Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Oct 2024
Closing Date18 Nov 2024
Tender Amount₹ 46,00,000
Costs
EMD
₹ 92,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680466_1Bid Award Id
ViewTender No
8438/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, spreading and compacting of riddled earth in trenches for cable cushion on both top and bottom of cable, including ramming complete all as specified and as directed by Engr-in Charge
134.55
-
-
... More
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed.
12717.4
-
-
... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories incl taking down old cable complete all as specified & as directed. Make : HAVELLS/GLOSTER/POLYCAB. Note :- Necessary earthwotk, PCC etc shall be measured & Paid separately under relevant items of works
800
-
-
... More
Description all as per Item Sl No 6 here in above but of size 95 Sqmm 3.5 core.
650
-
-
... More
Description all as per Item Sl No 6 here in above but of size 50 Sqmm 3.5 core.
300
-
-
... More
Description all as per Item Sl No 6 here in above but of size 185 Sqmm 3.5 core.
200
-
-
... More
M&L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
65
-
-
... More
Description all as per Item Sl No 6 here in above but of size 50 mm dia .
40
-
-
... More
M&L for straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 25 to 50 Sqmm 4/3.5 core incl earthwork, taking down, preparation of damaged cable incl testing complete all as specified & as directed by the Engr-In-Charge. Make : DENSON/3M/YAMUNA/RAYCHEM.
4
-
-
... More
Description all as per Item Sl No 12 here in above but suitable for Aluminium conductor cable of size 70 to 150 Sqmm 3.5 core.
4
-
-
... More
Description all as per Item Sl No 12 here in above but suitable for Aluminium conductor cable of size 185 to 300 Sqmm 3.5 core.
4
-
-
... More
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm upto 7.5 Mtr by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion Note:- On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.complete.
8
-
-
... More
M&L for cutting the existing hardstanding/PCC/WBM road at a depth of not less than 60 cm & 30 cm in width for passing of UG cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
27
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) & incl the following accessories complete all as specified & as directed. (a) Tinned Copper Bus-bars 04 Nos of rating 600 A, duly insulated with 1100 V grade standard colour coded PVC sleeves
(b) Digital type Multi-Function meter with built in selector Switch with CTs of -/5A, (c) R,Y,B LED Indicator lamp - 01 Set. (d) Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size -02 Nos
INCOMING: (a) 4 Pole MCCB 250 to 320 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-01 No (b) open Execution Motorised Onload changeover switch -01 Nos, open-execution modular construction type , confirming to IS/IEC 60947, -3 rated current -250 Amps 415 volts , 4 pole, AC 23 A -01
OUTGOINGS: (a) Supply and fix 4 Pole MCCB 100 Amp,50 Hz, 415 V with rupturning capacity 10 KA-04 Nos (3W+1S) (b) Supply and fix time switches s 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. (c) MCB TPN 63A.-2 Nos (d) Suitable for 15 HP Pump set Star delta stater - 03 (02 W+01S)
1
-
-
... More
Supply, install, testing & commissioning of Main LT control panel board "out-door type" of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & High grade aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) & incl the following accessories complete all as specified & as directed.
(a) Tinned Copper Bus-bars 04 Nos of rating 600 A, duly insulated with 1100 V grade standard colour coded PVC sleeve
(b) Digital type Multi-Function meter with built in selector Switch with CTs of -/5A
(c) R,Y,B LED Indicator lamp - 01 Set.
(d) Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size -02 Nos
INCOMING:
(a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-01 No
OUTGOINGS:
(a) Supply and fix 4 Pole MCCB 160 Amp,50 Hz, 415 V with rupturning capacity 10 KA-01 Nos (b) Supply and fix 4 Pole MCCB 100 Amp,50 Hz, 415 V with rupturning capacity 10 KA-04 Nos (3W+1S)
(c) Supply and fix time switches s 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure
(d) MCB TPN 63A.-2 Nos
1
-
-
... More
S&F Enclosed Automatic Transfer switch, Frame 3, 4P, 250A , AC-31A Out door type complete accessary & including fixing arrangment and necessary connection complete all as specified and dircted by Engr-in-Charge. Make : L&T Cat No : CK90164BSOO or techno-commercially equivalent in Legarnd /ABB/ Siemens.
2
-
-
... More
S&F of Laod Testing of DG 100 KVA for 12 hours at different loads test up to 110% comprising of the following :-
(a) Heating Coil
(b) Flexible Cable
(c) GI strip 32 X 6 MM
(d) 1.1 KV XLPE UG 3.5 C X 150 Sqmm Cable (Appx 20 RM) (e) Disel as per requried
2
-
-
... More
Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in watering and removing surplus soil to a distance n exe 50m and making good surface in soft /loose soil all as specified and directed.
20
-
-
... More
M&L for Cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in foundations,filling and mass concrete
4.25
-
-
... More
M&L for steel work in tubular post, trusses including special shaped washer etc..complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade E-250 all as specified.
4200
-
-
... More
S&F prepainted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strenth of 550MPA as in roof covering /cladding to wall,crimp curved where necessary fixed with self tapping screws complete all as spd and directed
280
-
-
... More
S&F Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet
0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws as specified.
35
-
-
... More
Material and labour for two coat SE paint on steel surface over one coat of red oxide primer incl prepareation of new or old steel surface complte all as spd and directed.
150
-
-
... More
S&F PVC(SWR) 150mm dia half round Rain water gutter incl all joints etc complete all as directed by the Engr In Charge
30
-
-
... More
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches complete all as specified and as directed.
35
-
-
... More
Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in soft /loose soil etc complete.
160
-
-
... More
Roughening surfaces of old concrete floor by picking, sweeping clean and
washing down with water to remove dust etc complete.dust, etcwashing down with water to remove dust, etc
110
-
-
... More
M&L for Hard core, broken to gauge n exc 63 mm with broken stone /boulders all as directed by the Engr In charge.
12
-
-
... More
M& L for 75mm thick PCC type C-2(1:3:6) using 40mm graded stone aggregate as in pavings,hard standing etc including finishthe surface even and rough to receive the top finish complete all as diercted by the Engr In charge.
270
-
-
... More
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
8
-
-
... More
M&L for Machine pressed precast concrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specifed and directetd.
160
-
-
... More
S & F 15mm thick plain Endura parking tile of size 300 x 300mm of any colour in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement, laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
110
-
-
... More
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggragate steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as directed
3.65
-
-