Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date28 Nov 2024
Closing Date26 Dec 2024
Tender Amount₹ 99,00,000 
Notes
Download

Costs

Summary

Repair / Maint Of Dg Sets, Amf Panel Connected Parts And Lt Acb/mccb, Lt Feeder Panel, Junction Box And Connected Items At Domestic And Technical Area

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(b) 15 KVA TO 20 KVA DG set

8

-

-

... More
(c) 30 KVA DG set

6

-

-

... More
(d) 40 KVA DG set

8

-

-

... More
(e) 50 KVA DG set

4

-

-

... More
(f) 62.5 KVA TO 63 KVA DG set

8

-

-

... More
(g) 82.5 KVA DG set

5

-

-

... More
(h) 100 KVA DG set

2

-

-

... More
(j) 125 KVA DG set

5

-

-

... More
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 150 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge.

10

-

-

... More
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge.

7

-

-

... More
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 100 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge.

5

-

-

... More
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engr-in-charge. Note :- Spare Parts for rectify the fault is measured and paid seperately.

85

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 20 KVA to 30 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

2

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 40KVA to 50 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

3

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 62.5 KVA to 100 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

2

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 125 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

2

-

-

... More
M&L for Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge for the following capacity DG Sets. (a) up to 10KVA

4

-

-

... More
(b) 15 KVA to 20 KVA DG set.

4

-

-

... More
(c) 30 KVA DG set

3

-

-

... More
(d) 40 KVA to 50 KVA DG set

5

-

-

... More
(e) 62.5 KVA to 82.5 KVA DG set

5

-

-

... More
(f) 100 KVA to 125 KVA DG set

3

-

-

... More
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.

3

-

-

... More
Supply only Armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as directed by Engr-in-charge

5

-

-

... More
M & L rewinding of field coil for self starter of 24 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.

6

-

-

... More
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.

6

-

-

... More
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed by Engr-in-charge

4

-

-

... More
M & L rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.

5

-

-

... More
M&L for Disconnecting the oil cooler of capacity up to 62.5 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge

4

-

-

... More
M&L for Disconnecting the oil cooler of capacity above 82.5 KVA to 100KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge

4

-

-

... More
M&L for Disconnecting the oil cooler of above 125KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge

2

-

-

... More
M&L for Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed by Engr-in-charge: - (a) Upto 10 KVA DG Set

4

-

-

... More
(b) All as Item No 35 above but 15 KVA to 20 KVA DG set.

5

-

-

... More
(c) All as Item No 35 above but 30 KVA DG set

4

-

-

... More
(d) All as Item No 35 above but 40 KVA to 50 KVA DG set

6

-

-

... More
(e) All as Item No 35 above but 62.5 KVA to 82.5 KVA DG set

8

-

-

... More
(f) All as Item No 35 above but 100 KVA to 125 KVA DG set

3

-

-

... More
M&L for Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the following DG sets all as specified and directed by Engr-in-Charge: (a) Upto 10 KVA DG Set

4

-

-

... More
(b) All as Item No 41 above but 15 KVA to 20 KVA DG set.

3

-

-

... More
(c) All as Item No 41 above but 30 KVA DG set

4

-

-

... More
(d) All as Item No 41 above but 40 KVA to 50 KVA DG set

6

-

-

... More
(e) All as Item No 41 above but 62.5 KVA to 82.5 KVA DG set

8

-

-

... More
(f) All as Item No 41 above but 100 KVA to 125 KVA DG set

3

-

-

... More
M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as directed by Engr-in-charge

50

-

-

... More
S&F Automatic cut off type Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engr-in-charge.

4

-

-

... More
S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engr-in-charge.

8

-

-

... More
M&L for Renewal/replacement of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. (a) Upto 10 KVA DG Set

3

-

-

... More
(b) All as Item No 50 above but 15 KVA to 20 KVA DG set.

3

-

-

... More
(c) All as Item No 50 above but 30 KVA DG set

2

-

-

... More
(d) All as Item No 50 above but 40 KVA to 50 KVA DG set

4

-

-

... More
(e) All as Item No 50 above but 62.5 KVA to 82.5 KVA DG set

3

-

-

... More
(f) All as Item No 50 above but 100 KVA to 125 KVA DG set

3

-

-

... More
M&L for Renewal/replacement of fan belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation (a) Upto 10 KVA DG Set

3

-

-

... More
(b) All as Item No 56 above but 15 KVA to 20 KVA DG set.

2

-

-

... More
(c) All as Item No 56 above but 30 KVA DG set

2

-

-

... More
(d) All as Item No 56 above but 40 KVA to 50 KVA DG set

3

-

-

... More
(e) All as Item No 56 above but 62.5 KVA to 82.5 KVA DG set

4

-

-

... More
(f) All as Item No 56 above but 100 KVA to 125 KVA DG set

3

-

-

... More
M&L for Renewal/replacement of Dynamo belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation (a) Upto 10 KVA DG Set

3

-

-

... More
(b) All as Item No 62 above but 15 KVA to 20 KVA DG set.

3

-

-

... More
(c) All as Item No 62 above but 30 KVA DG set

2

-

-

... More
(d) All as Item No 62 above but 40 KVA to 50 KVA DG set

2

-

-

... More
(e) All as Item No 62 above but 62.5 KVA to 82.5 KVA DG set

1

-

-

... More
(f) All as Item No 62 above but 100 KVA to 125 KVA DG set

1

-

-

... More
M&L disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.

13

-

-

... More
M&L for replacement of existing unserviceable water temperature gauge with new water temperature gauge for the any capacity DG set of any description inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make

12

-

-

... More
M&L for replacement of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the any capacity DG set of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make

8

-

-

... More
M&L for replacement of existing unserviceable oil pressure gauge with new oil pressure gauge for the DG SET of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make

9

-

-

... More
M&L for replacement of unserviceable solenoid switch with new solenoid switch 12volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recomended

8

-

-

... More
M&L for replacement of unserviceable solenoid switch with new solenoid switch 24volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recommended

9

-

-

... More
S&F in repairs the following spare parts for any type/make of DG sets, as and when required by the department complete all as specified and directed.

-

-

-

... More
Starting/Ignition - key/button

8

-

-

... More
Volt Meter 0-500V

9

-

-

... More
Amps Meter

10

-

-

... More
Frequency Meter

8

-

-

... More
S.D Valve assembly

8

-

-

... More
Oil safety control

10

-

-

... More
Water safety control

12

-

-

... More
Water separator bowl 3247715

9

-

-

... More
Hour Meter

10

-

-

... More
Radiator Metal Pipes

12

-

-

... More
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engr-in-charge

1050

-

-

... More
Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all as directed by Engr-in-charge

638

-

-

... More
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 125 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended

3

-

-

... More
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set capacity up to 82.5 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended

3

-

-

... More
Drain out the fuel from the fuel tank of DG set of up to 82.5 KVA capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.

28

-

-

... More
Description all as per item No 89 above but upto100 to 125 KVA DG set complete all as directed by Engr-in-charge.

12

-

-

... More
S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 125 KVA capacity with all listed parameters including testing complete all as specified and directed.

5

-

-

... More
S&F in replacement of Rectifiers of existing Make to DG Set capacity up to 82.5 KVA capacity with all listed parameters including testing complete all as specified and directed.

8

-

-

... More
M &L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for up to 50KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.

4

-

-

... More
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 62.5 KVA to 82.5 KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.

4

-

-

... More
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 100 KVA to 125 KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.

3

-

-

... More
M&L disconnecting & removing the unservicable AC wiring from AMF panel of DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & replacement of electrical/electronic spares and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. (ii) Electrical/Electrnoc spares shall be measured & paid separately under relevant items.

12

-

-

... More
Supply only following spare parts :- (a) Push buttons.

9

-

-

... More
(b) AMF Panel Hooter

4

-

-

... More
(c) Earth fault relay.Make: OEM recomeded

9

-

-

... More
(d) Over load relay.Make: OEM recomeded

8

-

-

... More
(e) Over/Under voltage relay.Make: OEM recomeded

10

-

-

... More
(f) Auxilary relays 12v/6Amps Make: OEM recomeded

12

-

-

... More
(g) Power Contactor 4 pole,02 NO +NC,160 to 200

5

-

-

... More
(h) Power Contactor 4 pole,02 NO +NC,130

5

-

-

... More
(i) Power Contactor 4 pole,02 NO +NC,105

4

-

-

... More
(j) Power Contactor 4 pole,02 NO +NC,63 to 80

3

-

-

... More
(k) Power Contactor 4 pole,02 NO +NC,40 to 55

4

-

-

... More
(l) Power Contactor 4 pole,02 NO +NC,upto 32Amps,

5

-

-

... More
(m) Single phase preventer

8

-

-

... More
(n) Auxiliary Relays 24Volts / 6A Make: OEM recomeded

8

-

-

... More
(o) PLC based AMF relay unit Make: OEM recomeded

7

-

-

... More
(p) Low lube oil safety switch Make: OEM recomeded

8

-

-

... More
(q) Booster Relay 24Volts / 10A Make: OEM recomeded

6

-

-

... More
(r) Battery charger 24 V /10A panel mounting type Make: OEM recomeded

5

-

-

... More
(s) Battery charger 12 V /10A panel mounting type Make: OEM recomeded

6

-

-

... More
(t) Coolant temparature sensor Make: OEM recomeded

8

-

-

... More
(u) Power contactor 4 pole, 02NO+02NC,63 Amps

13

-

-

... More
(v) contactor operating coil of Power contactor 4 pole, 02NO+02NC,160 to 200 Amps

6

-

-

... More
(w) contactor operating coil of Power Contactor 4 pole,02 NO +NC,130 AmpsAmps

7

-

-

... More
(x) contactor operating coil of Power Contactor 4 pole,02 NO +NC,105 Amps

7

-

-

... More
(y) contactor operating coil of Power Contactor 4 pole,02 NO +NC,63 to 80 Amps

6

-

-

... More
(z) contactor operating coil of Power Contactor 4 pole,02 NO +NC,40 to 55Amps

6

-

-

... More
(aa) contactor operating coil of Power Contactor 4 pole,02 NO +NC,32Amps

4

-

-

... More
(ab) contactor operating coil of Power contactor 4 pole, 02NO+02NC,25 Amps

4

-

-

... More
M&L for Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.

5

-

-

... More
M&L for Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.

6

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares upto 63 KVA DG set for the following spares:- (a) Radiator rubber hoses.

2

-

-

... More
(b) Clamp for hump hose.

5

-

-

... More
(c) Hose clamps.

5

-

-

... More
(d) hump hose.

2

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 63 and upto 82.5 KVA DG set for the following spares:- (a) Radiator rubber hoses.

2

-

-

... More
(b) Clamp for hump hose.

4

-

-

... More
(c) Hose clamps.

4

-

-

... More
(d) hump hose.

2

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 82.5 kVA and upto 100 KVA DG set for the following spares:- (a) Radiator rubber hoses.

2

-

-

... More
(b) Clamp for hump hose.

4

-

-

... More
(c) Hose clamps.

4

-

-

... More
(d) hump hose.

2

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 100 kVA and upto 125 KVA DG set for the following spares:- (a) Radiator rubber hoses.

2

-

-

... More
(b) Clamp for hump hose.

4

-

-

... More
(c) Hose clamps.

4

-

-

... More
(d) hump hose.

2

-

-

... More
M&L for Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as directed by Engr-in-charge.

260

-

-

... More
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.

30

-

-

... More
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.

820

-

-

... More
S&F battery brass terminal and jelly complete all as specified and directed.

50

-

-

... More
M&L for Disconnecting all connection & remove the PT pump from engine and transport to OEM authorised service center and Calibration of PT pump for maximum efficiency by OEM Authorised Service center & replacement of PT Pump kit, gear gasket, etc in its original position by making all necessary connections complete whichever required under AGE E/M-II(U) AOR for smooth functioning of fllowing DG Set capacities complete all as directed by Engr-in-charge (a) DG Set capacity up to 20KVA

3

-

-

... More
(b) DG set capacity above 15KVA to 20KVA

3

-

-

... More
(c)DG Set capacity above 30KVA to 40KVA

2

-

-

... More
(d)DG Set capacity above 50KVA to 82.5KVA

3

-

-

... More
(d)DG Set capacity above 100KVA to 125KVA

2

-

-

... More
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity up to 40 KVA :- Note: Major spares required will be measured and paid seperately.

1

-

-

... More
Supply only orfice for 40 KVA capacity DG set

1

-

-

... More
Supply only Barrel and Plunger for up to 40 KVA capacity DG set

1

-

-

... More
Supply only FIP Bearing for up to 40 KVA capacity DG set

1

-

-

... More
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity 63 KVA :- Note: Major spares required will be measured and paid seperately.

1

-

-

... More
Supply only orfice for 63 KVA capacity DG set

1

-

-

... More
Supply only Barrel and Plunger for 63 KVA capacity DG set

1

-

-

... More
Supply only FIP Bearing for 63 KVA capacity DG set

1

-

-

... More
Supply and fix self starter Motor, 24 volts, Make LUCAS or its equivalent make approved by OEM of DG Set suitable for existing DG set above 82.5 KVA to 125 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge

6

-

-

... More
Supply and fix self starter Motor, 12 volts, Make LUCAS or its equivalent make approved OEM of DG Set suitable for existing DG set capacity up to 82.5 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge

6

-

-

... More
S&F Flexible Bellow suitable for up to 82.5 KVA Gen Set. Make as per OEM

4

-

-

... More
S&F Flexible Bellow suitable for above 82.5KVA and up to125 KVA Gen Set. Make as per OEM

4

-

-

... More
M&L for lifting the Gen Set above 82.5 KVA and up to 125 KVA after dissconnection complete from cables, Shifting to other place within 25 mtr sourrounding area and making PCC foundation of size suitable to existing DG Set with 1 : 2 : 4 PCC. Including smooth finishing. Shifting the DG Set on new foundation with all necessary arrangement of Cables Connections, Testing and commissioning complete all as directed by Engr-in-Charge. Notes :- All items & Manpower including Crane for lifting up and placing again on new foundation is included in quoted rates.

1

-

-

... More
M&L for lifting the Gen Set upto 82.5 KVA after dissconnection complete from cables, Shifting to other place within 25 mtr sourrounding area and making PCC foundation of size suitable to existing DG Set, with 1 : 2 : 4 PCC. Including smooth finishing. Shifting the DG Set on new foundation with all necessary arrangement of Cables Connections, Testing and commissioning complete all as directed by Engr-in-Charge. Notes :- All items & Manpower including Crane for lifting up and placing again on new foundation is included in quoted rates.

1

-

-

... More
M&L for Servicing of DG Set panel's ACB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated

2

-

-

... More
M&L for Servicing of DG Set panel's MCCB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated

2

-

-

... More
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to DG Set of capacity up to 82.5 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.

1

-

-

... More
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 82.5kVA up to 100 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.

1

-

-

... More
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 100 KVA up to 125kVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.

1

-

-

... More
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 82.5 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.

2

-

-

... More
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity above 82.5KVA and up to 125 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.

2

-

-

... More
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity 100 to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

3

-

-

... More
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity up to 82.5 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

2

-

-

... More
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 82.5 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

3

-

-

... More
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 100KVA up to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

2

-

-

... More
M&L for disconnecting all electrical & mechanical connections,Dismantle the Engine (make KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON) from 62.5KVA to 125 KVA DG set capacities located at various location under AGE E/M-II(U) and transported to OEM Authorised service center for complete overhauling, replacing the following unservicable worn-out spares with new appropriate make minor spares & major spares (minor spares- up to Rs 2500/Each), after assembling the spares the Engine again shfted to original existing place and reassembled to alternator& radiator,AMF panel/Electrical panel board of DG set complete testing, commissioning all as per OEM recomendation and as directed by Engr-in-charge.The quoted rate inclusive of Manpower, Crane charges for transporting engine to wokshop and back after repairs Note: - (i)Major Spare parts shall be measured and paid separately.

1

-

-

... More
Gear fuel Pump

1

-

-

... More
Total Gakets Set

1

-

-

... More
Core & cooler set

1

-

-

... More
Shaft rocker arm

2

-

-

... More
Oil seal

1

-

-

... More
Ball Bearings set

2

-

-

... More
Main Bearings set(STD)

1

-

-

... More
Material and labour for repairs to Alternator of following DG Set, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note: Copper winding material will be measured and paid seperately under relevant Item

-

-

-

... More
Upto 50 KVA capacity

3

-

-

... More
Above 62.5 KVA and upto 82.5 KVA Capacity

2

-

-

... More
Above 82.5 KVA and upto 100 KVA Capacity.

2

-

-

... More
Above 100 KVA and upto 125 KVA Capacity

1

-

-

... More
Supply only High conductivity copper conductor winding material including necessary insulation material as requred for complete all as specified and directed by Engr-in-Chrage

40

-

-

... More
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same for the following capacities including testing complete all as specified and directed.

-

-

-

... More
(a) DG Set of capacity above 5 KVA and up to 10 KVA

3

-

-

... More
(b) DG set capacity above 15KVA to 20KVA

3

-

-

... More
(c) DG Set capacity above 30KVA to 40KVA

4

-

-

... More
(d)DG Set capacity above 50KVA to 82.5KVA

3

-

-

... More
(e)DG Set capacity above 100KVA to 125KVA

3

-

-

... More
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it out side work to workshop, complete all as specified and directed:-

-

-

-

... More
(a) DG Set of capacity above 5 KVA and up to 10 KVA

2

-

-

... More
(b) DG set capacity above 15KVA to 20KVA

3

-

-

... More
(c) DG Set capacity above 30KVA to 40KVA

4

-

-

... More
(d)DG Set capacity above 50KVA to 82.5KVA

2

-

-

... More
(e)DG Set capacity above 100KVA to 125KVA

3

-

-

... More
M & L for dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Value Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed:-

-

-

-

... More
(a) DG Set of capacity above 5 KVA and up to 10 KVA

2

-

-

... More
(b) DG set capacity above 15KVA to 20KVA

2

-

-

... More
(c) DG Set capacity above 30KVA to 40KVA

4

-

-

... More
(d)DG Set capacity above 50KVA to 82.5KVA

2

-

-

... More
(e) DG Set capacity above 100KVA to 125KVA

2

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the 7.5 KVA to 25 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

2

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the above 25 KVA and up to 82.5 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

2

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the above 82.5 KVA and up to 100 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

2

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the above 125KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

2

-

-

... More
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.

11

-

-

... More
S&F in replacement of microprocessor based control unit suitable to DG set of 62.5 KVA to 82.5 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed.

2

-

-

... More
S&F in replacement of microprocessor based control unit suitable to DG set of 100 KVA to 125 KVA capacity with all listed parameters as per OEM recommendation including testing complete all as specified and directed.

2

-

-

... More
Supply&Fixing of 100/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.

1

-

-

... More
Supply&Fixing of 150/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.

1

-

-

... More
S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed.

300

-

-

... More
S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed .

260

-

-

... More
S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as specified and directed.

350

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 63A. open execution complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,100 A. open execution complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,160 A. open execution complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,200 A. open execution complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,250 A. open execution complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, open execution , 320 A complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, open execution 400 A complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 16 KA, 63 Amps complete all as specified and directed.

5

-

-

... More
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 100 Amps complete all as specified and directed.

4

-

-

... More
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 125 Amps.

3

-

-

... More
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 160 Amps

3

-

-

... More
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA, 200 Amps with adjustable thermal setting.

2

-

-

... More
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA,250 Amps with adjustable thermal setting.

2

-

-

... More
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA,315 Amps with adjustable thermal setting.

2

-

-

... More
Supply and fix in replacement MCCB ,3/4 pole,415V,50KA,400 Amps with adjustable thermal setting.

2

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes up to 16 sqmm 3.5/4 core ,1100 volts grade complete with jointing kit.

9

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 25 sqmm 3.5/4 core to 50 Sq mm x 3.5 core,1100 volts grade complete with jointing kit.

12

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 70 sqmm 3.5 core to 120 Sq mm x 3.5 core,1100 volts grade complete with jointing kit.

14

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 150 sqmm 3.5 core to 185 Sq mm x 3.5 core,1100 volts grade complete with jointing kit

12

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 240 sqmm 3.5 core to 300 sqmm 3.5 core 1100 volts grade complete with jointing kit.

8

-

-

... More
Supply and jointing Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 400 sqmm 3.5 core to 500 sqmm 3.5 core 1100 volts grade complete with jointing kit.

3

-

-

... More
Supplying and laying (in trenches/duct/fixing to pole/wall or in such similar position ) in replacement of extg u/s GI tubing medium grade for cable protection of following sizes:-

-

-

-

... More
(a) 80 mm dia

36

-

-

... More
(b) 50 mm dia

36

-

-

... More
(c )40 mm dia

30

-

-

... More
S & F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional of the following sizes laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc complete all as specified and directed.

-

-

-

... More
(a) 10 Sqmm 2 core

300

-

-

... More
(b) 10 Sqmm 4 core

300

-

-

... More
(c) 16 Sqmm 4 core

200

-

-

... More
(d) 25 Sqmm 3.5 core

500

-

-

... More
(e) 35 Sqmm 3.5 core

300

-

-

... More
(f) 50 Sqmm 3.5 core

300

-

-

... More
(g) 70 Sqmm 3.5 core

150

-

-

... More
(h) 95 Sqmm 3.5 core

150

-

-

... More
(i) 120 Sqmm 3.5 core

150

-

-

... More
(j) 150 Sqmm 3.5 core

150

-

-

... More
(k) 185 Sqmm 3.5 core

100

-

-

... More
(l) 240 Sqmm 3.5 core

100

-

-

... More
(m)300 Sqmm 3.5 core

100

-

-

... More
(n)400 Sqmm 3.5 core

100

-

-

... More
Excavation in soft loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engineer-in-Charge

550

-

-

... More
Excavation in soft loose soil not exceeding 1.5 mtr wide and exc 1.5 mtr depth and not exc 3.0 Mtr and getting out all as specified and directed by Engineer-in-Charge

20

-

-

... More
Excavation in hard and dense soil Iincluding Road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engineer-in-Charge

60

-

-

... More
Returning filling soft & loose/hard & dense soil including spreading levelling, watering and well ramming in layers n exc 25 cms all as specified and directed by Engineer-in-Charge..

330

-

-

... More
Removal of excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge..

206

-

-

... More
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable.

170

-

-

... More
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable as specified and directed.

14500

-

-

... More
M & L for cleaning vegetation around the around two/four pole structure & Panel boards area , sub stn and generator rooms etc completely root out from soil and clean the surface one mtr around the pole of street lights complete all as specified and directed. Note : Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land is deemed to be included in quoted rate.

3510

-

-

... More
S & F in repair digital Ammeter has automatic range of range from 0-250A, class 1.0,burden 15VA suitable to fix on existing LT Panel board including taking out old unserviceable item complete all as specified and directed.

6

-

-

... More
S & F in repair single phase in door Current Transformer of ratio 250/5A class 1.0/5P10,burden 15VA suitable to insert on alluminium bus bar of suitable rating including taking out old unserviceable CT from existing LT Panel board complete all as specified and as directed

4

-

-

... More
S & F in repair digital Voltmeter has automatic range selection facility of input voltage range from 0-500V , class 1.0, burden 15VA suitable to fix on existing LT Panel board including taking out old unserviceable item from existing LT Panel board complete all as specified and as directed

5

-

-

... More
Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size complete all as per specified and as directed.

260

-

-

... More
Note for item No 272 :- (i) The above work also include checking, detection and rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M).

-

-

-

... More
(ii) Hiring of cable fault detector to detect exact location of LT/HT UG cable fault deemed to be inclusive of quoted rate.

-

-

-

... More
(iii) Major items required to be replaced/repaired will be measured under relevant items of schedule.

-

-

-

... More
(iv) Excavation and earth work if required will be measured separately.

-

-

-

... More
(v) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days).

-

-

-

... More
(vi) In case of minor defect, entire job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300/- per hours shall be recovered.

-

-

-

... More
(vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.

-

-

-

... More
(viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 500/- per hours shall be deducted from the dues of the contractor.

-

-

-

... More
(ix) Note that penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding.

-

-

-

... More
(x) Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon and after noon to collect routine/urgent works till completion of work.

-

-

-

... More
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, color temp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel should be fitted with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket outside. 3 phase and neutral 600 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-

1

-

-

... More
(a) MCCB, with thermal magnetic release, 4 Pole, 415 Volt, of capacity 250 Amps, 36 KA - 1 No (Incomer) (b) MCCB, with Thermal magnetic release, 415 Volt, 4 pole, of capacity 100 Amps, 25 KA - 1 No (c) MCCB with Thermal magnetic release, 4 Pole, 63 Amps, 25 KA - 2 Nos (d) MCCB with Thermal magnetic release, 4 Pole, 63 Amps, 25 KA - 1 No (e) Volt Meter digital type 0-500 Volt with selector switches - 1 No (f) Ammeter digital type with CT for three Phase 0-400 Amps with selector switch - 1 Set (g) LED indication lamps with backup MCB for 3 phase supply –1 set (h) Space for spare feeder - 01 No.

-

-

-

... More
Repairing, overhauling, Servicing & testing of Air circuit breaker, 440V, 630 Amps to 1600 Amps, 50 KA, 3 Phase, 50 Hz, AC Supply system,for trouble free operation,and draw out type Air Ciruit breaker including the following works complete all as specified and directed. Location - MAFI PS 1, Sub Stn 'B' & 'D', Mehra Sub Stn, Simulator bldg, Avionic Eqpt bldg, EW block, ETB bldg, Electric logistic block, IFCS section, Mech CENGO section, Near LCA Hanger

16

-

-

... More
Note for item No 285 :- (a) The rate for following shall be deemed to be included in quoted rate.

-

-

-

... More
(b) The entire job shall be carried out through the authorised service engineers of the OEM only.

-

-

-

... More
(c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.

-

-

-

... More
(d) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the ACB trolly from the panels.

-

-

-

... More
(e) Servicing of Mech and elect inter locking system.

-

-

-

... More
(f) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(g) Servicing of Mech (caster lock) and elect inter locking system.

-

-

-

... More
(h) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
(j) Replacement of PT Fuse

-

-

-

... More
(k) Replacement of unserviceable spare parts will be measured and paid for separately.

-

-

-

... More
(l) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate.

-

-

-

... More
(m) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.

-

-

-

... More
Supply only against Item No. 285 above, Electrical closing coil 230 volt AC operated all as directed.

2

-

-

... More
Supply only against Item No. 285 above, Electrical shunt trip coil 230 volt AC operated all as directed.

2

-

-

... More
Supply only against Item No. 285 above spring charging assembly including motor 230 V AC operated all as directed.

2

-

-

... More
M & L Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.

24

-

-

... More
Note for item No 301 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-

-

-

-

... More
(i) Earth work excavation in any type of soil

-

-

-

... More
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.

-

-

-

... More
(iii) Removing excavated material to out side MD land

-

-

-

... More
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately

-

-

-

... More
(v) 150 mm thick PCC 1:2:4 type B1 as in road

-

-

-

... More
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the cable size from 50 sqmm to 95 sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.

30

-

-

... More
S & F LT, Air circuit breaker, operational voltage 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Electrically draw out type, rated current rating 800 amps and of breaking capacity 50 KA with quick make, quick break, with electrically operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating 400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed.

1

-

-

... More
S & F in repairs Surge arrester 9 kv /10 KV suitable for Load break switch complete all as specified and as directed

18

-

-

... More
M&L for preparation of old decorated surfaces of walls of LT panel plinth and applying one coat of cement based paint complete all as specified and directed.

20

-

-

... More
S & F LT, Air circuit breaker, operational voltage 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw out type, rated current rating 630 amps and of breaking capacity 50 KA with quick make, quick break, with manual operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating 400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed.

1

-

-

... More
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.

12

-

-

... More
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.

6

-

-

... More
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.

-

-

-

... More
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.

-

-

-

... More
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.

-

-

-

... More
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.

-

-

-

... More
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.

-

-

-

... More
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.

-

-

-

... More
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.

-

-

-

... More
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.

-

-

-

... More
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(xii) The electrode shall carry manufacturer's name .

-

-

-

... More
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.

-

-

-

... More
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (cost for copper strip deemed to be inclusive in quoted rate).

-

-

-

... More
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.

-

-

-

... More
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.

-

-

-

... More
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.

-

-

-

... More
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.

-

-

-

... More
M & L Boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe "heavy duty" of size 100mm bore fixed in repairs complete all as specified and directed

22

-

-

... More
M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 185 sqmm to 240sqmm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test complete all as specified and as directed by the Engineer-in-charge .

49

-

-

... More
M&L for removing rusted paint from LT panel and door hinjas appling two coat of powder coted synthetic paint and replacing of door injes and rubber beeding locking keys etc including repairing and repainting of lugs all as specified and directed by Engr-In-Charge

19

-

-

... More
Notes for all items :- (a) Daily Collecting of complaints from JE/AGE is responsiblity of Contractor. After collecting Complaints from Complaint Register or Insturction by JE by Phone/SMS, complaint should be completed within 48 Hours of complaint receiving, Major complaints/AMF panel wiring/Rewinding etc items should be completed within 05 days, (b) Minimum 01 Technician with all tools, ladder and testing Equipment, as per the site requirement shall be provided by contractor. (c) Every month complete testing for serviceablity of DG Set for all Generator shall be done and reports submitted to Engr- in -Chage at the end of every month (if items required shall be paid under relevant items given above). (d) Documents required for complaints like Stationery, Complaint Register, Slips & Site Order Book shall be provided by the contactor.(e) safety precautions shall be responsible by the contractor. (f) Contractor to comply all the respective notes of Particular Specifications attached.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.