Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Dec 2024
Closing Soon31 Dec 2024
Tender Amount₹ 49,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling in using excavated soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as directed.

318

-

-

... More
Supplying and laying of burnt Fly ash bricks class standard size for protection of cable as directed.

23976

-

-

... More
Fine Seived excavated dry Soil laid to the required width of trench at bottom and top of cable as cushioning all as specified and as directed.

243

-

-

... More
Dismantling & taking down Old Unsv pole of any type and any size/make etc complete all as specified and as directed

5

-

-

... More
Supply and Fixing of Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap,bolts,nuts,screws,9 Mtr long, type 410 SP - 31,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed.

5

-

-

... More
Demolition of existing old concrete and M & L for Plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate for coping to pole foundation including necessary form work with fair finished surface all as directed.

65

-

-

... More
Demolition of existing old concrete and M & L for Plain Cement concrete 1 : 4 : 8 type C1 using 20 mm graded stone aggregate for pole foundation, filling and mass concrete all as specified.

7

-

-

... More
Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable size of following sizes : Note:- (i) Jointing kit will be measured and paid separately under relevant item. (ii) Excavation, returning refilling will be measured seperately.

-

-

-

... More
(a) LT UG Cable 2/ 3.5/ 4 core 6 Sqmm to 3.5 core 50 Sqmm

600

-

-

... More
(b) LT UG Cable 3.5 core 70 Sqmm to 3.5 core 300 Sqmm

570

-

-

... More
Taking down old UNSV UG Cables and taking as schedule of credit including, Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed of following sizes:-

-

-

-

... More
(a) LT UG Cable 2 core 10 sqmm .

200

-

-

... More
(b) LT UG Cable 4 core 16 sqmm .

1100

-

-

... More
(b) LT UG Cable 4 core 16 sqmm .

1000

-

-

... More
(b) LT UG Cable 4 core 25 sqmm .

620

-

-

... More
(b) LT UG Cable 3.5 core 35 sqmm .

600

-

-

... More
(b) LT UG Cable 3.5 core 50 sqmm .

600

-

-

... More
(b) LT UG Cable 3.5 core 70 sqmm .

600

-

-

... More
(c) LT UG Cable 3.5 core 95 sqmm .

500

-

-

... More
(d) LT UG Cable 3.5 core 120 sqmm .

120

-

-

... More
(d) LT UG Cable 3.5 core 150 sqmm .

120

-

-

... More
(d) LT UG Cable 3.5 core 185 sqmm .

120

-

-

... More
Supply and Fix in repairs for cable Jointing kit 1.1 KV grade cable for Straight Through Joint complete with jointing material heat Shrink type and accessories for 3.5/4 core XLPE armoured Aluminium conductor cable complete all as specified and as directed of following sizes:-

-

-

-

... More
(a) 3.5/ 4 core 10 to 16 Sqmm

4

-

-

... More
(b) 3.5/ 4 core 25 to 50 Sqmm

5

-

-

... More
(b) 3.5/ 4 core 35 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 50 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 70 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 95 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 120 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 150 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 185 Sqmm

2

-

-

... More
(b) 3.5/ 4 core 240 Sqmm

1

-

-

... More
Repair and welding work the existing panel board door and provided hinges for door, if necessary and lock arrangement with provision of pad lock with keys and cleaning the welding surfaces by rubbing and polishing with two coat of synthetic enamel paint all is specified and directed.

8

-

-

... More
Taking down old UNSV Main switch/ Switch fuse Unit and taking as schedule of credit including Supply & Fix following MCCBs Thermal magnetic release type directly fixing to main board/panel /walls including new alteration to panel with all necessary accessories all as specified and directed.

-

-

-

... More
(a) MCCB 63A , 4 pole , 16 KA

4

-

-

... More
(b) MCCB 100A , 4 pole , 16 KA

4

-

-

... More
(c) MCCB 125A , 4 pole , 16 KA

4

-

-

... More
(d) MCCB 160A , 4 pole , 35 KA

4

-

-

... More
(d) MCCB 200A , 4 pole , 35 KA

2

-

-

... More
(d) MCCB 250A , 4 pole , 35 KA

2

-

-

... More
(d) MCCB 320A , 4 pole , 35 KA

2

-

-

... More
S&F in replacement for factory made sheet metal encloser (junction panel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 75X60X30cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 600 Amps suitable for one incoming and 5 out going feeders, mounted on insulators including disconnection of cable from the burnt bus bar and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs all as per existing Make: Standard/L&T/Havells as per site

2

-

-

... More
S&F in replacement for aluminium tube terminals (cable lugs) of size 10/16 Sqmm

80

-

-

... More
S&F in replacement for aluminium tube terminals (cable lugs) of size 25 Sqmm

80

-

-

... More
S&F in replacement for aluminium tube terminals (cable lugs) of size 35 Sqmm

90

-

-

... More
S&F in replacement for aluminium tube terminals (cable lugs) of size 50 Sqmm

90

-

-

... More
Supply & Fix 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 200 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.

1

-

-

... More
Supply & Fix 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 320 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.

1

-

-

... More
Preparation of old painted surface of electric poles mild steel tubular type 7.5 to 11 Mtr long any type / make / model above ground level including cross arms, clamps etc and applying one coat with aluminium paint on pole, cross arms, clamps, etc complete all as specified and directed.

400

-

-

... More
Supply and lay GI tubes, 'light grade' galvanised, with all fittings; of bore of tube 50mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed

30

-

-

... More
Supply and lay GI tubes, 'light grade' galvanised, with all fittings; of bore of tube 40mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed

72

-

-

... More
S&F in repairs Bldg security Light Endura PEARL 30 W MP Bldg Sec lights New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP 66 roadway luminarie with high power LEDs as light source and electronic driver of Lamp type:30W LED 6000K all as specified and as directed. Make:- Bajaj :ENXT P 30L WH SYPCSD / Havells:ENDURACITYLITEPLATPLUSSL30WLED 757SASYBOPC/ Wipro:LRO2-331-XXX-57-XX

15

-

-

... More
S&F LED street light fittings 70 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories including taking out existing UNSV old one complete all as specified and as directed.Make:-Bajaj :ENXT P 72L WH CRPCSD / Havells:ENDURACITYLINEARNEO SL 70WLED 757PASYBOTG/ Wipro:LRO7-781-XXX-57-XX

20

-

-

... More
S&F LED street light fittings 90 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories including taking out existing UNSV old one complete all as specified and as directed. Make:-Bajaj :BRTFG 90W LEDCR / Havells:ENDURAPEARLPLUS SL 90WLED 757PASYTOPCASTHO/ Wipro:LRO7-102-XXX-57-XX

20

-

-

... More
S&F LED street light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories including taking out existing UNSV old one complete all as specified and as directed. Make:-Bajaj :BRTFG 120W LEDCR / Havells:ENDURAPEARLMAG SL 120WLED 757PASYTOPGASTHO/ Wipro:LRO7-132-XXX-57-XX

20

-

-

... More
S&F LED Flood Light fittings 50 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories including taking out existing UNSV old one complete all as specified and as directed.Make:- Bajaj :BJFL 50W LED I / Havells:JETAQUAN TOP PLUSFLP50W 757SYMLENS

25

-

-

... More
S&F LED Flood Light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories including taking out existing UNSV old one complete all as specified and as directed.Make:- Bajaj :BJFL 120W LED I / Havells:JETAIRISFLS 120W 757SYMLTG/ Wipro:LF20-132-XXX-57-G2

10

-

-

... More
S&F in repairs LED Bollard Light Fitting 9 Watts long life LED module complete with electroninic driver suitable for 220/240 volt AC supply with IP 65 protection including 5 year warrenty along with warranty certificate from manufacturer all as specified and as directed.Make:- Bajaj :BGBOL6059W LED WW / Havells:BAMBOO BLS8WLED 830PSYMTOPC/ Wipro:LB14-131-XXX-65-05

15

-

-

... More
Supply installation ,testing and commissioning of LED Post Top Latten Light fitting long life LED module complete accessories as recommended by manufacturer suitable for 220/240 volt AC supply with IP 65 protection including taking out existing UNSV old one and necessary connection etc all as specified and as directed.Make:-Bajaj :BGCTN 25W LED WW / Havells:RUBY PT 25W LED830SSYMTOPC/Wipro:LP07-431-XXX-57-CL

8

-

-

... More
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sq. mm nominal cross section in service connections incl necessary connection etc complete all as specified and directed.

400

-

-

... More
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 6 sq. mm nominal cross section in service connections etc complete all as specified and directed.

400

-

-

... More
Supply and Fix in replacement of Power Contactor 4 pole 200A including all necssary connections etc Amps complete all as specified and directed.

2

-

-

... More
Supplying and fixing in replacement of pole mounted Sheet Moulded Compound (SMC) Box weather proof type with hinged type door off white color of size 240x130x110 mm comprising of 1 No MCB 6A and 1 No neutral link complete fixed on pole with suitable clamps, bolts and nuts all as specified and as directed. Make: Sintex/Hensel

450

-

-

... More
Supply and laying in replacement of or fixing or passing through pipe, 1100 volts grade heavy duty PVC Insulated and FR PVC Round sheathed copper conductor (flexible) 3 core 1.5 Sqmm served with an inner sheathing of sheathed nominal cross section including suitable PVC conduit and clamp and all necessary arrangements all as specified and as directed.

820

-

-

... More
Supply and fix pole mounting bracket for single street light fitting fabricated with GI pipe medium grade 40mm dia 2 mtr long bend to shape and double clamped with fabricated MS clamp and fixed complete on side of steel tubular pole with bolts and nuts including painting complete all as specified and as directed.

13

-

-

... More
Supply and fix in replacement of Digital Timer programmable Time Switch with all necessary connection complete all as specified and as directed.

5

-

-

... More
Supply and fix in replacement of control contactor with in built auxillary contacts 9 NO/NC combination with maximum 6 NC contact with all necessary connection complete all as specified and directed.

8

-

-

... More
Material and labour for cutting and cleaning all branches of trees on Street Light poles and maintaining the street Light fittings minimum 3 mtr all around tree branches at OTA area all as specified and directed. Note :- Span shall be measured along the direction of Poles.The tree cutting will be done within 3 months.

200

-

-

... More
Supply & Fixing in replacement of LED driver for LED light fittings of Bollard / Bldg Security of any type and any make upto 40 Watts

100

-

-

... More
Supply & Fixing in replacement of LED driver for LED light fittings of Street Light of any type and any make upto 70 to 120 Watts

190

-

-

... More
Material & Labour for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel strip 25X4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.

3

-

-

... More
Finding and rectification of electrical fault by Checking of external/internal elect supply feeder, street light feeder,OH conductors /under ground cables using elect tools, equipments and safty devices after arranging elect shut down of feeders from sub station to remove elect faults like tightning of loose connection,removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid seperately or supplied by department. (iii) Rate including hire of HT fault Locaterany other tools/equipments and Earth Work. works should be completed with in 12 hrs

59

-

-

... More
Supply & Fix in repairs 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 200 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.

1

-

-

... More
Supply & Fix in repairs 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 320 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.

1

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 10 Sqmm

30

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 16 Sqmm

30

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 25 Sqmm

30

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 50 Sqmm

25

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 70 Sqmm

30

-

-

... More
Supply & Fix in repairs aluminium tube terminals(cable lugs) of size 95 Sqmm

20

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 120 Sqmm

20

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 150 Sqmm

20

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 185 Sqmm

15

-

-

... More
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 240 Sqmm

10

-

-

... More
Supply and Fix in replacement of Four pole 40 to 63 Amps 10 KA C curve series ISI marked including necessary connections compete all as specified and as directed.

7

-

-

... More
Supply and fix inreplacement of push buttons with 1 NO / 1 NC, screw type for operation of capacitors all as per sample available at sub stations including necessary electric connections and testing including dismantling unserviceable push buttons (start/stop button) from the power factor capacitor panel boards complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of LED type three phase Voltmeter ,all as directed.

6

-

-

... More
Supply and fix in replacement of LED type three phase Amper meter with suitable CTs and all as directed.

6

-

-

... More
Supply and fix in replacement of selector switch, 3 position, for volt meter and ammeter suitable for three phase supply including necessary electric connection and testing including taking out unserviceable selector switches from the panel board complete all as specified and directed.

4

-

-

... More
Supply and fix in repairs, LED indicating lamps of red/yellow/ blue/green /amber with bulbs including connection and testing complete all as specified and directed.

18

-

-

... More
M&L for replacement of lock assembly with two nos keys for old/existing LT panel board any type/size complete all as directed

1

-

-

... More
S & F inrepairs locking arrangement with aldrop bolt set complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified.

1

-

-

... More
Supply only first-aid box with 26 Numbers of items as per the BOCW Act.

2

-

-

... More
S&F in repairs of steel tubes light grade of size 80 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.

12

-

-

... More
S&F inrepairs of steel tubes light grade of size 50 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.

18

-

-

... More
S&F in repairs of steel tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in treanches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.

18

-

-

... More
Supply and laying inreplacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sq. mm nominal cross section in service connections incl necessary connection etc complete all as specified and directed.

300

-

-

... More
Supply and laying inreplacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 6 sq. mm nominal cross section in service connections etc complete all as specified and directed.

300

-

-

... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. Make:- Jyoti/Denson or equilvent

3

-

-

... More
Supply and fix /erect/ ground LT cable route indicator made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage, size of cable and route indicator fixed with angle iron of size 25 x25 x3 mm thick, 50 cm long embedded in PCC 1:2:4 type B1 of size 30 x 30 x 30 cm in ground all as specified and as directed

20

-

-

... More
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed. Note : (i) Necessary eqpt and safety mesures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate.

5

-

-

... More
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete , necessary earthwork as required all as specified and as directed. Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate

5

-

-

... More
M&L for prepartion of old painted surfaces of LT panel/Feeder piller box of any type including welding of damaged doors outdoor/indoor including removing old paint with scrubing and applying one coat of synthetic emanel paint of shade as per existing over a coat of red oxide primer,with electrically operated spray machine, complete all as specified and directed.

5

-

-

... More
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed

5

-

-

... More
M&L for checking of earth pit results, cleaning pit area complete, pouring of salt water as reqd in pit for maintaning of pit resistance up to less than 3 ohm complete all as specified and directed.

5

-

-

... More
Supply and spreading of stone metal graded aggregate of size 40 mm in transformer yard at various locations in a proper level complete all as directed at site.

30

-

-

... More
M&L for Broken stone or Boulders hardcore of gauge not exc. 63mm, deposited, spread and levelled in layer not exc. 150mm thick, watered and rammed to a true surface, complete all as spacified and directed.

30

-

-

... More
Material & Labour for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to steel strip 25X4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.

6

-

-

... More
Supply and fix in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above/below ground level including taking down old complete all as specified and as directed.

20

-

-

... More
Complete servicing, overhauling, repairing, cleaning, oiling with setting of tripping mechanism of following Air Circuit Breakers (ACBs) including submission of service & test reports. The servicing to be done by authorised service provider of manufacturer. The details are placed at "Scope of work" as given under.Note :Minimum spares/lubricants and tools required for the job should be included in the coated rates . a)Air Circuit Breaker(ACB) 415 volts of capacity 630 amps to 1000 Amps 50Hz any type or make or all asper existing SCOPE OF WORK :-

10

-

-

... More
i) Moving arcing contacts shall be checked. Cleaning of breaker with CRC-226 ii) Removal of old grease and re-greasing the same with recommended grease. iii) Check condition of arcing contact and gap between fixed and iv) Checking the reset mechanism, tripping of breaker through push button v) Checking tripping of ACB through protection release vi) Tripping of ACB manually through volt metric release. vii) Checking and adjust freeness of DN and volt metric release trip rod viii) Checking presence and proper tightening of hardware. ix) Checking presence of all circlips x) Checking condition and alignment of jaw contact with cradle terminals xi) Checking condition of ACB wiring and replace if required xii) Checking and adjusting gap between hylam sheet and side plate xiii) Checking proper closing of all poles together xiv) Checking working of anti pumping device. xv) Checking alignment of SIC and it’s operation xvi) Checking scrapping earth alignment xvii) Checking condition of arc chutes xviii) Checking U/V release pick up and drop off xix) Checking ACB tripping through shunt release xx) Checking continuity and proper changeover of aux contact block xxi) Checking of release by secondary injection for O/L, S/C, E/F xxii) Setting of release as per the load xxiii) Checking the healthiness of CTs

-

-

-

... More
Supply and fixing in replacement of following items of Air Circuit Breaker (ACB) 415 volts 630 to 1000 Amps 50Hz,any type or make or all asper existing

-

-

-

... More
a) Closing Relay

2

-

-

... More
b) Terminal Adaptors (4 terminals per Phase)

3

-

-

... More
c) Relay Module

3

-

-

... More
d) Shunt trip Release

3

-

-

... More
e) Auxiliary Switch

3

-

-

... More
f) Arc Chutes

3

-

-

... More
g) Trip Push Buttons

4

-

-

... More
h) ACB Position Indicator

3

-

-

... More
Taking down old u/s pillar panel board and Supply, Fabricate, install, connect, test and commission LT electrical Feeder Piller panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates,front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable for 800Amps as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination with suitable glands , complete all as specified and comprising of the followings Incoming & Outgoing:- Note : Old Unservicable Panel Board alongwith complete accessories to be deposited in AGE E/M store yard GE STM

-

-

-

... More
(a) ACB with Microprocessor Release IPR 1 + (4 Pole) 630A-01 No (Incoming) Make: Havells /Siemens / Legrand/Schneider (b) ON Load Change over Switch 320A-01 No (c) MCCB, 4 pole 200 A,35KA-03 Nos (d) MCCB, 4 pole160 A, 25 KA-03 Nos (e) MCCB, 4 pole125 A, 25 KA-04 Nos (f) Multi function Meter with CT & PTs-01 No (g) Phase indication lamps - 9 Nos. (h) All MCCBs are Panel mounted with handle operated

1

-

-

... More
Dismantling the existing squirrel gauge induction motor, rewinding with super enamelled copper winding of appropriate gauge and quality and insulated with varnish after removal of burnt out winding from slots with emery paper, including replacement of worn out bush, bearing, shaft metalling / grinding, reassembling and testing of capacity 7.5 HP complete all as specified and directed.

3

-

-

... More
Dismantling the existing squirrel gauge induction motor, servicing by overhauling, cleaning, greasing, lubricating,replacing wornout spares,reassembling and testing of capacity upto 7.5 HP complete all as specified and directed. It includes transport to workshop for repair for repair and return back to site fixing the motor connecting to electrictal supply , testing and commising inclusive of testing and commissioning complete all as specified and directed. Note:- (i) Any other small spares/ parts required for the job will be supplied and utalised for the job without any extra cost. (ii) Spares as required shall be measured and paid separatly as supply only under respective items. (iii) The labour element involved in replacing of parts shall deem to have been included in quoted rates of above item.

2

-

-

... More
Supply only DOL starter with single phase preventer of suitable capacity with all accessories required as per site incl all necessary wiring, connection etc. complete all as specified and directed.

5

-

-

... More
Supply only ball bearing complete all as specified and directed.

3

-

-

... More
Supply only shaft assembly with accessories complete all as specified and directed.

3

-

-

... More
Supply only pully bearing complete all as specified and directed.

3

-

-

... More
Supply only terminal connector of suitable size complete all as specified and directed.

4

-

-

... More
Supply only mild steel Nut, bolt & washer of suitable size complete all as specified and directed.

24

-

-

... More
Preparation of surface by removing dust, emery paper, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint existing shade/colour of Squirrel gauge induction motor complete all as specified and direced.

12

-

-

... More
Supply only mild steel foundation Bolts, nuts and washers of suitable size as per site reqmt complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of Battery Pack 30AH for LED Solar Street light including necessary electric connection and testing including taking out unserviceable Battery pack complete all as specified and directed.

1

-

-

... More
Supply and fix inreplacement 30W PIR sensor for LED Solar Street light including necessary electric connection and testing including taking out unserviceable PIR Sensor complete all as specified and directed.

3

-

-

... More
Supply and fix inreplacement LED driver capacity of 40 watts suitable for LED Solar Street light including necessary electric connection and testing including taking out unserviceable LED drive complete all as specified and directed.

6

-

-

... More
Material and labour for cutting and cleaning all branches of trees on Street Light poles and maintaining the street Light fittings minimum 3 mtr all around tree braches at OTA area all as specified and directed. Note :- (i)Span shall be measured along the direction of Poles. (ii) The Item shall be operated 3 times in the entire period of the contract and the measurement will be taken one time for payment after completion of contract.

90

-

-

... More
Cutting unaxious green growth and wild grass by Manual Labour or by Machine at Electric /DG Set supply Installation premises, around pole,Two pole Structure, Four Pole Structure along the boundary, Fencing etc., including removing rubbish from the Site of work and depositing where directed not exc 100 metre from the starting point, complete all as specified and as directed.

500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.