Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Water Storage And Supply
Eprocure
Opening Date17 Dec 2024
Closing Date14 Jan 2025
Tender Amount₹ 89,49,000 
Notes
Download

Costs

Summary

Repair / Maintenance Of Water Supply Plumbing Network, Pump, Motors And Certain Misc Water Supply Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only water seal suitable for 25HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Taking down defective centrifugal pump set 15 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

5

-

-

... More
Supply only Ball bearing suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
Supply only coupling bolt with nuts suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

10

-

-

... More
Supply only coupling Rubber Bush suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

10

-

-

... More
Supply only split casing gaskets suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
Supply only shaft sleeves suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
Supply only Air cock grease nipple suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
Remetaling of existing shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 15HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
Supply only water seal suitable for 15HP motor pump as per manufacturer's design complete all as specified and as directed.

5

-

-

... More
M&L Cleaning of RCC UG sumps of the following capacities by involving of the followings 09 (Nine) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete (iv) Removing dirt and sludge by vaccum pump (v) Anti- Bacterial Tratment of inside of tank which is effective against all pathogens all complete. (vi) Sterilization of the tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash internal surfaces. (viii) Replace nylon net for vent pipes & man hole cover (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc

-

-

-

... More
Note for item No 19 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 1500/- per day.

-

-

-

... More
(a) Semi underground sump of capacity two tank 200000 gallon capacity at KVPH (No 6)& Booster pump House at technical area.

4

-

-

... More
(b) Semi underground sump of capacity two tank 150000 gallon capacity at KVPH - 02 nos(No 4)& (No 5) .

4

-

-

... More
(c) Semi underground sump of capacity two tank 80000 gallon each at KVPH - 01 No (No 02)

2

-

-

... More
(d) Semi underground sump of capacity 50000 gallon KVPH - 01 No , LCA PH - 01 No

4

-

-

... More
(e) Semi underground sump of capacity two tank 20000 gallon at KVPH- 01 No, booster pump- 01 No, LCA PH - 01 No .

6

-

-

... More
(f) Semi underground sump of capacity 15000 gallon at MES Key person.

2

-

-

... More
(g) Underground sump of capacity 10000 gallon single compartment at MES Key person.

2

-

-

... More
Taking down defective centrifugal pump set 30 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing capacity at least for 8 hrs on load, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : Kirloskar Note : (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only Ball bearing suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only split casing gaskets suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only Air cock grease nipple suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only coupling bolt with nuts suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only coupling Rubber Bush suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only shaft sleeves suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only water seal suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
M&L Taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case of services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed..

4

-

-

... More
Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only water seal suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only bronze impeller suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
M&L Taking down defective centrifugal pump set 60 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately as supply only in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

1

-

-

... More
Supply only Ball bearing suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Supply only Air cock grease nipple suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Supply only split casing gaskets suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Supply only coupling bolt with nuts suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only coupling Rubber Bush suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only water seal suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Supply only shaft sleeves suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
Supply only bronze impeller suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.

1

-

-

... More
M&L Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary testing of windings to findout any core loss in windings, test of insulation resistance, etc. and applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryout re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity upto 60 HP. Note:- (i) Rewinding of stator and rotor if required will be measured and paid seperately. (ii) Cost of Transportation to and from the local workshop is deemed to be incl in the quoted rate.

1

-

-

... More
M&L Rewinding of stator core with proper gauge and amount of highly insulated copper wire as per existing, testing complete.

1

-

-

... More
M&L Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as per existing, testing complete.

1

-

-

... More
M&L Disconnecting the delivery pipe line of submersible pump sets of any capacity from water mains to take out by lifting column pipe of 50mm dia alongwith submersible cable and pump set from shallow well of any depth for servicing of submersible pump sets of any capacity at site, re-assembling the column pipe and re-connection of submersible cable with pump set and lowering in the shallow/open well, testing and commissioning all as specified and directed. Note:- (a) The cost of tools and equipments reqd for lifting/ lowering of pipes and pumps are deemed to be included in the quoted rate.

3

-

-

... More
M&L Dismantling pump and motor of submersible pump set of capacity upto 10 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below as supply only. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

3

-

-

... More
Supply only GM Bush.

3

-

-

... More
Supply only sleeve MS key for impeller

6

-

-

... More
Supply only SS coupling bearing.

6

-

-

... More
Supply only oil seal thrust bearing.

3

-

-

... More
Supply only Sand Guard.

3

-

-

... More
Taking down defective centrifugal pump set 20 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only Ball bearing suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only coupling bolt with nuts suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only coupling Rubber Bush suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only split casing gaskets suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only shaft sleeves suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only Air cock grease nipple suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only water seal suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Taking down defective centrifugal pump set 12.5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only Ball bearing suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only coupling bolt with nuts suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only coupling Rubber Bush suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

4

-

-

... More
Supply only split casing gaskets suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only shaft sleeves suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only water seal suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Supply only Air cock grease nipple suitable for 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 12.5HP motor pump as per manufacturer's design complete all as specified and as directed.

2

-

-

... More
Dismantling pump and motor of submersible pump set for capacity 3 HP to 5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 200 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

8

-

-

... More
Supply only GM Bush.

8

-

-

... More
Supply only sleeve MS key for impeller

16

-

-

... More
Supply only SS coupling bearing.

16

-

-

... More
Supply only oil seal thrust bearing.

8

-

-

... More
Supply only Sand Guard.

8

-

-

... More
Dismantling pump and motor of submersible pump set for capacity 7.5 HP to 12.5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 200 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

8

-

-

... More
Supply only GM Bush.

8

-

-

... More
Supply only sleeve MS key for impeller

16

-

-

... More
Supply only SS coupling bearing.

16

-

-

... More
Supply only oil seal thrust bearing.

8

-

-

... More
Supply only Sand Guard.

8

-

-

... More
M&L for rewinding of monoblock Pump set motor of capacity 2 HP to 3 HP with same gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge

5

-

-

... More
M&L for rewinding of monoblock Pump set motor of capacity 4 HP to 5 HP with same gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge

4

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110

5

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45

4

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 25 to 32

8

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX upto 18.

6

-

-

... More
Material and labour for scrubbing out the rust deposited on the surface of centrifugal pump set including its base frame and preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint and marking SM /MES Number as directed. capacity of pump set 30 to 60 HP

6

-

-

... More
Material and labour for scrubbing out the rust deposited on the surface of centrifugal pump set including its base frame and preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint and marking SM /MES Number as directed. capacity of pump set 10 to 25 HP

16

-

-

... More
Supply and fix in replacement fully automatic star delta starter ML/MNX series with sheet metal enclosure suitable for 30 to 60 HP 3 phase 415 volts over load relay range 65-100 amps

3

-

-

... More
Supply and fix in replacement fully automatic star delta starter ML/MNX series with sheet metal enclosure suitable for 10- 25 HP 3 phase 415 volts over load relay range 45-65 amps

4

-

-

... More
Supply & fix Electronic overload relay (Manual reset) relay range 24-40 amp suitable for direct mounting

5

-

-

... More
Supply & fix Electronic overload relay (Manual reset) relay range 45-75amp suitable for direct mounting

4

-

-

... More
Supply & fix Electronic overload relay (Manual reset) relay range 66-110 amp suitable for direct mounting

4

-

-

... More
Supply & fix of monoblock pump single phase 2/3 HP capacity 240Volts, 50 Hz AC including fitting in given location with GI fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge.

3

-

-

... More
Supply & fix of Submersible pump horizontal single phase 2/3 HP capacity 240Volts, 50 Hz AC including fitting in given location with GI fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge.

3

-

-

... More
Supply & fix of Submersible pump single phase 5 HP capacity 240Volts, 50 Hz AC including fitting in given location with GI fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge.

2

-

-

... More
M & L for development of borewell by means of high capacity compressor, compressor capacity not less than 620 CFM at 8 Kg/cm square to its optimum yeild till clear water of potable quality free from sand/silt is obtained including draw down performnce and yeild test of the tubewells complete all as specified and directed by Engr- In- Charge.

4

-

-

... More
Servicing of submersible motor pump set of cap 5 HP to 12.5 HP including replacement of thrust plate and filling of distilled water and making it water tight complete all as specified and as directed by Engineer-in-charge

1

-

-

... More
Supply and fix in replacement Motor Guard( weather protection cover) made out of 22 gauge GI Sheet suitable for 2 to 5 HP centrifugal mono block pump set with lifting handle and provision of suction /dicharge pipeline Holes complete all as directed.

10

-

-

... More
M&L for GI clamps of 32mmx5mm complete with screw 50mm long x 6mm dia complete with drilling the hole with drilling machine with rawl plugs / wooden gutties for fixing / clamping the GI/PPR/UPVC pipes suitable for 50/40mm dia at a interval 01 mtr each complete by providing necessary scafolding upto the height of 15 mtrs complete all as specified and directed by Engineer-in-charge

45

-

-

... More
Supply & fix in replacement of MCCB 200 amps 4/3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply & fix in replacement of MCCB 100 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply & fix in replacement of MCCB160 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply & fix in replacement of MCCB 63 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
Supply & fix in replacement of MCCB 400 amps 4/3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement of MCCB 250 amps 4/3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Disconnecting & dismantling of pump set from the foundation breaking the existing defective PCC foundation in any size, shape M&L for PCC 1:2:4 type B-2 using 12.5 mm graded aggregate for foundation of any size of motor pump set from 20 HP to 60 HP capacity pump set and fitting pumping set in position with base frame painted with synthetic enamel black paint complete all as specified and as directed by Engineer-in-charge

5

-

-

... More
Supply & Fix in repair impeller of existing material suitable for 10 to 20 HP motor

5

-

-

... More
Supply & Fix in repair impeller of existing material suitable for 25 to 30 HP motor

3

-

-

... More
Supply & fix in repair impeller of existing material suitable for 40 to 60 HP motor

3

-

-

... More
S&F in replacement of DOL starter for 1 HP to 2 HP with relay 13-22 Amp complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement of DOL starter for 3 HP to 5 HP with relay 32-63 Amp complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
S&F in replacement of star delta starter SS enclosed inbuilt wiring with double door with ammeter voltmeter indication lamp mounted on enclosure with suitable contractor incomer MCB and relay timer for 3 HP to 5 HP with relay 63-120 Amp complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
Supply and fix in replacement electronic timer ET- 240/415 complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
Supply and fix in replacement amp meter digital type 0-100 amps complete all as specified and as directed

5

-

-

... More
Supply and fix in replacement volt meter 0-500 volts 96 sqmm digital type complete all as specified and as directed

5

-

-

... More
S&F in replacement of dial type FM-1 / QT daily timer one day 24 hrs 240 volt AC complete all as specified and as directed

4

-

-

... More
S&F in repair CT 30/5 to 200/5 complete all as specified and as directed

8

-

-

... More
S&F in repair indicating light with bulb set of three complete all as specified and as directed

20

-

-

... More
M&L for repair/maint of Sand Filter of semi automatic drinking water filtration system capcity 50000 lit per hourt, including replacing of sand & silex by opening top cover of sand filter tank and removing used sand and silex from Sand Filter Tank and washing/ cleaning the tank neatly & properly, and re- filling with new Fine Sand, Coarse Sand, Fine Silex and Coarse Silex in proper layers as per requirment and closing top cover of the Sand Filter Tank properly and check all connections complete all as directed by Engineer-in-Charge.

1

-

-

... More
M&L for repair/maint of Activated Carbon filter of semi automatic drinking water filtration system capcity 50000 lit per hour, including replacing of Carbon by opening top cover of Carbon filter tank and removing used old Carbon from Carbon filter tank and washing/ cleaning the tank neatly & properly ,and re- filling with new Activated Carbon as per requirment and closing top cover of the Carbon filter tank properly and check all connections complete all as directed by Engineer-in-Charge

1

-

-

... More
M & L in replacement of signboard made out of SS frame and size of 1.5 Mtr x 1 Mtr box type with fine quality PVC sheet writing letter minimum letter size is 10" and 30 ltrs placing in side board with proper securing and fixing one 20watt LED tube light with control wiring from switch point all as specified and directed by Engr-in-Charge

6

-

-

... More
S&F in repair PVC copper stranded conductor cable size 1.5 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

30

-

-

... More
S&F in repair PVC copper stranded conductor cable size 2.5 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

60

-

-

... More
S&F in repair PVC copper stranded conductor cable size 4 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

60

-

-

... More
S&F in repair PVC copper stranded conductor cable size 6 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

80

-

-

... More
S&F in repair PVC copper stranded conductor cable size 10 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

60

-

-

... More
S&F in repair PVC copper stranded conductor cable size 16 Sqmm multi stranded single core 1100 volt grade complete all as specified and as directed

50

-

-

... More
S&F in repair PVC flat sheathed submersible cable copper conductor of size 2.5 sqmm 3 core,1100 volt grade complete all as specified and as directed

60

-

-

... More
S&F in repair PVC flat sheathed submersible cable copper conductor of size 4.0 sqmm 3 core,1100 volt grade complete all as specified and as directed

80

-

-

... More
S&F in repair PVC flat sheathed submersible cable copper conductor of size 6.0 sqmm 3 core,1100 volt grade complete all as specified and as directed

80

-

-

... More
S&F in repair PVC flat sheathed submersible cable copper conductor of size 10.0 sqmm 3 core,1100 volt grade complete all as specified and as directed

60

-

-

... More
S & F Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" for 100mm bore with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating including taking down existing unserviceable pipe of any description and any size complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately.

120

-

-

... More
All as per Item No. 149 herein before but Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" for 150mm bore .

20

-

-

... More
All as per Item No. 149 herein before but Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" for 80 mm bore .

12

-

-

... More
S & F in repair DI fittings Bend,(any type ,radius and angle) tapers any type (straight, bend,increasing,decreasing or double socket etc), Tee pieces, connection pieces, collers, caps and plugs complete all as specified and directed

250

-

-

... More
Excavation in trenches not exe 1.5m wide and not exc 1.5 mtr depth for laying cable, pipes etc and getting out in hard/ dense soil complete all as specified and directed.

236.5

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed

147.37

-

-

... More
Removing excavated material to a distance not exc. 50m and depositing where directed at level not exc 1.5 m above complete all as specified and as directed.

62

-

-

... More
M&L Removing of accumulated earth over water supply mains of any width and depth up to 30 cm. including cleaning/cutting the grass and removing the grass waste to outside MD land complete all as specified and as directed. Note :- The unit rate quoted is deemed to be inclusive of following:- (a) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (b) Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled.

1500

-

-

... More
Attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, arrest Leakage in any rising main/ roof etc, applying necessary engineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed by Engineer-in-Charge.

250

-

-

... More
Note for item No 157 :- (a) The contractor has to attend above mentioned job in any location of entire domestic and tech area of Air Force Stn Sulur.

-

-

-

... More
(b) The service tanks are positioned on roof top of multi storied buildings upto four storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.

-

-

-

... More
(c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.

-

-

-

... More
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.

-

-

-

... More
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.

-

-

-

... More
(f) In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.

-

-

-

... More
(g) If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 1000/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
(j) The decision of the Accepting Officer in this regard shall be final and binding.

-

-

-

... More
Supply and fix in replacement of 90 mm outer diameter of pipes 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete all as specified and as directed

130

-

-

... More
(a) All as per Item No. 166 herein before but 3-layer PP-R pipe size of 63 mm outer dia

120

-

-

... More
(b) All as per Item No. 166 herein before but 3-layer PP-R pipe size of 50 mm outer dia

150

-

-

... More
(c) All as per Item No. 166 herein before but 3-layer PP-R pipe size of 32 to 40 mm outer dia.

130

-

-

... More
(d) All as per Item No. 166 herein before but 3-layer PP-R pipe size of 25 mm outer dia.

150

-

-

... More
(e) All as per Item No. 166 herein before but 3-layer PP-R pipe size of 20 mm outer dia.

200

-

-

... More
Note for item No 166 to 171:- (a) Cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately

-

-

-

... More
(b) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc

-

-

-

... More
(c ) Wall thickness of pipes shall be all as per IS : 15801

-

-

-

... More
S&F in replacement of 90 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.

3

-

-

... More
(a) All as per Item No. 175 herein before but gate valve size of 63 mm outer dia .

4

-

-

... More
(b) All as per Item No. 175 herein before but gate valve size of 50 mm outer dia .

5

-

-

... More
(c) All as per Item No. 175 herein before but gate valve size of 40 mm outer dia .

4

-

-

... More
(d) All as per Item No. 175 herein before but gate valve size of 32 mm outer dia .

6

-

-

... More
(e) All as per Item No. 175 herein before but gate valve size of 25 mm outer dia .

8

-

-

... More
Supply and lay in replacement of UPVC pipe class “SCH 40”, 100 mm mimum inner dia, conforming to IS 13592 with all fittings (specials) and fixtures including disconnecting and taking out old unserviceable pipe with fittings complete all as specified and directed. .

110

-

-

... More
(a) All as per Item No. 181 herein before but UPVC pipe size of 75 mm inner dia .

100

-

-

... More
(b) All as per Item No. 181 herein before but UPVC pipe size of 50 mm inner dia .

100

-

-

... More
(c) All as per Item No. 181 herein before but UPVC pipe size of 32 mm inner dia .

130

-

-

... More
(d) All as per Item No. 181 herein before but UPVC pipe size of 25/20 mm inner dia .

120

-

-

... More
Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each test point result to be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test less than (10 pits minimum and as considered 1 earthing point)

800

-

-

... More
Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each test point result to be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test (4 pits minimum and as considered 1 earthing point)

900

-

-

... More
Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each test point result to be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test less than (3 pitsminimum and as considered 1 earthing point)

1200

-

-

... More
Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each test point result to be submitted to Engineer-in-Charge duly signed by user and MES rep for Conventional type earthing (individual pit)

1500

-

-

... More
Note for item No 186 to 189 :- The following items are deemed to be inclusive of quoted rate :- (i) The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced, before commencement of work.

-

-

-

... More
(ii) The aforsesaid test will be carried out in presence of user and MES represnetative. (iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) will report every Morning at 9 AM to JE E/M for Daily earth testing.

-

-

-

... More
(iv) They will test Earth Resistance Every Day ( not more than 10 Nos earthing/day) in presence of user & MES rep and will record it in prescribed format , same will be put to Engineer-in-Charge,JE E/M duly signed by user & MES rep on very Next Day, failing which a Sum of Rs. 100.00 per Day will be recovered from the Contractor.

-

-

-

... More
(v) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab).

-

-

-

... More
(vi) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible).

-

-

-

... More
(vii) Checking of Earth Pits existing and improve it by watering / adding a layer of Salt/ Magnesium Sulphate/ Charcoal, etc.

-

-

-

... More
(viii) Contractor will be responsible for marking of Earth check date and due date on existing Plate with paint as specified by Engineer-in-Charge.

-

-

-

... More
(ix) Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.

-

-

-

... More
(x) EP No should be mentioned on individual earth pits and ER value of installation etc all as specified and directed by Engr In Charge.

-

-

-

... More
(xi) It will be the responsibility of the contractor to liase with Station authority to obtain security pass as per station rules for enetring/ working in high security tech area.

-

-

-

... More
Excavation in existing defective earth pit as notified by the Engr-in-Charge and spreading Common Salt, Charcoal dust and Magnesium sulfate & refilling the same and making good disturbed surface as like original position complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Note for Item No 200:- Common Salt, Charcoal dust and Magnesium sulfate shall be measured & paid seperately in relevant item of schedule. However labour element for spreading is deemed to be included.

-

-

-

... More
Supply only common salt commercial in trenches to improve the ER value of existing earth pits.

1900

-

-

... More
Supply only charcoal dust/Breeze each bags of 25 Kg in trenches to improve the ER value of existing earth pits (each bag 25 Kg).

80

-

-

... More
Note for item No 203:- Earthing charcoal dust/Breeze shall be supplied in packing as per originally packed by the manufacturer.

-

-

-

... More
Supply only Magnesium sulfate in trenches to improve the ER value of existing erath pits.

1600

-

-

... More
S & F Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc including taking down existing one complete all as specified and as directed

100

-

-

... More
NOTE for item No 206 :- Quoted Unit Rate deem to be included drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size.

-

-

-

... More
Supply only earthing chemical i.e. ground enhancing compound in bag of 25 Kg each complete all as specified and directed.

50

-

-

... More
Note for Item No 208 :- Material shall be delivered in the store yard of AGE E/M or as directed by AGE E/M and nothing extra shall be payable on this account.

-

-

-

... More
Repairing Damaged Earth Pit Cover Factory Made Earth Chamber in cement concrete 1:3:6 (20mm stone aggregate) as shown in Electrical Plate No. 03 of MES Schedule Part- I and providing Pre-cast RCC 1:2:4 (20mm graded stone aggregate) in Slab /Pit Cover 450x450x 50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways including Funnel and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistace and measuring and recording the same in presence of Engineer-in-Charge, complete all as specified and as directed.

50

-

-

... More
S & F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one complete all as specified and directed.

700

-

-

... More
NOTE for item No 211 :- All Joints should be joined by Exothermic Welding or Brazing.

-

-

-

... More
M & L for Brazing / exothermic welding arrangement for existing copper strip of size 32 x 6 mm / 20 x 3 mm thick complete all as specified and directed.

150

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.

15

-

-

... More
Note for Item No 214 :- (a) All Joints should be joined by Exothermic Welding or Brazing.

-

-

-

... More
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.

-

-

-

... More
(c) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab.

-

-

-

... More
(d) After testing if desired earth vesistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.

-

-

-

... More
(e) Rate shall include GI strip and protection pipe of length up to 7.5m

-

-

-

... More
S&F Galvanised earth strip of size 25 x 4mm fixed on proper post insulator at the instrument end including taking down existing strip complete all as specified and directed.

50

-

-

... More
M&L earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with Copper earth strip 20mmx3 mm thick and copper bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, ane provn of test point complete. NOTE : Copper strip 20x3mm upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately.

15

-

-

... More
Removing existing unserviceable earthing system and supply, installation, testing & commissioning of maintenance free chemical earthing system comprising duel pipes corrision protection with carbon coated 76mm outer with wall thickness of 1.6 mm and inner dia 42 mm with a wall thickness of 2.6 mm , overall length is 6000 mm.external corrosion protection : carbon coated (100 + microns) MS pipes alongwith 25 Kg (Conductolite), 25 Kg (Electrodite) and 10 Kg (Terraion) earth energizer compound. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab.

19

-

-

... More
Removing existing unserviceable earthing system and supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 8-10 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation incl EPCC- Poly plastic earthpit chamber. testing report shall be submitted after erretion.

14

-

-

... More
Note for chemical earthing :- The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.

-

-

-

... More
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.

-

-

-

... More
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.

-

-

-

... More
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).

-

-

-

... More
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.

-

-

-

... More
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.

-

-

-

... More
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.

-

-

-

... More
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including dry or rocky soil.

-

-

-

... More
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.

-

-

-

... More
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.

-

-

-

... More
(xiv) The electrode shall carry manufacturer's name .

-

-

-

... More
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.

-

-

-

... More
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.

-

-

-

... More
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.

-

-

-

... More
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.

-

-

-

... More
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.

-

-

-

... More
S & F Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed.

25

-

-

... More
Note for item No 243 :- The contractor shall submit load bearing capacity certificate from the manufacturer.

-

-

-

... More
S & F Factory Made RCC 1:2:4 (20mm graded stone aggregate) in Slab/Pit Cover 350x350x50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, complete including taking down existing one all as specified and as directed.

63

-

-

... More
S & F Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one complete all as specified and directed. Make/Model : Lexic MCB of MDS Legrand Cat No : 408584 to 408595 or equivalent. of Schnieder (Multi -9)/ Siemens/L&T (Hegar).

75

-

-

... More
Supply and fixing in repair LED flood light fitting 100 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor 0.95, Luminaire lumen output - 11000lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency 85%, THD10%, CRI70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. Make : Philips Cat No BVP192 LED 110 CW HO NB FG GR PSU or Equivalent of Havells/Wipro.

5

-

-

... More
Supply and fixing in repairs TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed

15

-

-

... More
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed.

150

-

-

... More
Note for item No 249 :- In case sufficient sand not obtained from excavation, additional qty of sand required to be obtain from out side MD land and the rate is deemed to be inclusive for the same

-

-

-

... More
S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.

6000

-

-

... More
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

150

-

-

... More
Note for item No 252:- Excavation and earth work shall be measured and paid seperately.

-

-

-

... More
S & F Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm.

10

-

-

... More
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge.

20

-

-

... More
Supply and fixing in repair LED flood light fitting 210 Watts 240 Volts, System wattage 195 W, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor 0.95, Luminaire lumen output - 23500lm, operating voltage range from 120V to 277V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency 85%, THD10%, CRI70%, Colour temperature 5700K to 6500K, Surge protection from overvoltages 5kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-160lm/w complete all as directed. Make : Philips Cat No BVP483 LED 235 CW AMB PSU GR or Equivalent of Havells/Wipro.

2

-

-

... More
S&F XLPE insulated, armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

300

-

-

... More
S&F XLPE insulated, armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

150

-

-

... More
S&F XLPE insulated, armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

200

-

-

... More
S&F XLPE insulated, armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

120

-

-

... More
Note for item No 257 to 260 :- Excavation and earth work shall be measured and paid seperately.

-

-

-

... More
Supply and fix in repair PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed.

100

-

-

... More
M&L Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size non metalic PVC Conduit and accessories complete fixed surface to wall/roof/ceiling etc and 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing submain wiring complete all as specified and directed.

150

-

-

... More
Note for item No 263:- Two runs of 1.5 sqmm power cable , one run of 1.5 sqmm earth conductor and one run of PVC conduit/casing capping will be measured as one length.

-

-

-

... More
Supply & fix LED tube rod; 4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light suitable for existing fitting.

600

-

-

... More
Supply & fix bell push complete all as specified and directed.

100

-

-

... More
Supply & fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.

150

-

-

... More
Supply & fix switch piano flush type 5 Amps 240 volts single pole two way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.

120

-

-

... More
All as per item No 267 here-in-before but 15 Amp Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.

90

-

-

... More
Supply & fix shuttered socket outlet 3 pin 5 amps, flush type

125

-

-

... More
Supply & fix shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps

120

-

-

... More
Supply & fix switch socket combination out let 3 pin 5 amps, flush type.

125

-

-

... More
Supply & fix switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type.

95

-

-

... More
Supply & fix for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked,

200

-

-

... More
Supply & fix lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.

68

-

-

... More
Supply & fix switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box

150

-

-

... More
Supply & fix switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box

120

-

-

... More
Supply and fix industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete all as specified and as directed.

30

-

-

... More
Supply & fix 9 watt LED lamp complete all as specified and directed.

100

-

-

... More
Supply & fix bell push, modular 1 way

50

-

-

... More
Supply & fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

100

-

-

... More
Supply & fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

150

-

-

... More
Supply & fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

89

-

-

... More
Supply & fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

80

-

-

... More
Supply & fix modular white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

70

-

-

... More
Supply & fix modular white cover plate with frame,4 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

50

-

-

... More
Supply & fix modular white cover plate with frame,6 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

50

-

-

... More
Supply & fix modular white cover plate with frame,8 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

50

-

-

... More
Supply & fix modular white cover plate with frame,12 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.

35

-

-

... More
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed.

100

-

-

... More
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed.

195

-

-

... More
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

150

-

-

... More
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

100

-

-

... More
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly including taking down existing point wiring complete all as specified and as directed.

-

-

-

... More
One light point/fan/bell point controlled by one switch

100

-

-

... More
All as per item No. 294 here in before but for one 3 pin socket out 5 amp on the same board

15

-

-

... More
All as per item No. 294 here in before but for one switch socket outlet 3 pin 5 Amps on independent board

30

-

-

... More
All as per Sl No 294 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently

28

-

-

... More
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

150

-

-

... More
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

150

-

-

... More
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 6 sqmm cable along with two runs of 6 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

135

-

-

... More
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 4 sqmm cable along with two runs of 4 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.

120

-

-

... More
Supply & fix in repairs plug top 3 pin 15 amps AC 230 volts complete all as specified and directed.

35

-

-

... More
Supply & fix in repairs plug top 3 pin 5 amps AC 230 volts complete all as specified and directed.

40

-

-

... More
Supply and fix in repairs metal clad switch socket triple pole and earth enclosure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB complete all as specified and as directed.

16

-

-

... More
Supply and fix in repairs indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips Cat part No.LHEXACP7IN1W00 or equivalent in Wipro/ Bajaj or equivalent approved make.

80

-

-

... More
Supply and Fixing in repairs indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips Cat part No.LHEXBLP7IN1W020 or equivalent in Wipro/ Bajaj or equivalent approved make.

120

-

-

... More
S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of 100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI 80, Color temperature5700±300K, THD 10% and PF 0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro or equivalent approved make.

14

-

-

... More
S&F PVC insulated, heavy duty electric service cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sq. mm 2 core fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

95

-

-

... More
S&F PVC insulated, heavy duty electric service cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

80

-

-

... More
S&F PVC insulated, heavy duty electric service cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

90

-

-

... More
S&F PVC insulated, heavy duty electric service cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.