Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date18 Dec 2024
Closing Date14 Jan 2025
Tender Amount₹ 19,94,000.0000000002 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DG Sets Details I(ad) DG set 20 KVA installed at 28 officers sewage pump House. I(ae) DG set 20 KVA installed at staion Armoury. I(af) DG set 20 KVA installed at 9 P &S Pallavam. I(ag) DG set 20 KVA installed at Golden Jubilee. I(ah) DG set 20 KVA installed at Culvert well. I(aj) DG set 15 KVA installed back side of Stn MT yard. I(ak) DG set 15 KVA installed at vishnu temple well. I(al) DG set 7.5 KVA installed at kiran DSS hanger (Front). I(am) DG set 7.5 KVA installed at kiran DSS hanger (Rear). I(an) DG set 7.5 KVA installed at kiran R & SS hanger (Front). I(ao) DG set 7.5 KVA installed at kiran R & SS hanger (Rear). I(ap) DG set 7.5 KVA installed at logistic section. I(aq) DG set 100 KVA trolley mounted for I&O level hanger. I(ar) DG set 82.5 KVA installed at sub station 'C'. I(as) DG set 82.5 KVA installed at BCR. I(at) DG set 62.5 KVA installed at MSR.

-

-

-

... More
M & L for inspection, maintenance and servicing of DG sets including Alternator, Non AMF/ AMF panels of connected DG sets for routine check up (B-check once in six month or 300 hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete services as per the manufacturers instructions all as specified and directed for DG set 250 KVA installed at FMS building. Note: Engine oil & Coolant shall be measured paid seperetaly under relevant item.

2

-

-

... More
All as per item No 2 above but for DG set 250 KVA installed at near ATC for FIS building.

2

-

-

... More
All as per item No 2 above but for DG set 250 KVA installed at CR & SS Hanger.

2

-

-

... More
All as per item No 2 above but for DG set 200 KVA installed at CPT Bldg.

2

-

-

... More
All as per item No 2 above but for DG set 160 KVA installed at Stn Logistic Section.

2

-

-

... More
All as per item No 2 above but for DG set 160 KVA installed at Roopavani.

2

-

-

... More
All as per item No 2 above but for DG set 125 KVA installed at C tank PH.

2

-

-

... More
All as per item No 2 above but for DG set 125 KVA installed at ATC.

2

-

-

... More
All as per item No 2 above but for DG set 125 KVA installed at SRE.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed Near Avonic Lab.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at 8 ASC.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at 35 MCU.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at GIS HQ bldg.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at MES Main pump House.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at FMS building.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at Telephone Exchange.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at Main Camp Sewage pump House.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at old Booster pump house at Madambakkam.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA installed at Moolgaonkar Block.

2

-

-

... More
All as per item No 2 above but for DG set 100 KVA trolly mounted for I & O Level hanger.

2

-

-

... More
All as per item No 2 above but for DG set 82.5 KVA installed at Near Sub Stn C.

2

-

-

... More
All as per item No 2 above but for DG set 82.5 KVA installed at BCR.

2

-

-

... More
All as per item No 2 above but for DG set 62.5 KVA installed at MRS.

2

-

-

... More
All as per item No 2 above but for DG set 62.5 KVA installed at Shiva temple well.

2

-

-

... More
All as per item No 2 above but for DG set 62.5 KVA installed at Mehra Hall.

2

-

-

... More
All as per item No 2 above but for DG set 62.5 KVA installed at Telephone Exchange.

2

-

-

... More
All as per item No 2 above but for DG set 62.5 KVA installed at Transmitter.

2

-

-

... More
All as per item No 2 above but for DG set 50 KVA installed at Narendra Place Pump House.

2

-

-

... More
All as per item No 2 above but for DG set 45 KVA installed at One lakh Pump House.

2

-

-

... More
All as per item No 2 above but for DG set 45 KVA installed Near Tower No 3.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at CADF Hut.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at 143 sewage pump House.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at 28 officers sewage pump house.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at station Armoury.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at 9 P&S Pallavaram.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at Golden jubilee pump House.

2

-

-

... More
All as per item No 2 above but for DG set 20 KVA installed at M & CWC Madambakkam.

2

-

-

... More
All as per item No 2 above but for DG set 15 KVA installed back side of Stn MT yard.

2

-

-

... More
All as per item No 2 above but for DG set 15 KVA installed at Vishnu temple well.

2

-

-

... More
All as per item No 2 above but for DG set 7.5 KVA installed at Kiran DSS hanger (Front).

2

-

-

... More
All as per item No 2 above but for DG set 7.5 KVA installed at Kiran DSS hanger (Rear).

2

-

-

... More
All as per item No 2 above but for DG set 7.5 KVA installed at Kiran R & SS hanger (Front).

2

-

-

... More
All as per item No 2 above but for DG set 7.5 KVA installed at Kiran R & SS hanger (Rear).

2

-

-

... More
All as per item No 2 above but for DG set 7.5 KVA installed at Logistic Section section.

2

-

-

... More
M & L for replacement of fan belt of any size for DG set of capacity 7.5 KVA to 20 KVA all as specified and as directed.

2

-

-

... More
All as per item No.46 above but of 45 KVA to 62.5 KVA

2

-

-

... More
All as per item No.46 above but of 82.5 KVA to 125 KVA

2

-

-

... More
All as per item No.46 above but of 160 KVA to 250 KVA

2

-

-

... More
M & L for replacement of diesel hose of size 5/16mm dia all as specified and as directed.

9

-

-

... More
M & L for replacement of radiator set hose of any sizes with clips (full set) all as specified and as directed.

4

-

-

... More
M & L for replacement of voltmeter 0-500V of size 96mm with all connection (Analogue type) all as specified and as directed.

4

-

-

... More
M & L for replacement of ammeter 0-100 Amps of size 96mm with all connection (Analogue type) all as specified and as directed.

4

-

-

... More
Supply only Engine oil 15 W 40 type make Servo or equivalent complete all as specified and directed.

800

-

-

... More
M & L for disconnecting, removing and dismantling water radiator assembly of 7.5/ 20/ 45/ 50/ 60/ 62.5 KVA DG Set and descaling the radiator thoroughly, completely with CTC solution/ any other chemical solvent agent as approved, stopping of leakage at places to copper cores and tubes by brazing, scrapping the existing oil paint, dusting and painting the radiator with enamelled paint, reinstalling and commissioning etc., complete all as specified and directed.

2

-

-

... More
All as per item No. 55 above but for DG sets of capacity above 82.5 KVA and upto 250 KVA

2

-

-

... More
M & L for disconnecting the existing battery of capacity 12 volts upto 180 AH from the DG Set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, start the engine for satisfactory function etc., complete all as specified and directed.

6

-

-

... More
M & L for removing/ replacing radiator cap complete all as specified and directed.

5

-

-

... More
M & L for replacing start switch/ ignition switch suitable for DG Set of capacity ranging from 7.5 KVA to 250 KVA complete all as specified and directed.

3

-

-

... More
M & L for replacing phase indication lamp for panel complete all as specified and directed.

20

-

-

... More
M & L for oil pressure gauge range 0-10 kg/sqcm complete all as specified and directed.

4

-

-

... More
M & L for DC ammeter/ voltmeter of any range complete all as specified and directed.

5

-

-

... More
M & L for repairs to 12 volts battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stater assembly, assembly refixing to the engine and testing for satisfactory charging of battery etc., complete all as specified and as directed.

7

-

-

... More
All as per item No.63 above but of 24 volts battery charging alternator

2

-

-

... More
M & L for repairs to 12/ 24 volts self starter by removing, dismantling and replacing unserviceable Armature and field coil including field coil tapping refixing to the engine including necessary testing for satisfactory function etc., complete all as specified and as directed.

4

-

-

... More
M & L for replacement of the worn out carbon brushes slip ring type in alternator of capacity 7.5KVA to 20 KVA DG set Kirloskar make including all necessary connected works etc., complete all as specified and as directed.

10

-

-

... More
M & L for replacement of the worn out carbon brushes slip ring type in alternator of capacity 45 KVA to 250KVA DG set Kirioskar make including all necessary connected works etc., complete all as specified and as directed.

10

-

-

... More
M & L for replacing the old unserviceable battery lead with copper terminals approximately 1 metre length including applying jelly over the battery pole and terminals etc., complete all as specified and as directed.

10

-

-

... More
M & L for replacement of the old unserviceable battery terminals including brazing work and applying jelly over the battery pole and terminals etc., complete all as specified and as directed.

2

-

-

... More
M & L for Scraping down the existing oily painted surface of the DG set of capacity 7.5 KVA to 20 KVA, making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coats of synthetic enamel paint over one coat of red oxide primer, painting Sl No & MES No over the DG set and alternator complete all as specified and directed.

3

-

-

... More
All as per item No 70 above but of 62.5 KVA to 125 KVA

3

-

-

... More
All as per item No 70 above but of 160 KVA to 250 KVA

3

-

-

... More
M & L for Draining out the existing diesel from the tank, kept at side for repouring, taking down the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carry out cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recalibration of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and testing for satisfactory function all as specified and directed.

8

-

-

... More
M & L for removing and replacing the old unserviceable AVR (Automatic voltage regulator) suitable for DG set 62.5 KVA to 125 KVA having input voltage 2 phase + neutral, sensing voltage 415 V, output voltage 95 volts DC, output current 4 A DC, voltage regulation +/- 1 % average volts, over excitation, current tripping, fuse protection 4 A, fast acting and frequency 50 Hz etc., complete all as specified and as directed.

5

-

-

... More
All as per item No.74 above but of 160 KVA to 250 KVA.

5

-

-

... More
M & L for replacing unserviceable combined digital meter for showing voltmeter, ammeter, frequency including necessary wiring and wiring material for connecting the meter etc., complete all as specified and as directed.

5

-

-

... More
M & L for removing and replacing the old unserviceable 12 volts auto cut-off battery charger in control panel as per existing type/ model including necessary wiring etc., complete all as specified and as directed.

5

-

-

... More
M & L for removing and replacing the old unserviceable 24 volts auto cut-off battery charger in control panel as per existing type/ model including necessary wiring etc., complete all as specified and as directed.

5

-

-

... More
S & F lead acid battery of size 12 volts 100 AH of reputed make including initial charging all as specified and as directed.

5

-

-

... More
S & F lead acid battery of size 12 volts 130 AH of reputed make including initial charging all as specified and as directed.

3

-

-

... More
S & F lead acid battery of size 12 volts 180 AH of reputed make including initial charging all as specified and as directed.

5

-

-

... More
Taking down FIP and disconnecting injectors from fuel lines upto 250 KVA, replacement and worn out spares like delivery valve, Nozzles, bearings, fly weight, packing kit, O ring kit and copper washer Kit and recalibration of FIP and refixing in same position and testing of full Load checking of pressure all as specified and directed.

1

-

-

... More
M & L for disconnecting the radiator from 7.5 KVA to 50 KVA DG Set and replacing unserviceable copper core, testing and commissioning complete all as specified and directed.

1

-

-

... More
M & L for disconnecting the radiator from 62.5 to 110 KVA DG Set and replacing unserviceable copper core, testing and commissioning complete all as specified and directed.

1

-

-

... More
M & L for replacing water pump assembly for DG set of any capacity of DG set complete all as specified and directed.

3

-

-

... More
Supply only coolant for DG Set radiator complete all as specified and directed.

100

-

-

... More
Dismantling of unserviceable AMFR logic controller of Control panel and replacing with new AMFR logic controller including replacement of existing unserviceable wiring with 1.5 sqmm PVC multistranded copper conductor single core 1100 V cable of voltmeter, indicator lamp, frequency meter etc complete all as directed.

1

-

-

... More
M & L for replacement of manual contactor ON/OFF-switch 16A-2P-2Way complete all as specified and directed. Make: C&S SAZER or equivalent.

3

-

-

... More
M & L for replacement of 4 pole power contactor for DG set capacity 250 KVA in control panel complete all as specified and directed. Make:L&T MCX 42 or equivalent.

1

-

-

... More
M & L for replacement 4 pole power contactor for DG set capacity 100/110 KVA in control panel complete all as specified and directed. Make:L&T MCX 32 or equivalent.

1

-

-

... More
M & L for replacement of 4 pole power contactor for DG set capacity 62.5 KVA in control panel complete all as specified and directed. Make:L&T MCX 22 or equivalent.

3

-

-

... More
M & L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 42 complete all as specified and directed. Make : L & T or equivalent.

2

-

-

... More
M & L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 32 complete all as specified and directed. Make : L & T or equivalent.

3

-

-

... More
M & L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 22 complete all as specified and directed. Make : L & T or equivalent.

3

-

-

... More
S & F 'Onload' change over switch 4 pole, 415 Volts, 200 Amps capacity complete all as specified and directed.

4

-

-

... More
S & F 'Onload' Change over switch 4 pole, 415 Volts, 100 Amps capacity complete all as specified and directed.

2

-

-

... More
M & L for earthing for pole complete with galvanized steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead strip 32 X 6 mm as earth lead by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point. The quoted rate is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as specified and directed.

7

-

-

... More
M & L for comprehensive maintenance of 10 person, 680 Kgs capacity passenger lift of Make : Johnson, Serving for ground plus five floors examining, adjusting, lubricating and repairs as required complete all as specified and directed by. Machine No of lift : L-C7190 Location : SRE ATC Building at Airforce station Tambaram. Comprehensive maintenance shall include the following works mentioned below:- Note (a) : Quoted rate shall deemed to be included for minor spares (for satisfactory functioning of lift. Other spare sparts listed in this schedule shall be measured and paid separately under relevant item . Note (b) : The rate deemed to be inclusive of insurance, renewal of lift and renewal of lift inspection from Tamilnadu government Lift Inspector and obtain necessary certificate and licence. Note (c) : Systematically examine and adjust the following components :- 1. Machine, Worm Gear, Thrust Bearings, Drive Sheave, Drive Sheave Bearings, Brake contact, Lining and Components. 2. Motor, Motor Generator, Motor Windings, Rotating Elements, Commutator, Brushes, Brush Holders, Bearings, Coils, Resistance for Operating and Motor Circuits, Magnet Frames and other Mechanical Parts.

4

-

-

... More
3.Controller, Selector, Levelling Devices, Cams, Relays, Solid State Components e.g. PCBs, Transducers, Resistors, Condensors, Power Amplifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mechanical and Electrical Driving Equipment. 4.Governor, Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws. 5.Car and Hall Mechanical Buttons, Car and Hall Position Indicators, Hall Lanterns, Car Direction Indicators and all other Car and Landing Signal Fixtures. 6.Deflector or Secondary Sheave, Bearings, Car and Counterweight Guide Rails and Buffers, Top and Bottom Limit Switches, Governor Tension Sheave Assembly, Compensating Sheave Assembly, Car, Counterweight and Counterweight Guide Shoes including Roller or Gibs. 7.Interlocks on Hoistway Door, Hoistway Door Hangers, Guides, Automatic Power Operated Door Operator, Car Door Hanger, Car Door Contact, Safety Shoe, Load Weighing Equipment, Car Frame, Car Safety Mechanism and Platform. 8.Furnish lubricants compounded to manufacturers stringent specifications. 9.Examine periodically all safety devices and governors and make all customary safety tests.

-

-

-

... More
Supply only cross flow fan of suitable size complete all as specified and directed.

1

-

-

... More
Supply only Charger Unit complete all as specified and directed.

1

-

-

... More
Supply only ARD Battery ( 12 V - 18 AH ) complete all as specified and directed.

4

-

-

... More
Supply only LED Round light fitting suitable for lift complete all as specified and directed.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.