Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date23 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 28,50,000
Costs
EMD
₹ 57,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676062_1Bid Award Id
ViewTender No
8149/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in repairs Bib taps 15mm bore cast copper alloy with crutch or butter fly handle chromium plated screwed down for iron pipe or for brass ferrule.
10
-
-
S&F in repair stop valves15 mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
43
-
-
S&F Pillar taps 15mm, cast copper alloy with capstan heads, CP fancy type, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe.
8
-
-
M&L for toilet paper holder with flat recessed type stainless steel complete all as specified.
10
-
-
S&F Vitreous China wash basin oval shaped, white, size 550 x 400mm embedded on marble platforms including cutting for and pinning in ends of brackets or erecting stand brackets, 32 mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms & waste pipe including taking down of old wash basin complete.
8
-
-
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 600mm.
33
-
-
S&F in repairs 450 x 600 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers
8
-
-
S & F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 30cm long between flanges
2
-
-
Supply and fix in repairs Vitreous China Urinal, Half stall type coloured complete fixing with suitable fixing arrangements to wall with and including CP urinal spreader, CP domed waste coupling and waste pipe complete, all as directed.
15
-
-
Demolition and breaking up drain pipes any type set in cement mortar
184
-
-
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor , 75mm bore.
40
-
-
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 75mm bore.
72
-
-
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floors, 110 mm bore.
24
-
-
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 110 mm bore.
48
-
-
S&F PVC (SWR) bend 110 mm bore.
24
-
-
S&F PVC (SWR) floor trap with grating including jointing to solvent cement waste pipe 75 mm dia.
20
-
-
S&F PVC (SWR) Gully trap 125 / 110mm setting and jointing with solvent cement.
8
-
-
S&F PVC (SWR) vent cowl 110 mm
6
-
-
S&F PVC (SWR) junction single, (Single T) equal or unequal for 110 mm bore pipe with access door
6
-
-
S&F PVC (SWR) junction single, (Single T) equal or unequal for 75 mm bore pipe with access door
6
-
-
S&F PVC (SWR) bend 75 mm bore.
24
-
-
Grating doom 100mm dia of PTMT Minimum weight 25gms)
10
-
-
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof Bore of pipe 110 mm
36
-
-
S & F in repairs rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified including taking down old tanks
3
-
-
S & F Ball valves 25 mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms)
3
-
-
S&F in repairs 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
3
-
-
S&F in repairs 50mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
2
-
-
Taking up or taking down steel/iron tube of 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified.
56
-
-
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified.
56
-
-
Taking up or taking down steel/iron tube of 25 mm bore and connections including cleaning for refixing or removal to store complete all as specified.
90
-
-
Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified.
90
-
-
Taking up or taking down steel/iron tube of 50 mm bore and connections including cleaning for refixing or removal to store complete all as specified.
20
-
-
Supplying and laying of 50 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified.
20
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness below or above ground level.
17.6
-
-
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
0.6
-
-
Demolition of brick work built in cement mortar including all precast concrete articles.
9
-
-
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises.
157
-
-
M & L for providing 25 mm thick Cement concrete type B-1,1:2:4 using 20mm graded stone aggregate as in floor furnishing.
252
-
-
M & L Non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including cement screed 15 mm thick in CM 1:4 all as directed
80
-
-
M & L Non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including cement screed 15 mm thick in CM 1:4 all as directed
172
-
-
Material and labour for glazed ceramic coloured tiles, 350X250x7 or 450 x 350 mm x7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement plaster 10mm thick in CM 1:3 all as specified
228
-
-
M & L for brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4
60
-
-
M & L for providing lintels upto 1.5m clear span on half brick partition wall with cement concrete Type B1, 1:2:4 using 20mm graded stone aggregate including use of form work.
0.68
-
-
M & L for providing cement concrete type B1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, deck slabs and in shelves complete
1.2
-
-
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, shelvings and similar work not exc 200mm thick for fair finished flat surfaces. all as specified.
12
-
-
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed in CM 1:4
12
-
-
M&L for TMT steel bars 10mm dia and over, cut to length bent to shape required as in reinforce ment to lintels all as specified and as directed
180
-
-
All as per item No. 50.00 above but 6mm to 8mm dia
72
-
-
All as per item No. 50.00 above but 5mm dia and over upto and including 10mm dia in stirrups.
90
-
-
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc. 1.5 Sqm but n. exc 4 Sqm each including making good disturbed surfaces
19
-
-
All as per item No. 53.00 above but n exc 1.5 Sqm each.
33
-
-
S&F Solid PVC door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying &fixing in opening as per specification &drawing Note:- (i) Existing wall edges will have to be finished properly in cement plaster 1:4 . including fixing of 6 Nos wooden plugs for catch door frame size not exc 17Sqcm average sectional areas and 100mm long. (ii) Frame will have to be fixed to the wooden plugs inserted in wall using 6 Nos of 100mm long MS screw, 3 each on either side. (iii) PCC strip of section 5*5mm will have to be created at bottom incl. smooth finish in each door opening.
50
-
-
S&F Factory Made Solid Panel PVC Door shutter 30mm thick (Style) consisting of frame made out of M S tubes for top & bottom rails, M S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail and jointed together with solvent cement, supplying & fixing in frame at site as per specification & drawing
15.75
-
-
S&F Anodised aluminium (minimum 50 micron) frame for doors, windows, ventilators, Partitions and grills/guard bars etc with one or more rebates including joining cleat for fixing etc. complete all as specified.
225
-
-
S & F anodised aluminium window and ventilator shutters, side hung type (minimum 50 micron) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 No), suitable handle (1 No), etc. complete all as specified
22
-
-
Anodised aluminium window and ventilator shutters, fixed type
(min 50 micron) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified & directed
5.6
-
-
S & F Anodised aluminium deco grill of size of mesh not exc 75mm x 75mm, thickness shall approx be 6mm, decorative type and fixed with suitable aluminium section fixed to alum frame of windows / ventilators complete all as specified and as directed.
25
-
-
S&F 4.0mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and fixed to aluminium frames using rubber packing
6
-
-
S&F Butt hinges 100 mm, mild steel hinges fixed with stainless steel screw with frame
57
-
-
S&F Aluminium anodised barrel tower bolts of extruded section 150 mm size
38
-
-
S&F Extruded aluminium alloy handles, fabricated type, anodised 125 mm long
38
-
-
M & L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 all as specified
2.4
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc
120
-
-
M&L for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement on internal wall surfaces.
60
-
-
M & L for Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete as specified.
48
-
-
M&L for 35mm thick II nod class HW factory made plain framed panelled door shutter two panels, with lock rail and panel of 9mm BWP, commercial ply or 12mm veneered particle board with commercial face veneering on both faces
20
-
-
Cutting holes in brick walls exc half brick n.exc one brick, built in cement mortar for inserting hold fast and making good dismantled portion in cement concrete 1:2:4 type B-1 as required
120
-
-
S & F mild steel FI 25 x 3mm holdfast 300mm long, hand made sliding bolts, clamps, hook and pintle hinges, large hasp and staples similar articles conforming to Fe 290 gde E 165
22
-
-
S&F 4.0mm thick Sheet glass, ordinary quality and glazing
with oil putty in square n exc 0.5 sq. m in each pane and fixed to aluminium frames using rubber packing complete.
20
-
-
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed.
9
-
-
M & L for preparing new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of Synthetic enamel paint over a coat of pink primer , complete all as specified and directed.
48
-
-
M & L for cement concrete type B0 1;2:4, using 12.5mm graded stone aggregate as in back filling to pressed steel frames complete all as specified and as directed.
0.3
-
-
M & L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surface even and smooth including taking down existing cement plaster if necessary.
60
-
-
Supply only integral water proofing chemical compound.
3.5
-
-
Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer over a coat of wall care putty to internal wall surfaces complete all as specified and as directed.
304
-
-
Preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer all as specified and as directed.
60
-
-
Preparation of old decorated ceiling surfaces including necessary scaffolding and applying one coat of white wash including filling the cracks/depressions using chalk whitening wherever required all as specified
260
-
-
Complete removal of existing treatment on walls and applying two coats of exterior weather proof paint over a coat of weather proof primer to all external wall surfaces complete all as specified and as directed.
364
-
-
M & L for 75mm thick plain cement concrete type C1, 1:3:6 as in plinth protection and finishing the surface even and smooth
90
-
-
Removing the existing roof treatment of any description completely and removal of all the debris from site and rubbish off the premises complete all as directed.
355
-
-
M&L for cement Screed bed 20mm thick in CM 1:4 with using waterproofing liquid as per manufacturers instructions.
(WPC Measured and paid separately)
355
-
-
M & L for water proofing treatment with APP modified prefabricated five layer water proofing membrane, not less than 3mm thick and weighing not less than 3.00 Kg/Sqm reinforced with non woven polyester matt black finished over compatible primer at 0.3 litre/Sqm, touching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions . The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage.
Note : The work shall be carried out be authorised applicators of manufactures
355
-
-
Taking down carefully copper/ Aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit all as directed.
104
-
-
Material and Labour for Point wiring complete with 1.5 sqmm FRLS single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth all as specified and as directed.
-
-
-
(a) One light point controlled by one switch.
48
-
-
(b) One Ceiling fan point controlled by one switch and one regulator.
7
-
-
(c) One 3 pin 5 amps switch socket on independent board.
22
-
-
(d) One 3 pin 5 amps switch socket on same board along with other switches.
8
-
-
(e) One exhaust point controlled by one switch
7
-
-
All as per item No.87 above but with 4 sqmm FRLS copper conductor cable with 2.5 sqmm PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch 15/16 Amps on independent board all as specified and as directed.
12
-
-
M&L for sub main wiring with PVC insulated, 1100 volts grade single core FRLS multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of 6 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed.
60
-
-
Supply and fix Wall mounted LED 20W batten basic all purpose surface and wall mounted LED batten with Aluminium housing & Integrated electronic driver all as specified and as directed.
30
-
-
Supply and fixing wall mounted LED 10W batten, Extruded aluminium housing provided efficient heat dissipation with polycarbonate diffuser with integrated electronic driver high efficacy. short circuit & voltage cut off protection, wide operating voltage range of 140V to 270V wide, lumen output of 1050, including lamp with complete all as specified and as directed.
4
-
-
Supply and Fix Endura PEARL 30 W MP Bldg Sec lights New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP 66 roadway luminaries with high power LEDs as light source and electronic driver of Lamp type:30W LED 6000K along with Suitable bracket complete all as specified and as directed.
6
-
-
Supply and replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 240 Volts 20 Amps all as specified and as directed.
5
-
-
Supply and fix MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory including taking down Old DBs all as specified and directed.
1
-
-
Supply and fix MCCB four pole , 415 Volt, 100 Amps,16 KA , adjustable thermal & fixed magnetic setting including taking down Old MCCB complete all as specified and directed.
1
-
-
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link,04 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
1
-
-
Supply & Fix MCB SPN 230 volts, 40 amps 'C' Curve 10 kA Capacity including taking down Old MCB complete all as directed.
1
-
-
Supply & Fix MCB SP 230 volts,40 amps 'C' Curve 10 kA Capacity including taking down Old MCB complete all as directed.
14
-
-
S & F Ceiling rose surface bakelite 65mm x 50 mm two to three terminals all as directed.
54
-
-
S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed
92
-
-
S & F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed
12
-
-
S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
30
-
-
S & F Modular socket 6 A/ 16 A - 2/3 pin combined 2 module complete all as specified and directed
12
-
-
S & F lamp holder, insulated body, with back plate for batten fitting with LED bulb complete all as specified and as directed.
8
-
-
S & F Modular Fan step regulator, 100W - 1 module for ceiling Fan of 1200 mm sweep all as specified and as directed.
7
-
-
Taking down Ceiling/ Exhaust fan, sealing cable end, dismantling blades and removing fan and blades to and depositing it to MES store yard without any damage. It included the charges of transpiration of fan and labour cost etc. Note:- Old Unserviceable Fan to deposited to MES Store
14
-
-
Supply & Fix in replacement of 1200 mm sweep ceiling fan BLDC rating, energy saving model with double ball bearing 230 volts 3 blades white in colour without regulator COMPLETE WITH CANOPY, suitable DOWN ROD all as directed.
7
-
-
Supply and fix in replacement of ventilating fan of size 250 mm sweep white in colour, plastic body all as specified and as directed.
3
-
-
Supply and exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers includuing all accessories as per site requirement complete all as specified and as directed.
4
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
24
-
-
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
12
-
-
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as directed.
12
-
-
Supplying and laying burnt brick "B" class standard size for protection of cable as directed.
1035
-
-
Fine Sieved excavated dry Soil laid to the required width of trench at bottom and top of cable as cushioning all as specified and as directed.
10
-
-
Supply & Lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes all as specified and as directed.
Note:- (i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board.
(ii) Earth work such excavation, refilling, etc. shall be measured separately under relevant items.
-
-
-
(a ) 2 core 16 Sqmm
80
-
-
(b ) 3.5 core 35 Sqmm
90
-
-
M&L for of tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed
18
-
-
Material and Labour for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth wire 4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 5 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements