Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2023
Closing Date11 Jan 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633139_1Bid Award Id
ViewTender No
8386/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : (Secrigation ward)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 600 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 320 to 400 - 01 Nos. Make : L & T, Cat No : CM98403OOROOG or techno-commercially equivalent of Legrand /Siemens
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 Amps - 02 Nos. for Karnatic Line
Make : L & T, Cat No : CM90642OONO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 A to 100 A - 02 (1W+1S) Nos. for Gym Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemen
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : (BSO Furniture Yard )
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 600 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 320 to 400 A - 01 Nos. Make : L & T, Cat No : CM98403OOROOG or techno-commercially equivalent of Legrand /Siemens. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 400 Amps, 415 Volts, 4 Pole, AC 23A - 01 No. Make : L&T, Cat No : CO44000OOOO or techno-commercially equivalent in ABB/ Siemens.
1
-
-
OUTGOINGS : (a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 01 Nos
Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens.
(b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 A - 03 Nos.(2W+1S)
Make : L & T, Cat No : CM9171200JOOG or techno-commercially equivalent of Legrand /Siemens.
(c) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemens.
(d) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 01 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : (Golf Power House )
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 600 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 320 A - 01 Nos. Make : L & T, Cat No : CM98403OOROOG or techno-commercially equivalent of Legrand /Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 Amps - 03 (02 W+1S) Nos. Make : L & T, Cat No :CM90642OONO or techno-commercially equivalent of Legrand /Siemens. .
(b) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemens. (c) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 01 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : ( WH 17 Block)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 400 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 250 - 01 Nos. Make : L & T, Cat No :CM92109OOP1OG or techno-commercially equivalent of Legrand /Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 A - 02 Nos (1W+1S). Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens.
(b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80A to 100 A - 03 Nos (2W+1S). Make : L & T, Cat No : CM91712OOKOOG or techno-commercially equivalent of Legrand /Siemens. (c) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemens. (d) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 01 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : (Singara thoppu Panel)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 600 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
IINCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 320 to 400 A - 01 Nos. Make : L & T, Cat No : CM98403OOROOG or techno-commercially equivalent of Legrand /Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 A - 02 Nos (1W+1S) Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 A - 02 Nos
Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (d) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemens (e) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 01 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but of size 1200 (height) x 1000 (breadth) x 600 (depth) mm (minimum dimensions) with & including the following accessories : (GH 41 A Panel)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 250 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 160 A - 01 Nos. Make : L & T, Cat No : CM92108OOM1OG or techno-commercially equivalent of Legrand /Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 Amps - 03 Nos (2W+1S). Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (b) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 01 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but of size 1200 (height) x 1000 (breadth) x 600 (depth) mm (minimum dimensions) with & including the following accessories : ( Cedar Panel)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 250 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 A - 01 Nos . Make : L & T, Cat No : CM90642OOMO or techno-commercially equivalent of Legrand /Siemens. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 160 Amps, 415 Volts, 4 Pole, AC 23A - 01 No. Make : L & T, Cat No : CO21600OOOD or techno-commercially equivalent in ABB/ Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 Amps - 03 Nos (2 W+1S)
Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (b) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemen
(c) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 02 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens.
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
All as per item No 1.00 here in before but with & including the following accessories : (VVIP Guest House)
(i) BUS-BAR & INTERNAL CONNECTIONS :
The bus-bars shall be made up of 04 Nos high grade Aluminium 250 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY :
The provision for cable entry /exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 160 Amps - 01 Nos. Make : L & T, Cat No : CM90642OOMOor techno-commercially equivalent of Legrand /Siemens. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 160 Amps, 415 Volts, 4 Pole, AC 23A - 01 No. Make : L & T, CO21600OOOO or techno-commercially equivalent in ABB/ Siemens.
1
-
-
OUTGOINGS :
(a) MCCB 4 Pole (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 Amps - 04 Nos (3W+1S)
Make : L & T, Cat No : CM91712OOJOOG or techno-commercially equivalent of Legrand /Siemens. (b) MCB TPN "C" series having breaking capacity 10 KA of rating 63 Amps - 02 No. Make : L&T CAT No AU10S40633C /Legrand /Siemens. (c) MCB SPN "C" series having breaking capacity 10 KA of rating 32 Amps - 01 No. Make : L&T CAT No AU10S20323C /Legrand /Siemens. (d) Time switch 415 Volts, 3 Phase of 20 Amps rating with Contactor complete . Make : L&T, Cat No (AUTS02DIG00- timer, CS94190-contactor) or techno-commercially eqvt of Legrand /Siemens
-
-
-
INSTRUMENTATION SYSTEM :
(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : L & T, Cat No: WL411010OOOO or techno-commercially equivalent of Elmeasure /Secure.
(b) Indicator lamp with integral circuit (230/240 Volts) & cluster LED (Red, Orange, Blue) - 01 Set.
(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).
(d) Door opening key - 02 Nos
-
-
-
Supply, install, testing & commissioning of LT busbar junction box "out-door type" of size 750 mm (height) x 600 mm (breadth) x 300 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The box shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade aluminum bus-bar of rating 400A of length 600mm, min spacing of 80mm between the busbars & wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming cable rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including I/C & O/G cable opening on bottom & at both sides including cable glands of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl MCCB 200 Amps - 01 Nos and incl taking down old unsv box , MCCB of any size/type complete all as specified & as directed. Notes for Item Nos 1.00 to 10.00 :-
(i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer.
(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
6
-
-
M&L Repairs to feeder pillar box/LT panel etc, taking out old unserviceable and fixing of new hinges (if any) by welding/bolt nuts,addn/altn to MCCB enclosure cover with one incoming and No of out goings by grinding,cutting and painting all as shown and diretced, repairs to door lock by replacing unsv locks, extension of aluminium bus bars for incoming/outgoing MCCBs as per existing shapes and size, spray painting with two coats of approved grade & color synthetic enamel paint after scrapping incl preparation of old painted surfaces & fixing 02 nos (front & back) danger notice plate as per standard size complete all as specified and directed.
4
-
-
Labour only for taking down the existing solar battery from solar system and making the electrical connection to exsiting one and taking the credit of solar battery in to store yard / Sch of credit complete all as specified and directed.
54
-
-
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for taking out/laying of UG Cables, GI Pipe etc. and getting out in hard dense soil complete all as specified and directed.
918
-
-
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
391
-
-
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
527
-
-
M&L Providing sand cushioning for protection of UG cable in trenches with dry (coarse) river sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and directed. Note:Only punned thickness will be measured and paid.
275
-
-
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified and directed.
29050
-
-
Supply and laying GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH.
60
-
-
Description all as per Item Sl No 18.00 here in above but of bore 80 mm. Make : TATA/JINDAL/PRAKASH.
60
-
-
Supply and laying GI pipe light grade with all running fittings (ISI Marked), laid under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH.
60
-
-
Description all as per Item Sl No 20.00 here in above but of bore 50 mm. Make : TATA/JINDAL/PRAKASH.
80
-
-
Notes for Sl Item No 17.00,18.00,19.00 & 20.00 : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
-
-
-
M&L Cutting the existing hardstanding/PCC/WBM road at a depth of not less than 60 cm & 30 cm in width for passing of HT/LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
100
-
-
Notes for Item Nos 13.00,17.00,18.00, 19.00, 20.00 & 23.00: Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the excavation/boring/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.
-
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed. Make : HAVELLS/GLOSTER/POLYCAB. Note :- Necessary earthwork, PCC etc shall be measured & Paid separately under relevant items of works
200
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
200
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
330
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
680
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
210
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
175
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
250
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
975
-
-
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with Lugs & connecting accessories incl taking down old cable complete all as specified & as directed.
210
-
-
M&L Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Notes :-1) On completion of the complete work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. 2) If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
4
-
-
S&F MCCB, 4 pole,200A rating (Ics = 100% Icu),415Volts,36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F MCCB, 4 pole,400A rating (Ics = 100% Icu),415Volts,36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
2
-
-
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed. Make: Cat No : CO22000OSOO of make L&T or equivalent of ABB/SIEMENS.
2
-
-
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 250 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed . Make:Cat No : CO32500OOOO of make L&T or equivalent of ABB/SIEMENS.
1
-
-
M&L Shifting of DG/LT Panel/Transformer from sub stn No 2 to Golf Pump House any type/capacity/size using Hydra/Crane/JCB etc. by disconnecting the electrical connections from existing location & making electrical connections incl commissioning of the DG /LT Panel/Transformer at new/changed location & making good the disturbed/damaged surfaces etc. complete all as specified and directed.
1
-
-
S&F Danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts complete all as specified and as directed.
12
-
-
M&L Cutting grass, bushes, creapers, weeds, unwanted plants/growths, area cleaning etc in and arround Electric Supply Installations, LT Panels, Feeder Pillar Boxes or any other locations as decided by Engr-In-Charge/GE and removing rubbish off the premises complete all as specified and as directed. NOTE : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.
1200
-
-
M&L Preparation of old painted steel surfaces of outdoor/indoor type LT/HT Panels, Feeder Pillar/Junction boxes, Change-over Boxes etc. of any size/type etc. after cleaning of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. complete & applying one coat of synthetic enamel paint of approved colour & grade using spray gun & neatly writing distribution details (if applicable) and repair /replacement Hinges, and complete all as specified and as directed.
50
-
-
M&L Preparation of old painted steel surfaces of LT/HT/Security/Street light steel tubular poles and structure incl MS Clamps, cross arms, GI Pipe brackets etc. of any size/type etc. after cleaning/removal of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. & applying one coat of Aluminium paint & neatly writing pole numbers incl trimming of tree branches near pole complete all as specified and as directed.
25
-
-
S&F Straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 25 to 50 Sqmm 4/3.5 core incl earthwork, taking down and preparation of damaged cable incl testing ccomplete all as specified and as directed. Make : DENSON/3M/YAMUNA/RAYCHEM.
10
-
-
Description all as per Item Sl No 44.00 here in above but suitable for Aluminium conductor cable of size 70 to 150 Sqmm 3.5 core.
10
-
-
Description all as per Item Sl No 44.00 here in above but suitable for Aluminium conductor cable of size 185 to 300 Sqmm 3.5 core.
2
-
-
S&F in repairs Aluminium cable lugs after removing the old /burnt out cable lugs of cable from MCCBs/Changeover/Transformer LT bushing and connecting back cables in MCCBs/Changeover/Transformer LT bushing for 16 sqmm to 25 sq mm complete all as specified and as directed.
10
-
-
Description all as per Item Sl No 47.00 here in above but 35 Sqmm to 50 Sqmm complete all as specified and as directed.
10
-
-
Description all as per Item Sl No 47.00 here in above but 70 Sqmm to 95 Sqmm complete all as specified and as directed.
10
-
-
Description all as per Item Sl No 47.00 here in above but 120 Sqmm to 185 Sqmm complete all as specified and as directed.
10
-
-
S&F 4 pole Power Contactors MCX 31/32 AC-1 aux contacts (2 No + 2 NC) Rating Fr 4 setting and making cut in existing panel complete all as specified and as directed. Make: L&T (Cat No CS97020)/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F MCCB , 4 pole, 63A rating (Ics = 100% Icu), 415Volts, 25 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F MCCB, 4 pole,100A rating (Ics = 100% Icu),415Volts, 36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and c complete all as specified and directed. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F MCCB, 4 pole,160A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity, with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and as directed .Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F MCCB, 4 pole,250A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity, with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and as directed. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
1
-
-
S&F SPN DB 02 Way IP 43 sheet metal enclosures DBs and making good the disturbed surfaces will all other acessories including all connecting items all as specified and directed. Make : L& T/Havells/Legrand
10
-
-
S&F MCB SPN C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KAS all specified and directed by Engr-in-Charge. Make : L& T/Havells/Legrand
10
-
-