Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Jan 2025
Closing Soon10 Feb 2025
Tender Amount₹ 16,80,000
Costs
EMD
₹ 33,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693936_1Tender No
87660CWEAFNTBMTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of R - 22 Refrigerent gas and charging in the AC plant installed at Hangar complete all as specified and directed.Note:- The gas shall be procured from original manufacurers or auth manufactures stockist/distributor/dealer only and GST voucher etc shall be submitted to Deptt.
80
-
-
... More
M & L for dismantling of hermatically sealed compressor of model No. ZR 57KC - TFD - 522, make - Copeland suitable for 5.50 TR plant for item no 1 and provn of new compresser of same make and model in the unit complete all as specified and directed.
Note:-The Compressor shall be procured from original manufacurers or auth manufacturers stockist/distributor/dealer only and Manufactures warranty certificate duly mentioned compressor make, Ser No model and GST voucher details etc shall be submitted to Deptt.
1
-
-
... More
M & L for dismantling of fan in the outdoor unit of capacity 8.75TR AC Plant for item no 1 and provn of new Fan, Single phase, 400 watts of existing capacity all as specified and directed.
3
-
-
... More
M & L for removing the blower motor of capacity 2 HP installed at Hangar for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing, shaft complete all as specified and directed.
3
-
-
... More
M & L in replacement of micro processor board [PCB] same as per exising in 8.75 TR package AC plant at Hangar including testing complete all as specified and directed.
1
-
-
... More
M & L for taking out the burnt out/unserviceable three phase 440 volts 32 Amps contactor from LT control panel, and supply and fixing the same capacity and model of the contactor complete all as specified and directed. Model ML-3 of makes L&T/Siemens/BCH.
4
-
-
... More
M & L for general servicing of 8.75 TR, Package type AC Plant Qty-03 sets of Blue star make at Signal section including carry out the following works: (a) Cleaning of return air filters. (b) Checking of blower fan belts alignment and serviceability.(c) servicing of electrical control panel board and its wiring of the plant.(d) Cleaning of drain lines.(e) Checking of leakage of gas.(f) Checking of pressure. Note:- 1) The above checks shall be carried out once in a month and the same shall be measured as one job. 2) If any refrigerent gas is required, the same shall be measured and paid separately as supply only against item No-20 here in after.
9
-
-
... More
M & L for Cleaning of indoor and outdoor Condenser coil / Evaporator coil as per manufacturers standard practice for item no 10 complete all as specified and directed.
Note :- The above checks shall be carried out once in a month and the same shall be measured as one job.
9
-
-
... More
M & L for vaccumising, dehydrating and carried out pressure test with nitrogen gas including ensuring that there is no leakage in the system for item no 10 complete for the above package units all as specifed and directed.
3
-
-
... More
Taking down exsisting glass wool insulation and M & L of 13mm Thick Thermal Insulation - Closed Cell Elastomeric Foam Nitrile Rubber Insulation With Class - O , Installation With Synthetic Rubber Adhesive to be Apply on the Surface of the Duct Inside and Fix these Insulation as per the Given Dimensions , Density 50 KG/M3 MAKE - Supreme Insuflex , Armasound, A-Flex,K-FLEX OR other equivalent make approved by GE
60
-
-
... More
M & L for dismantling of fan in the outdoor unit of capacity 8.75TR AC Plant for item no 10 and supply and fixing of new Fan, Single phase, 230 volts, 400 watts of existing capacity as per site requirement all as specified and directed.
2
-
-
... More
M & L for removing the blower motor of capacity 2 HP installed at signal sec for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified and directed.
3
-
-
... More
M & L in replacement of micro processor board [PCB] same as per existing in 8.75 TR package AC plant at signal sec including testing complete all as specified and directed .
2
-
-
... More
M & L for general servicing of 22 TR, Package type AC Plant Qty-02 Nos and 11TR Package type AC plant -02 Nos Make Blue star at Roopavani T-440 including carry out the following works: (a) Cleaning of return air filters. (b) Checking of blower fan belts alignment and serviceability.(c) servicing of electrical control panel board and its wiring of the plant.(d) Cleaning of drain lines.(e) Checking of leakage of gas.(f) Checking of pressure. Note:- 1) The above checks shall be carry out once in a month and the same shall be measured as one job. 2) If any refrigerent gas required the same shall be measured and paid separatelly as supply only against item No-20 here in after.
9
-
-
... More
M & L for Cleaning of indoor and outdoor Condenser coil / Evaporator coil as per manufacturers standard practice complete all as specified and directed for 22 TR AC Plant.
Note :- The above checks shall be carried out once in a month and the same shall be measured as one job.
9
-
-
... More
M & L for vaccumising, dehydrating and carrying out pressure test with nitrogen gas including ensuring that there is no leakage in the system complete for the above package units all as specified and directed for 22 TR AC Plant.
2
-
-
... More
Supply of R - 407C Refrigerent gas and charging in the AC plant installed at Signal Sectioin and Roopavani complete all as specified and directed.Note:- The gas shall be procured from original manufacurers or auth manufacturers stockist/distributor/dealer only and GST voucher etc shall be submitted to Deptt.
100
-
-
... More
M & L for dismantling of fan in the outdoor unit of capacity 22 TR -02 units and 11 TR-02 units AC Plant and provn of new Fan, Single phase, 230 Volts of existing capacity all as specified and directed.
1
-
-
... More
M & L for removing the blower motor of capacity 3/5 HP installed at Roopavani for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified and directed.
2
-
-
... More
M & L in replacement of micro processor board [PCB] in 22 TR -02 Units and 11 TR - 02 Units package AC plant including testing complete all as specified and directed .
1
-
-
... More
M & L for Descaling of condensor unit of capacity 35 TR by circulating dilute hydrochloric acid solution and cleaning the tubes with wire brush by removing the side cover till the tubes are thoroughly cleaned and re-circulating the fresh water after fixing the side cover including replacement of gasket set complete all as specified and directed.
3
-
-
... More
M & L for Dismantling the cooling tower of capacity 70 TR central AC plant installed at FMS bldg and draining out complete water, cleaning honey comb fins by castic soda and wire brush including cleaning the cooling tower tank and remove all algae from the basin, removing sediments from the all around cooling tower and GI pipes complete with replacement of 50mm float valve complete all as specified and directed. Note: The time between first and second cleaning shall be six month minimum.
2
-
-
... More
M & L for Painting of mono block pump set with motor and blower motor cooling tower motor of any capacity with two coats of red oxide and one coat of existing colour of synthetic enamel paint after cleaning and scrubbing complete with base and supports etc., all as specified and directed.
6
-
-
... More
M & L for vaccumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and bracing if required complete all as specified and directed for 35 TR AC plant.
3
-
-
... More
M & L for leak testing the plant by using nitrogen Gas up to 300 PSIG pressure and hold the same under high pressure upto 24 hours including necessary welding and bracing if required complete all as specified and directed for 35 TR AC plant.
3
-
-
... More
M & L for charging/topping up the refrigerant gas R-134A into the system, testing complete in FMS central AC plant all as specified and as directed.
200
-
-
... More
M & L for Dismantling and overhauling of Air handling unit of capacity 70 TR central AC plant installed at FMS and assembling, testing for following parts. (a) Inspect absolute filters, remove and clean by using vaccum cleaner and refix the same. (b) Clean cooling coil, applying grease for all motors, check and adjust belt tension if required, check condition of blower shaft, scroll, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system, check for noise and vibration. (c) Check healthy operation of controls and safety devices. (d) Air filters: Removal and fixing after cleaning by Air Blower and water.Note: The above checks shall be carried out once in a month and the same shall be measured as one job.
9
-
-
... More
Supply & Installation of Fresh Air Damper hand operated of size 2500 mm x 400mm as per exsisting GI sheet complete all as specified and directed.
1
-
-
... More
Supply & Installation of return Air Damper hand operated of size 1200 mm x 1200mm as per exsisting GI sheet complete all as specified and directed.
1
-
-
... More
Taking down glass wool insulation and M & L for 13mm Thick Thermal Insulation - Closed Cell Elastomeric Foam Nitrile Rubber Insulation With Class - O, Installation with synthetic rubber adhesive to be applied on the Surface of the duct inside and fix these Insulation as per the given dimensions, density 50 KG/M3 complete all as specified and directed.
60
-
-
... More
M & L for dismantling Monoblock pump set 10 /5 HP model UP50/30 removing scales cleaning, heating varnishing of motor winding, servicing the pump sets by repalcing the worn out bushes, bearings, gland rope, gland mounting assembly, Gun metal Impeller, bolts & nuts, etc reassembling the complete pump set including testing and commissioning complete all as directed.
3
-
-
... More
M & L for dismantling burnt out three phase, 50 C/S capacity 10 / 5 HP motor for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified and directed.
3
-
-
... More
M & L for dismantling burnt out three phase, 50 C/S capacity 60 Hp/45 KW compressor motor for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified and directed.
1
-
-
... More
M & L for dismantling of 60 HP / 45 KW compressor including taking down unserviceable parts and refixing new parts whererever necessary complete all as specified and directed after pumping down complete system and collecting the refrigerant into condenser, compressor oil into clean container & disconnecting the compressor from suction & discharge side and including leak testing of compressor after reassembling the parts, recharging/filling retrieved oil & gas, replacement of belt if required and testing upto satisfactory cooling performance complete all as specified and directed. Note:-1) Spare parts, refrigerent gas and compressor oil for top up if required shall be measured and paid for supply only in respect item of this schedule for 35TR. 2) metal filling, grinding, polishing spring, washer, quarter and consumable items such as grease, cotton waste etc are deemed to be included in the quoted rate.
1
-
-
... More
S & F metal coupling along with rubber coupling of size L-100 complete suitable for 5 Hp pump all as specified and directed.
3
-
-
... More
S & F metal coupling along with rubber coupling of size L-110 complete suitable for 10 Hp pump all as specified and directed.
2
-
-
... More
S & F of 'V' belt SPB 3350/B-92/B-76 complete all as specified and directed. Make; Fenner or equivalent.
10
-
-
... More
Supply and replacement of water pressure switch as per existing all as specified and directed.
2
-
-
... More
M & L of Removing / replacement of new high pressure cut off switch for gas line complete all as specified and directed.
2
-
-
... More
M & L for replacement of filter for drier unit of 35 TR complete all as specified and directed. Make ALCO D-48 or equivalent.
3
-
-
... More
S & F in replacement PCB control board intellisys complete all as specified and directed. Make: -soft hard suitable for 70 TR central AC plant
1
-
-
... More
M & L in replacement of contactor of model MNX 18 complete with NO all as specified and directed
2
-
-
... More
M & L in replacement of contactor of model MNX 12 complete with NO all as specified and directed
2
-
-
... More
M & L in replacement of contactor of model MNX 09 complete with NO all as specified and directed
2
-
-
... More
M & L in replacement of contactor of model MNX 25 complete with NO all as specified and directed
2
-
-
... More
M & L for Replacement of PVC honey comb fins as per existing size at FMS AC plant complete all as specified and directed
85
-
-
... More
M & L for drain out old compressor oil from the compressor and cleaning compressor unit refilling and supply only new compressor oil, top up of required level, type Poly oil-Mobil suitable for reciprocating type compressor of 35 TR capacity 03 No's Make: Zed plus Model: Reefrigeration oil-68 or equivalent complete all as specified and directed Note:- The compressor oil shall be procured from original manufacturers or auth manufactures stokiest /distributor/dealer only and GST voucher etc shall be submitted to Deptt.
80
-
-
... More
M & L in replacement of star delta starter as per site requirement suitable for 3 phase motor of capacity 5 HP complete all as specified and as directed.
2
-
-
... More
M & L in replacement of star Delta starter as per site requirement suitable for 3 phase motor of capacity 10 HP complete all as specified and as directed.
1
-
-
... More
S & F in replacement of single phasing preventer (Make Minilac model VSPI 3 ph 415 volts or equivalent) all as specified and directed.
5
-
-
... More
M & L in replacement of butterfly valve of size 100 mm complete all as specified and directed.
4
-
-
... More
M & L in replacement of butterfly valve of size 50 mm complete all as specified and directed.
2
-
-
... More
S & F for gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25mm bore complete all as specified and directed.
3
-
-
... More
M & L for replacement of AHU of central AC plant pre air filters, dry type, washable, rated air flow capacity 17750 CFM 90% efficiency, down to particle 10 micron max operating temp of -50 deg C frame made of aluminium box type synthetic woven fabric with non woven polyester and one layer of aluminiuam expanded metal as reinforcement throughout the length of the media with PU sealant complete all as specified and directed of following sizes Make: Airtech/Spectrum or equivalent.
(a) Filter Sizes 500 x 500 x50 mm : capacity 900 CFM @4 mmwc
14
-
-
... More
All as per item No 57 above but for filter Sizes 600 x 400 x50 mm : capacity 900 CFM @4 mmwc
2
-
-
... More
All as per item No 57 above but for filter Sizes 500 x 400 x50 mm : capacity 900 CFM @4 mmwc
4
-
-
... More
M & L in replacement of AHU of central AC plant fine air filters, dry type, washable, rated air flow capacity 17750 CFM 95% efficiency, down to particle 3 micron max operating temp of -50 deg C, frame made of aluminium flange type, two layers of synthetic woven fabric with 10mm G3 media and one layer synthetic woven fabric aluminiuam tubes rgidly fitted to the casing using PPCP studs with PU sealant complete all as specified and directed of following sizes: Make: Airtech/Spectrum or equivalent.
(i) Filter Sizes 530 x 430 x150 mm: capacity 1000 CFM @7 mmwc
28
-
-
... More
All as per item No 60 above but for filter Sizes 430 x 430 x 150 mm: capacity 850 CFM @7 mmwc
15
-
-
... More
All as per item No 60 above but for filter Sizes 430 x 330 x 150 mm: capacity 650 CFM @7 mmwc
4
-
-
... More
M & L for replacement of AHU of central AC plant deep pleat Hepa air filters, (Normal Flow type) dry type, washable, rated air flow capacity 17750 CFM 99.97%, down to particle 0.3 micron max operating temp of -50 deg C frame made of aluminium flange type, micro glass fiber media with PU sealant complete all as specified and directed of following sizes: Make: Airtech/Spectrum or equivalent.
(i) Filter Sizes 430 x 430 x 305 mm : capacity 700 CFM @18 mmwc
8
-
-
... More
All as per item No 63 abvoe but for filter Sizes 520 x 420 x 305 mm:capacity 1000 CFM @18 mmwc
2
-
-
... More
All as per item No 63 above but for filter Sizes 425 x 425 x 305 mm: capacity 650 CFM @18 mmwc
5
-
-
... More
All as per item No 63 above but for filter Sizes 420 x 320 x 305 mm: capacity 500 CFM @18 mmwc
3
-
-
... More
M & L for Dismantling the central AC plant AHU fan motor / cooling tower fan motor of any make of capacity 20/12.5HP capacity servicing by over hauling, cleaning, greasing, lubricating, re assembling, painting the angle base and testing including replacing the following items all as specified and directed. (a) Ball bearing set Make : SKF or equivalent, (b) Bearing sleeve (c) Terminal connector any size any capacity (d) M.S. metal shaft (e) Gasket any size any capacity (f) MS bolts, nut and washer any sizes suitable flange any size any capacity, foundation bolt, nut
3
-
-
... More
M & L for painting of central type AC plant 35 TR complete with Chiller Unit compressor unit outer side colour two coating of existing synthetic enamel paint after cleaning and scrubbing complete and writting of MES NO all as specified and directed.
3
-
-
... More
M & L for Painting of condensor pipe line inlet and outlet (length upto cooling tower basin) and chiller pump pipe line inlet and outlet (length up to plant room wall) of any size, one coat of red oxide primer and two coating of existing colour of synthetic enamel paint after cleaning and scrubbing including marking and numbering complete all as specified and directed .
20
-
-
... More
M & L in replacement of water pressure gauges with adoptor (circular type) 100 mm dia with brass adoptor 15 mm 0-200 Kg/CM2 inlet only complete all as specified and directed.
9
-
-
... More
M & L in replacement of temperature gauge circular type 100 mm dia with brass adoptor 15 mm inlet only with temp range 0 to 50 degree centigrade complete all as specified and directed.
6
-
-
... More
S & F MCCB, 4 poles 415 Volts, 100 Amps, 36 KA, 50 Hz, AC, fixed thermal and fixed magnetic type with suitable size lugs and testing complete all as specified & directed.
2
-
-
... More
S & F MCCB, 4 poles 415 Volts, 160 Amps, 36 KA, 50 Hz, AC, fixed thermal and fixed magnetic type with suitable size lugs and testing complete all as specified & directed.
1
-
-
... More
M & L for PCC 1:4:8, type D-2, (using 40 mm graded stone aggregate) for foundation, filling and mass concrete complete all as specified and directed.
1
-
-
... More
Material and labour for general servicing of 17 TR, Air Cooled Package type AC Plant Qty-3 Nos Make:-Carrier at CPT Bldg including carried out the following works:-
a) Cleaning of return air filters
b) Checking of blower fan belt's alignment and serviceablity
c) Servicing of electrical control panel board and its wiring of the plant
d) Cleaning of drain lines
e) Checking of leakage of Gas
f) Checking of pressure Note:- The above checks shall be caried out every months.
9
-
-
... More
Cleaning of indoor and outdoor Condenser coil / Evoprator coil as per manufacturers standard practice complete all as specified and directed.
Note:- The above checks shall be caried out once in months
9
-
-
... More
M & L for vaccumising, dehydrating and carry out pressure test with nitrogen gas including ensuring that there is no leakage in the system complete for the above Air Cooled package units at CPT Bldg all as directed by Engr-in-charge.
4
-
-
... More
M & L for dismantling of fan in the outdoor unit of capacity 17 TR - 03 Units AC Plant, and provn of new fan, Single phase,230volts of existing capacity all as specified and directed.
2
-
-
... More
Material and labour for removing the blower motor of capacity 3/5 HP installed at CPT Bldg for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper /tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified.
2
-
-
... More
M & L for in replacement of micro processor board [PCB] in 17 TR -03 Units package AC plant including testing all as directed .
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%