Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Nov 2024
Closing Soon30 Dec 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685928_1Tender No
8778Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches complete all as specified and directed. (Note: Punned thickness only shall be measured and paid.)
141.91
-
-
... More
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed.
14016
-
-
... More
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor, removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing complete all as specified and directed.
Note:- Excavation and Earth work shall be measured and paid separately under appropriate item.
200
-
-
... More
All as per item No.6 above but 35 sqmm 3.5 core
350
-
-
... More
All as per item No.6 above but 50 sqmm 3.5 core
400
-
-
... More
All as per item No.6 above but 70 sqmm 3.5 core
350
-
-
... More
All as per item No.6 above but 95 sqmm 3.5 core
320
-
-
... More
All as per item No.6 above but 150 sqmm 3.5 core
250
-
-
... More
All as per item No.6 above but 185 sqmm 3.5 core
140
-
-
... More
All as per item No.6 above but 240 sqmm 3.5 core
180
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 25 sqmm 3.5 core complete all as specified and directed .
70
-
-
... More
Laying only the under ground cable any type obtained from Items No -07 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 35 sqmm 3.5 core complete all as specified and directed .
110
-
-
... More
Laying only the under ground cable any type obtained from Items No -08 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 50 sqmm 3.5 core complete all as specified and directed .
100
-
-
... More
Laying only the under ground cable any type obtained from Items No -09 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 70 sqmm 3.5 core complete all as specified and directed .
90
-
-
... More
Laying only the under ground cable any type obtained from Items No -10 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 95 sqmm 3.5 core complete all as specified and directed .
85
-
-
... More
Laying only the under ground cable any type obtained from Items No -11 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 150 sqmm 3.5 core complete all as specified and directed .
70
-
-
... More
Laying only the under ground cable any type obtained from Items No -12 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 185 sqmm 3.5 core complete all as specified and directed .
50
-
-
... More
Laying only the under ground cable any type obtained from Items No -13 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 240 sqmm 3.5 core complete all as specified and directed .
50
-
-
... More
Supply & Lay in trenches, fixed on wall (or) passing through pipes/in floors, connecting up, testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core complete all as specified and as directed.
130
-
-
... More
All as per item No. 22.00 above but 35 sqmm 3.5 core
240
-
-
... More
All as per item No. 22.00 above but 50 sqmm 3.5 core
300
-
-
... More
All as per item No. 22.00 above but 70 sqmm 3.5 core
260
-
-
... More
All as per item No. 22.00 above but 90 sqmm 3.5 core
235
-
-
... More
All as per item No. 22.00 above but 150 sqmm 3.5 core
180
-
-
... More
All as per item No. 22.00 above but 185 sqmm 3.5 core
90
-
-
... More
All as per item No. 22.00 above but 240 sqmm 3.5 core
130
-
-
... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 25 to 50 sqmm 3.5 core complete all as specified and as directed.
6
-
-
... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 95 sqmm 3.5 core complete all as specified and as directed.
5
-
-
... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 150 to 185 sqmm 3.5 core complete all as specified and as directed.
7
-
-
... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 240 to 300 sqmm 3.5 core complete all as specified and as directed.
5
-
-
... More
M & L for GI pipe light grade of size 50 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.
50
-
-
... More
M & L for GI pipe light grade of size 80 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.
24
-
-
... More
M & L for GI pipe light grade of size 100 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.
24
-
-
... More
S&F for PCC type C1 1:3:6 (20mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
2
-
-
... More
Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of "MES LT Cable " including 30 cm length angle iron support and embedded in and including PCC,including taking down existing old one complete all as specified and as directed.
40
-
-
... More
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-22 ( 8.5 metres long) including taking down existing old unserviceable ones complete all as specified and as directed.
20
-
-
... More
Excavation in trenches additional 1.5m or part there of in depth beyond the first 1.5 m and getting out excavated soil soft/loose soil complete all as specified and as directed.
1.62
-
-
... More
S& F for precast Cement concrete type B2 1:2:4 (20mm graded aggregate for copping complete all as specified and directed.
0.54
-
-
... More
S& F for precast Cement concrete type C-1 1:3:6 (40mm graded aggregate (for foundation) complete all as specified and directed.
17.82
-
-
... More
M&L for opening LT, 1100V, ACB front and back side complete after taking shutdown , cleaning, dusting inside & out side of ACB greasing oiling the mechanical parts of ACB and complete servicing including the replacement of the following :-
(a) Replacement of tripping coil 440V
(b) Replacement of contacts
(c) Replacement of wiring for tripping coil
(d) Replacement of indicating lamps
(e) Replacement of internal wiring for indicating lamps
4
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 63Amps 16 KA including taking out old u/s one complete all as specified and directed.
5
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 100Amps 16 KA including taking out old u/s one complete all as specified and directed.
4
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 125 Amps 16 KA including taking out old u/s one complete all as specified and directed.
5
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 160 Amps 36 KA including taking out old u/s one complete all as specified and directed.
5
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 200 Amps 36 KA including taking out old u/s one complete all as specified and directed.
3
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 250 Amps 36 KA including taking out old u/s one complete all as specified and directed.
3
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 350 Amps 36 KA including taking out old u/s one complete all as specified and directed.
3
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 400 Amps 36 KA including taking out old u/s one complete all as specified and directed.
5
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 500 Amps 36 KA including taking out old u/s one complete all as specified and directed.
2
-
-
... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 630 Amps 36 KA including taking out old u/s one complete all as specified and directed.
2
-
-
... More
S&F PVC Perforated Cable Tray of thickness 2mm on walls by suitable Cover plate, fixing clamps and jointing alongwith bends, elbows, tilts complete all as specified and directed for following size 50 mm (width) x 50mm (height) complete all as specified and directed.
50
-
-
... More
All as per Item No. 54 above but 100 mm (Width) x 50 mm (Height) complete all as specified and directed.
60
-
-
... More
All as per Item No. 54 above but 150 mm (Width) x 50 mm (Height) complete all as specified and directed.
50
-
-
... More
All as per Item No. 54 above but 200 mm (Width) x 50 mm (Height) complete all as specified and directed.
40
-
-
... More
Material and labour for finding out the cable fault of any size of cable upto LT underground cable and of any capacity of cable with the help of cable fault locator mounting on vehicle and with necessary disconnection of cable from two ends and making connection by joining after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessories- (a) Surge Generator with accessories
(b) Head Phone
(c) Pin Point Set T-505 with accessories
(d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.
3
-
-
... More
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 m deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machinery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%