Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 May 2023
Closing Date26 May 2023
Tender Amount₹ 48,98,628 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Repair / Maint Of Cooling Appliances And Other Connected E/m Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing in repair of hermetically sealed new compressor for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 310 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

6

-

-

... More
Supply and fixing in repair of condensing coil for refrigerator of capacity 260 to 310 Ltr complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair of Chiller tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repair of Evaporator coil, suitable for refrigerator of 260 to 310 ltrs any make size and type complete all as specified and as directed.

8

-

-

... More
S & F in repair Vegetable tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.

20

-

-

... More
Supply and fixing in repair of ice superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 310 ltrs complete all as specified and directed.

30

-

-

... More
Supply and fixing in repair of in repair electric bulb 20 watt 230v threaded type for refrigetator of Capacity 260 ltrs to 310 ltrs complete all as specified and directed.

30

-

-

... More
Supply and fixing Freezer compartment including door and accessories suitable for refrigeratorr 280, 300, 310 and 320 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed. Make : Godrej/LG/whirlpool

10

-

-

... More
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 300 ltrs complete including taking down existing unserviceable one all as specified and as directed. Make : Godrej/LG/Whirlpool

25

-

-

... More
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas will be measured and paid seperately

8

-

-

... More
Supply and fixing in repair of hermetically sealed new compressor for 165 to 255 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres complete all as specified and as directed. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

8

-

-

... More
Supply and fixing in repair of condensing coil for refrigerator of capacity 165 to 255 Ltr complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair of Chiller tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed.

8

-

-

... More
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.

25

-

-

... More
Supply and fixing in repair of Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed.

18

-

-

... More
Supply and fixing in repair of Evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type complete all as specified and as directed.

9

-

-

... More
M & L for preparing the old painted surface of refrigerator of capacity 165 litres to 335 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and as directed

10

-

-

... More
Note for item No 20 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.

-

-

-

... More
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.

-

-

-

... More
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.

-

-

-

... More
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)

-

-

-

... More
(e) Unless otherwise specified the tints of paint shall be as approved by the GE

-

-

-

... More
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.

-

-

-

... More
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.

-

-

-

... More
Supply and fixing in repair of Vegetable tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed

12

-

-

... More
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and as directed. Make : Godrej/LG/whirlpool

8

-

-

... More
Supply and fixing in repair of Thermostat, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed

30

-

-

... More
Supply and fixing in repair of Gasket, suitable for door of Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and as directed

10

-

-

... More
Supply and fixing of Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

30

-

-

... More
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.

16

-

-

... More
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed as per Make of Refrigerator

20

-

-

... More
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..

30

-

-

... More
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.

100

-

-

... More
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed Make : SRIRAM/GODREJ/RANUTROL

30

-

-

... More
Supply and fixing Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed Make :KELTRON/SRIRAM/EPCOS/BHEL

40

-

-

... More
Supply and fixing Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

35

-

-

... More
M&L for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 320 litres including vacuuming and charging the refrigerant Refrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately

6

-

-

... More
Supply and fixing in repair of hermetic sealed new compressor 1/6 HP suitable for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

4

-

-

... More
Supply and fixing Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.

20

-

-

... More
Supply and fixing Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.

5

-

-

... More
Supply and fixing Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as drected. Make : Whirlpool/Renutrol.

5

-

-

... More
Supply and fixing Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed. Make- Sriram/Godrej/Ranutrol

5

-

-

... More
Supply and fixing Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed

5

-

-

... More
Supply and fixing Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.

5

-

-

... More
Supply and charging of Refrigerant gas, (R-22/R-134(a)/R-407(c)) Freon suitable for cooling equipments like water cooler, refrigerator, deep freezer air conditioner etc of any type and capacity complete all as specified and as directed

500

-

-

... More
S & F multi capacitors 60 µfd for cooling appliances and including taking down existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

20

-

-

... More
S & F multi capacitors 50+5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

30

-

-

... More
M&L for dismantling the transformer from the voltage stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed

-

-

-

... More
(a) 0.5 KVA

15

-

-

... More
(b) 1 KVA

20

-

-

... More
(c) 2 KVA

30

-

-

... More
S & F in repair of following spare parts for 1 KVA to 2 KVA capacity voltage stabilizers complete all as specified and as directed

-

-

-

... More
(a) Relay set ( set of two )

5

-

-

... More
(b) PCB ( Printed circuit board)

6

-

-

... More
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/200 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.

125

-

-

... More
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately

12

-

-

... More
Supply and fixing in repair of hermetic sealed new compressor for water cooler 150 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 ltr and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

8

-

-

... More
Supply and fixing in repair of Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 150 ltr capacity, complete all as specified and as directed Make of Fan motor: AUE/ GEC/HIMSUN

8

-

-

... More
Supply and fixing in repair of Door gasket suitable for lid of water cooler upto 150 litres capacity, complete all as specified and as directed

16

-

-

... More
Supply and fixing in repair of Stainless steel tray suitable for water cooler of 150 Litres capacity complete all as specified and as directed

6

-

-

... More
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed

6

-

-

... More
M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed

5

-

-

... More
Note for item No 64 & 65 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.

-

-

-

... More
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.

-

-

-

... More
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.

-

-

-

... More
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)

-

-

-

... More
(e) Unless otherwise specified the tints of paint shall be as approved by the GE

-

-

-

... More
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.

-

-

-

... More
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.

-

-

-

... More
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately

8

-

-

... More
Supply and fixing in repair of hermetic sealed new compressor for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

6

-

-

... More
Supply and fixing Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one complete all as specified and as directed Make of Fan motor: AUE/ GEC/HIMSUN

8

-

-

... More
Supply and fixing in repair of Candle (filter) 10” size incl taking down existing one complete all as specified and as directed

10

-

-

... More
Supply and fixing in repair of Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and directed.

30

-

-

... More
Supply and fix in repair PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends complete all as specified and as directed

30

-

-

... More
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one complete all as specified and as directed

30

-

-

... More
Supply and fixing gun metal gate valve 15mm dia including GI nipple including taking down existing one complete all as specified and as directed

25

-

-

... More
Supply and fixing in repair of PVC drain out pipe 30mm dia bore as per existing including providing necessary GI clamps, nut bolt etc.complete all as specified and as directed

30

-

-

... More
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately

15

-

-

... More
Supply and fixing in repair of hermetic sealed new compressor for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.

6

-

-

... More
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.

12

-

-

... More
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed

6

-

-

... More
Note for item No 85 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.

-

-

-

... More
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.

-

-

-

... More
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.

-

-

-

... More
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)

-

-

-

... More
(e) Unless otherwise specified the tints of paint shall be as approved by the GE

-

-

-

... More
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.

-

-

-

... More
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.

-

-

-

... More
Supply and fixing in repair of Stainless steel tray suitable for water cooler of 40/ 80 litres capacity complete all as specified and as directed

10

-

-

... More
Supply and fixing in repair of Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.

6

-

-

... More
Supply and fixing in repair of Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed Make of Fan motor: AUE/ GEC/HIMSUN

12

-

-

... More
Supply and fixing in repair of Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.

6

-

-

... More
Supply and fixing Multi capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

40

-

-

... More
Supply and fixing Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL

30

-

-

... More
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed

10

-

-

... More
Note for item No 99 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.

-

-

-

... More
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.

-

-

-

... More
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.

-

-

-

... More
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)

-

-

-

... More
(e) Unless otherwise specified the tints of paint shall be as approved by the GE

-

-

-

... More
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.

-

-

-

... More
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.

-

-

-

... More
Supply and fixing in repair of filter for water cooler of any size any make complete all as specified and as directed.

8

-

-

... More
Supply and fixing in repair of Carbon (filter) 12” size incl taking down existing one complete all as specified and as directed.

10

-

-

... More
Routine repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, for the any models / types, for 11 month period of each aqua guard - 18 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 11 months.

11

-

-

... More
Supply and fixing PCB Card 12 Volt of DC capacity for Aquaguard incl dismantling old unsv and including taking down existing one complete all as specified and directed.

6

-

-

... More
Routine repair and annual maintenance of best water doctor of tank capacity 25/ 44 ltrs installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. HIMA-5NC of flow rate 100 ltr/ hr - 2 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 11 months.

11

-

-

... More
Routine repair and annual maintenance of best water doctor of tank capacity 40/ 80 ltr installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. UV 7 NC of flow rate 200 ltr/ hr - 9 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 11 months.

11

-

-

... More
S & F PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and as directed.

200

-

-

... More
M&L for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections complete all as specified and as directed

6

-

-

... More
M&L for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed

2

-

-

... More
M & L Periodical servicing, calibaration and maintenance of composite synchronous panel of Make: Jackson PCC 3.3 based on auto load management, auto load sharing, auto synchronization panel suitable for 3x 810 KVA stand by DG set comprising of following components:-

4

-

-

... More
INCOMER:- (i) Air circuit breaker 1600A, 415V, 50 Hz -03 Nos (ii) Engine start/stop push button (iii) Digital temperature scanner - 03 Nos (iv) Annunciator -03 Nos (v) Electric buzzer (hooter) - 03 Nos (vi) Digital multifunction meter - 03 Nos (vii) DC volt meter - 03 Nos (viii) indicating LED lights for 3 phase, R, Y, B, Breaker - ON/ OFF, Neutral - ON/OFF, battery charger ON/OFF etc

-

-

-

... More
(b) OUT GOING (i) Air circuit breaker 1250A, 415V, 50Hz – 04 Nos (ii) Breaker central switch – 04 Nos (iii) Auto/ manual selector switch – 04 Nos (iv) Digital ammeter– 04 Nos (v) Indicating LED lights for breaker ON/ OFF

-

-

-

... More
(c) PLC FEEDER (i) PLC board – 01 No (ii) RL circuit board – 04 sets (iii) Digital touch screen for master selection of DG set – 01 No (iv) Cooling fan – 01 No (v) Auto/ manual switch – 01 No (vi) AC busbar 240V – 01 No (vii) DC busbar 240V – 01 No (viii) Digital timer - 01 No (ix) Power contactors 40A – 04 Nos (x) DP MCB 31A – 06 Nos (xi) SP MCB 20A – 05 Nos (xii) Switch socket 5/15A – 01 No (xiii) DC/ AC indicators (xiv) Timer – 01 No Location : LCA Hanger

-

-

-

... More
Note for Item No 116 to 119 :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 months or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature. (vii) Payment shall be made thrice for the period of 11 months proportionately.

-

-

-

... More
Supply and replacement of defective 1 KVA UPS for 30 min back up single phase AC input 160 to 260V and suitable for synchroneous panel board mentioned in the item No. 116.

1

-

-

... More
Repairs and replacement of following defective spares in the synchroneous panel board mentioned in the item No. 116

-

-

-

... More
(a) Digital multifunction meter

1

-

-

... More
(b) Indicating LED lights

6

-

-

... More
(c) Auto/Manual selector switch

2

-

-

... More
(d) Digital ammeter

2

-

-

... More
(e) Digital touch screen for master selection of DG set

1

-

-

... More
(f) Digital timer

1

-

-

... More
(g) Power contactors 40A

3

-

-

... More
(h) DP MCB 32A

3

-

-

... More
(j) SP MCB 20A

2

-

-

... More
Periodical servicing, calibaration and maintenance of Electric Air shower installed at TRCD/CRRW/75 RMU for smooth functioning of hudraulic doors, maintaining required air pressures, lighting etc all as directed.- 15 Nos

45

-

-

... More
Note for Item No 132 :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 to 04 months or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature. (vii) Payment shall be made thrice for the period of 11 months proportionately.

-

-

-

... More
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.

200

-

-

... More
Note for item No 134: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.

-

-

-

... More
S&F in repairs on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed. Make : L & T/ Siemens/ ABB

2

-

-

... More
S&F in repairs on distribution board MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed. Make : L & T/ Siemens/ Legrand

4

-

-

... More
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.

250

-

-

... More
Note for item No 138: (a) 2 runs of 2.5 sqmm cable along with one run of 2.5 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.

-

-

-

... More
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 4 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.

125

-

-

... More
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 6 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.

80

-

-

... More
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.

78

-

-

... More
Supply and fix in repair Triple pole MCB 25 to 63 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.

5

-

-

... More
Supply and fix in repair Triple pole Neutral MCB 16 to 32 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.

5

-

-

... More
Supply and fix in repair Triple pole Neutral MCB 40 to 100 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.

5

-

-

... More
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one 15A Socket & switch point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly including taking down existing point wiring complete all as specified and as directed.

50

-

-

... More
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.

200

-

-

... More
Note for item No 147: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.

-

-

-

... More
Repairs and replacement of following defective spares in the Air compressor of capacity 110 KW Make Atlas copco installed at LCA ETB including reassembling the same after completion of the repairs and testing will be carriedout as per direction of Engr-in-charge. (a) Oil filter cat part No. 1613610500 - 03 Nos, (b) Airfilter element cat part No. 1621574200 - 01 No, (c) Elgi airlube plus -50L-000998115 - 02 Nos.

1

-

-

... More
Repairs and replacement of following defective spares in the Air compressor of capacity 110 KW Make ELGI installed at LCA ETB including reassembling the same after completion of the repairs and testing will be carriedout as per direction of Engr-in-charge. (a) Spin on filter 180 LPM B407701 - 02 Nos, (b) Airfilter kit -B574609 - 01 No, (c) Elgi airlube plus -50L-000998115 - 02 Nos.

1

-

-

... More
Supply & repairs to replacement of Drier suitable for chiller of 45 TR capacity installed at Rotable AC plant

4

-

-

... More
Supply & repairs to replacement of crank case heater suitable for chiller of 45 TR capacity installed at Rotable AC plant.

6

-

-

... More
Supply & repairs to replacement of Carel controller suitable for chiller of 45 TR capacity installed at Rotable AC plant.

1

-

-

... More
Supply & repairs to replacement of power contactor 40 Amps suitable for chiller of 45 TR capacity installed at Rotable AC plant.

3

-

-

... More
Supply & repairs to replacement of power contactor 18 Amps suitable for chiller of 45 TR capacity installed at Rotable AC plant

2

-

-

... More
Carrying out pressure leak test of Central/Package AC plants of capacity 12/15/16.5/30 TR whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately

5

-

-

... More
comprehensive maintenance of fire fighting system and fire alarm system comprising of Smoke detection control panel (to accommodate and sensing signals from wireless smoke detectors), Smoke detector (Photoelectric detection Technology), External wireless siren strobe, wireless repeater to extend the communication range of detectors, Conventional Fire Alarm control panel, IR3 Infra Red flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger - 8 Nos.

11

-

-

... More
Comprehensive maintenance of addressable fire alarm system installed at New ATC Bldg including testing functionality of all components, testing of smoke detector (using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) and cleaning of all devices, replacement of defective spares/ components, comprising of following all as specified and directed. Make – HONEYWELL (MORLEY-IAS) (i) Fire alarm control panel panel micro processed based intelligent four loop upto 200 Detectors in modules. (ii) Multisensory with heater smoke Detector – 262 Nos (iii) Heat detector – 02 Nos (iv) Manual call point – 30 Nos (v) Sounder cum strobe-46 Nos (vi) Response indicator – 67 Nos (vii) Control module – 1 No (viii) Isolator – 12 Nos (ix) Battery backup 7 AH,12 V, Make- MORLEY-IAS -2 Nos.

11

-

-

... More
Note for item No 157 & 158 :- (a)(i) The contractor shall make AMC contract with the original manufacturer or authorised reputed service provider of firefighting systems and arrange their visit periodically as specified in the schedeule. (ii) The repairs/maintenance shall be carried out through the original manufacturers or authorised reputed service provider of fire fighting system only.

-

-

-

... More
(b) Checking oil level in diesel engine, top up if necessary and rectify leakages in system is the responsibility of the contractor. (c) Tightening of nut and bolts. (d) Checking of all electrical connections for the inproper tightness incl checking of charging alternator and battery clamps. (e) Supply and greasing in all grease points. (f) Checking all fire hydrants and ensure smooth function, if found leaking of water arrest the leakages. (g) Checking all pumps glands and if required to replace the gland packing rope. (h) Check all motors for its proper function, if any major defect it should be informed to Engr-in-charge in writing. (i) Test run of complete system is to be carried out once in a month in presence of MES & Air Force reps.

-

-

-

... More
(j) Check all pump pressure and maintain required pressure. (k) The rate quoted shall be deemed to include for carried out all repairs to fire fighting system noticed during the period by providing materials and labour. (l) Contractor is responsible to ensure presence of required water pressure in the system always as directed by the Engineer-in-Charge. (m) The hydrants are installed in scattered locations around 3 sqkm area, nothing extra will be allowed in this respect. (n) The contractor is liable to arrange the AMC team in any time on emergency.

-

-

-

... More
Supply and fixing in replacement of unserviceable battery suitable for smoke detector 9 Volt Alkaline or Lithium Battery complete all as specified and directed.

30

-

-

... More
S&F Non return valve gun metal (ISI marked), PN 1.6 for 150mm dia bore pipe, including taking out old and removal, complete all as specified and directed. Make: Kirloskar/SANT/Zoloto

1

-

-

... More
S&F Fire hydrant landing valve gun metal, type A (Single head outlet) of 63 mm bore conforming to IS-5290 complete including taking down existing one all as specified and directed.

1

-

-

... More
Supply and fix in repairs fire hydrant valve single headed 63mm dia, with ISI marked complete all as specified and directed

1

-

-

... More
Supply and fix in repairs RRL hose type-A suitable for fire hydrant 63mm dia, with ISI marked complete all as specified and directed.

1

-

-

... More
S&F Butterfly valves of 100mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed

2

-

-

... More
S&F CI foot valve 100mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.

2

-

-

... More
Supply and fix in replacement of non return sluice valve 150 mm dia fixed on ERW MS fire fighting pipe line complete all as directed.

2

-

-

... More
Labour for pressure testing of existing 150/80/50 mm DI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut, bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Location :- SRE Bldg, ATC Bldg, DWR, LCA Note : (a) The rate quoted is deemed to be inclusive of T&P required such as air compressor etc for pressure testing (b) The pressure testing procedure of fire fighting system shall be done as per manufacturer's recommendations all as specified and directed.

2

-

-

... More
Supply and fix in replacement of unserviceable RS485 interface module, model : RE-45AR make Ravel suitable for CO2 flooding system installed at SRE bldg complete all as specified and directed.

1

-

-

... More
Comprehensive maintenance of firefighting system comprising of the following accessories :- (a) Fire pump of capacity 60 HP/ 45 KW, 3ph, 415 volts - 01 No (b) Jockey pump 7.5 HP/ 5.5 KW, 3ph, 415 volts - 01 No (c) Diesel driven pump 68 HP/ 52 KW, 137 Cum/Hr discharge (d) Indoor floor mounted electric panel board with switch gears, auto control panel, SCADA panel, pressure gauges for automatic operation of fire pumps, fire hydrants. (e) Sprinkers system. (f) Internal Hydrant system consisting of hydrant valve of oblique pattern, steel cabinet of size 1300x900 mm consisting of 2 x RRL hose reel 15 mtr, 1 x Gun metal branch pipe short length, 1 x CP hose reel of 36 mtr with shut off valve - 12 Nos (g) Fire pipes of ERW MS of sizes upto 150mm dia with control valves and NRVs, pressure gauges, etc - as installed (h) 2 Way fire brigade inlet connectioin - 12 Nos Location – SRE Premises

11

-

-

... More
Note for item No 172 :- (a)(i) The contractor shall make AMC contract with the original manufacturer or authorised reputed service provider of firefighting systems and arrange their visit periodically as specified in the schedeule. (ii) The repairs/maintenance shall be carried out through the original manufacturers or authorised reputed service provider of fire fighting system only.

-

-

-

... More
(b) Checking oil level in diesel engine, top up if necessary and rectify leakages in system is the responsibility of the contractor. (c) Tightening of nut and bolts. (d) Checking of all electrical connections for the inproper tightness incl checking of charging alternator and battery clamps. (e) Supply and greasing in all grease points. (f) Checking all fire hydrants and ensure smooth function, if found leaking of water arrest the leakages. (g) Checking all pumps glands and if required to replace the gland packing rope. (h) Check all motors for its proper function, if any major defect it should be informed to Engr-in-charge in writing. (i) Test run of complete system is to be carried out once in a month in presence of MES & Air Force reps.

-

-

-

... More
(j) Check all pump pressure and maintain required pressure. (k) The rate quoted shall be deemed to include for carried out all repairs to fire fighting system noticed during the period by providing materials and labour. (l) Contractor is responsible to ensure presence of required water pressure in the system always as directed by the Engineer-in-Charge. (m) The hydrants are installed in scattered locations around 3 sqkm area, nothing extra will be allowed in this respect. (n) The contractor is liable to arrange the AMC team in any time on emergency.

-

-

-

... More
S&F CI foot valve 150mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.

1

-

-

... More
S&F Single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single fire hydrant valve and testing complete including taking down existing one all as specified and directed by Engineer - in - Charge.

1

-

-

... More
Taking down existing fire hydrant valves of size 80 mm dia from hydrant post and removing the corrosion,changing the damaged pins from pivot end, softening the shaft of iron wheel and applying the grease for lubrication of fire hydrant valves and refix the same after repair/ rectification complete all as directed by EIC. Note:- The unit quoted rates are inclusive of nut & Bolts, rubber gaskets and other connected items.

1

-

-

... More
Supply and fix in replacement of unserviceable release panel model RE-25AR make- Ravel, UL listed (9th Edison), including switch mode power supply, battery polarity and deep discharge suitable for CO2 flooding system installed at SRE bldg complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of unserviceable CP hose pipe 25 mm dia 36 mtr length including terminal brass jet complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of fire brigade inlet connection 2 way with isolating valve and instataneous gun metal coupling 100/80/63 mm dia including with all accessories complete all as specified and directed.

1

-

-

... More
S&F Butterfly valves of 150mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed

1

-

-

... More
Comprehensive maintenance of firefighting system comprising of the following accessories :- (a) Fire pump of capacity 75 HP/ 55 KW, 3ph, 415 volts - 01 No (b) Jockey pump 10 HP/ 7.5 KW, 3ph, 415 volts - 01 No (c) Diesel driven pump 68 HP/ 52 KW, 137 Cum/Hr discharge (d) Indoor floor mounted electric panel board with switch gears, auto control panel, pressure gauges for automatic operation of fire pumps, fire hydrants. (e) Sprink less system. (f) Internal Hydrant system consisting of hydrant valve of oblique pattern, steel cabinet of size 1300x900 mm consisting of 2 x RRL hose reel 15 mtr, 1 x Gun metal branch pipe short length, 1 x CP hose reel of 36 mtr with shut off valve - 10 Nos (g) Fire pipes of ERW MS of sizes upto 150mm dia with control valves and NRVs, pressure gauges, etc - as installed (h) 2 Way fire brigade inlet connectioin - 10 Nos Location – DWR Premises

11

-

-

... More
Note for item No 83 :- (a)(i) The contractor shall make AMC contract with the original manufacturer or authorised reputed service provider of firefighting systems and arrange their visit periodically as specified in the schedeule. (ii) The repairs/maintenance shall be carried out through the original manufacturers or authorised reputed service provider of fire fighting system only.

-

-

-

... More
(b) Checking oil level in diesel engine, top up if necessary and rectify leakages in system is the responsibility of the contractor. (c) Tightening of nut and bolts. (d) Checking of all electrical connections for the inproper tightness incl checking of charging alternator and battery clamps. (e) Supply and greasing in all grease points. (f) Checking all fire hydrants and ensure smooth function, if found leaking of water arrest the leakages. (g) Checking all pumps glands and if required to replace the gland packing rope. (h) Check all motors for its proper function, if any major defect it should be informed to Engr-in-charge in writing. (i) Test run of complete system is to be carried out once in a month in presence of MES & Air Force reps.

-

-

-

... More
(j) Check all pump pressure and maintain required pressure. (k) The rate quoted shall be deemed to include for carried out all repairs to fire fighting system noticed during the period by providing materials and labour. (l) Contractor is responsible to ensure presence of required water pressure in the system always as directed by the Engineer-in-Charge. (m) The hydrants are installed in scattered locations around 3 sqkm area, nothing extra will be allowed in this respect. (n) The contractor is liable to arrange the AMC team in any time on emergency.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.