Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date27 Nov 2024
Closing Date25 Dec 2024
Tender Amount₹ 5,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Labour for fine seived excavated dry soil laid to the required width of trench at botom and top of cable as cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning

98

-

-

... More
Supply and laying reinforced precast concrete cable cover, class HV, type 1, Flat of size 300 mm x 180 mm x 40 mm complete all as specified and as directed.

3200

-

-

... More
Supply and lay common burnt clay building bricks, sub class 'B' of old size for cable protection all as specified and as directed.

4800

-

-

... More
Supply and laying the following HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanized steel wire strip tap 11000 volts grade conforming to IS specifications in trenches/ poles/ wall etc and including taking down the existing unserviceable cable complete all as specified and as directed by Engineer-in-Charge :-

-

-

-

... More
HT UG Cable of size 3 core 95 sqmm .

350

-

-

... More
HT UG Cable of size 3 core 120 sqmm .

60

-

-

... More
HT UG Cable of size 3 core 185 sqmm .

40

-

-

... More
Taking out HT XLPE UG Cable / PVC Sheathed aluminium conductor 95 to 185 sqmm x 3 core armoured from trenches/poles/wall etc and relaying / rerouting HT cable after fault rectification duly tested in trenches/Poles/Wall complete all as specified and directed. Note: Necessary earth Work and connected items, jointing kit shall be measured and paid separately under relevant Item

600

-

-

... More
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable complete all as specified and as directed:- Note: Earth work excavation and connected items shall be measured and paid separately under respective items

-

-

-

... More
50 sq mm 3.5 Core

380

-

-

... More
95 sq mm 3.5 Core

350

-

-

... More
M&L for finding of fault from HT cables by using of high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position/location of fault, disconnecting faulty 11 KV HT cable and taking out from trenches/Poles/HT equipments of different sizes from both ends, removal of fault, Re-connections including testing of cables after removal of fault complete all as specified and directed by Engineer-in-Charge. Note: (a) Cable & joints shall be measured and paid separately under respective items (b) Quoted rate shall be inclusive of hiring charges for HT fault Locater equipments. (c) Rate quoted inclusive of all material and labour required for emergency maintenance work of HT/LT cable line during breakdown by deploying skilled persons at faulty site including transportation and other tools and plant required at site for fault rectification.(d) Contractor or his representative shall come to the site and attend and rectify the breakdown / complaints within two hours of receipt of the incident/complaint of notification of breakdown.If fails to rectify the complaints within two hours, a penalty of Rs 500 per fault per hour shall be imposed and shall be deduct from the due payment against the contractor .

16

-

-

... More
S&F in repairs indoor termination cold shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-

-

-

-

... More
HT UG Cable of size 3 core 95 sqmm .

5

-

-

... More
HT UG Cable of size 3 core 120 sqmm .

2

-

-

... More
HT UG Cable of size 3 core 185 sqmm .

2

-

-

... More
S&F in repairs outdoor termination heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminum conductor of following sizes complete all as specified and as directed :-

-

-

-

... More
HT UG Cable of size 3 core 95 sqmm .

25

-

-

... More
HT UG Cable of size 3 core 120 sqmm .

4

-

-

... More
HT UG Cable of size 3 core 185 sqmm .

2

-

-

... More
Supply and fixing in repairs Straight through heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labor complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-

-

-

-

... More
HT UG Cable of size 3 core 95 sqmm .

8

-

-

... More
HT UG Cable of size 3 core 120 sqmm .

2

-

-

... More
HT UG Cable of size 3 core 185 sqmm .

1

-

-

... More
M&L for disconnection and removing the unserviceable Aluminium conductor / jumper wires from the HT 2/4/6 Pole structure and provision of new Aluminium overhead conductor jumpers surrounded by PVC insulation sleeves with R,Y& B color code complete all as specified and directed. Note : (a) All the jumper wires should be replaced with new jumper wires (2) Type of conductor used for jumper should be RABBIT. (3) Quoted rate shall deemed to be inclusive for all the misc work such as Nut, bolts, washers, welding etc. for satisfactory completion of job . (4) Minimum clearance should be maintained among the conductors as per the Electricity Regulations. (5) Zero percent sag should be maintained for each jumper wire to avoid short circuits.

20

-

-

... More
Supply and install polymer Switch Air Break gang operated triple pole ,mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level complete with 9 number polymer insulators of rating up to 200 Amp, 11000 volts including necessary length of down pipe made up of galvanized iron medium grade 20mm bore with operation handle and locking arrangements including taking down the old unserviceable one complete all as specified and as directed .

4

-

-

... More
Supply and lay galvanized iron tubing of 80 mm dia ,light grade in trenches / fixed on poles complete including all necessary fittings including taking down the old unserviceable one complete all as specified and as directed .

40

-

-

... More
S&F in repairs pin type insulator ,polymer, including one galvanized mild steel spindle ,two galvanized iron washers and one galvanized iron nut for 11000 volts grade complete all as specified and directed.

12

-

-

... More
S&F in repairs reel type disc insulator, porcelain, vitreous brown colour size 65mm dia x 31mm high x 20mm hole working pressure 11000 volts grade complete all as specified and as directed .

40

-

-

... More
S&F in repairs loop type porcelain insulator vitreous white, brown, or green with over all dimension 90 x 140 mm clearance of hole 25.5 mm complete all as specified and as directed .

5

-

-

... More
S&F ACSR conductor of any size for HT over head line including jumpers on PCC/RCC/Steel pole and binding wires for line connecting up etc of any size including taking down the old unserviceable ACSR conductor complete all as specified and as directed .

2

-

-

... More
S&F Anti climbing device, spikes type, fabricated out of MS bars round square and flat including nuts, bolts, washers and welding into two halves made to shape to suit to the cross section of the pole of any size including taking down the old unserviceable Anti climbing device complete all as specified and as directed.

0.2

-

-

... More
S&F Mild steel cross arms ,bracing supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding ,bending, cold or hot drilling holes for insert bolts in any shape or size as indicated and as directed including applying one coat of red oxide primer and one finishing coat of aluminum paint and taking down old unserviceable cross arms etc complete all as specified and as directed.

3.5

-

-

... More
S&F in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts suitable for HT of approved of size 25x20 cm complete all as specified and as directed.

80

-

-

... More
S&F in repairs polymer Lightening arrester expulsion type complete with all fitting transmission class ,discharge capacity 200-800 Amp 11000 Volts rating complete all as specified and as directed.

6

-

-

... More
Supply and lay synthetic rubber insulated mat of 2 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2.0 m x1.0 m including taking down old unserviceable mat complete all as specified and as directed.

4

-

-

... More
Supply and lay synthetic rubber insulated mat of 2.50 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2.0 m x1.0 m including taking down old unserviceable mat complete all as specified and as directed.

8

-

-

... More
Supply and spreading hard core with broken stone of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surfaces complete all as specified and as directed.

30

-

-

... More
S&F in repairs Horn Gap type Fuse unit, 11000 volts grade, mounted on polymer insulators and steel frame, single pole, fixed on DP structures complete all as specified and as directed.

20

-

-

... More
S&F in repairs Expulsion type drop out fuse element 10 Amps and up to 100 Amps suitable for 11KV Horn Gap type fuse unit complete all as specified and as directed.

40

-

-

... More
M&L for overhauling and calibration by using suitable testing kits of under mentioned capacities HT equipments (i.e. VCB, RMUs, Compact Sub Stn Units) by drawing out the draw-out module of the breaker, carrying out complete cleaning with clean cloth & cleaning agent, lubrication of the mechanism & greasing with high temperature molly grease, testing for smoother ON/OFF operation, carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relays, checking of healthiness of CTs & points ,checking of IR value of interrupters, healthiness of protection tripping of circuit breaker etc. choking and servicing switchgear interlocks and safety like Mechanical - 1. Positive Interlock, 2.Negative Interlock, 3. Spring Discharge Interlock, 4. Padlocks, 5. Key Interlocking 6. Safety Roll in Stop, 7. Safety Roll - out Stop,8. Rating Interference Interlock. Electrical - Interlock Switches), checking of electrical operations of the breaker for ON/OFF & Trip operation for Incomer and Outgoing including submission of service & test reports. Make: Crompton Greaves/ABB or any other equivalent make/model approved by Accepting Officer . Note: (a) The servicing should be carried out through Authorized service provider of original Manufacturer. (b) Any minor items which are not covered in above description but required for successful operation of the panel shall be provided by the contractor and quoted rate shall be inclusive for the same and nothing extra shall be paid .

6

-

-

... More
Supply and replacement of following items of 400 Amps to 800 Amp capacity, 11 KV, 3 phase, 50 Hz, HT VCB/RMU/CSS of any quantity during servicing of HT equipments as stated in above item including taking down old unserviceable items complete all as specified and as directed.

-

-

-

... More
Charging Gear

2

-

-

... More
Rack in and out Gear

2

-

-

... More
Rack in and out mechanism complete. Make: ABB or other euivalent as per site rquirement

2

-

-

... More
Charging Rod

2

-

-

... More
Rocker Lever

2

-

-

... More
Charging Bush

2

-

-

... More
Spring charging mechanism

2

-

-

... More
630A Vacuum Interrupter

2

-

-

... More
Tripping coil

3

-

-

... More
Tripping Relay

3

-

-

... More
Over current earth fault relay, Phase and earth current input 1/5A,ICE version.

3

-

-

... More
Breaker control switch

3

-

-

... More
Manual spring charging handle

3

-

-

... More
S&F in repairs push buttons (Closing/Tripping) of any type / model / capacity in HT equipments / panels complete all as specified and as directed.

3

-

-

... More
S&F in repairs indicating lamp of any type / model / capacity in HT VCB/SFU panels complete all as specified and as directed. Make: Siemens or other euivalent as per site rquirement

15

-

-

... More
S&F in repairs multifunction meter with RS port of any type / model / capacity in HT equipments /panels complete all as specified and as directed.

2

-

-

... More
S&F in repairs TNC switch of any type / model / capacity in HT equipments / panels complete all as specified and as directed.

2

-

-

... More
S&F in repairs heating element 250 Watts with thermostat including necessary wiring of any type / model / capacity in HT equipments / panels complete all as specified and as directed.

10

-

-

... More
S&F in repairs power pack unit suitable for 220 volts AC input & 24 volts DC, 4 Amps output complete suitable for operation of HT Panel all as specified and directed.

2

-

-

... More
S&F in repairs of insulators of any size / model suitable for HT eqpts/panels complete all as specified.

30

-

-

... More
S&F in repairs of cable boots suitable for HT cables of any size and model complete all as specified and as directed.

15

-

-

... More
M&L in repairs of Tulip contact assembly for suitable finger type complete all as specified and as directed.

2

-

-

... More
M&L in repairs of 64 Pin plug for unigear system with control wiring complete all as specified and as directed.

3

-

-

... More
M&L for rectifying fault after inspecting HT equipments / panels of any type / model complete all as specified and as directed by engineer-in-Charge. Note: (a) The fault finding should be carried out through Authorized service provider of original Manufacturer. (b) Spares shall be measured and paid separately under relevant items. (c) Any minor items which are required for operation and smooth functioning of equipments shall be provided by the contractor and quoted rate shall be inclusive for the same (d) Contractor should attend and rectify the breakdown / complaints within two hours of receipt of the complaint ,if not a penalty of Rs 500 per fault per hour shall be imposed and shall be deduct from the due payment against the contractor

10

-

-

... More
M&L for replacement of existing Current Transformer (CT) of 11 KV rating with new indoor epoxy cast,11 KV,50Hz,100-0/5A suitable for operation in existing HT panel as per site condition complete all as specified and as directed.

9

-

-

... More
M&L for carrying out complete servicing of AB Switch by lubricating the mechanical parts invluding greasing with petroleum jelly complete all as specified and as directed. Note: Minimum spares /lubricants and tools required for the job shall be deemed to be included in the quoted rates.

12

-

-

... More
Labour only for stringing of ACSR conductor from pole to pole upto 3 conductors by maintaining sag as per HT specification complete all as specified and as directed by Engineer-in-Charge. Note :- (a). One unit RM of stringing consists of tightning of 3 conductor of 1 RM length. Note: (b). Minimum spares and tools required for the job shall be provided be be deemed to be included in the quoted rates.

500

-

-

... More
S&F in repairs HT 11 KV Phase/Line Separator for fixing OH ACSR conductor 11 KV range complete all as specified and as directed.

10

-

-

... More
M&L for preparation of old painted surface by removing dust and other deposited materials by scraping from HT tubular pole of 11 metre long, painting of pole with one coat of black paint up to 1.0 m from bottom and painting the rest of the pole including cross arms cable protection pipe,clamps , with one coat of aluminium paint complete all as specified and as directed.

80

-

-

... More
M&L for servicing of four pole structure including checking / tightening / making free for operating of AB switches, insulators, lightning arresters, changing of nut / bolts if required including painting of RYB paint / tape at strip including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11 metre long, painting of pole with one coat of black paint upto 1.0m from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminum paints complete all as specified and as directed .

5

-

-

... More
M&L for servicing of two pole structure including checking / tightening / making free for operating of AB Switches, insulators, lightning arresters, changing of nut/bolts if required including painting of RYB paint/tape at strip including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11.0 metre long, painting of pole with one coat of black paint upto 1.0 m from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminium paints complete all as specified and as directed.

10

-

-

... More
M&L for disconnecting the transformer of capacity up to 200KVA from the electrical system, taking out and shifting the same for repairing to work shop, drain out old transformer oil, opening the top cover of the transformer with conservator and taking out core with limbs and primary & secondary windings after disconnecting and removing iron core, removing damaged primary & secondary windings etc as per requirement and rewinding, re insulating and removal of moisture on oven heating & re-assembling transformer winding and core heating including insulating and packing material in order to take out all moisture from the transformer assembly complete, lowering the core assembly with winding in transformer body, connection work and re-assembling in position top cover, conservator, breather with relay control wiring complete including transportation of transformer back from workshop to site, installation of transformer on foundation, commissioning and testing complete all as specified and directed. Note:- (a) Necessary T&P items as required for shifting of transformer from site to workshop and back shall deemed to be included in the quoted rate. (b) Copper winding wire for rewinding shall be measured in Kg and paid separately under relevant of items . (c) Draining of transformer oil, filtering & dehydrating of oil and filling back if found usable in to the transformer shell and gasket and miscellaneous items as required for smooth functioning shall deemed to be inclusive in the quoted rate

3

-

-

... More
M&L for copper winding, paper insulated wire complete as per existing gauge for existing number of turns for LV/HV coil/leg rewinding of transformer of any capacity complete all as specified and as directed

170

-

-

... More
M&L for disconnection and removing the unserviceable/ burnt out Primary 11 KV bushing units from transformer of any capacity/model complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete all as specified and directed.

12

-

-

... More
M&L for disconnection and removing the unserviceable/ burnt out Secondary LT bushing units from transformer of any capacity/model complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete all as specified and directed.

12

-

-

... More
M&L for replacement of fiber gasket sheet 3 mm thick to prevent leakage from transformer 11/0.433 KV ratio, up to 500 KVA capacity complete

10

-

-

... More
M&L for replacement of porcelain insulator with suitable rubber 'O' ring for HT side bushing of transformer up to 630 KVA complete

10

-

-

... More
All as per above item No 55 here in before but for LT side bushing

11

-

-

... More
Supply and filling Silica Gel from transformer breather of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.

4

-

-

... More
Supply and fixing Breather assembly of size 50 mm dia,minimum 250mm long suitable for transformer of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.

4

-

-

... More
Supply and fixing of oil temperature indicator dial type having temperature range 0 to 120 degree Celsius suitable for transformer of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.

3

-

-

... More
M&L for disconnecting the transformer connections HT/LT of any capacity/model, pole/plinth mounted shifting the same in AOR of GE Avadi and connect to the existing HT/LT cables properly complete all as specified and directed. Note:- Necessary T&P items as required for shifting of transformer shall deemed to be included in the quoted rate.

5

-

-

... More
M&L for painting outer surfaces of transformers of capacity 63 to 500 KVA, any type / make / model, pole or plinth mounted, installed at various sub stations with one coat of synthetic enamel paint of approved color, after cleaning all surfaces including writing SM / MES numbers, capacity, make, date of oil testing etc.,in paint complete all as specified and as directed.

14

-

-

... More
M&L for ON load centrifuging and dehydration including filtration, heating, re-circulation and cleaning of transformer oil by dehydration machine for 11/0.433 KV transformers Indoor/Outdoor type up to 500 KVA capacity installed at different sub stations/locations (i.e. AOR of GE Avadi) for improving di-electric strength of the oil to with stand 40 KV for one minute including testing of oil complete all as specified and as directed. Note :- (a) Deficient quantity of Transformer oil required for topup shall be measured and paid separately under relevant items. (b) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. (c)Transformer oil test kit shall be provided by the contractor at site for testing of oil.

2850

-

-

... More
Supply and filling/topping up new transformer oil conforming to IS Specification for transformers installed at various sub stations complete all as specified. (Make:-HP/Castrol/Power oil)

1000

-

-

... More
Hiring of transformer of capacity 200KVA as and when the existing transformer shifted to work shop for repairing /maintenance works complete all as specified and directed by Engineer-in-charge. Note:- (a) Hiring of transformer for 24 Hours shall be measured as one job (b) Necessary T&P and transport etc as required for shifting of transformer from site to workshop and back and necessary connection etc shall deemed to be included in quoted rate.

6

-

-

... More
M&L for cutting/clearing and removing the vegetation/bush/creepers growth any nature/type around/on the electric poles/stays/two and four pole structures/installations / substation, so as to keep clean the area for easy access to carry out repair/maintenance works on poles etc, removing from site and throwing out at a place where directed at distance not exceeding 250 m away complete all as specified and as directed by Engineer-in-Charge.

450

-

-

... More
M&L for pruning of tree branches and making clear HT line to the minimum distance of 30 m span for 3/6 conductors and removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.

120

-

-

... More
S&F in repairs MS wire mesh of size 75mmx75mm ,4mm dia made into mattress or cages approximately 2.0 m height and fixed with flat iron/angle iron by welding in position and complete all as specified and directed. Note:- MS angle, MS flats, Nuts, Bolts and washer shall be measured and paid separatly under relevant items.

50

-

-

... More
M&L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.

50

-

-

... More
S&F in repiairs mild steel work of angle iron channels and iron flats for post and struts of fencing around Transformer / Panel Boards and fixing of sign boards etc drilling holes, flat iron for securing wire mesh by welding to angle iron frame and framed work as in door/ gate of angle and wire mesh door to be fixed by 02 Nos 100mm long hinges and one sliding door with nut and bolts for locking arrangement complete all as specified and directed.

6

-

-

... More
M&L for preparation of old painted surfaces by removing dust and other deposited materials by scraping from HT panel inner and outer surface of front and rear doors and applying one coat of synthetic enamel paint ( existing colour) by using spray gun complete all as specified and as directed.

6

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6 mm thick burried directly in ground (earth plate not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanized iron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron and earth wire protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters, complete all as directed and connecting to existing earth test point all as specified or indicated including testing on completion.

20

-

-

... More
All as per above item 67 here in before but using copper earth plate of size 60cm×60cm ×3 mm thick electrode and 20×3mm thick copper earth strip complete all as specified and directed.

10

-

-

... More
M&L for Earth continuity conductor or main earthing lead of GI strip of size 25x4mm , fixed to wall or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc. as required complete all as specified and as directed. Note :- Eathing continuity conductor beyond 7.5m for Earthing shall be measured under this item.

80

-

-

... More
All as per above item No 73 here in before but for copper strip of size 20x3mm thick

40

-

-

... More
M&L for repairing earth pit including earth work exacavation as required , PCC work to make good damaged/disturbed surfaces of earth pit chamber and making new pit cover with RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways including lifting handle, wire mesh and funnel including re-connection of earth wire /strip with panel /equipments using GI nut, bolts & washer complete all as specified & directed

45

-

-

... More
Supply ,fabricate, install, connect, test and commissioning busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron / flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (a) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (b) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos. Note : MCCB shall be front handle operated.

4

-

-

... More
M&L for disconnection and removing the unserviceable steel tubular poles ,supply and erect Steel tubular swaged poles 11.00 meters long ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 complete all specified and as directed. Note:- Excavation, PCC foundation , returning filling, pole painting and numbering shall be measured and paid separately under relevant item

10

-

-

... More
M&L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all specified and directed.

9.25

-

-

... More
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping, filling and mass concrete including necessary form work as required complete all specified and directed.

15

-

-

... More
M&L for Sand cushioning to underground cables by filling river sand upto top of the cable in 11 KV Sub stations complete all as specified. Note :- Thickness shall be measured after punning

2

-

-

... More
S&F in repairs informatory / equipments history sign boards of size not less than 900mm x 600 mm rectangular type with 2 mm thick MS sheet plain type made out of angle iron channels frame, back ground and euipments history details(i.e. Name, Make, Ser No,capacity of eqpt, vintage, SM/MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete all as specified and directed.

16

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.