Military Engineer Services Tender
... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 29,90,000
Costs
EMD
₹ 59,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691401_1Bid Award Id
ViewTender No
8475/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for providing sand cushioning for protection of UG cable in trenches with coarse Riddled Earth of approved quality as approved in writing by GE including filling, spreading and punning down to desired thickness complete and all as specified and directed by Engr-in-Charge.
104
-
-
... More
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed.
10940
-
-
... More
M&L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and directed. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
30
-
-
... More
Description all as per Item Sl No 06 here in above but of bore 80 mm.
40
-
-
... More
M&L for cutting the existing hardstanding/PCC/WBM road at a depth of not less than 60 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
30
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed.
100
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed.
150
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed.
250
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed.
300
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed.
300
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2.0 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
250
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2.0 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
250
-
-
... More
S&F MCCB, 4 pole,400A rating (Ics = 100% Icu),415Volts,36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge.
2
-
-
... More
S&F MCCB, 4 pole,200A rating (Ics = 100% Icu),415Volts,36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge.
3
-
-
... More
S&F MCCB, 4 pole,160A rating (Ics = 100% Icu),415Volts,36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge
4
-
-
... More
S&F MCCB, 4 pole,100A rating (Ics = 100% Icu),415Volts,16 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge
4
-
-
... More
S&F MCCB, 4 pole,125A rating (Ics = 100% Icu),415Volts,16 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge
4
-
-
... More
S&F MCCB, 4 pole,63A rating (Ics = 100% Icu),415Volts,16 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge
6
-
-
... More
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 250 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed
1
-
-
... More
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed
2
-
-
... More
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 160 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed
1
-
-
... More
S & F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts complete all as specified and as directed Engr-in-charge.
50
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 1200 mm (height) x 1500 mm (breadth) x 500 mm (depth) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv LT panel of any size/type complete all as specified & as directed with & including the following accessories complete all as specified & as directed
1
-
-
... More
BUS - BAR & INTERNAL CONNECTIONS:
The Bus Bar shall be made up of 04 Nos high grade Aluminium 500 A rated , duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulation of non- hygroscopic, non - combusitable , all internal connection from main bus-bars to swicth gears etc.
PROVISION FOR CABLE ENTRY:-
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cable with help of glands
Incoming:-
(a) MCCB 4 P (Lcs=100% ICU) with adjustable short circuit & adjustable overload setting for isolation , having breaking capacity 36 KA & of rating 250 Amps -02 Nos (1W + 1S)
Outgoing:-
(a) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 100 Amps - 03 Nos (2 W + 1S)
(b) Time Switch (Daily & Weekly Programmable Electronic type ) 415 V , 3 Phase of 20 A rating with Contactor - 01 Sets (c) MCB TPN 63A.-2 Nos
INSTRUMENTATION SYSTEM
(a) Digital type Multi-Function meter with built in selector Switch with and 03 No's of CT's matching with the I/C breaker, Accuracy class - 1-3, phase, size 96 x 96 mm or any techo-commercially equivalent in secure / Elmeasure
(b) Indicator Lamp with integral circuit (230 / 240 V) & cluster LED (Red, Orange, Blue) - 01 Set
(c) Danger notice plate of size 20x15cm 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LTconforming to IS-2551 - 02 Nos (Front & Back)
(d) Door Opening Keys - 02 Nos
-
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 1200 mm (height) x 1500 mm (breadth) x 500 mm (depth) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv LT panel of any size/type complete all as specified & as directed with & including the following accessories complete all as specified & as directed
1
-
-
... More
BUS - BAR & INTERNAL CONNECTIONS:
The Bus Bar shall be made up of 04 Nos high grade Aluminium 500 A rated , duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulation of non- hygroscopic, non - combusitable , all internal connection from main bus-bars to swicth gears etc.
PROVISION FOR CABLE ENTRY:-
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cable with help of glands
Incoming:-
(a) MCCB 4 P (Lcs=100% ICU) with adjustable short circuit & adjustable overload setting for isolation , having breaking capacity 36 KA & of rating 250 Amps -02 Nos (1W + 1S)
Outgoing:-
(a) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 100 Amps - 04 Nos (3 W + 1S)
(b) MCB TPN 63A.-2 Nos (1W+1S)
INSTRUMENTATION SYSTEM
(a) Digital type Multi-Function meter with built in selector Switch with and 03 No's of CT's matching with the I/C breaker, Accuracy class - 1-3, phase, size 96 x 96 mm or any techo-commercially equivalent in secure / Elmeasure
(b) Indicator Lamp with integral circuit (230 / 240 V) & cluster LED (Red, Orange, Blue) - 01 Set
(c) Danger notice plate of size 20x15cm 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LTconforming to IS-2551 - 02 Nos (Front & Back) (d) Door Opening Keys - 02 Nos
-
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 1200 mm (height) x 1500 mm (breadth) x 500 mm (depth) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv LT panel of any size/type complete all as specified & as directed with & including the following accessories complete all as specified & as directed
1
-
-
... More
BUS - BAR & INTERNAL CONNECTIONS:
The Bus Bar shall be made up of 04 Nos high grade Aluminium 600 A rated , duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulation of non- hygroscopic, non - combusitable , all internal connection from main bus-bars to swicth gears etc.
PROVISION FOR CABLE ENTRY:-
The provision for cable entry / exit shall be provided in the bottom for both incoming & out-going cable with help of glands
Incoming:-
(a) MCCB 4 P (Lcs=100% ICU) with adjustable short circuit & adjustable overload setting for isolation , having breaking capacity 36 KA & of rating 320 Amps -01 Nos Outgoing:-
(a) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 100 Amps - 05 Nos (4 W + 1S)
(b) MCB TPN 63 A.-2 Nos
INSTRUMENTATION SYSTEM
(a) Digital type Multi-Function meter with built in selector Switch with and 03 No's of CT's matching with the I/C breaker, Accuracy class - 1-3, phase, size 96 x 96 mm or any techo-commercially equivalent in secure / Elmeasure
(b) Indicator Lamp with integral circuit (230 / 240 V) & cluster LED (Red, Orange, Blue) - 01 Set
(c) Danger notice plate of size 20x15cm 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LTconforming to IS-2551 - 02 Nos (Front & Back)
(d) Door Opening Keys - 02 Nos
-
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 1200 mm (height) x 1500 mm (breadth) x 500 mm (depth) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv LT panel of any size/type complete all as specified & as directed with & including the following accessories complete all as specified & as directed
1
-
-
... More
BUS - BAR & INTERNAL CONNECTIONS:
The Bus Bar shall be made up of 04 Nos high grade Aluminium 600 A rated , duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulation of non- hygroscopic, non - combusitable , all internal connection from main bus-bars to swicth gears etc.
PROVISION FOR CABLE ENTRY:-
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cable with help of glands
Incoming:-
(a) MCCB 4 P (Lcs=100% ICU) with adjustable short circuit & adjustable overload setting for isolation , having breaking capacity 36 KA & of rating 320 Amps -01 Nos Outgoing:-
(a) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 100 Amps - 04 Nos (3 W + 1S)
(b) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 125 Amps - 01 Nos
(c) MCB TPN 32 A.-2 Nos
(d) Time Switch (Daily & Weekly Programmable Electronic type ) 415 V , 3 Phase of 20 A rating with Contactor - 01 Sets INSTRUMENTATION SYSTEM
(a) Digital type Multi-Function meter with built in selector Switch with and 03 No's of CT's matching with the I/C breaker, Accuracy class - 1-3, phase, size 96 x 96 mm or any techo-commercially equivalent in secure / Elmeasure
(b) Indicator Lamp with integral circuit (230 / 240 V) & cluster LED (Red, Orange, Blue) - 01 Set
(c) Danger notice plate of size 20x15cm 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LTconforming to IS-2551 - 02 Nos (Front & Back)
(d) Door Opening Keys - 02 Nos
-
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 1200 mm (height) x 1500 mm (breadth) x 500 mm (depth) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv LT panel of any size/type complete all as specified & as directed with & including the following accessories complete all as specified & as directed
2
-
-
... More
BUS - BAR & INTERNAL CONNECTIONS:
The Bus Bar shall be made up of 04 Nos high grade Aluminium 500 A rated , duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulation of non- hygroscopic, non - combusitable , all internal connection from main bus-bars to swicth gears etc.
PROVISION FOR CABLE ENTRY:-
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cable with help of glands
Incoming:-
(a) MCCB 4 P (Lcs=100% ICU) with adjustable short circuit & adjustable overload setting for isolation , having breaking capacity 36 KA & of rating 250 Amps -01 Nos (b) Onload changeover switch -01 Nos, open-execution modular construction type , confirming to IS/IEC 60947, -3 rated current -250 Amps 415 volts , 4 pole, AC 23 A -01 Nos
Outgoing:-
(a) MCCB 3 P ( lcs= 100%) with thermal magnetic release, adjustable short circuit & adjustable overload setting , suitable for isolation , having breaking capacity 25 kA & of rating 100 Amps - 04 Nos (3 W + 1S)
(c) MCB TPN 63 A.- 2 Nos
(d) Time Switch (Daily & Weekly Programmable Electronic type ) 415 V , 3 Phase of 20 A rating with Contactor - 01 Sets INSTRUMENTATION SYSTEM
(a) Digital type Multi-Function meter with built in selector Switch with and 03 No's of CT's matching with the I/C breaker, Accuracy class - 1-3, phase, size 96 x 96 mm or any techo-commercially equivalent in secure / Elmeasure
(b) Indicator Lamp with integral circuit (230 / 240 V) & cluster LED (Red, Orange, Blue) - 01 Set
(c) Danger notice plate of size 20x15cm 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LTconforming to IS-2551 - 02 Nos (Front & Back)
(d) Door Opening Keys - 02 Nos
-
-
-
... More
Supply, install, testing & commissioning of LT busbar junction box "out-door type" of size 750 mm (height) x 600 mm (breadth) x 300 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The box shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade aluminum bus-bar of rating 400A of length 600mm, min spacing of 80mm between the busbars & wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming cable rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including I/C & O/G cable opening on bottom & at both sides including cable glands of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv box of any size/type complete all as specified & as directed.
5
-
-
... More
Notes for Item Nos 26 to 31:-
(i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer.
(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
-
-
-
... More
M&L for Repairs to feeder pillar box/LT panel etc, taking out old unserviceable and fixing of new hinges (if any) by welding/bolt nuts,addn/altn to MCCB enclosure cover with one incoming and No of out goings by grinding,cutting and painting all as shown and diretced, repairs to door lock by replacing unsv locks, extension of aluminium bus bars for incoming/outgoing MCCBs as per existing shapes and size, spray painting with two coats of approved grade & color synthetic enamel paint after scrapping incl preparation of old painted surfaces & fixing 02 nos (front & back) danger notice plate as per standard size complete all as specified and directed.
8
-
-
... More
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & Iron cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Note :-1) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
12
-
-
... More
Supply and fixing the name board Size 59 X 36 Inch including conneted item for fixing arragement all as specified ad directed by Engr- in- charge with stainsteel pole with supporting Steel frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed by Engr-Charge. (colour, specification menction in the boad desied by Engr in charge)
8
-
-
... More
M&L for preparation of old painted steel surfaces of outdoor/indoor type LT/HT Panels, Feeder Pillar/Junction boxes, Change-over Boxes etc. of any size/type etc. after cleaning of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. complete & applying one coat of synthetic enamel paint of approved colour & grade using spray gun & neatly writing distribution details (if applicable) and repair /replacement Hinges, and complete all as specified & as directed by the Engr-In-Charge.
30
-
-
... More
M&L for cutting grass , bushes, creepers, weeds, unwated plants/growths etc , in and arround the panel board , substation or any other location as directed by Engr in charge /GE and removing rubbish off the premises complete all as specifed and to the entire satisfication of the Engr-in-charge.
300
-
-
... More
M&L for straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 25 to 50 Sqmm 4/3.5 core incl earthwork, taking down, preparation of damaged cable incl testing complete all as specified & as directed by the Engr-In-Charge.
4
-
-
... More
Description all as per Item Sl No 38 here in above but suitable for Aluminium conductor cable of size 70 to 120 Sqmm 3.5 core.
4
-
-
... More
Description all as per Item Sl No 38 here in above but suitable for Aluminium conductor cable of size 150 to 185 Sqmm 3.5 core.
4
-
-
... More
Description all as per Item Sl No 38 here in above but suitable for Aluminium conductor cable of size 240 to 300 Sqmm 3.5 core.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements