Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date21 Mar 2024
Closing Date17 Apr 2024
Tender Amount₹ 32,50,000
Costs
EMD
₹ 65,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_647443_1Bid Award Id
ViewTender No
8417/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling Wall and ceiling boards (fibre, pulp, insulation, prelaminated boards etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
305
-
-
Taking down chowkats or frames of door including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm and not exceeding 4 Sqm each complete all as specified and directed.
12
-
-
Taking down chowkats or frames including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm and not exceeding 4 Sqm each complete all as specified and directed.
12
-
-
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
80
-
-
M&L for providing UPVC Door with Shutters. The construction profile for UPVC Door shall be overall frame sectional size 60 x 58 mm with wall thickness 2.70 +/- 0.2 mm extruded sections. The corners shall be plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised steel profile of wall thickness 1.2 mm +/- 0.2 mm. The door shall be fixed to walls using 8 mm dia 80 mm long MS screws minimum 3 Nos on each side. The glazing shall be fixed to door frame with UPVC standard beadings of sectional size 24.05 x 16 mm & 2 mm thick. The bottom portion of door shutter shall be provided with UPVC board 5 mm thick & 1 mtr in height and the balance shall be glazed excluding the shutter frame area. The shutter shall be fixed to frame using 3 nos of 3D hinges. The Door shutter shall be provided with 12 mm thick sheet glass & 5 mm UPVC board with EPDM rubber gasket, one motice lock with powder coated handles and two numbers powder coated MS tower bolts complete all as specified & as directed.
Make : Madhu indrusties/AMD overseas Ltd/Gadli industries.
7
-
-
M & L for UPVC windows with glazing, white colour provided all as per manufacturer's direction and following specifications all as directed. 1. The profile for construction of UPVC window frame shall be made of UPVC material confirming to IS 10151. 2. The frame shall be made of extruded UPVC section having overall dimension of 65 × 50 mm having wall thickness 2 mm ± 0.2 mm 3. Corners of wall frame shall be joined by MS galvanized brackets, joints mitred and plastic welded 4. The hinge side vertical outer frame shall be reinforced with galvanized MS tube of wall thickness 1 mm ± 0.1 mm and the tie rod shall be provided at the bottom of the frame. 5. The profiles should be single chamber system which shall provide high insulation properties. 6. The window system should be glazed with 6 mm thick plane glass fixed in window frame as per manufacturer's instruction .
Note: The entire fixing shall be done as per manufacturer's instructions and specification and as directed by Engg-in-Charge.
Make : Madhu indrusties/AMD overseas Ltd/Gadli industries.
17
-
-
S&F for UPVC Fixed ventilators with glazing made up of (small series) frame 47x50mm, mullion 47 x68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (area upto 0.75 sqm), compirising of UPVC multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape& size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, GI fasteners 100x8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. ((Note: The unit rate quoted by contractor includes the cost of glass and includes necessary modification of ventelator according to the site requirement such as opening for exaust fan, lauvers etc and all other connected accessories. Net opening will be measured for payment purpose.)
Make : Madhu indrusties/AMD overseas Ltd/Gadli industries.
10
-
-
M&L 75mm thick PCC 1:4:8 type D2 (40 mm graded aggregate) as in Sub base floor finished even and fair as in sub base of floor etc all as directed by the Engineer In Charge.
20
-
-
M&L Providing 25mm thick cement concrete type B0, 1:2:4 using 12.5 mm graded stone aggregate .as in floors for levelling course including finish the surface even and fair to receive the floor finish complete all as directed.
50
-
-
M&L for vitrified double charged /Ultracharged jointless tiles 9-10mm thiock light/dark colour (Square/rectangulart) area of each tile exc 0.36 Sqm but n.exc 1.00 Sqm as in floor etc set and jointed in neat cement slurry and pointing in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 complete all as directed and specified.
105
-
-
M & L for 8mm thick Pre-Engineered laminated wood for wall panelling planks of any colour and desigen (as approved by GE) fixed over and including to 8/9mm thick plywood fixed on wall or floor all as per manufacturers instructins and as directed. Make : Florz, Sapphire or equivalant all as specified and directed.
350
-
-
Material and labour for Rendering in Cement Mortar ( 1:6) 20mm thick on stone masonry or other than fair faces of brick work wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
80
-
-
M&L for Granite 18-20mm (any patern) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm thk screed bed in CM 1:3.
10
-
-
M&L for Rounding to edges of stone slabs/ganite slab one edge, such as in steps, cooking platform,sill etc and other similar situation
16
-
-
Material and labour for Aluminium designer powder coated decorative curtain rods antique finish 25mm dia dia, exterior grade 3mm thick with and including side caps, holding clamps and 'F' and 'L' brackets, fixed to wall with PVC rawl plug and brass screws etc., complete all as specified and as directed.
20
-
-
M&L for Providing Gypsum board False ceiling using 12mm thick Gypsum board panels of size as approved by GE, fixed with staples on powder coated standard galvanized iron snap grid frame work of size suitable to fixing Gypsum board using 'T' and angle sections made out of 0.5mm thick PGI sheet, grade of zinc coating 220, bent to shape required as in main member, secondary member, perimeter angle section including provn of G I channel suspender fixed to roof members at the rate of 1200mm c/c and interspaced at 610mm c/c, the main fixing channel shall be fixed through fasteners clips as per manufacturer's instructions with and including plaster of Paris decorative type cornice all around at the junction of wall and ceiling and applying 1.5mm thick wall care putty and applying two coat of ROYAL ASPIRA Asian paints or equivalent make with one coat of primer complete all as specified and as directed. Make : Saint Gobain (Gyproc)/Armstrong/Aerolite.
105
-
-
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work con- forming to Fe.290.Gde-E-165.
60
-
-
M/Lfro preparing new surface of plastered surface of wall surface and applying two coat chalk white primer all as directed by the Engr In charge.(new plastered surface of rear sdie of wall panelling)
80
-
-
Labour for taking down old table/partition etc of any description and in any position fixed on floor/wall surface rafixing the same on the old position /new position as directed by the Engr incharge including necessary repair/screwing,drilling, etc including necessary fillet of required size complete.
47
-
-
Supply and fix 0.9 mm thick Decorative laminated sheet(one side lamination) type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions and as directed by the Engr In Charge.
10
-
-
M & L for pre-engineered hardwood for Cornices/ beading/nosing/moulding as used in pre-engineered wall panelling etc of cross sectional area n.exc 25 Sq Cm as as specified and directed.
106
-
-
Demolition of Brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified
2.5
-
-
M & L for walling of Ashlar stone masonary, Plain, well bonded, build in cement mortar 1:4 complete all as specified and directed.
1
-
-
Extra over stone walling for hammer dressing facings with maximum depression on face from straight edge held against the dressed surface n.exc 20mm to block-in-course masonary as in punched dressed face as in granite and trap stone complete all as specified and directed.
10
-
-
M & L for raised pointing to ashlar masonary or polygonal rubble masonry in Cement mortar 1:4 all as specified and directed,
2
-
-
M &L for precast Cement Concrete block masonry (1:3:6) type C1 with solid block,exceeding 10 cm in width and setting in cement mortar 1: 6 .
1
-
-
M&L two coats of synthetic enamel paint over a coat of red oxide primer including preperation of new steel surfaces over 10cm in width or girth,not otherwise described complete all as specified and as directed
4
-
-
M&L for providing and injecting chemical emulsion for Post construction Antitermite treatment along the Internal/external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.
106
-
-
Taking down carefully old existing Un-Serviceable Al/Copper batten/surface conduit/concealed conduit point wiring (light/exhaust fan/socket/call bell/ Power point) complete including (fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells, Fluorescent tube light fitting) removing the Un-Serviceable retrieved materials from site & making good the disturbed surfaces of walls/floors/ ceilings etc. complete all as specified and directed by Engr-in-Charge.
155
-
-
Taking out unserviceable PVC insulated/sheathed sub main wiring with 2 single core aluminium conductor cable of size upto 10 Sqmm on wooden batten/PVC conduits complete with battens/conduits and shall be removed from site and making good the disturbed surfaces of wall complete all as specified and directed by Engr-in-Charge.
60
-
-
Disconnecting/dismantling of old existing un serviceable DB's any way 240/415 Volts with their old/un serviceable burnt MCBs complete all as specified and directed by Engr-in-Charge.
5
-
-
M&L for point wiring with 1.5 Sq mm, PVC insulated, FRLS,single core, copper conductor cable, 1100 Volt grade, multi stranded drawn through and including medium grade Rigid non metalic PVC conduit concealed in wall/ceiling/roof etc with all necessary accessories for the following controlled by one switch with and including continuous 1.5 Sqmm PVC insulated single core copper conductor cable earth continuity conductor connected to common earth and earth dolly, in the modular flush boxes etc. complete all as specified and directed by Engr-in-Charge.Make of Cable: Havells/Finolex/Polycab,Make of Conduit:Precision/Finolex/Modi. Note: (i) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth. (ii) The cost of cutting chases and making good the disturbed surfaces (if/any) is deemed to be included in the unit quoted rates.(iii) Modular flush boxes will be measured & paid seperately.a) One light/fan/call bell point controlled by one switch
42
-
-
Description all as per ITEM No36.00, One 5 amps 5 Pin socket outlet on independent board
14
-
-
All as per Item No.36 above but with PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor for 16A switch socket.Make of Cable: Havells/Finolex/Polycab, Make of Conduit:Precision/Finolex/Modi. Note: (i) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth (ii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates.(iii) Modular flush boxes will be measured & paid seperately
99
-
-
M&L for sub main wiring with two single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS cable with multi stranded copper conductor of size 2.5 Sq mm drawing through and including medium grade non mettalic rigid PVC conduit concealed in wall/ceiling/roof/Floor etc. including continuous PVC insulated copper conductor single core earth continuity conductor of size 2.5 Sqmm connected common earth complete all as specified and directed by Engr-in-Charge.
Make of Cable: Havells/Finolex/Polycab,
Make of Conduit:Precision/Finolex/Modi
Note:(i) 3 runs of 2.5 Sqmm cable and one run of conduit shall be measured as one unit length.(ii) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth (iii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates
120
-
-
M&L for sub main wiring with two single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS cable with multi stranded copper conductor of size 4 Sq mm drawing through and including medium grade non mettalic rigid PVC conduit concealed in wall/ceiling/roof etc. including continuous PVC insulated copper conductor single core earth continuity conductor of size 4 Sqmm connected common earth complete all as specified and directed by Engr-in-Charge.
Make of Cable: Havells/Finolex/Polycab,
Make of Conduit:Precision/Finolex/Modi
Note:(i) 3 runs of 4 Sqmm cable and one run of conduit shall be measured as one unit length.(ii) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth (iii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates
60
-
-
S&F Modular type socket outlet 2 in 1, ISI Marked 6/16 Amps all as specified and as directed.
Cat No ACVKCWW163 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma
99
-
-
S&F in repairs Modular type switch single pole 16 Amps one way all as specified and as directed. Cat No ACVSXXW161 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma
99
-
-
S&F in repairs Modular type switch single pole 6 Amps one way all as specified and as directed. Cat No ACVSXXW061 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma
56
-
-
S&F in repairs Modular type socket out let 6 Amps 2/3 pin combined ISI Marked 2 module all as specified and as directed. Cat No ACVKSWW063 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma
14
-
-
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 1/2 modules all as directed. Cat No : ACTXMIIX01/02, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma
15
-
-
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 3 modules all as directed. Cat No : ACTXMIIX03, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma
5
-
-
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 6 modules all as directed. Cat No : ACTXMIIX06, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma
15
-
-
Supply & Fixing modular PVC box suitable for fixing switches/sockets of 6 modules all as directed. Cat No : ACNXMIZX06, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma
42
-
-
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 1/2 modules all as directed. Cat No : ACVPPCWV01/02, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma
15
-
-
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 3 modules all as directed. Cat No : ACVPPCWV03, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor
5
-
-
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 6 modules all as directed. Cat No : ACVPPCWV06, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor
57
-
-
Note for item No 40.00 to 50.00:- The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets.
-
-
-
S&F of ceiling rose surface mount PVC/Polycarbonate, isolated body with face bakelite two/three terminal complete all as specified and directed. Make: Havells/CG/Anchor
9
-
-
Supply, install, testing & commissioning of Exhaust fan, PVC body with automatic back shutter louvers 250 mm sweep, 1280 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventillator etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Cat No: Ventil Air - DX White or techno-commercially equivalent in Usha/Crompton. Note :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates
6
-
-
S&F IP=20, Class I, Wall mounted 4 feet LED lighting fixture with integrated electronic driver & polycarbonate difuser complete with all accessories, prewired, 20 W with min 1800 lumens, 6500 K, PF=0.90, CRI=80 and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Havells Cat No:ENDURALINEARPROBS20WLED865SPCSSIND or techno-commercially equiv in Philips/Jaguar
3
-
-
S&F ultra modern, Surface mounted, 18W, 6500K LED Elegant surface panel complete with electronic driver & high brightness LED of Make: Luker cat No: LNPSRS18 or techno-commercially equiv in Jaguar/Philips all as directed by the Engr- in- charge.
3
-
-
S & F ceiling/wall/panel mounted LED TRACKLIGHT (WHITE COLOUR) 18 W or next higher rating suitable for Track Channel 1Mtrs span, CRI 80, CT=6500 K,twin/three core twisted flexible copper conductor cable of suitable size in flexible conduit all as specified and as directed. Make: Cat No LSPT18 of Luker or techno-commercially equivalent in Philips/Jaguar.Note: The cost of making good and matching to the existing surface is deemed to be included in the unit quoted rates.Note:Track Channel shall be measured & paid separately under relevant items.
36
-
-
S & F ceiling/wall/panel mounted LED TRACK CHANNEL (WHITE COLOUR) 1 Mtrs length suitable for mounting of 03 Nos Tracklights 18 W, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible conductor cable of suitable size complete all as specified and as directed. Make : Luker, Cat No : LTM1/2 or techno-commercially equivalent in Philips /Jaquar /Havells. Note:Track Lights 18 W shall be measured & paid separately under relevant items.
12
-
-
S&F LED square shape,ultra modern, recess mounting, 40W, CT=5700K(white) integrated type with high efficiency, electronic driver, surge suppression/protection & high brightness,LED slim panel of size 2' x 2' with suitable frame for fixing the fitting inside gypsum/POP ceiling incl cutting existing false ceiling any type(if reqd) & matching complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size of Make of fitting: Wipro, cat No:CRCO10R040HP57G3, Cat. No of frame : 9180P01089 or techno-commercially equiv in Jaguar/Philips all as directed by the Engr- in- charge.Note:- The rate quoted by contractor is deemed to be included the rate of fitting and suitable frame for fixing the fitting inside false ceiling.
18
-
-
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T, Cat No-BB20320C or techno-commercially equivalent in LEGRAND/SIEMENS.
6
-
-
S&F MCB, SPN, C-Series 240 Volts of capacity 40 Amps with breaking capacity 10 KA. Make-L&T, Cat No-BB20400C or techno-commercially equivalent in LEGRAND/SIEMENS.
3
-
-
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA. Make-L&T, Cat No-BB10(6-32)0C or techno-commercially equivalent in LEGRAND/SIEMENS.
30
-
-
S & F and concealing SPN DB, 12 Way IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge.
Make: L&T, Cat No: DBSPN012DD or techno-commercially equiv in Legrand/Siemens. Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
3
-
-
S&F and concealing MCB DB,DD,TPN 4 Way,415 Volts,IP43,IK-09 with busbar & blanking plates including making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
Make: L&T, Cat No: DBTPN004DD or techno-commercially equiv in Legrand/Siemens.Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
1
-
-
S&F MCB TPN 63A,10KA,'C' Series with adjustable overload & adjustable Short circuit setting complete all as specified & as directed by the Engr-in-Charge.Make: L&T, Cat No BB40630C or techno-commercially equiv in Legrand/Siemens.
2
-
-
S&F MCCB, 4 pole,(63-80)A rating (Ics = 100% Icu),415Volts,25 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel/DB for fixing of MCCB , including spreader terminal, lugs, gland for fixing the cable complete all as directed by the Engr-in-Charge.Make: L&T, Cat No CM91712OOJOOG or techno-commercially equiv in Legrand/ABB..Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
1
-
-
S & F and concealing Sheet metal enclosure , IP-30. IK-08 where MCCBs to be used, 4 Pole, 415 Volt, Single Door with Suitable louvers for heat dissipation and inbuilt neutral link for TPN sustem ISI marked, cable to be cconnected through suitable lugs and gland complete all as specified and as directed by Engr-in-charge. Make : L&T, Cat No CM90996OOOO or techno-commercially equiv in Legrand/Havells.
1
-
-
S & F and concealing non-metallic rigid PVC conduits of external dia 25 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends with aluminium clamp, bolt, nuts etc for fixing complete all as specified and directed. Make:Precision/Finolex/Modi
100
-
-
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI Wire of 4mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 25mm bore medium grade GI protection pipe (upto 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified including taking out the existing u/s earthing accessories. Note: On testing after completion, if the desired earth resistance is not obtained the earthing shall be redone at no extra cost till the entire satisfaction of Engr-in-Charge.
2
-
-
S & F Wall trunking alongwith cover made of lead free PVC, compiles to ROHS flammability at Vo as per UL 94, self fire extinguishing, standard length of 2 mtr suitable for fixing wiring devices with the support of back box and cover plates, the base of the trunking shall have perfortations for anchoring, railing clipprovision to facilitate partition for routing power and data cables separately, the trunking shall confirm to EN 50085-2-1, cable tray with cover clip for fixing the cover of tray, alongwith fixing accessoies for accomodate power, data, communications cables and & other accessories as required at site 230 mm width x 60 mm height complete all as specified & as directed. Model No WDK60230CW (6021891) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.NOTES for Item No 1 : 1) The cable tray shall be made of polyvinylchloride material for protection against electrical shock and interference between electrical and communication line.2) The cable trays should be installed by trained technician to ensure neat installation
110
-
-
S & F barrier strip(Partition) of standard length of 2mtr and 60mm width for separation of cables of different voltages or functions with & including appropriate fastening materials complete all as specified & as directed. Model No 237160 (6023118) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
220
-
-
S & F End piece of size 60X230mm for closing of cable tray at end part & including appropriate fastening materials complete all as specified & as directed. Model No WDKHE60230CW(6162886) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories Internal corner cover of dimension 230 x 60 Model No WDK HI60230 CW (6160395) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
External corner cover of dimension 230 x 60 Model No WDK HA60230 CW (6160980) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
T & Intersection cover of dimension 230 x 60 Model No WDK HK-60230 CW (6162290) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
Flat angle cover of dimension 230 x 60 with Model No WDK HF-60230 CW (6161596) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
Cover clip of dimension 230 x 60 for fixing of tray Model No 2370230 (6023584) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
20
-
-
S& F FRLS-H PVC insulated single core, multistranded copper conductor cable, 2.5 Sqmm or higher size , 1100 volts grade. Make : Finolex/Polycab/Havells.
650
-
-
S& F Cat 6 Cable, 4 Pair, unshielded twisted pair (UTP) industrial cable for LAN network. Make : Finolex/Polycab/Havells.
300
-
-
S & F non- metallic PVC rigid conduit (medium grade) 20 mm dia with all fittings and accessories ISI marked complete.Make: MODI/PRECISION/FINOLEX
450
-
-
S & F non- metallic PVC rigid conduit (medium grade) 25 mm dia with all fittings and accessories ISI marked complete.Make: MODI/PRECISION/FINOLEX
300
-
-
Labour only for removing of existing electrical, data, LAN Network cable along with connection and conduit/Cashing-capping of any size/type and Refixing the same wire/data cable in Cable trunk with fixing accessories.Note:- (i) All types of wire including Conduit in Each RM will be measured as one unit length (ii) Extra wire/PVC conduit of any type if used at site is measured and paid separately under relevant items.
110
-
-
IMPORTANT NOTES : 1) Design / drawing / BOM of the complete Cable Tray system showing the layout & dimensions is to be obtained from OEM strictly keeping in view the actual ground/site requirement & the same is to be got approved from GE before placing final order to the manufacturer.2) Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates.3) The contractor is required to visit the site prior to quoting of the subject item/work so as to ascertain the actual ground requirement. Any further query at a later date shall not be entertained & responsibility of the same shall rest with the contractor.3) The contractor is required to visit the site prior to quoting of the subject item/work so as to ascertain the actual ground requirement. Any further query at a later date shall not be entertained & responsibility of the same shall rest with the contractor.4) The entire work of the Cable Tray system is to be got done from the OEM or their auth Sister Concern/Channel Partners only.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements