Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 49,50,000 
Notes
Download

Costs

Summary

Repair / Maint Of Power Distribution System Central Sub-station, C Sub-station, B Sub-station, E Sub-station, Sre And Bcr Sub-stations And Connected Items In Technical Area

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(ii) Cable joint will be measured and paid separately.

-

-

-

... More
(iii) Additional length of cable required at site for jointing will be measured and paid separately

-

-

-

... More
S&F MCCB, 3 Pole, 250 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 36 KA including connecting up using suitable size of copper lugs including taking down existing one complete all as specified and as directed.

1

-

-

... More
S&F MCCB, 4 Pole,400 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 50 KA including connecting up using suitable size of copper lugs including taking down existing one complete all as specified and as directed.

1

-

-

... More
Supply and installation of Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6 mm (upto 7.50mm length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore medium grade including necessary Excavation in any type of soil, Returning, Filling and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as specified and as directed.

4

-

-

... More
Note for Item No 8:- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.

-

-

-

... More
M & L PCC (1:2:4) type B-1 150 mm thick using 20 mm graded stone aggregates and finishing cement concrete surface even and smooth with out using extra cement as in platform/foundation all as specified and as directed complete all as specified.

3

-

-

... More
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil all as specified. Note : Only manual excavation will be allowed inside technical area.

198

-

-

... More
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.

110

-

-

... More
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.

88

-

-

... More
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed.

68

-

-

... More
Note for Item No 14 :- In case sufficient sand not obtained from excavation, the required additional qty shall be obtained from out side MD land as directed by the Engineer-in-Charge and the rate is deemed to be included the above provision also.

-

-

-

... More
S&F Fly ash bricks cable protection cover including taking down existing bricks of any size complete all as specified and as directed.

1400

-

-

... More
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 300 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.

70

-

-

... More
M & L Cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with PCC 1:2:4 type B1 using 20mm graded stone aggregate thickness of concrete is 150mm complete all as specified and directed.

12

-

-

... More
Note for item No 18:- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-

-

-

-

... More
(i) Earth work excavation in any type of soil

-

-

-

... More
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.

-

-

-

... More
(iii) Removing excavated material to out side MD land

-

-

-

... More
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately

-

-

-

... More
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road

-

-

-

... More
Supply and fix in repairs Galvanised Earth Strip of size 32x6 mm as earthing lead fixed to wall/roofs etc complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.

45

-

-

... More
Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size complete all as specified and as directed.

160

-

-

... More
Note for item No 26 :- (i) The above work also include checking, detection and rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M).

-

-

-

... More
(ii) Hiring of cable fault detector to detect exact location of LT/HT UG cable fault deemed to be inclusive of quoted rate.

-

-

-

... More
(iii) Major items required to be replaced/repaired will be measured under relevant items of schedule.

-

-

-

... More
(iv) Excavation and earth work if required will be measured separately

-

-

-

... More
(v) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days).

-

-

-

... More
(vi) In case of minor defect, entire job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300/- per hours shall be recovered.

-

-

-

... More
(vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.

-

-

-

... More
(viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 500/- per hours shall be deducted from the dues of the contractor.

-

-

-

... More
(ix) Note that penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding.

-

-

-

... More
(x) Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon and after noon to collect routine/urgent works till completion of work.

-

-

-

... More
Supply only GI pipe 100 mm bore medium grade for cable protection complete all as specified and as directed by Engr-in-Charge. Note :- The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in any type of road road will be measured and paid separately.

12

-

-

... More
M & L Boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe "heavy duty" of size 100mm bore fixed in repairs complete all as specified and directed

20

-

-

... More
M & L for Repairing, overhauling, Servicing & testing of Vaccum circuit breaker 11 KV, 630 A to 800 Amps, 250 MVA, 66 KA Peak, 3 Phase, 50 Hz, AC Supply system, indoor type for trouble free operation, and VCBs are for incoming , Bus coupler & Bus riser and Outgoings ,metal clad totally enclosed free standing floor mounted type,and vaccum circuit breakers, draw out type HT VCBs including the following works complete all as specified and directed:-

6

-

-

... More
Note for item No 39 :- (a) The rate for following shall be deemed to be included in quoted rate.

-

-

-

... More
(b) The entire job shall be carried out through the authorised service engineers of the OEM only in the presence of Engineer-in-Charge/JE E/M.

-

-

-

... More
(c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.

-

-

-

... More
(d) Servicing of 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system.

-

-

-

... More
(e) Servicing of Breaker with motor charging assembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels.

-

-

-

... More
(f) Servicing of Mech (caster lock) and elect inter locking system.

-

-

-

... More
(g) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(h) Replacement of PT Fuse

-

-

-

... More
(j) Replacement of unserviceable spare parts will be measured and paid for separately as supply only.

-

-

-

... More
(k) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.

-

-

-

... More
(l) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.

-

-

-

... More
Supply only Digital Microprocessor based Feeder protection Relay Model REF 651 for Over current and Earth fault including necessary necessary control wiring all as directed.

1

-

-

... More
Supply only Electrical closing coil 110 volt DC operated, suitable for item No 39 complete all as specified and directed.

1

-

-

... More
Supply only Electrical shunt trip coil 110 volt DC operated, suitable for item No 39 complete all as directed.

1

-

-

... More
Supply only 11 KV single phase in door resin cast CT of ratio 150/100/5A class 1.0/ 5P10,burden 15VA – 15 VA , suitable for item No 39 complete all as directed.

1

-

-

... More
Supply only Vaccum Interrupter (Vacum Bottle ) suitable for item No 39 complete all as directed.

2

-

-

... More
Disconnecting in coming HT and out going LT cable connections and taking down Transformer of any type/size/make/capacity from 2/4 Pole structure or from floor/pedestal and shifting to new location with in 3 KM and install where directed, refixing HT/LT cable connections complete all as directed.(Any damages happened to transformer during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt).

2

-

-

... More
M & L Removing of acumulated earth of any width and depth up to 30 cm. cleaning/cutting the grass around two/ four pole structure, transformer yard,sub stn,generator rooms etc and removing the grass waste to outside MD land complete all as specified and as directed.

2000

-

-

... More
Note for Item No 57 :- The unit rate is deemed to be included for the following :- (a) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.

-

-

-

... More
(b) Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shalll be carefully filled up with moorum/red bajri well rammed and levelled.

-

-

-

... More
Supply and fixing HT tape roll 35mm width Appx 5 mtr length.

3

-

-

... More
Removing HT cable, 11 KV, XLPE 185 Sqmm 3 core with aluminium conductor, shifting to other location (not exc 2 KM distance) and relaying same cable in trenches/through pipes or bare in road crossings/ paths/drains/ducts/ floors /along poles/walls/ ceilings/ equipments etc all as directed.

300

-

-

... More
Note for Item No 61 :- The unit rate is deemed to be included for :- (a) Excavation for taking down existing cable, shifting of cable as directed by the Engineer-in-Charge and relaying cable including required excavation as specified in SSR Part-I.(b) Disposal and return filling.

-

-

-

... More
(b) Sand cushioning and cable protection shall be measured and paid separatley under relevant item.

-

-

-

... More
Supply only Electrical Rubber hand gloves as per ISI specification for operating voltage 11 KV complete all as specified and as directed.

2

-

-

... More
Supply and lay graded stone aggregate of 40mm size, spread and leveled around 4 pole/ 2 pole structure, transformer, sub stn, panel board yard completed all as specified and as directed.

6

-

-

... More
Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade, of cross sectional area 185 Sqmm x 3 core laid including taking down existing cable from trenches/ duct or any position all as specified and directed.

260

-

-

... More
M&L in repairs Un-reinforced precast concrete cable cover class HV Type 1, flat size 300mm x 180 mm x 40 mm thick complete all as specified and as directed.

3700

-

-

... More
Supply and fix in repairs Cable route indicators for HT cable with CI plate and angle iron 25x25x6mm showing MES,HT/LT cable,and voltage including excavation earth work and PCC complete complete all as specified and as directed.

18

-

-

... More
M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 185Sqmm to 300Sqmm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge .

35

-

-

... More
M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 70 Sqmm to 95 Sqmm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge .

40

-

-

... More
Note for Item No. 69 & 70 :- (i) The insulation resistance shall be tested between the conductors.

-

-

-

... More
(ii) The insulation resistance shall be tested between the conductor and armoured/ earth.

-

-

-

... More
(iii) The contractor shall arrange necessary testing instruments of suitable range and cost for the same shall deem to be included in the quoted unit rate.

-

-

-

... More
(iv) Test to be conducted in the presence of MES rep and concerned user and will record it in prescribed format. Test records duly signed by all to be submitted by the contrator to the Engineer-in-charge while claiming for payment.

-

-

-

... More
(v) In case, any damages found at end termination of the cable, same shall be rectified by using suitable size of lugs / nuts & bolts for the reconnection of cable in transformer/ LT Panel/ DBs. cost for the same shall deem to be included in the quoted unit rate.

-

-

-

... More
(vi) Cost of earth work required for disconnecting and reconnecting the cable shall deem to be included in the quoted rate.

-

-

-

... More
(vii) The quoted unit rate deemed to be included for disconnecting the cable from the transformer/ LT panel/DBs and reconnecting the same after the insulation resistance test.

-

-

-

... More
M&L Out door cable straight through jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (Earthed) grade, of cross sectional area 185 Sqmm 3 core complete all as specified and as directed.

9

-

-

... More
Note for Item No 78 :- (i) Locating of HT UG Cable fault and taking out the existing faulty HT cable carefully from the trench after excavation and cutting faulty portion and re- laying the same cable after jointing with out any damage and the cost for this provision is deemed to be included in the item rate quoted .

-

-

-

... More
(ii) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days ).

-

-

-

... More
(iii) The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs

-

-

-

... More
(iv) Penalty of Rs 2000.00 per Job shall be applicable to the contractor if the complaint is not attended with in half an hrs. Note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforced above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
(v) The decision of the Accepting Officer in this regards shall be final and binding.

-

-

-

... More
(vi) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.

-

-

-

... More
Supply only cottan / Baniyan waste

3

-

-

... More
Disconnecting in coming and out going HT / LT cable connections and taking down HT / LT RCC /Steel Tubular pole unserviceable/ isolated one at different places all as specified and as directed. Note: cost including tools and plants for cutting of existing pole shall be deemed to be included in the unit rate quoted.

6

-

-

... More
Repairing, overhauling, Servicing & testing of RMUs of make ABB, 11 KV, 20 KA, 3 Phase, 50 Hz, AC Supply system, outdoor type for trouble free operation, consisting of one/two incomming and one/two outgoing with SF6 gas filled VCB/ LBS/Fuse units, metal clad totally enclosed free standing floor mounted, non draw out type including the following works complete all as specified and directed.

4

-

-

... More
Note for item No 87 :- The Work shall be carried out through the authorised service engineers of the OEM only (a) Servicing of Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism along with associated earthing switch (ii) Servicing of true position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel for proper indication (b) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
Disconnecting incoming/outgoing cable connections of the existing VCB and taking down complete with all accessories from the foundation and shifting same to the out door location with in the distance of 2 KM and re-install, testing and commissioning of VCB including cable connections , complete all as specified and directed. (Any damages happened in VCB during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt).

2

-

-

... More
Repair/Replacement of stand alone HT Panel, 11 KV, 3 phase, 50Hz, 630A, 25 KA for 1 sec factory made, out door type cubicale fabricated out of CRCA sheet 3mm thick weather, dust and vermin proof, epoxy powder coated of IP-55 protection class with self contained air insulated compartment for bus bars and cable boxes with necessary support and 630A rated aluminium bus bar including cable galleries and provision of following switch gears including earthing switch, all pre-wiring with PVC copper conductor cable of suitable size including taking down of the unserviceable panel all as specified and as directed as per the below details :-

1

-

-

... More
(a) Manually operated air break, load break switch alongwith earth switch and fuse trip mechanisum of HT HRC fuse - 50A, 230 V AC, Trip Coil and Aux Contact 2 No + 2NC.

-

-

-

... More
(b) Space heater with ON/ OFF switch 10A, 230V AC.

-

-

-

... More
(c) Emergency trip push botton - 01

-

-

-

... More
(d) Cubicale illunination lamp with holder - 01

-

-

-

... More
(e) Door limit switch, 230V AC.

-

-

-

... More
(f) Provn of MCB, DP, 10A for control wiring.

-

-

-

... More
(g) Provn of surge arrester 9 KV, 10 KA.

-

-

-

... More
(h) Provn of thermostat

-

-

-

... More
(j) Provn of indication lamp for LBS ON/ OFF, LBS E/S ON/ OFF 230V AC. Make of LBS shall be as mentioned in list of makes Megawin

-

-

-

... More
M&L for Chequred rubber mat of 1100 Volts grade of size 2.0x 0.9m and thickness 12mm with ISI marked Complete all as Specified and as directed by Engineer-in-charge.

4

-

-

... More
Repair to transformer after disconnecting incoming HT connection and out going LT cable connection, draining out the transformer oil and keep in safe custody for reuse, disconnecting the breather assembly, temperature gauge, taking out the top cover of transformer 400 KVA, outdoor type, 11KV/433 Volt, step down, disconnecting LT/HT winding connections from LT/HT Bushing and carefully taking out LT/HT Bushing insulator and HT/LT Brass spindle, taking out gaskets of LT/HT Bushings and transformer top cover. Refixing exisiting LT/HT Brass spindle with Bushing insulators after replacing Gaskets, View glass of conservator tank, refixing all cable connections, top cover with new gasket, breather/temp gauge, refilling transformer oil, complete all as specified and as directed.

1

-

-

... More
Note for item No 101 : (i) Transformer oil for topup, dehydration/filtration etc will be measured and paid separately.

-

-

-

... More
(ii) Complaints regarding Transformer will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days).

-

-

-

... More
(iii) The contractor shall attend the complaint immediately. and shall report the Engr-in-Charge/JE( E/M) after completion.

-

-

-

... More
(iv) Penalty of Rs 5000.00 per Job shall be applicable to the contractor if the complaint is not attended immediately. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
(v) The decision of the Accepting Officer in this regards shall be final and binding.

-

-

-

... More
(vi) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC and the same complaint shall be completed with in the period decided by the GE/EIC.The penalty of Rs 5000/ per Job shall also be applicable to the contractor for non-completion of complaint with in the time decided by the GE/EIC.

-

-

-

... More
(vii) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof including tools and plants shall be deemed to be included in the unit rate quoted for this item.

-

-

-

... More
(viii) Transformer oil shall be drained out by the contractor in suitable capacity mild steel drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be included in unit rate quoted against the respective item of this schedule.

-

-

-

... More
(ix) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011 at site in the presence of E-in- Charge/ JE and the cost of testing shall be deemed to be included in unit rate quoted against this item.

-

-

-

... More
(x) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded.

-

-

-

... More
All as per item No. 101 above but of capacity of transformer 160 KVA to 250 KVA.

1

-

-

... More
All as per item No.101 above but of capacity of transformer upto 100 KVA.

1

-

-

... More
Supply and fixing LT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of capacity upto 250 KVA including taking down u/s from the transformer complete all as specified and as directed

4

-

-

... More
Supply and fixing LT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of above 250 KVA upto 500 KVA including taking down u/s from the transformer complete all as specified and as directed

4

-

-

... More
Supply and fixing Breather assembly suitable for outdoor type transformer with silica Gel including taking down u/s from the transformer complete all as specified and as directed

4

-

-

... More
Supply & filling silica gel inside breather assembly of trasformer complete all as specified and as directed

5

-

-

... More
Dehydration/Filteration of HV grade Transformer oil of transformer/switch gears minimum three cycles to achieve dielectric strength not less than 40 KV for 1 minute with 2.5 mm Gap as per IS 335-1983 for HV grade including topping up with new transformer oil complete all as specified and as directed

2400

-

-

... More
Note for Item No 118:- (i) Centrifuging Machine with all T & P and testing machine of oil, required for dehydration shall be arranged by contractor

-

-

-

... More
(ii) Oil required for topping up the transformer will be measured & paid separately.

-

-

-

... More
Supply and replacement or topping up of transformer Oil HV as per IS 335 of 1983 Part II after dehydration & testing and dielectric strength not less than 40 KV complete all as spceified and directed. Note :- The transformer oil shall be supplied in sealed barrel and shall confirm to IS -335 (including all amendments upto date)

450

-

-

... More
Supply and Fix of HT, 11 KV grade, barrel fuse of capacity upto 40 Amps suitable for HT Switch fuse unit of Make ABB including taking down existing one complete all as specified and as directed.

3

-

-

... More
Supply and Fix of HT, 11 KV grade, barrel fuse of capacity upto 50 Amps suitable for HT LBS of Make Megawin including taking down existing one complete all as specified and as directed.

3

-

-

... More
Dismantling existing old unservicable/burnt air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism complete all as directed by the Engr-in-Charge.

1

-

-

... More
Supply and fix in repairs Switch air break, gang operated, out door type, triple pole, HT 11000 volts, 400 Amps, vertical type with 3 insulators mounted with fixed contacts of phospor bronze and moving contacts of copper, mechanically operated from ground level with operating mechanism complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Supply and fix in repairs Drop out expulsion fuse assembly with fuse carrier, triple pole HT 11000 Volts, 200 Amps, out door type (having two Nos post insulators mounted on MS Channel for each pole ) all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Supply and Fix of Lightening arrestors Expulsion type complete with all fitting, transmission class, discharge capacity 10 kilo Amps suitable for 11000 Volts and connecting to earth wire complete all as directed including taking down the u/s bursted lightning arrestors from Load break switch complete all as specified and as directed.

3

-

-

... More
M&L for isolating, cutting, removing the existing damaged straight through heat shrink type joint and Supply and Replacement of Cable jointing kit for 1.1 KV grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 185 sqmm to 300 sqmm.

5

-

-

... More
M&L Out door cable end jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area 185 Sqmm 3 core complete all as specified and directed . Note:- Taking out of existing cable, from VCBs, RMUs or Two Pole structures and cutting faulty ends if required and re- fixing the same with out any damage of switch Gears are deemed to be included in the item rate quoted) (ii) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days ). (iii) The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs (iv) Penalty of Rs 2000.00 per Job shall be applicable to the contractor if the complaint is not attended with in half an hrs. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. (v) The decision of the Accepting Officer in this regards shall be final and binding. (vi) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.

8

-

-

... More
Repairing, overhauling, Servicing & testing of Air circuit breaker, 440V, 630 Amps to 1600 Amps, 50 KA, 3 Phase, 50 Hz, AC Supply system,for trouble free operation,and draw out type Air Ciruit breaker including the following works complete all as specified and directed:- Makes of ACB :- C&S, Schneider, Siemens. Location - MAFI PS 1, Sub Stn 'B' & 'D', Mehra Sub Stn, Simulator bldg, Avionic Eqpt bldg, EW block, ETB bldg, Electric logistic block, IFCS section, Mech CENGO section, Near LCA Hanger

5

-

-

... More
Note for item No 130 :- (a) The rate for following shall be deemed to be included in quoted rate.

-

-

-

... More
(b) The entire job shall be carried out through the authorised service engineers of the OEM only.

-

-

-

... More
(c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.

-

-

-

... More
(d) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the ACB trolly from the panels.

-

-

-

... More
(e) Servicing of Mech and elect inter locking system.

-

-

-

... More
(f) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(g) Servicing of Mech (caster lock) and elect inter locking system.

-

-

-

... More
(h) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(j) Replacement of PT Fuse

-

-

-

... More
(k) Replacement of unserviceable spare parts will be measured and paid for separately.

-

-

-

... More
(l) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate.

-

-

-

... More
(m) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.

-

-

-

... More
Supply only spring charging assembly including motor 230 V AC operated, suitable for Item No 130 all as directed.

2

-

-

... More
Supply only Electrical closing coil 230 volt AC operated, suitable for Item No 130 all as directed.

3

-

-

... More
Supply only Electrical shunt trip coil 230 volt AC operated, suitable for Item No 130 all as directed.

3

-

-

... More
Supply, install, testing and commissioning of Solar PV Panel 325 WP Module Cat Part No : HST72F325M of Make : HHV Solar or equivalent in approved make, including removal of existing unserviceable one complete all as specified and as directed. Note : (i) Output power -Pmax(Watt peak)-325 Wp or above (ii) Modules should have efficiency of not less than 15% and the fill factor should be above75% (iii) Type of solar PV cell-mono crystalline sillicon (iv) Suitability - For grid connected system (v) Module output : MC electronics plug (Male and Female) (vi) Certification - The PV module must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval as per IEC61215/BIS14286

9

-

-

... More
Repairing, overhauling, servicing and testing of compact secondary substation non-walk in type 11 KV/ 433V, 500 KVA consisting of following components :-

2

-

-

... More
(i) Compact type HT switch gears (type-VVV) of three Nos VCBs, 11KV, 630Amp, 21KA (two incoming and one outgoing) with SF6 gas insulated and over current, short circuit current and earth fault protection release.

-

-

-

... More
(ii) Oil type transformer copper wound, 500 KVA, 11KV/ 433V Dyn11 - 01 No.

-

-

-

... More
(iii) LT panel 433V with aluminium bus bar of 1000 Amps, LT Air Circuit Breaker 800 Amps, 4 Pole , 50Hz, 50KA with microprocessor based release for over current, short circuit current and earth fault protection – 02 Nos (Two incoming ) & MCCBs for outgoings Location : Electric Logistic Block, ETB Buldg Make of CSS – Siemens

-

-

-

... More
Note for item No 147 to 150 : (a) The rate for following shall be deemed to be included in quoted rate.

-

-

-

... More
(b) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.

-

-

-

... More
(c) Servicing of 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system.

-

-

-

... More
(d) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels.

-

-

-

... More
(e) Servicing of Mech (caster lock) and elect inter locking system.

-

-

-

... More
(f) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(g) Replacement of PT Fuse

-

-

-

... More
(h) Replacement of unserviceable spare parts will be measured and paid for separately.

-

-

-

... More
(j) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate.

-

-

-

... More
(k) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.

-

-

-

... More
Supply only Electrical closing coil 110 volt DC operated, suitable for Item No 147 complete all as directed.

2

-

-

... More
Supply only Electrical shunt trip coil 110 volt DC operated, suitable for Item No 147 complete all as directed.

2

-

-

... More
Supply only 11 KV single phase in door resin cast CT of ratio 150/100/5A class 1.0/ 5P10,burden 15VA – 15 VA, suitable for Item No 147 complete all as directed.

1

-

-

... More
Supply only Vaccum Interrupter (Vacum Bottle ) suitable for Item No 147 complete all as directed.

2

-

-

... More
M&L for preparation of old painted steel surfaces of 2 pole structure including brackets, clamps, channels and cross arms by cleaning of oils, lubricants, grease etc. complete above PCC coping and applying two coats of aluminium paint on surfaces 1m above PCC coping, applying two coats of synthetic enamel paint in zebra pattern with black & yellow colour combination up to 1m height above PCC coping; writing MES No. of poles (Number size shall be 25mm and lettering shall be 40mm) complete including applying two coats of white wash on exposed concrete surfaces of coping to poles duly preparing the surfaces all as directed by Engineer-in-Charge.

2

-

-

... More
M&L for preparation of old decorated surfaces of walls of transformer plinth and applying one coat of cement based paint all as specified.

45

-

-

... More
Material and caliberation of existing 4 pole Micro processor based digital programmer Protection relay unit having over current handling capacity up to 10 Amps for 10 milli sec and Earth fault arrest less than 04 mili sec to arrest the fault individual breaker at site.

3

-

-

... More
M&L Danger notice plate/caution sign board made out by 1.6mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT network in size 25x20 CM including taking down existing one complete all as specified and directed. (Note- Given caution shall be written in two language i.e Tamil and English and quoted rate shall be deemed included cost of letter writing & conventional skull & bones figure).

10

-

-

... More
Dismantling/taking down of insulators of any type/size from HT/LT poles/DOs/GODs complete all as directed by Engr-in-Charge.

11

-

-

... More
S&F Post type, HT 11 KV insulators suitable for GO/DO switch, duly tested and including making connections with proper size of thimbles complete all as specified and directed.

3

-

-

... More
Supply and Fix Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified.

3

-

-

... More
Supply and Fix Disc type insulator, porcelain, vitreous, 145 mm high and 255mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified.

5

-

-

... More
Servicing the existing Drop out fuse assembly, of capacity 200 Amps, 11 KV, 3 Pole, including replacing worn out/ rusted nuts, bolts, clamps, washers, etc. and providing coloured sleeves for jumper connections complete all as specified and as directed.

3

-

-

... More
Taking out and repairing / overhauling of air break gang operated switch 200 Amp, 11 KV capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally, replacement of broken/ worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly on contacts re-fixed the same after repair complete including new nut bolts and washer etc all as specified and directed. (Note : The quoted rate by contractor shall include the serviceable parts in position and replacement of U/S parts with new one.

1

-

-

... More
Supply only tinned copper fuse wire of 18 SWG to 38 SWG (approx) in roll of 100/200/ 250 grms

4

-

-

... More
Supply only Gum Boot of size 8 / 9 all as directed

2

-

-

... More
Repairing, overhauling, servicing and testing of compact secondary substation non-walk in type 11 KV/ 433V, 400 KVA consisting of following components :-

2

-

-

... More
(i) Compact type HT switch gears (type-VVV) of three Nos VCBs, 11KV, 630Amp, 21KA (two incoming and one outgoing) with SF6 gas insulated and over current, short circuit current and earth fault protection release.

-

-

-

... More
(ii) Oil type transformer copper wound, 400 KVA, 11KV/ 433V Dyn11 - 01 No.

-

-

-

... More
(iii) LT panel 433V with aluminium bus bar of 1000 Amps, LT Air Circuit Breaker 800 Amps, 4 Pole , 50Hz, 50KA with microprocessor based release for over current, short circuit current and earth fault protection – 02 Nos (Two incoming ) & MCCBs for outgoings Location : Electric Logistic Block, ETB Building Make of CSS – Siemens

-

-

-

... More
Note for item No 177 to 180 : (a) The rate for following shall be deemed to be included in quoted rate.

-

-

-

... More
(b) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.

-

-

-

... More
(c) Servicing of 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system.

-

-

-

... More
(d) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels.

-

-

-

... More
(e) Servicing of Mech (caster lock) and elect inter locking system.

-

-

-

... More
(f) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(g) Replacement of PT Fuse

-

-

-

... More
(h) Replacement of unserviceable spare parts will be measured and paid for separately.

-

-

-

... More
(j) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate.

-

-

-

... More
(k) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate.

-

-

-

... More
Supply only Electrical closing coil 110 volt DC operated, suitable for Item No 177 complete all as directed.

1

-

-

... More
Supply only Electrical shunt trip coil 110 volt DC operated, suitable for Item No 177 complete all as directed.

1

-

-

... More
Supply only 11 KV single phase in door resin cast CT of ratio 150/100/5A class 1.0/ 5P10,burden 15VA – 15 VA, suitable for Item No 177 complete all as directed.

1

-

-

... More
Supply only Vaccum Interrupter (Vacum Bottle ) suitable for Item No 177 all as directed.

1

-

-

... More
S & F in repairs 6 sqmm single core, 1.8 KV DC Solar copper cable including necessary connectors and drawn through PVC conduit pipes of suitable size complete all as specified and directed.

1010

-

-

... More
S & F in repairs 0.75 sqmm 2 core, 1.1 KV AC copper cable including necessary connectors and drawn through PVC conduit pipes of suitable size complete all as specified and directed.

389

-

-

... More
S & F in repairs Solar drive AC to DC device input AC voltage 240 V DC output 24 V Model No LRS-100-24 complete all as specified and directed.

8

-

-

... More
S & F in repairs DC cable adopter Male & Female complete all as specified and directed.

45

-

-

... More
S & F in repairs Air filter suitable for 1 MW Solar plant PVS800-57-1MW+12H382+K466+Q976+P902 complete all as specified and directed. Cat pt no 3AYN1871038-HAB of ABB or equivalent in approved make

2

-

-

... More
S & F in repairs Switch Mode Power Supply suitable for 1 MW Solar plant with following parameters complete all as specified and directed. MCS-B 10-110-240/24 Single Phase art No 857893 INPUT : l/N/PE 110 -240V 50/60 HZ 4.0 A OUT PUT :24VDC ,10A

3

-

-

... More
S & F in repairs UPS Dry type Batteries12V, 26 AH complete all as specified and directed.

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.