Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Sep 2024
Closing Date18 Oct 2024
Tender Amount₹ 47,50,000
Costs
EMD
₹ 95,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677073_1Bid Award Id
ViewTender No
8439/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Ready made PVC Heavy duty earth chamber (250 mm Dia , 260 mm Height) withround cover and minimum 5 ton load bearing capacity, marking earth resistance value on it in painting Make : ERICO or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
60
-
-
S & F 1 run of 10 mm Copper Bonded Steel Round Conductor, minimum copper bonding shall be 254 microns having continuous coin form, the conductor core consists of a low carbon steel grade for improved flexibility. The copper surface of the conductor should provide high conductivity and corrosion resistance properties, should not
crack or tear when conductor is bend well‐suited as a earth lead conductor orequipotential bonding conductor in accordance with the IEC 62305- which shall betested as per IEC 62561-2:2012 standard. Including excavation depth 50 cm for laying round conductor, removing excavated material, return filling or fixing with holder. Material category/ part number shall be listed in UL site.Make ERICO Cat Part No:CBSC10 or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
300
-
-
S & F Clamp Holder made up of 304 grade SS with SS bolt and nut at every 1 m distance of round conductor. The clamp should be suitable Copper bonded Steel round conductor size of 10-mm. Make ERICO or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
180
-
-
M & L for Stainless steel Terminal connections to Equipment Body connection from maintenance free earth pit by mechanical connection using nuts, bolts and all other accessories complete as required by Engr-in-Charge. Make ERICO or technocommercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge. Note: Terminals of existing earth pits shall be cleaned for proper contact with CBSC.
60
-
-
M & L for Cadweld Materials for Connections between Ground Rod with CBSC conductor by Exothermic reaction. Connections to be made with a semi-permanent graphite mould, which shall hold the conductors to be welded. Weld metal must be a mixture of copper oxide and aluminium, should be compliant with IEEE 80 standards and tested as per IEEE 837 -2014 standard. Make ERICO Cat Part No: 150 PLUS F20 or techno-commercially uivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
60
-
-
M & L for 250x50x3 mm common bus bar for earth connection with suitable base clamps & insulators, providing "DD" universal pattern for 8 nos of holes for connections Make ERICO or techno-commercially equivalent of DEHN/SIEMENS compleate all as specified and dirtected by Engr-in-Charge.
10
-
-
Supply & Installation of Point of Entry Protection at PDB Panel, for Enhanced Din Rail Surge Protector Transient Discriminating (TD) Technology withThermal Disconnector fuse of 315A inbuild, Operating Voltage 300-305 V, Maximum Surge Rating 50KA @ 8/20 Micro sec.with Status indication flag per mode,audible alarm and voltage-free contactsTDS, 3PH, 50KA/PH, 240V, TT CONTACTSAs per UL 1449 Edition & IEC 61643 -1 Make ERICO Cat Part No: EDT 310031R or techno-commercially equivalent Note :-
SURGE PROTECTION SYSTEM : Class –II (Point of Entry Protection Sub Circuit Panel)
(a) Enhanced Din Rail Surge Protector Transient Discriminating (TD) Technology (b) Technology with Thermal Disconnect fuse of 315A in build, (c) Operating Voltage 300-305 V, Maximum Surge Rating 50KA @ 8/20 Micro sec.
(d) Status indication flag per mode, audible alarm and voltage-free contacts
(e) Standard: UL 1449 Edition & IEC 61643 -1 (f) Including 20 Mts of Interconnection Conductor with Suitable Sockets Conduit)
6
-
-
M & L for cutting the existing hard standing/PCC/WBM road at a depth not less than 30 X 30 cm in width for passing of pipe line/cable through pipe, returning , filling in complete including finishing the top surfaces by providing cement concrete (1:3: 6) type C2 (using 40 mm graded stone aggregate) 20 cm thick on top . PCC surface finished to a uniform smooth surface , bottom filled with excavated earth complete all as specified and directed by Engr-in-charge.
25
-
-
M&L for cutting grass , bushes, creepers, weeds, unwated plants/growths etc , in and arround the panel board , substation or any other location as directed by Engr in charge /GE and removing rubbish off the premises complete all as specifed and to the entire satisfication of the Engr-in-charge.
200
-
-
Taking down old/ US earthing from Panal / DB and other eqpt and all as specified and directed by Engr-in-charge.
60
-
-
IMPROTANT NOTE FOR SER ITEM NO 1 TO 8 (1) The complete works of the Earthing system is to be got done from the OEM of their authorized sister concern/channel partner only.
(2) Design/Drawing/BOM/ Technical specifications of the complete earthing system showing the layout including dimensions is to be obtained from OEM strictly keeping in view the actual ground requirements & the same is to be got approved from Engr-in-Charge & GE before placing final order to the OEM. (3) Any items missed out in the technical specification , but technically required for efficient working of the system is deemed to be included in the unit quote rates.
(4) The contractor /Firm is required to visit the site prior to quoting of the subject items/work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & resposibility of the same shall rest on the contractor/firm.
(5) Comparative analysis in respect of the items wherever techno-commercially equivlent w.r.t the given Cat/Part/Model ref concerned is to be submitted to the Engr-in-Charge & GE for approval.
(6) The cost of making good the disturbed surfaces (Substation yard Stones and gravel, Walls, Pavement etc) is deemed to be included in the unit quoted rate of relevant items.
(7) On testing if the desired earth resistance is not found according to the relevant Indian Standards it is to be redone to the entire satisfaction of Engr-in-Charge at no extra cost to the Dept after completion of work contractor should submit a detailed Report of Earth resistance test result from OEM and same is to be certified from Engr-in-Charge & GE.
(8) Repair/ Preventive maintenance of the complete earthing system is to be got doen from the OEM /Sister Concern/Channel partner only by the contractor for the entire defect liability period i.e two years from the certificate date of competion & the cost of the same is deemed to be included in the unit quote rates.
(9) If any damage to any electical/communication cables or any pipe lines or any other installations occurs during execution of the work then the same shall be made good by the contractor to the entire satisfaction of the concerned & the cost of the same is deemed to be included in the unit quoted rates.
(10) Testing at an interval of 6 months of the entire earthing system is to be got done drom the OEM/Sister Concern/Channel Partner only by the contractor & report submitted accordingly to the Engr-in-Charge of the entire defect liability period & and the cos of the same is deemed to be included in the unit quote rates.
(11) Purchase Voucher & Manufacturers test certificates to be submitted in original to the Engr-in-Charge.
-
-
-
AGE B/R I DSSC WELLINGTON Framed work as in doors or gates of angle or other section with gusset plates, rails, guard bars, grills, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening Fe 410-W (Gde-E- 250)quality-A as specified and as directed.
3200
-
-
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (any shade) over a coat of red oxide zinc chrome primer all as specified and directed.
200
-
-
M & L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in padding, coping, bed plates, hold fast blocks, levelling courses, etc., including formwork, weathering, slightly rounded or chamfered angles and throating
1
-
-
M&L for signage board made of 3mm thick ACP with EGP reflector sheet with printing on HP 365 Traffic edition laminated with 1170 C clear ECF sheet of 900 mm triangular shape complete all as specifed and as directed.
30
-
-
Material and labour for plain cement concrete 1:2:4 type B2, using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed.
4
-
-
S/F Joist, channel, angle or tee sections, post fixed independently, without connecting plates, etc(cut to ordinary lengths i.e within 20mm of the length indicated quality conforming to Fe 410-W(gde-E-250)quality-A
500
-
-
S&F Poly carbonate Convex Mirror outdoor type 1200mm/1000mm dia mounted and fixed to 80mm bore medium grade MS pipe of 1000mm for NGL grouted with 1:2:4 of PCC 300x300x450mm PCC blocks complete all as specified and as directed.
10
-
-
M&L for Precast cement concrete solid building blocks Type C1 (1:3:6) using 20 mm graded aggregate, exc 10 cm width set in CM 1:6 all as specified and as directed
2
-
-
Material and labour for 15 mm thick rendering in cement mortar 1 : 4 on brick / concrete surfaces, finished fair and even without using extra cement all as specified and as directed.
20
-
-
Supplying and laying of 20 mm nominal dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings of class 1 fixed in walls and ceiling including wall crossing with neceesary clambs for hot water complete all as specified and as directed
2764
-
-
S & F for 20 X 15 mm dia brass Eblow for CPVC complete all as specified and as directed
138
-
-
S & F for 20 mm dia female brass threaded adaptor for CPVC complete all as specified and as directed
69
-
-
S&F in 15 mm dia bore angle cock chromium plated cast copper alloy fancy decorative type with flange plate complete all as specified and as directed
138
-
-
S&F of PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed
138
-
-