Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date11 Jan 2025
Closing Date25 Jan 2025
Tender Amount₹ 29,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for providing sand cushioning for protection of UG cable in trenches with coarse Riddled Earth of approved quality as approved in writing by GE including filling, spreading and punning down to desired thickness complete and all as specified and directed by Engr-in-Charge.

150

-

-

... More
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed.

15865

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cable laid in trenches or passing through GI and connecting accessories incl taking down old cable complete all as specified & as directed. of size 6 sq mm 2.0 core Note :- Necessary earthwotk, PCC etc shall be measured & Paid separately under relevant items of works.

500

-

-

... More
All as per Item Sl No 6 here in above but of size 10 Sqmm 4.0 core.

300

-

-

... More
All as per Item Sl No 6 here in above but of size 16 Sqmm 4.0 core.

400

-

-

... More
All as per Item Sl No 6 here in above but of size 25 Sqmm 4.0 core.

250

-

-

... More
All as per Item Sl No 6 here in above but of size 35 Sqmm 3.5 core.

200

-

-

... More
All as per Item Sl No 6 here in above but of size 50 Sqmm 3.5 core.

100

-

-

... More
All as per Item Sl No 6 here in above but of size 70 Sqmm 3.5 core.

120

-

-

... More
All as per Item Sl No 6 here in above but of size 95 Sqmm 3.5 core.

250

-

-

... More
All as per Item Sl No 6 here in above but of size 120 Sqmm 3.5 core.

180

-

-

... More
All as per Item Sl No 6 here in above but of size 150 Sqmm 3.5 core.

200

-

-

... More
All as per Item Sl No 6 here in above but of size 185 Sqmm 3.5 core.

120

-

-

... More
Description all as per Item Sl No 6 here in above but of size 240 Sqmm 3.5 core.

200

-

-

... More
M&L for cutting the existing hardstanding/PCC / road at a depth of not less than 60 cm & 30 cm in width for passing of LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.

30

-

-

... More
M&L for cutting grass, bushes, creapers, weeds, unwanted plants/growths, area cleaning etc in and arround Supply Installations, any other locations as directed by Engr-In-Charge and removing rubbish off the premises complete all as specified.

3000

-

-

... More
NOTE for Item Nos 1, 7 & 8 : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the excavation/boring/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge, the cost of the same is deemed to be included in the unit quoted rates.

-

-

-

... More
Supply and laying GI pipe light grade (ISI Marked) of size 100 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as directed and specified by Engr-in-Charge.

80

-

-

... More
Supply and laying GI pipe light grade (ISI Marked) of size 80 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as directed and specified by Engr-in-Charge.

60

-

-

... More
Supply and laying GI pipe light grade (ISI Marked) of size 50 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as directed and specified by Engr-in-Charge.

80

-

-

... More
M&L for preparation of old painted steel surfaces of outdoor/indoor type LT/HT Panels of any size/type etc. after cleaning of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. complete & applying one coat of synthetic enamel paint of approved colour & grade using spray gun & neatly writing distribution details (if applicable) all as per directed.

50

-

-

... More
M&L for preparation of old painted steel surfaces of LT/HT/Security/Street light steel tubular poles and structure incl MS Clamps, cross arms, GI Pipe brackets etc. of any size/type etc. after cleaning/removal of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. & applying one coat of Aluminium paint & neatly writing pole numbers incl triming of tree branches near pole complete all as specified & as directed by the Engr-In-Charge.

50

-

-

... More
M&L for straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable, incl earthwork, taking down, preparation of damaged cable incl testing complete all as specified and directed of size 25 to 50 Sqmm 4/3.5 core

10

-

-

... More
All as per Item Sl No 14 here in above but suitable for Aluminium conductor cable of size 70 to 120 Sqmm 3.5 core.

10

-

-

... More
All as per Item Sl No 14 here in above but suitable for Aluminium conductor cable of size 150 to 185 Sqmm 3.5 core.

6

-

-

... More
All as per Item Sl No 14 here in above but suitable for Aluminium conductor cable of size 240 to 300 Sqmm 3.5 core.

4

-

-

... More
S&F in repairs aluminium cable lugs for the following sizes after removing the old /burnt out cable lugs of cable from MCCBs/Changeover/Transformer LT bushing and connecting back cables in MCCBs/Changeover/Transformer LT bushing for 16 sqmm to 25 sq mm complete all as specified and as directed.

25

-

-

... More
Description all as per Item Sl No 18 here in above but 35 Sqmm to 50 Sqmm complete allas specified and as directed.

20

-

-

... More
Description all as per Item Sl No 18 here in above but 70 Sqmm to 95 Sqmm complete allas specified and as directed.

20

-

-

... More
Description all as per Item Sl No 18 here in above but 120Sqmm to 185 Sqmm complete allas specified and as directed.

20

-

-

... More
S&F in repair 4 pole Power Contactors aux contacts (2 No + 2 NC) Rating Fr 4 setting and making cut in existing panel complete all as specified and directed by the Engr-in-Charge

2

-

-

... More
S&F in repair , 4 pole,63A rating (Ics = 100% Icu),415Volts,16 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

3

-

-

... More
S&F in repair, 4 pole,100A rating (Ics = 100% Icu),415Volts,16 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

3

-

-

... More
S&F in repair, 4 pole,125A rating (Ics = 100% Icu),415Volts,16 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

3

-

-

... More
S&F in repair, 4 pole,160A rating (Ics = 100% Icu),415Volts,36 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
S&F in repair, 4 pole,250A rating (Ics = 100% Icu),415Volts,36 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
S&F in repair, 4 pole, 400 A rating (Ics = 100% Icu),415Volts,36 kA rupturing capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including iron pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Note :- On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.

6

-

-

... More
Supply and fix in repair , install, testing & commissioning of LT busbar out-door type of sfactory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The box shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade aluminum bus-bar of rating 400A of length 600mm, min spacing of 80mm between the busbars & wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming cable rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including I/C & O/G cable opening on bottom & at both sides including MCCB 200 A , cable glands of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv box of any size/type complete all as specified & as directed.

2

-

-

... More
Notes :- (i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
M & L for repairs to feeder pillar box/LT panel etc, taking out old unserviceable and fixing of new hinges (if any) by welding/bolt nuts,addn/altn to MCCB enclosure cover with one incoming and No of out goings by grinding,cutting and painting all as shown and diretced, repairs to door lock by replacing unsv locks, extension of aluminium bus bars for incoming/outgoing MCCBs as per existing shapes and size, spray painting with two coats of approved grade & color synthetic enamel paint after scrapping incl preparation of old painted surfaces & fixing 02 nos (front & back) danger notice plate as per standard size complete all as specified and directed.

10

-

-

... More
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 200 A At 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed by Engr-Charge.

1

-

-

... More
All as per Item Sl No 32, here in above but suitable size for 160 Amp.

1

-

-

... More
M&L for provision of Display board of Size 59 X 36 Inch including conneted item for fixing arragement all as specified and directed by Engr- in- charge. (colour, specification menction in the boad desied by Engr in charge)

10

-

-

... More
M&L for provision of Display board of Size 42.5 X 23.75 Inch including conneted item for fixing arragement all as specified and directed by Engr- in- charge. (colour, specification menction in the boad desied by Engr in charge)

10

-

-

... More
M&L for provision of Display board of Size 12 X 24 Inch including conneted item for fixing arragement all as specified and directed by Engr- in- charge. (colour, specification menction in the boad desied by Engr in charge)

12

-

-

... More
M&L for MS angle iron post & struts in fencing incl cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets for securing wire mesh conforming to Fe-290 E-165 incl painting with one coat of red oxide primer & two coats of aluminium paint complete all as specified & as directed by the Engr-In-Charge.

100

-

-

... More
M&L for PCC 1:3:6, type B1 with 20 mm graded aggregate as in platform / floor complete all as specified & as directed by the Engr-In-Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.