Military Engineer Services Tender
... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Feb 2025
Closing Soon28 Feb 2025
Tender Amount₹ 19,50,000
Costs
EMD
₹ 39,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697042_1Tender No
8192/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 70-120sqmm 3.5 core complete all as specified and as directed.
4
-
-
... More
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 150-185sqmm 3.5 core complete all as specified and as directed.
4
-
-
... More
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 240-300sqmm 3.5 core complete all as specified and as directed.
2
-
-
... More
M&L for Painting of LT panel/Feeder pillar any size after cleaning the body surface by rubbing with emery paper to remove existing paint and applying one coat of promer two coat of synthetic enamel paint wring panel name, incoming and outgoing feeder details as specifed and as directed.
20
-
-
... More
Supply and fix heat shrinkable sleeves over bare conductor of LT cable of suitable size as per site after disconnecting cable from terminal box complete all as specifed and as directed.
60
-
-
... More
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ equipments etc., of LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade confirming to IS-7098 (Part-I) 1988 of following size including connecting up using suitable size aluminium lugs testing and commissioning etc., complete all as specified and as directed.
Note : Excavation earth work, sand cushioning and brick protection shall be measured and paid separately under relevant items.
-
-
-
... More
LT UG Cable 2 core x 6 Sqmm
10
-
-
... More
LT UG Cable 2 core x 10 Sqmm
10
-
-
... More
LT UG Cable 2 core x 16 Sqmm
60
-
-
... More
LT UG Cable 2 core x 25 Sqmm
10
-
-
... More
LT UG Cable 3.5 core x 70 Sqmm
10
-
-
... More
LT UG Cable 3.5 core x 95 Sqmm
10
-
-
... More
LT UG Cable 3.5 core x 120 Sqmm
10
-
-
... More
LT UG Cable 3.5 core x 150 Sqmm
10
-
-
... More
LT UG Cable 3.5 core x 185 Sqmm
11
-
-
... More
LT UG Cable 3.5 core x 300 Sqmm
10
-
-
... More
LT UG Cable 4 core x 6 Sqmm
10
-
-
... More
LT UG Cable 4 core x 10 Sqmm
10
-
-
... More
LT UG Cable 4 core x 16 Sqmm
45
-
-
... More
LT UG Cable 4 core x 25 Sqmm
50
-
-
... More
LT UG Cable 4 core x 35 Sqmm
100
-
-
... More
LT UG Cable 4 core x 50 Sqmm
10
-
-
... More
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ equipments etc., of HT UG cable XLPE insulated, sheathed with multistranded aluminium conductor armoured with galvanised steel wire/ taps, 22000 volts, earthed grade conforming to IS specifications of size 3 core x 185 sqmm including connecting up using suitable size aluminium lugs testing and commissioning etc., complete all as specified and as directed.
Note : Excavation earth work, sand cushioning and brick protection shall be measured and paid separately under relevant items.
10
-
-
... More
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of under ground cables, pipes/pipe lines, etc. and the like not exc. 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
104
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type soil complete all as specified and as directed.
89
-
-
... More
Removing excavated soil to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.50 Metre above the starting point complete all as specified and as directed.
16
-
-
... More
Supply, lay / spread in trenches clean dry M - sand for cushioning of cable to the full width of excavated trench, 8cm thick before laying cable and 15cm thick above the cable, gently punned down, stretching and testing of cable on transformer yard etc., complete all as specified and as directed.
Note : Punned thickness only will be considered or payment.
1
-
-
... More
Supply and lay kiln burnt sub class 'B' bricks of size 230mmx115mmx75mm of 45Kg/Sq Cm laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable etc., complete all as specified and as directed.
174
-
-
... More
M&L for replacement of blue silica gel crystal in breather complete as specifed and directed.
2
-
-
... More
Earthing complete with Copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to Copper strip 20 x 3 mm size and earthing lead protected with 50 mm dia GI pipe light grade filling around with charcoal dust and salt and connected to Copper strip by means of Copper nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia bars at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 5 of SSR Part - I 1991 including testing complete. (Copper strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately.
2
-
-
... More
M&L for Painting of transformer after cleaning the body surface of 400KVA/500KVA transformer by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of metal primer and two coat of synthetic enamel paint incl writing incoming/outgoing cable details of transformer/LT Panel capacity all as directed.
2
-
-
... More
M&L for Dehydration/filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 35 to 40 KV at 2.5 mm gap in existing position of transformer (400KVA / 500 KVA) and including topping up of oil required quantity all as directed.
2
-
-
... More
M&L for replacement of rubber gasket set, rusted bolt/nuts of 400KVA / 500KVA Indoor type transformer complete all as specified and directed.
2
-
-
... More
S&F in replacement of pin type, porcelain, vitrious, white, brown or green insulator including galvanized mild steel spindle, two galvanised iron washers,and galvanised iron nut, min 150 mm hight,100 mm dia for 22KV volt grade complete all as specified and directed.
6
-
-
... More
M&L for Painting of Two pole structure after cleaning the body surface of by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of metal primer and two coat of synthetic enamel paint all as directed.
2
-
-
... More
Supply and fix lightening arrestor HT 22KV 10 KA station class on 2 pole structure all as specified and directed
2
-
-
... More
Material and labour for provision of earth continuity conductor 32 X 6mm GI stnp with saddles and fixing screws etc. for roof conductors and down conductor buried in ground or drawn in pipe all as specified and directed
30
-
-
... More
Material and labour for light grade GI pipe 40mm dia for protection of GI strip earth strip all as specified and directed
30
-
-
... More
Repair to LT panel door hinges by replacing with hinges having lubricating hole by welding as directed
15
-
-
... More
Maintenance of two pole structure by applying of petroleum jelly on the male and female contactors,cleaning of insulators, restringing of lines, replacement of burnt jumpers, replacement of damaged conductor, tightening of all nut and bolts to avoid any sparking and replacement of earth strip insulator complete all as specified and directed.
4
-
-
... More
Supply of Heavy duty rubber cable protection Hump/ Ramp Traffic Bump of 18000lbs Capacity with Durable Cable Floor Cover for protection of temporary cable crossing the road from pinching due to vehicle passing over the cable of size 500mm x 50mm size with length of 5m all as specified and directed.
3
-
-
... More
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 10 KA fixed directly on board/panel/wall including taking down old unserviceable MCCB and taken as credit complete all as specified and as directed.
2
-
-
... More
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 10 KA fixed directly on board/panel/wall including taking down old unserviceable MCCB and taken as credit complete all as specified and as directed.
1
-
-
... More
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA fixed directly on board/panel/wall including taking down old unserviceable MCCB and taken as credit complete all as specified and as directed.
2
-
-
... More
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 amps, with rupturing capacity 36 KA fixed directly on board/panel/wall including taking down old unserviceable MCCB and taken as credit complete all as specified and as directed.
1
-
-
... More
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 250 amps, with rupturing capacity 36 KA fixed directly on board/panel/wall including taking down old unserviceable MCCB and taken as credit complete all as specified and as directed.
1
-
-
... More
Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of four pole 40 to 100 A of current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
5
-
-
... More
Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of SPN 40 to 63A current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
2
-
-
... More
Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of SPN 32 A current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
6
-
-
... More
Supply and fixing of stainless steel rail MCB channel of standard side inside Distribution box as specified and directed
10
-
-
... More
Supply of Aluminium end terminals/lugs suitable for XLPE conductors of size 6,10,16,25,35,50,70,95,120,185,300 sqmm (each set of 10 Nos) complete all as specified and as directed.
1
-
-
... More
M&L for servicing and calibration of VCB at CGRA/OTM including relay setting, disconnecting electric connections and taking out busbar.insulator,CTs and measure IR value using 2.5 KV megger,Clean the inner compartment with moisture free using external heater load checking , distribution & proper checking & fixing of nuts & bolts of cable connections, changing of thermostat, if necessary, greasing where ever required include earth testing etc., complete all as specified and as directed.
Note: Servicing should be carried out through OEM ( i.e. Schneider) authorised service provider only
2
-
-
... More
M&L for taking down LT Panel door shutter area exc. 1sqm & n. exc 2 sqm and refixing the shutters in same opening properly complete all as specified and as directed.
1
-
-
... More
M&L for shutters of any description area exc. 1sqm & n. exc 2 sqm each resecuring or pivot adjusting without taking down as specified and as directed by Engineer-in-Charge
1
-
-
... More
Supply, lay Double walled corrugated High Density Polyethylene pipe (DWC-HDPE pipe) of 120mm and 103 mm as outer dia and inner dia respectively with all bends and angles having corrugated on the outer wall and plain surface on inner wall confirming to IS-14930 Part-I and Part-II complete with necessary HDPE fittings for protection of 1.1 KV Grade under ground cable directly buried in ground at a depth of 60 cm below GL including neceaasry earth work and returning filling of excavated soil and removing surplus earth off premises complete all as specified and as directed.
10
-
-
... More
Supply and fix cable jointing kit for 22 KV grade cable for Outdoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 185 sqmm all as specified and as directed.
1
-
-
... More
Supply and fix in repairs/ replacement of 22 KV, 100 Amps, drop out fuse assembly, porcelain channel type, each set consisting of set of three complete all as specified and as directed.
2
-
-
... More
Supply and fix in replacement of sealed lead acid battery 42Ah 12V suitable for VCB spring charging system including taking down unserviceable battery any type capacity complete all as directed. Make Exide Powersafe plus EP 42-12V SMF or equivalent of Amaron / Luminous
12
-
-
... More
REPAIRS TO STREET LIGHT AND ALLIED WORKS
-
-
-
... More
Supply and fix in repairs/replacement of LED light fitting 19W 5700K made up of pressure die cast housing with toughed glass with optics/diffuser IP66 protection complete as per Philips Cat No. BRP042 LED 19 CW MR S1 PSU GR or technocommercially equivalent of other specified makes including taking down unserviceable CFL security light fittings of any type any watts complete all as specified and directed.
6
-
-
... More
Supply and fix in repairs/replacement of LED light fitting 45W, 7500K made up of pressure die cast housing with toughed glass with optics/diffuser with suitable electronic driver IP66 protection complete all as per Philips Cat No BRP031 LED45 CW MR PSU GR DX or techno-commercially equivalent of other specified makes including taking down unserviceable HPSV/MH street light fitting and type any watts completed all as specified and directed.
9
-
-
... More
Supply and fix in repairs/replacement of LED Flood light fittings 200W, 5700K made up of pressure die cast housing with toughed glass with optics/diffuser with suitable integral electronic drives, IP66 protection complete all as per Philips Cat No. BVP184 LED196 CW FG WB 200W PSU or technocommercially equivalent of other specified makes including taking down unserviceable flood ligh fitting any type any watts from high mast pole complete all as specified and as directed.
1
-
-
... More
Supply and fix in repairs/replacement of LED Flood light fittings 150W, 5700K made up of pressure die cast housing with toughed glass with optics/diffuser with suitable integral electronic drives, IP66 protection complete all as per Philips Cat No. BVP183 LED140 CW FG WB 150W PSU or technocommercially equivalent of other specified makes including taking down unserviceable flood ligh fitting any type any watts from high mast pole complete all as specified and as directed.
1
-
-
... More
Supply and fix in repairs/replacement of LED Flood light fittings 100W, 5700K made up of pressure die cast housing with toughed glass with optics/diffuser with suitable integral electronic drives, IP66 protection complete all as per Philips Cat No. BVP142 LED100 CW FG GR PSU or technocommercially equivalent of other specified makes including taking down unserviceable flood ligh fitting any type any watts from high mast pole complete all as specified and as directed.
1
-
-
... More
Supply and fix in repairs/replacement of LED Flood light fittings 70W, 5700K made up of pressure die cast housing with toughed glass with optics/diffuser with suitable integral electronic drives, IP66 protection complete all as per all Philips Cat No. BVP141 LED70 CW FG GR PSU or technocommercially equivalent of other specified makes including taking down unserviceable flood ligh fitting any type any watts complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement of tubular battery 75Ah 12V suitable for solar light fittings as per Exide Model No. 6LMS75L 75AH Solar Battery or equivalent in Amaron/SF sonic/Tata including taking down unserviceable battery any type capacity complete all as directed.
8
-
-
... More
Supply and fill distilled water for 12V, upto 100AH battery as per requirement complete all as specified and directed.
200
-
-
... More
Material and Labour for recharging solar battery by replacing the old acid, fill with new distilled water/acid complete all as specified and as directed.
19
-
-
... More
Material and labour for shifting of solar street tubular pole 4 metre long with battery and battery box,cross arms,clamps and refixing in new location as specified/ directed including servicing,rectifiying defects and necessary earth work, PCC 1:2:4 using 20 mm graded aggregate for pole foundation and coping and Painting with synthetic enamel paint over concrete surfaces and writing numbers etc complete all as specified and as directed.
2
-
-
... More
Supply and fix in repair All-in-one Solar Street light Solar light: 4000 luminous, 6500K, Battery: 15Ah, 3.2 V Lithium Ferro Phosphate battery Solar panel: 12W, 4.5V, Poly crystalline panel along with PWM Charge Controller along with IR Remote control configurable dimmer all as per Philips Cat No. BRC010 LED40/765 or techno-commercially equivalent of other specified makes including taking down unservicable solar panel and taken as credit complete all as specified and as directed.
8
-
-
... More
Securing and fixing solar panels in position using MS angle iron, nuts, bolts etc including welding in panels and drilling holes etc., complete all as specified and as directed
10
-
-
... More
Supply and fix in repair battery compartment box made up of PVC suitable for battery locking arrangement and fixing accessories including writing of pole number etc complete all as speciifed and as directed.
3
-
-
... More
Material and labour for Water washing and adjusting in position by replacing bolts, nuts, support of the solar panels
25
-
-
... More
Supply and fix in repair of twin core 1.5sqmm multi stranded copper conductor PVC insulated and shethed cables to connect from junction box to street light fittings through inside of pole and including taking down unserviceable copper cable any size any type from pole complete all specifed and as directed.
20
-
-
... More
Trimming of tree branch around the street/solar light and remove the branchs out side the MD land complete all as directed.
50
-
-
... More
Supply and fix in repairs PVC junction box, factory made of size 180 x 290 x 110 mm with one No of SP MCB of 06 Amp rating class-B and 3 nos connector fixed on pole with necessary clamps and bolts etc duly painted with two coats of aluminium paint over a coat of red oxide primer including connecting with street light cable along with replacing the glands all as directed at site complete all as specified and as directed.
5
-
-
... More
Supply and fix in repairs GI tube light grade 32mm dia for fixing of street lights including clamps, nut bolts etc bend to shape complete all as specified and as directed.
10
-
-
... More
Disconnecting Electrical connections and dismantling taking down of high mast lantern carriage and lowering at ground level by using crane and re-fix in same position after servicing/ repairing of motor, Double drum winch with toping up gear oil, pully assembly etc.and replacement of rope along with painting of the pole including all allied fitting and fixture complete all as directed.
1
-
-
... More
Material and Labour for preparing the surface of RCC pole 9.0 mtr long with applying one coat of white cement based paint including numbering the poles with white colour paints over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed.
50
-
-
... More
Material and Labour for removing the damaged the RCC pole of any height and the corresponding electric cables and depositing where directed complete all as specified and as directed.
2
-
-
... More
Material and Labour for preparing the surface of steel tubular pole 11.00 mtr long with cross arms, clamps etc and applying one coat of aluminium paint including numbering the poles with white colour paints over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed.
50
-
-
... More
Material and Labour for preparing the surface of steel tubular pole 8.50 mtr long with cross arms, clamps etc and applying one coat of aluminium paint including numbering the poles with white colour paints over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed
10
-
-
... More
Material and Labour for preparing the surface of steel tubular pole 4.00 mtr long with cross arms, clamps etc and applying one coat of aluminium paint including numbering the poles with white colour paints over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed
10
-
-
... More
Supply only Battery Terminal Compound (High Temperature white petroleum Jelly)
2
-
-
... More
Supply only of waste cotton/cloth
6
-
-
... More
Supply and fix PVC Conduit pipe of size 25mm clamped on the PCC Street Light pole at a spacing of 1m all as specified and as directed
21
-
-
... More
INTERNAL ELECTRIFICATION AND ALLIED WORKS
-
-
-
... More
M&L for dismantling ceiling fan, remove wornt out bearing, burnt winding and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating icluding fixing of ball bearing/bush complete all as specified.
120
-
-
... More
M&L for dismantling exhaust fan 300mm sweep, remove wornt out bearing , burnt winding and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating icluding fixing of ball bearing/bush complete all as specified.
40
-
-
... More
Supply and fix in replacement of capacitor 2.5 mfd suitable for ceiling fan complete all as specifed and directed.
150
-
-
... More
M&L for dismantling wall mounting motor, remove wornt out bearing, burnt winding and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating icluding fixing of ball bearing/bush complete all as specified.
2
-
-
... More
Taking down carefully storage type water heater (Geyser) of any type and any make upto 50 Litre capacity after disconnecting all electric connection from any height, bringing down to floor descaling the inner container, heating element, base assembly etc. by using diluted hydrochloric acid and cleaning thoroughly, filling the inner container with water and checking and arresting leakage if any, reassembling the geyser after servicing and replacing unserviceable spare parts and refixing including making water connections and testing on completion complete all as specified and directed.
Notes:
(i) Spare parts like heating element, thermostats, etc., shall be measured and pair separately.
2
-
-
... More
Supply only new heating element of capactity 1.5 KW with rubber gasket thread type/ press type/ triangular/ circular type suitable for geysers complete all as specified and as directed.
2
-
-
... More
Supply only thermostat automatic cut off with ISI mark suitable to geysers of any range from 20° C to 90° C all as specified and directed.
2
-
-
... More
Supply only phase indicating neon lamp round or rectangular type suitable for single phase 230 volts, 50Hz AC for respective make of the geysers. Note: Set of two lamps containing green and red colour shall be counted as one unit.
2
-
-
... More
M&L for checking of ceiling fan clamps/split pin, rubber bushes,canopy condition and replace the above items if unserviceable to ensure safety hanging of ceiling fans at CGRA qtrs/OTM accn area complete
100
-
-
... More
Supply and fix louver suitable exhaust fan 300mm with protection mesh and without shutter to avoid birds entering including taking down unserviceable louvers complete all as specified and directed.
5
-
-
... More
Supply and fix LED light fittings 18W, 230V, 1x1ft square size surface mount min 6000K, 90lumens/watt with suitable integeral electronic drivers in CRCA sheet housing all as per Crompton Cat No.LCTLRN-18-CDL or technocommercially equivalent of other specified makes including connecting up with driver with three core flexible copper conductor cable of suitable size from ceiling rose to fitting and taking down old fittings any type complete all as specified and as directed.
5
-
-
... More
Supply and fix of LED light fittings 18W, 230V, 1x1ft square size recess mount type min 6000K, 90lumens/watt with suitable integeral electronic drivers in CRCA sheet housing all as per Crompton Cat No LCTLSN-18-CDL or technocommercially equivalent of other specified makes including connecting up with driver with three core flexible copper conductor cable of suitable size from ceiling rose to fitting and taking down old fittings any type complete all as specified and as directed.
5
-
-
... More
Supply and fix LED light fittings 24W, 230V, 2x2ft square size recess mount type min 6000K, 90lumens/watt with suitable integeral electronic drivers in CRCA sheet housing all as per Crompton Cat No LCTLRP-24-FO-CDL or technocommercially equivalent of other specified makes including connecting up with driver with three core flexible copper conductor cable of suitable size from ceiling rose to fitting and taking down old fittings any type complete all as specified and as directed.
2
-
-
... More
Supply and fix 4 feet 1 x 20 Watts LED light fitting, basic all purpose surface and wall mounted LED batten with polycarbonate housing with integrated electronic drive all as per Cat No. LUMILINEBS20WLED865 SPCWH of Havells or Light Linear of Crompton or technocommercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging/fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc., including taking down old fitting complete all as specified and directed.
30
-
-
... More
Supply and fix in replacement of MCB SP 40Amps, 'C' curve, 10KA complete all as specifed and directed.
3
-
-
... More
Supply and fix in replacement of MCB SPN 40Amps, C curve complete all as specifed and directed.
3
-
-
... More
Material and labour for point wiring complete with two runs of 1.5 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, copper conductor FRLSH cable of 1100V grade conforming to IS - 694 drawn through and including new PVC casing and caping of suitable size with accessories fixed on surfaces of wall / floor and fixed on ceiling/roof etc, including cutting chasing for provision of modular metal flush sunken box of adequate size for mounting modular switches, sockets, regulators etc. and provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified for one light/fan point controlled by one switch. Note : (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) Modular metel flush box, frame and cover plate shall be measured and paid separately.
2
-
-
... More
All as per item No.88 but wiring for one 3pin socket outlet 5 Amps on independent board.
2
-
-
... More
Material and labour for point wiring complete with two runs of 2.5 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, copper conductor FRLSH cable of 1100V grade conforming to IS - 694 drawn through and including new PVC casing and caping of suitable size with accessories fixed on surfaces of wall / floor and fixed on ceiling/roof etc, including cutting chasing for provision of modular metal flush sunken box of adequate size for mounting modular switches, sockets etc. and provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified for one15 Amps power point on independent board. Note : (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) Modular metel flush box, frame and cover plate shall be measured and paid separately.
2
-
-
... More
Material and labour for submain wiring complete with two runs of 4.00 Sqmm single core, multistranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new PVC casing and caping of suitable size with accessories fixed on surfaces of wall / floor and fixed on ceiling/roof etc, with one run of 4.00 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to AC metal clad/DBs including taking down existing submain wiring with conduit any type complete all as specified and as directed. Note: Three runs of 4.00 Sqmm multistranded cable one run of PVC casing and caping shall be considered as one unit length.
10
-
-
... More
S&F Modular switch 6 Amps, single pole,oneway,1 module complete all as specified and as directed
10
-
-
... More
S&F Modular socket outlet combination, 6 A,2/3 pin combined, 2 module, complete all as specified and as directed
10
-
-
... More
S&F Modular switch 1 way 16A, 1 module complete all as specified and as directed
10
-
-
... More
S&F Modular socket outlet combination,16A, 6 pin combined 2 module, complete all as specified and as directed
10
-
-
... More
S&F Modular white cover plate with frame, suitable for 2 module complete all as specified and as directed
2
-
-
... More
S&F Modular white cover plate with frme, suitable for 3 module complete all as specified and as directed
2
-
-
... More
S&F Modular white cover plate with frame, suitable for 4 module complete all as specified and as directed
2
-
-
... More
S&F Modular metal flush box suitable for 1/2 module complete all as specified and as directed
2
-
-
... More
S&F Modular metal flush box suitable for 3 module complete all as specified and as directed
2
-
-
... More
S&F Modular metal flush box suitable for 4 module complete all as specified and as directed
2
-
-
... More
Material and labour for submain wiring complete with two runs of 6.00 Sqmm single core, multistranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia fixed on surfaces of wall / floor and fixed on ceiling/roof etc, with one run of 6.00 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to AC metal clad/DBs including taking down existing submain wiring with conduit any type complete all as specified and as directed. Note: Three runs of 6.00 Sqmm multistranded cable one run of PVC conduit shall be considered as one unit length.
10
-
-
... More
Supply and Fix Call bell ding dong, AC, 240 V, single pole, including taking down old unserviceable calling bell complete all specified and directed.
10
-
-
... More
Supply and Fix Bell push, flush type, single pole, 5/6 Amps, AC, 240 volts including taking down old damaged Bell push complete all specified and as directed.
10
-
-
... More
Supply and fix Ceiling rose, surface mount type, PVC/ Polycarbonate, with face bakelite 65 x 50mm three terminals, 240 Volt, AC Single phase including taking down old damaged ceiling rose complete all as specified and as directed.
10
-
-
... More
S&F in replacement of switch piano flush button, single pole, one way 5 Amps complete all as specifed and directed.
10
-
-
... More
S&F in replacement of switch socket combination 2 in1, 3 pin, 5 Amps, flush type complete all as specifed and directed.
10
-
-
... More
S&F in replacement of switch socket combination multipurpose, 2 IN 1, 3PIN,5/15A flush type complete all as specifed and directed.
10
-
-
... More
S&F in replacement of stepped type electronic fan regulator flush type socket type complete all as specifed and directed.
30
-
-
... More
M&L for Painting of ceiling fans, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and numbering of ceiling fan of any size complete all as directed.
10
-
-
... More
Supply, fix, connecting and testing factory made, MCB distribution board, (MCB DB), TPN, 4 way, 415 Volts, Vertical type, double door having degree of protection IP 43, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link, earth bar and din rail etc., complete concealed and fixed flush to wall and making good the disturbed surfaces including, disconnecting electric connections, dismantling from position unserviceable DBs complete all as specified and as directed. Note: MCBs will be measured and paid separately.
1
-
-
... More
Supply, fix, connecting and testing factory made, MCB distribution board, (MCB DB), double door, SPN, 12 way, 240 Volts, having degree of protection IP 43, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link, earth bar and din rail etc., complete concealed and fixed flush to wall and making good the disturbed surfaces including, disconnecting electric connections, dismantling from position unserviceable DBs complete all as specified and as directed. Note: MCBs will be measured and paid separately.
1
-
-
... More
Supply and fix 9W Anti-Bac LED bulb with suitable integral electronic drives including taking down old CFL bulb complete all as specified and as directed.
Make:Crompton Cat No.LED 9W ANTIBAC - CDL or equivalent in PHILIPS/HAVELLS/WIPRO/BAJAJ.
30
-
-
... More
Supply and fix in replacement of Modular TV antenna socket outlet as per Anchor Cat No.21157S or technocommercially equivalent of other specified makes complete all as specified and as directed
2
-
-
... More
Supply and fix in replacement of Modular Telephone socket outlet as per Anchor Cat No.20857S or technocommercially equivalent of other specified makes complete all as specified and as directed
2
-
-
... More
Supply and fix in repair single phase electronic digital energy meter 5 -30 A inbuilt CT & PT with LCD display suitable for direct measuring including Meter Cupboard with Hinge & Celling arrangement moulded in Engineering Plastic complete all as specified and as directed. Make:HPL/ Havells/ L&T
3
-
-
... More
Supply and fix in repair exhaust fan wings (set of 4wings) of suitable size as per site requirement all as specified and directed.
3
-
-
... More
Supply and fix 2 feet 1 x 10 Watts LED light fitting, basic all purpose surface and wall mounted LED batten with polycarbonate housing with integrated electronic drive all as per Cat No.LUMILINEBS10WLED865SPCWH of Havells or technocommercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging/fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc., including taking down old fitting complete all as specified and directed.
45
-
-
... More
Supply and fix in repair three phase electronic digital energy meter 10 -60 A inbuilt CT & PT with LCD display suitable for direct measuring including Meter Cupboard with Hinge & Celling arrangement moulded in Engineering Plastic complete all as specified and as directed.
Make:HPL/ Havells/ L&T
2
-
-
... More
Supply of LED light fittings 5W, 230V, 1ft, wall mount type min 6500K with suitable integral electronic drives all as per Crompton Light Linea 5 W 1 feet or technocommercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging/fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc., including taking down old fitting complete all as specified and directed.
5
-
-
... More
Supply and fix in repair/ replacement of new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia complete all as specified and as directed
20
-
-
... More
Supply and fix in repair/ replacement 18W LED light 4 pin type all as per Philips Cat No. LED PLL 4P 18W/865 2G11 or technocommercially equivalent of other specified makes all as specified and as directed
20
-
-
... More
Supply and fix in repair/ replacement 9W round type recess mounted LED light of diameter 185mm and height of 100mm all as per Philips Cat No.DN195B LED20S-6500 PSU WH S2 or technocommercially equivalent of other specified makes all as specified and as directed
2
-
-
... More
S&F Modular white cover plate with frame, suitable for 1 module complete all as specified and as directed
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%