Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 18,50,000
Costs
EMD
₹ 37,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
8447 Repair/maintenance Of Summer Cooling Appliances At Sess Palayamkottai Under Ge Tirunelveli
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694518_1Tender No
GE/TVL/8447/E8 of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(u) BMS Card
(v) Temperature Sensor - sonda
(w) Main Incoming Breaker (within the unit)
(x) MCB (within the unit)
(y) Brazing (optional)
(z) Humidity Temperature Sensor
(aa) Fan Speed Controllers
(ab) Attending the Break down call
(ac) 4 Quarterly PPM
-
-
-
... More
Material and labour for fixing the following items for 3 X VRF type 17 TR PAC Make - Precision, Model No DATATECH UEDA 100.4 HH installed at ISRO, Tirunelveli including taking down the unserviceable spares complete all as specified and directed:-
-
-
-
... More
(a) PCO Controller, part code - MICA133AYY
2
-
-
... More
(b) EVD, part code - MICA168A
2
-
-
... More
(c) Air Filters
2
-
-
... More
(d) Filter Driers
4
-
-
... More
(e) Refrigerant
20
-
-
... More
(f) Compressor oil
2
-
-
... More
(g) Nitrogen Cylinder
10
-
-
... More
(h) Return/ Supply Air damper
2
-
-
... More
Supply and fixing the following for 1.5/ 2.0/ 3.0 Ton capacity Hiwall/ cassette/ split type ACs including testing and commissioning etc complete all as directed by Engineer-in-Charge.
-
-
-
... More
(a) Starting Capacitor 80/100 MFD.
20
-
-
... More
(b) Running Capacitor 45 MFD.
25
-
-
... More
(c) Relay Assembly (Make: SRI RAM).
18
-
-
... More
(d) Over load protector (O L P).
10
-
-
... More
(e) Thermostat.
14
-
-
... More
(f) Air filters.
6
-
-
... More
(g) Transducers
10
-
-
... More
(h) Blower with circular leaf.
2
-
-
... More
(j) Fan capacitor.
17
-
-
... More
(k) Cabinet wiring Kit .
4
-
-
... More
(m) PVC insulated, sheathed 3-core, 2.5Sqmm copper cable
55
-
-
... More
(n) Steiner tube (copper)
10
-
-
... More
(o) Non Return valve
15
-
-
... More
(p) Capillary tube (copper)
10
-
-
... More
(q) PCB indoor/ outdoor for capacity 1.5 TR
12
-
-
... More
(r) PCB indoor/ outdoor for capacity 2.0 TR
8
-
-
... More
(s) PCB indoor/ outdoor for capacity 3.0 TR
5
-
-
... More
Taking down, checking for serviceability and supply and fix new compressor for the following ACs including first filling of Oil, cleaning the refrigeration system/pipe before installing with CO2 and charging refrigerant gas as required, providing/refixing NRV if required for further gas top up and re-fixing in the position including testing complete all as specified and directed
-
-
-
... More
(a) Split AC 1.5 Ton capacity
5
-
-
... More
(b) Split/ cassette AC 2.0 Ton capacity.
5
-
-
... More
(c) Hiwall Split AC 2.0 Ton capacity.
3
-
-
... More
(d) Hiwall Precision Split AC 3.0 Ton capacity.
3
-
-
... More
Material and labour for fixing the following MCBs in the existing feeder pillar box including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar complete as specified and directed.
-
-
-
... More
(a) MCB TP, 25 to 63 Amp, 415V 10 KA, 'C' Series
7
-
-
... More
(b) MCB TP, 16 to 32 Amp, 415V 10 KA, 'C' Series
10
-
-
... More
(d) MCB SP, 6-32 Amp, 240V 10 KA, 'C' Series
20
-
-
... More
Supply and fixing outdoor Fan motor suitable for condenser unit of split/ cassette/ Hiwall ACs of capacity 1.5TR/ 2 TR/ 3 TR complete with all accessories and fixing in position and testing the unit as directed by Engr-in-charge.
10
-
-
... More
Taking down existing worn out fan/ blade from outdoor unit of ACs and supply and fix new heavy duty PVC/ metallic fan/ blade of same size with standard manufacturer specification including testing and commissioning complete all as directed by Engineer-in-Charge.
13
-
-
... More
Material and labour for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SP MCB including removal old unsv one complete all as specified .
15
-
-
... More
Supply and fixing for copper pipe of required size for 1.5/ 2.0/ 3.0 Ton capacity Hiwall/ cassette/ split type ACs complete all as specified and directed by Engr-in-charge.
20
-
-
... More
Taking down refrigerant of 1.5/ 2.0/ 3.0 Ton capacity Hiwall/ cassette/ split type ACs by dismantling, checking for leakages at various places and fixing the indoor and outdoor units complete with charging suitable refrigerants and making connection complete all as specified and directed by Engr-in-charge.
(Note : - Spare parts replaced shall be measured and paid separately under relevant items.)
6
-
-
... More
M&L for circuit/ sub main wiring with two single core 1100 V grade conforming to IS 694 PVC insulated unsheathed cables 4 Sq mm multi stranded copper conductor drawn through PVC rigid conduit in surface/ recessed with an earth wire of one run 4 sqmm copper wire earth continuity conductor complete all as specified and directed by Engr-in-charge.
95
-
-
... More
Supply and fix PVC flexible drain pipe suitable for 1.5/ 2.0/ 3.0 Ton capacity Hiwall/ cassette/ split type ACs complete all as specified and directed.
75
-
-
... More
Taking down burnt out MCCBs and supply and fix new moulded case circuit breakers of following capacity in the existing feeder Pillar box with new bolts and nuts including connecting the incoming and out going cables by using suitable cable glands complete as specified and directed.
-
-
-
... More
(a) MCCB 3 pole 415V fixed type 250 Amps 36 KA
2
-
-
... More
(a) MCCB 3 pole 415V fixed type 25 to 100 Amps 36 KA
6
-
-
... More
M&L for dismantling of electric driven horizontal induction motor of capacity upto 5.0 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed.
Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
6
-
-
... More
All as per srl item no 14 here-in-above but for 7.5 HP capacity.
4
-
-
... More
Servicing/overhauling of centrifugal pump set by dismantling completely and replacing unserviceable ball bearing, shaft sleeve, gland neck ring gland rope, nut and bolts, impellers etc. assembling back the complete pump and fixing alignment to the original position and coupling with pump and necessary alignment etc with Two coat enameled paint including scraping complete and written MES/SM, testing and commissioning complete all as specified and directed Note: (i) Spares shall be included in the quoted unit rate.
(ii) Painting and writing shall be included in the quoted unit rate.
(a) Maintenance schedule :- (i) Checking for looseness of all the foundation and coupling nuts/bolts and rectification.
(ii) Checking of leakage in gland packing, shifting base, bushes sluice valves, gate valves etc and rectification.
(iii) Checking for any undue noise of motor pump and rectification.
(iv) Checking for proper alignment and rectification.
(v) Checking for proper lubrication in bearing and lubricating.
(vi) Checking all electrical panel using for pumping for cleanliness and rectification for any looseness burnt redressing etc.
-
-
-
... More
(a) 5 HP
6
-
-
... More
(b) 7.5 HP
6
-
-
... More
Monthly testing of water samples as per parameters given below in order to diagnose the water quality for AC Chilled line and Condensed water system complete all as specified and directed.
(a) Ph Value
(b) Total Hardness
(c) Chlorine
(d) Stability Index
(e) Floating carbonic Acid
12
-
-
... More
Material and labour for checking Indoor/Outdoor unit, cleaning coil, lubricate fan motors, checking and cleaning drain connection and servicing of 1.5/ 2.0/ 3.0 Ton capacity Hiwall/ cassette/ split type ACs complete up to satisfaction and as specified and directed by Engr-in-Charge.
28
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%