Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Nov 2024
Closing Soon27 Nov 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672115_2Tender No
82526/E8 Comprehensive maintenance and repairs to AC Plants for certain Tech Bldgs at AFS ThanjavurTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Scroll type chiller plant 2 x 38 TR and 1 x 38 TR Standby Make:- Blue Star at FMS Bldg. Make:- BLUE STAR
8
-
-
Scroll type chiller plant 2 x 65 TR and 1 x 65 TR Standby Make:- Blue Star at AVIONICS LAB. Make:- BLUE STAR
8
-
-
Scroll type chiller plant 2 x 32.5 TR and 1 x 32.5 TR Standby Make:- Blue Star at EW LAB. Make:- BLUE STAR
8
-
-
Semi harmetic screwcompressor water cooled chiller plant 2 x 120 TR and 1 x 120 TR Standby at Tech Hanger. Make:- VOLTAS
8
-
-
Semi harmetic screwcompressor water cooled chiller plant 2 x 120 TR and 1 x 120 TR Standby at Sqn Hanger. Make:- VOLTAS
8
-
-
Note for Item No - 2.01 to 2.06 :- (i) The rate quoted by the contractor include the rate for inspection / maintenance and testing of Air Conditioning Plant only through the authorised OEM service engineer, checking of water flow, over heating of compressor, serviceability of all components like refrigerant gas pressure switch (High/Low) sensors, condenser / chiller water flow switches, crank case heater, thermostatic expansion valve, electric controle centre micro computer control system, PCBs, SMPS, MCCB, MCBs control wiring etc.
(ii) The duration of the checking is once in every month throughout the currency of contract through OEM authorized service engineer/dealers.
(iii) Periodical test report to be submitted monthly through the authorized OEM service engineer duly signed.
(iv) Report of monthly inspection maintenance carried out by the contractor also to be submitted on every inspection / maintenance and after rectification of any breakdown.
(v) Apart from the monthly periodic inspection the contractor is liable for conducting inspection/maintenance/repair on call basis through the OEM if required. On call the contractor is required to attend the complaint within 24 hrs. Not attending the complaint within 24 hrs contractor shall liable to pay a penalty Rs 2000/- per day.
(vi) The components/spares/consumables required for AC plants will be measured and paid separately under the relevent items here in after.
-
-
-
Descaling of central AC plant of capacity 2 x 25 TR and 1 x 25 standby at SES Bldg by using pressure pump and descaling agents like alkaline coil cleaning and disinfectant solution for every 4 months including disconnecting condensor end cap and refixing the same after descaling and cleaning of strainers of condensor water pipe line including painting of condensor and condensor water pipe line etc complete all as specified and as directed Engr In Charge.
2
-
-
All as per item No - 3 here in before but capacity 2 x 38 TR and 1 x 38 TR Standby at FMS Bldg. Make :- BLUE STAR
2
-
-
All as per item No - 3 here in before but capacity 2 x 65 TR and 1 x 65 TR Standby Make:- Blue Star at AVIONICS LAB. Make:- BLUE STAR
2
-
-
All as per item No - 3 here in before but capacity 2 x 32.5 TR and 1 x 32.5 TR Standby Make:- Blue Star at EW LAB. Make:- BLUE STAR
2
-
-
All as per item No - 3 here in before but capacity 2 x 120 TR and 1 x 120 TR Standby at Tech hanger. Make :- Voltas
2
-
-
All as per item No - 3 here in before but capacity 2 x 120 TR and 1 x 120 TR Standby at Sqn Hanger. Make :- Voltas
2
-
-
Cleaning of cooling tower (01 Nos at SES Bldg) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Cleaning of cooling tower (01 Nos at FMS Bldg) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Cleaning of cooling tower (01 Nos at AVIONICS LAB) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Cleaning of cooling tower (01 Nos at EW LAB) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Cleaning of cooling tower (03 Nos at Tech Hanger) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Cleaning of cooling tower (03 Nos at Sqn Hanger) for cleaning of alkalies by using chemicals through pressure pump complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Supply and fixing in replacement of drain out nipple for cooling tower as per existing complete all as specified and as directed by Engr In Charge.
1
-
-
Supply and fix in replacement butterfly valve of size 80mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement butterfly valve of size 100mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement butterfly valve of size 150mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement non return butterfly valve of size 80mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
3
-
-
Supply and fix in replacement non return butterfly valve of size 100mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
3
-
-
Supply and fix in replacement non return butterfly valve of size 150mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
4
-
-
Supply and fix in replacement strainer for suction Y type of size 100mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement strainer for suction Y type of size 150mm PN - 1.6 complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement brass ball valve of size 25mm complete all as specified and as directed by Engr In Charge.
6
-
-
Supply and fix in replacement brass ball valve of size 50mm including extended GI nipple complete all as specified and as directed by Engr In Charge.
4
-
-
Dismantling and taking out primary and secondary filterts from AHU any size (01 Nos at SES Bldg,/EW Lab/Avionics Lab) cleaning with pressure pump by using cleaning agents complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month for Each plant during the currency of contract.
8
-
-
Dismantling and taking out primary and secondary filterts from AHU any size (02 Nos at FMS Bldg) cleaning with pressure pump by using cleaning agents complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Dismantling and taking out primary and secondary filterts from AHU any size (08 Nos at Tech Hanger) cleaning with pressure pump by using cleaning agents complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Dismantling and taking out primary and secondary filterts from AHU any size (10 Nos at Tech Hanger) cleaning with pressure pump by using cleaning agents complete all as specified and as directed by Engr In Charge. Note :- Each job cosidered for every month during the currency of contract.
8
-
-
Supply and fix in replacement AHU belt B - 111/112 complete all as specified and directed by Engr In Charge.
30
-
-
Supply ans fixing in replacement Limit switch for AHU door any type complete all as specfied and as directed.
4
-
-
Supply and fix in replacement roller type bearing along with non split plummer block housings complete all as specified and as directed.
4
-
-
Supply and fix in replacement modulating thermostat digital type complete all as specified and directed.
3
-
-
Supply and fix in replacement temparature controller for strip heater complete all as specified and directed.
3
-
-
Supply and fix in replacement fire damper control panel unit complete all as specified and directed.
2
-
-
Supply and fix in replacement pressure guage 4 inch dial 0 - 14 KGs rating complete all as specified and as directed by Engr In Charge.
8
-
-
Supply and fix in replacement pressure guage 8 inch dial 0 - 14 KGs rating complete all as specified and as directed by Engr In Charge.
4
-
-
Supply and fix in replacement temparature guage 4 inch dial type or thermometer type 0 - 100/50 degree centigade rating complete all as specified and as directed by Engr In Charge.
8
-
-
Dismantling of existing defective induction motor of the of capacity 1.5 HP any make from the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solid copper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor including replacement of ball bearings and repairing /servicing the multistage centrifugal pump set model No D920/20 by dismantling the pump from induction motor, opening for inspection, replacing the worn out parts like pump shaft, impellers, gland bush, bearings gland bolts and nuts,gland packing, gasket, water seal etc including repaires to pump shaft by remetaling, grinding, polishing and reassembling the same and replasing the rusted nuts, bolts washers etc and testingcomplete all as specified and as directed by Engineer-in-Charge.
2
-
-
All as per Item No 39 but pumping set 5 HP capacity
2
-
-
All as per Item No 39 but pumping set 7.5 HP capacity
2
-
-
All as per Item No 39 but pumping set 10 HP capacity
3
-
-
All as per Item No 39 but pumping set 15 HP capacity
2
-
-
All as per Item No 39 but Cooling tower fan motor 3 HP capacity
1
-
-
All as per Item No 39 but Cooling tower fan motor 5 HP capacity
2
-
-
All as per Item No 39 but AHU Blower motor 7.5 HP capacity
3
-
-
Supply and fix in replacement strip heater 3 KW capacity complete all as specified and directed by Engr In Charge.
30
-
-
Supply and fix in replacement power contactor 40 amps capacity with 1 NO and 1 NC complete all as specified and directed by Engr In Charge.
15
-
-
Supply and fix in replacement power contactor 45 amps capacity with 1 NO and 1 NC complete all as specified and directed by Engr In Charge.
3
-
-
Supply and fix in replacement power contactor 55 amps capacity with 1 NO and 1 NC complete all as specified and directed by Engr In Charge.
5
-
-
Supply and fix in replacement over load relay range between 6 - 10 amps complete all as specified and directed by Engr In Charge.
4
-
-
Supply and fix in replacement over load relay range between 9 - 15 amps complete all as specified and directed by Engr In Charge.
4
-
-
Supply and fix in replacement over load relay range between 20 - 30 amps complete all as specified and directed by Engr In Charge.
4
-
-
Supply and fix in replacement star delta timer adjustable type complete all as specified and directed by Engr In Charge.
4
-
-
Supply and fix in replacement 8 pin relay 240 volt with base complete all as specified and directed by Engr In Charge.
3
-
-
Supply and fix in replacement analog type voltmeter 0-500 Volts including rewiring and fuse carrier and base etc complete all as specified and as directed.
5
-
-
Supply and fix in replacement analog type Ammeter 0 - 100/200/250/300/400 /500 amps including rewiring etc complete all as specified and as directed.
5
-
-
Supply and fix in replacement CT (current transformer) 0 -100/200/250/300/ 400 /500 amps including rewiring etc complete all as specified and as directed.
12
-
-
Supply and fix in replacement digital volt meter of any size 0 - 500 volts including rewiring etc complete all as specified and as directed.
5
-
-
Supply and fix in replacement Digital type Ammeter 0 - 100/200/250/300/400 /500 amps including rewiring etc complete all as specified and as directed.
5
-
-
Supply and fix in replacement LED indicating lamps any type and size (RYB) on panel complete all as specified and as directed.
6
-
-
Supply and fix in replacement ammeter/voltmeter selector switch any type complete all as specified and as directed.
10
-
-
Supply and fix in replacement ON/OFF push buttons any type complete all as specified and as directed.
8
-
-
Dismantling taking out air circuit breaker any capacity calibration, servicing and replacement of fixed and movable contact points, NVC coil, auxillary coils, auxillary thermal magnetic relays, charge springs and greasing of all movable parts etc complete all as specified and as directed.
2
-
-
Supply and fix in replacement MCCB 3 pole adjustable type 400 amps ruptering capacity 36 KA for 415 volts with extendable type handle complete as directed by Engr In Charge. Make :- Havells/ABB/L&T
1
-
-
Supply and fix in replacement MCCB 4 pole adjustable type 400 amps ruptering capacity 36 KA for 415 volts with extendable type handle complete as directed by Engr In Charge. Make :- Havells/ABB/L&T
1
-
-
Supply and fix in replacement MCCB 3 pole adjustable type 25 to 100 amps ruptering capacity 25 KA for 415 volts complete as directed by Engr In Charge. Make :- Havells/ABB/L&T
8
-
-
S&F MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
8
-
-
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
15
-
-
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
20
-
-
Material and labour painting with two coats condensor water pipe line 80/100mmof size (SES AC Plant Bldg 50 TR AC Plant) from cooling tower to pumps and upto chiller units by using plasitic emulsion paint complete all as specified and as directed.
1
-
-
Material and labour painting with two coats condensor water pipe line of size 100/150mm (FMS AC Plant Bldg 76 TR AC Plant) from cooling tower to pumps and upto chiller units by using plasitic emulsion paint complete all as specified and as directed.
1
-
-
Material and labour painting with two coats condensor water pipe line of size 100/150mm (Avionic lab AC Plant Bldg 130 TR AC Plant) from cooling tower to pumps and upto chiller units by using plasitic emulsion paint complete all as specified and as directed.
1
-
-
Material and labour painting with two coats condensor water pipe line of size 100/150mm (EW lab AC Plant Bldg 65 TR AC Plant) from cooling tower to pumps and upto chiller units by using plasitic emulsion paint complete all as specified and as directed.
1
-
-
Material and labour painting with two coats condensor water pipe line of size 150/200mm (SQN & Tech AC Plant Bldg 240 TR AC Plant) from cooling tower to pumps and upto chiller units by using plasitic emulsion paint complete all as specified and as directed.
2
-
-
Supply and fix/lay three core flat industrial PVC insulated and PVC sheathed multistranded copper cable of size 4 sqmm complete all as specified and as directed.
200
-
-
Supply and fix/lay three core flat industrial PVC insulated and PVC sheathed multistranded copper cable of size 6 sqmm complete all as specified and as directed.
200
-
-
Supply and fixing in replacement phase failure relay and under voltage relay setting (Variable) (Auto reset 4% to 20% unbalance) including control wiring complete all as per Minilec model No S2 VMR 3 or equivalent in GIC/Proton/L&T complete all as specified and as directed.
20
-
-
Supply and fix cooling tower fills made of corrogated virging quality PVC film duly vacumme formed and edge folded for extended service life for blue and black colour complete all as specified and as directed.
20
-
-
Supply and fixing in replacement condensor / chiller water pressure switch as per existing make and size complete all as specified and as directed by Engr In Charge.
4
-
-
Supply and filling refrigerant gas R - 407C in central AC plant of any capacity including vaccume by using vaccume pump or topping up and ckeking of leakages by using halide torch and brazing the leakage portion etc complete all as specified and as directed by Engr In Charge.
50
-
-
Supply and fix in replacement micro computer control system for Air conditioning plant any capacity including repairing of SMPS and PCB of capacity 25TR to 120 TR including disconnecting electrically / electronically complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement refrigerant gas pressure switch (High/Low) universal type complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement thermostatic expantion valve suitable for 25/32.5 TR central AC Plant complete all as specified and as directed by Engr In Charge.
2
-
-
Supply and fix in replacement thermostatic expantion valve suitable for 120 TR central AC Plant complete all as specified and as directed by Engr In Charge.
1
-
-
Total of Schedule 'A'
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%