Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date22 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 33,00,000
Costs
EMD
₹ 66,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667661_2Tender No
8909/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVISION OF TOILET BLOCK FOR LADIES AND GENTS NEAR CADET MESS BLDG NO T 26 AND GUARD REST ROOM ALONGWITH TOILET FOR WARD BOYS FOR JUNIOR HOSTEL BLDG NO P 25 FIRST FLOOR OPEN TERRACE AT SAINIK SCHOOL AMARAVATHI NAGAR UNDER GE WELLINGTON
BOQ Items
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under-reamed piles and mass concrete all as specified and directed.
9.5
-
-
Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed.
43
-
-
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate for columns, etc, complete all as specified and as directed.
8.7
-
-
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
78
-
-
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate for Beams, cantilevers, bressumers, lintels over 1.5m span, complete all as specified and directed.
10.8
-
-
Use and waste of steel Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surfaces of concrete flat complete all as speicified and directed.
68.5
-
-
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate for Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres etc compelte all as specified and directed
1.9
-
-
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges,etc compelte all as specified and directed.
8.35
-
-
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like compelte all as specified and directed
21
-
-
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick column, beam etc (Horizontal or sloping) rough finished all as specified and directed.
130
-
-
Use and waste of form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roof not exceeding 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide all as specified and directed.
64.5
-
-
Mild steel TMT bars grade Fe 500D, 10mm dia and over, cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
5145
-
-
All as per item No 15 hereinbefore but 6 to 8mm dia as in stirrups all as specified and directed.
850
-
-
Mild steel TMT bars grade Fe 500D, 5mm dia and over upto and incl 10mm dia in stirrups, spacers, and binders in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire all as specified and directed.
2310
-
-
Rendering 10mm thick cement plaster in cement mortar 1:4 on top of roof slab with water proofing compound all as specified and directed.
150
-
-
Supply only liquid water proofing compound for water proof plastering complete all as specified and directed.
3.06
-
-
Applying eenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including cleaning the surface and APP based polymeric membrane weighing minimum 3Kg/sqm and minimum 300 thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and as directed.
168
-
-
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exceeding 15 cm but not exceeding 30 cm in width or girth; including cutting to edges, all mi- tres and stopped ends, etc all as specified and directed
33
-
-
Plain cement concrete Type B1 Using 25mm graded aggregate as in coving/ coping/ haunching complete all as specified and as directed
0.57
-
-
Moorum / Red bajri filling in floors or pavings laid in layers not exceeding 15cm, spread, levelled and rammed including watering all as specified and directed.
11.45
-
-
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
11.45
-
-
100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of flooring / hard standing and finished even and fair complete all as specified and directed.
70
-
-
25mm thick PCC(1:2:4) type B1 using 20mm graded stone aggregate as in flooring finished even and smooth using extra cement.
70
-
-
75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection / path, laid and finished in bays not exceeding 3m c/c and filling the joints with mastic bitumen complete all as specified and directed.
33
-
-
Pre-cast cement concrete block masonary Type CI 1:3:6 using 20 mm grade stone aggregates with solid blocks, exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
41.5
-
-
Precast cement concrete solid block masonary with solid blocks using PCC 1:3:6 type C1 using 20mm graded stone aggregate n.exc 10cm in width and setting in cement mortar 1:4 etc complete all as specified and directed.
58
-
-
Rendering 15mm thick on fair faces of brick / concrete / RR masonry surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
235
-
-
External rendering 5mm thick in cement mortar 1:4 with liquid water proofing compound over a coat of 10mm thick in cement mortar 1:6 over brick or concrete surfaces finished even and fair all as specified and as directed.
Note: W.P.C shall be measured and paid separately.
215
-
-
Rendering to ceiling in 10mm thick on fair faces concrete surface in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
110
-
-
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
26
-
-
Coloured Glazed ceramic tiles in vertical surfaces 450mm x 350 x 7mm / 350mm x 250mm x 7mm to 8mm thick as in dados, skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigments to match the surface, on including 10mm thick rendering in cement mortar 1:4 for fixing dado tiles complete all as specified and directed.
140
-
-
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified and directed.
62
-
-
Factory made solid panel PVC door shutter 30mm (Stile) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed.
23
-
-
Anodised aluminium frame powder coated for doors, windows ventilators, U channels safety grill with one or more rebates including joining cleat for fixing complete all as specified and directed.
109
-
-
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminiu snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
11.4
-
-
Mild steel framed work such grill/ guard bars including fixing on steel window/ ventilator frames complete all as specified and as directed.
150
-
-
ground or obscured or frosted sheet glass 3 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane all as specified and directed.
30
-
-
Stainless steel wire cloth fixed in repairs, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples in steel / wooden joinery etc all as specified and directed.
18.4
-
-
Butt hinges extruded Aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21, with MS hinge pin 100mm size all as specified and directed.
36
-
-
Aluminium anodized barrel tower bolt of extruded section 150mm length all as specified and directed.
24
-
-
Aluminum handles, fabricated type ,anodised extruded section 150 mm long all as specified and directed.
24
-
-
Vitreous china wash down water closet pan (pedestal pattern) white with P or S trap including 32mm dia flushing pipe , seat and PVC seat cover (white) closed pattern with flat bottom & cover brass chromium plated hinging device, including connection to drain and to flushing pipe, antisyhonage pipe etc including fixed in repairs complete all as specified and directed.
6
-
-
PVC low level flushing cistern 10 litres capacity, valveless, syphonic action type, white, with inlet ball valve, float and handle including connecting to bracket complete all as specified and directed.
6
-
-
Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
6
-
-
Vitreous China urinal, half stall type complete including waste pipe, flush pipe and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc, and including connection to flushing pipe and outgoing pipes fixed in repairs complete all as specified and as directed.
3
-
-
Vitreous china wash basin, white flat back size 550 X 400 mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of taps, fixing of supply and waste pipe complete all as specified and directed.
6
-
-
PVC connections 15mm size with PTMT nuts of length 750mm all as specified and directed.
15
-
-
Bib taps, 15mm, fancy type, cast copper alloy with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule all as specified and as directed.
8
-
-
Pillar taps, 15mm, fancy type, cast copper alloy with capsten heads, chromium plated, screwed down high pressure, screwed for iron pipe and fixed all as specified and directed
6
-
-
Stop / angle valves, 15mm dia, fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
17
-
-
Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and as directed.
6
-
-
20mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
40
-
-
15mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
30
-
-
Rotational moulded polyethylene water storage tank, ISI marked three layer (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified and directed.
3
-
-
Ball valve high pressure 20mm dia of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, minimum weight 142 gms, complete all as specified and directed
3
-
-
20mm dia nipple of PTMT, suitable for HDPE water tank min weight 45 gms complete all as specified and directed.
4
-
-
600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and as directed
6
-
-
PVC (SWR) gully traps 125 x 110 mm, setting and jointing with solvent cement including concrete pedestal etc complete all as specified and as directed
4
-
-
110mm bore,PVC (SWR) Tee any radius, fitted with oval access door all as specified and directed.
12
-
-
110mm bore PVC (SWR) bends any radius all as specified and directed.
4
-
-
PVC (SWR) bends any radius, 110mm bore with oval access door complete all as specified and directed.
4
-
-
PVC (SWR) vent cowl of size 110mm bore dia complete all as specified and as directed
4
-
-
PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches or in floors, completed all as specified and directed.
11
-
-
75mm bore PVC (SWR) pipes single socketed, in any length, fixed to walls/ laid in floors all as specified and directed.
10
-
-
75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
4
-
-
Anti termite treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contac with backfill to be measured) all as specified and directed.
12
-
-
Anti Termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
20
-
-
Anti Termite treatment to soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
12
-
-
Anti Termite treatment to soil along with external perimeter of building at the rate of 2.25 litres of emulsion per square meter of perimeter wall complete all as specified and directed.
30
-
-
Applying three coats of white wash on ceiling surfaces including preparation complete all as specified and directed.
100
-
-
Applying two coats of oil bound distemper over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed.
160
-
-
Applying one coat of primer preparation of new plastered surface and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10Sqm over new surfaces complete all as specified and directed.
210
-
-
Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
39
-
-
Vitreous china urinal partition white of size 310x700 mm complete all as specified and directed
3
-
-
Brass chromium plated bottle trap 32 mm for wash basins with inlet and outlet screwd for pipe or connections including necessary packing, union and cap all as specified and directed.
4
-
-
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) all as specified and directed.
3
-
-
Removing excavated soil/ material to a distance exceeeding 250m and not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
25.25
-
-
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick using good quality of excavated soil complete all as specified and directed.
12.4
-
-
Gunmetal, globe or gate valves 20mm dia fixed (half turn type or wheel type), screwed both ends for iron pipe all as specified and directed.
2
-
-
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
3.35
-
-
Brick work with sub class ‘B’ bricks, burnt clay bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
1
-
-
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished fair and even and smooth with out using extra cement mixed with water proofing compound all as directed.Note: WPC shall be measured and paid separately all as specified and directed.
8
-
-
Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in cement mortar 1:4 complete all as specified and directed.
0.2
-
-
Cement concrete 1:3:6 type C-2 using 40mm grade stone aggregate bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 110mm bore PVC (SWR) drain pipes all as specified and directed.
5
-
-
Plain Cement Concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping including necessary form work all as specified and directed.
0.2
-
-
Precast RCC hume pipe septic tank for 25 users and of dia 1.20m, length 2.40m including transportation and fixing complete all as specified and directed.
Note: Earth work such as excavation, RFR etc shall be measured and paid separately.
1
-
-
900mm dia and 1.50m depth precast soakage well including fixing in position transportation complete all as specified and as directed
Note: Earth work such as excavation, RFR etc shall be measured and paid separately.
1
-
-
Demolition of Concret such as Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed
2
-
-
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
4
-
-
40mm thick PCC(1:2:4) type B1 using 20mm graded stone aggregate as in flooring finished even and smooth using extra cement all as specified and directed.
72
-
-
Dismantling, floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed.
29
-
-
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
25
-
-
All as per item No 95 here in before, but on vertical surfaces including 10mm thick in cement mortar 1:4 as in baking coat of dado/ skirting all as specified and as directed.
4
-
-
Plain Sheet glass 4.0mm thickness ordinary quality and glazing with oil putty in square but exceeding 0.5 sqm in each pane complete all as specified and directed.
28
-
-
Harrison rails of anodised aluminium alloy fixing with brackets, stops,rollers etc all as specified and as directed.
10
-
-
Point wiring complete with two runs of 1.5Sqmm (for Phase and Netural) PVC insulated unsheathed multistranded copper conductor FRLS cable of 1100V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit medium grade ISI, Marked with conduit accessories on wall / floor and fixed on ceiling / roof/ truss/ columns etc including provision of factory made branded galvanized steel pressed steel terminal box (modular metal flush box) 3mm thick of suitable module of housing the modular switches, sockets, fan regulators etc, complete on walls and provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc for one light point controlled by one modular switch complete all as specified and directed.
12
-
-
All as per item No 99 hereinbefore but one ceiling/ Exhaust fan point controlled by one modular switch all as specified and directed.
6
-
-
All as per item No 99 hereinbefore but one three pin moduler switch socket 5/6 amps outlet on independent board all as specified and directed.
4
-
-
Modular switch one way 6A 240V AC 50 HZ SP one module all as specified and directed.
22
-
-
Ceiling rose surface Bakelite three terminals complete all as specified and directed.
18
-
-
LED light fitting mirror type with high out put diffuser 2 feet, 1x 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specifie and directed.
4
-
-
LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed.
8
-
-
Exhaust Fan, Steel body heavy duty AC single phase 230V of size 300m sweep with blades, frame and louvers shutter, voltage 230V, 50Hz, copper winding, connecting up including provision of three core flexible copper wire of size 23/0.0076 all as specifie and directed.
4
-
-
Earthing complete with GI earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip of 32x6 mm by means of bolts and nuts washers mase out of GI and earth strip protected by Galvanized pipe light grade 40mm bore, 20 mm bore medium grade watering pipe and connected to main control board all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified.
2
-
-
Supply and fix in replacement of MCB DB, SPN 8 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
2
-
-
MCB SPN 40 Amps, 230 volts complete all as specified and directed.
3
-
-
Supply and fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP in the MCB DB complete with connection testing and commissioning all as specified and directed.
6
-
-
Well burnt bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and as directed.
0.22
-
-
supply and filling in and spreading of ribbed sand or riddled sand for cushioning and covering of the UG cables in trenches all as specified and directed.
2.03
-
-
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
30
-
-
Step type electronic fan regulator, modular, press type 2 module complete all as specified and directed.
2
-
-
Modular socket 2/3 pin combined 6A 240V AC 50 HZ SP two module all as specified and directed.
4
-
-
Ceiling fan complete with blades, down rods and accessories, 230V, 1400mm sweep min air delivery 245 CFM with service value 6.BEE, five star rated with brushless direct current motor (BLDC)connecting up including provn of three core flexible copper wire of size 23/0.0076 from ceiling rose to ceiling fan all as specifie and directed.
2
-
-
Sub main wiring with two runs of single core 6 Sqmm copper conductor FRLS cable PVC insulated unsheathed multistanded 1100V grade drawn through PVC casing and capping with all accessories, fixed to wall ceiling etc including 6 Sqmm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
85
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%