizontal rails of ISA 40 x 40 x 6mm between two outer posts at bottom, 2mm MS sheet of width 300mm between two outer posts and 50X5 mm Plate at the top of vertical angles .The bottom Horzizontal rail shall be fixed at 250mm from ground and top rail shall be fixed at as per drwaing attached in annexure-1. the total height of the railing shall be 1250mm from the ground. the foundation of the posts shall be 350 x 350 x 450mm PCC15 Concrete. (Consider 1 km length for emergency purpose)

1550

8470

13128500

... More
Removal of unauthorized boards with in ROW and stacking etc. complete in all respect including transportation from site to the nearest store /suitable location as per direction of Engineer in charge.

238

119

28332

... More
Traffic safety items

-

-

-

... More
Providing and erecting Single Sided Double Guard Metal Beam Crash Barrier System 1.70m high, comprising of 3mm thick wall "W" beams posts and spacer channels shall be made by cold roll forming using HR conform to IS 5986 Fe410/360 and dip galvanized having Zinc Mass of 550gms/sqm, minimum 950mm above road/ground level fixed on ISMC series channel vertical post 150x75x5mm spaced at 2m centre to centre 312 x 83mm flange width x3mm thick, 4318mm long post directly embedded in concrete (M15) pit size 350x350x800mm for a depth of 750mm below ground. All fixing bolts and nuts hot dip galvanized confirming to IS:1367 clause 4.60 all complete as per Technical Specification and as directed by the Engineer-in-Charge.

1210

6500

7865000

... More
Providing and fixing retro-reflective stickers (Engineering grade) of size 10 cmx 5cm on MBCBs and other structures as per MORTH CI no.801 and as per approval of Engineer in charge.

10038

90

903420

... More
Supply and Installation of Multicolour Solar Power Blinker with 4"dia 3mm thick Cantilever L-Type pole,3"dia 2.5mm thick advance pole Red /white/blue high frequency flashing lights 3sets,300mm red blinker lights with LED delineators Red/White/Blue along with high frequency flashing circuit box by Automatic ON/OFF system including transportation and erection & fixed firmly in concrete foundation with UG cables on both sides of median openings.

21

180000

3780000

... More
Repairing of installed Multicolor solar blinkers ,replacement of battery with charging unit ,replacement of LED bulps and solar panels for each blinker as directed by the Engineer.

1

65000

65000

... More
Repairing of installed LED solar blinkers ,replacement of battery with charging unit ,replacement of LED bulps and solar panels for each blinker as directed by the Engineer.

54

7000

378000

... More
Providing and Erecting of Retro - Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 -09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of | all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORT&H Specification No.801)

-

-

-

... More
Hazard Markers

30

4000

120000

... More
Providing and fixing of retro-reflectorized cautionary, mandatory and informatory sign(without definition board)made out of High intensity Prismatic grade sheeting confirming to type XI standards IRC 67-2010 and ASTM D 4956 -09, specification and fixed over 2mm thick aluminium sheet fixed on back supporting frame of 25mm x 25mm x3mm Mild steel angle iron post 75mm x 75mm x 6mm with a clear Height of not less then 2.10m from the ground level to the bottom of the sign board and 0.6m below ground level.The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M -15 grade cement concrete 45cm x 45cm x60cm size including cost and conveyonce of all materials,equipment,machinary and labour with all leads and lifts,loading charges necessary for satisfactory completion of the work as directed by the engineer incharge.High intencity retro-reflectro sheets shall consists of min coefficient of retro-reflection as per table 6.6 of IRC 67-2012.The retro refletive sheeting shall be covered under 7 years warranty issued for field performance and a certified company of 3 years outdoor exposure report shall be obtain as pr IRC 67-2012 (as per MORTH specification no 801)

-

-

-

... More
Stop board

79

9976

788104

... More
Median opening sign board

20

6900

138000

... More
Providing and erecting of Direction and Place Identification Retro-reflectorised Signs made out of Cube Corner Micro Prismatic Grade Sheeting confirming to Type-XI standards of IRC-67: 2012 and ASTM D 4956 -09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro -reflective sheeting| shall be covered under 10 year warranty issued for field performance and a certified copy of three| years outdoor exposure report shall be obtained as per IRC 67:2012. { as per MORT&H Specification No.801) (For location of black spot, curve, sharp bend, junction, ghat roads and critical zone applications)

-

-

-

... More
Chevron sign board

117

14041

1642797

... More
Information sign board more than 0.90 sqm

32.4

14355

465102

... More
Providing and installation of Flexible Median Marker delineators (road way indicators, hazard markers) as per IRC 79-2019 for improving median visibility of the road. It shall be made from a combination of tough, high impact resistant engineering thermoplastic material with edge sealed and U shape structure having rebound/ bounce back property having overall height, width and body thickness not less than 180mm, 120mm and 6.5 mm respectively. The reflective sheeting shall be of Type XI Florescent Yellow as per IRC : 67 and it should be on both the face . The logo of the manufacturer shall be embossed on either side of the body in the injection molding process . The body of FMM shall bounce back to its original position after 750 numbers of hits using pendulum of 1.8 Kg conforming to ASTM D 256. It shall be fixed by a combination of epoxy adhesive and grouting/Drilling on concrete medians or properly constructed solid medians. The product to confirm with 2 yrs manufacturers warranty and same needs to submitted by the contractor to engineer-in-charge.

2672

470

1255840

... More
Supplying and installation of delineators (Roadway Indicators) 80-100cm high above ground level.painted at alternatively black and white in 15cm wide strips,fitted with 80 x 100 mm rectangular or 75mm dia circular reflectorised panels at the top,Buried or pressed into the ground and confirming to IRC-79 etc.complete (as per MORTH Specification No.806)

200

2400

480000

... More
Incident Management

-

-

-

... More
Removing all types of broken down/vehicles which have met with accidents from the carriageway and doing the same to proper locations I.e. nearest police station or some suitable location by using 20 tonnes of or of more capacity pick and carry crane, as per IRC: SP: 84-2014 Clause 12.9 and as per other applicable clause agreement. It shall also be filed GPS based vehicle tracking system to monitor its movement on 24 hrs. x 7 days of a week basis for 1 vehicle. Also supply of color photographs in three copies and two CDs complete as per clause 6.8.3 of performance standard and Supply of video cassette (CD) in three copies including videography of complete stretch at three stages in O&M period completed.

-

-

-

... More
From km 0+000 to km 60+950

12

237895

2854746

... More
From km 60+950 to km 124+840

12

237895

2854746

... More
Patrolling by route patrol vehicle as per Clause 6.4 of scope of work and as per Clause 6.8 and 6.8.3 of performance Standard of scope of work.. The route patrol vehicle shall be equipped with precise vehicle tracking system (VTS) (of reputed ISO 9001 company) based on Global provision system (GPS) and GSM / GPRMS technology. The system shall include micro, live, real time tracking web based software through which use of GIS maps and transit, stoppage idle, over speed reports of vehicle shall be obtained. The route patrol vehicle should be as per NHAI policy guidelines/Strengthening incident management services/2018 Policy No. 12.19 dated 20.03.2018. Also supply of color photograph in three copies and two CDs complete as per technical specification clause 125 & supply of video cassette (CD) in three copies including videography of complete stretch at three stages in O&M period complete as per technical specification clause 126. Patrolling stretch shall be 60 Kms vehicle 4 trips of 120 Kms length to and from Monthly running per vechile is kms =120*4*30 = 14400 km.

-

-

-

... More
From km 0+000 to km 60+950

12

477372

5728469

... More
From km 60+950 to km 124+840

12

477372

5728469

... More
Miscellaneous

-

-

-

... More
Maintenance of Toilet blocks which are in truck lay bay and rest areas the work includes cleaning of toilets and maintaing properly, electricity charges ,septic tank cleaning and labour charges for maintaining each toilet blocks per month.

48

40064

1923103

... More
Provision for toilet repairing works which are in truck lay bay and rest areas

-

-

-

... More
km.40+800 LHS (Truck lay bye)

1

204118

204118.61

... More
km.71+800 LHS (Rest Area)

1

195486

195486.11

... More
km.72+100 RHS (Rest Area)

1

197851

197851.11

... More
km.93+400 LHS (Truck lay bye)

1

199131

199131.11

... More
Highmast light

-

-

-

... More
Maintenance Charges for Highmast light for a Years

17

12500

212500

... More
Supplying & Fixing of 12.5m 200w Electrical LED High Mast Flood Light with Automatic dawn dusk operation (with timer) with 6 No. Of luminaire loaded in twin lantern carriage with all accessories including motor and pully at the Junctions as Clause 6.14 of Performance Standards of Scope of Work including maintenance and replacement of the same and as directed by the Engineer-in-charge. The warranty so provided by the Supplier will be in the name of NHAI (Mini Highmast Light)

-

-

-

... More
proposed mini high mast light

2

309750

619500

... More
Maintenance Charges for Minimast light a Years

10

11500

115000

... More
Street lighting with single pole & double arm 1.5mtr fitting 50W - bluetooth Remote enabled MPPT based chage controller with dimmable solar street lignt with ( 2*18WP4V Polycrystaline) mono panel , 2*(24AH 3.6v) battery , , 9mts octagonal pole with all acesssories automatic switch on/off& battery inbulid duty cycle 12 hrs working each night, protections for battery, deep charge protection for battery,reverse polarity protection for panel and battery temperature compensated charging for battery 36 Hrs back up.including foundation work

50

160380

8019000

... More
Street lighting with single pole & single arm 1.5mtr fitting 50W - bluetooth Remote enabled MPPT based chage controller with dimmable solar street lignt with (18WP4V Polycrystaline) mono panel , (24AH 3.6v) battery , 9mts octagonal pole with all acesssories automatic switch on/off& battery inbulid duty cycle 12 hrs working each night, protections for battery, deep charge protection for battery,reverse polarity protection for panel and battery temperature compensated charging for battery 36 Hrs back up.including foundation work.

34

98400

3345600

... More
Toll Plaza

-

-

-

... More
Repairing of Toilets at Toll Plaza under Swatch Bharat Abhiyan- Chittampatti

1

602403

602403

... More
Providing and erecting direction and place identification retro-reflectorized sign as per IRC:67-2012 made of high intensity grade sheeting vide Clause 801.3, fixed over aluminum sheeting 1.5mm thick fixed on a back supporting frame and supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 x 45 x 60cm, 60 cm below ground level as per approved drawing and as directed by the Engineer.10 years pre-qualification warranty as per clause 6.9 of IRC 67-2012 for type XI retro reflective sheeting from the manufacture and certificate copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 including 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted by the contractor for technical qualification in the tender.

-

-

-

... More
Information sign board more than 0.90 sqm

492.17

11805

5810114

... More
Repair of kerb including Bull nose with cement concrete of M-20 grade by cutting and trimming the damaged portion to a regular shape, cleaning the area to be repaired thoroughly, applying cement concrete after erection of proper form work.

225

693

156076

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

8622.37

146

1258865

... More
Toll plaza Tiles Quantity in Bathroom per Plaza

197.97

1730

342627

... More
Replacement of Existing lights on Highmast lights- LED Flood Light 150W with Integrated Driver

25

13647

341175

... More
Replacement of Existing lights on Canopy Lights-LED Flood Light 100W with Integrated Driver

20

9893

197860

... More
Repairing of Highmat light - Electric Motor , wiring works,Timer Switch any other accessories etc.

4

12000

48000

... More
Replacement of Roof AC sheets - Chittampatti Generator Room

-

-

12000

... More
Repairing Toll plaza lane booth

4

10000

40000

... More
Grand total

-

-

109428614.94



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.