Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Soon11 Dec 2024
Tender Amount₹ 29,98,500
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684545_1Tender No
8655/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L Rendering 10mm thick in fair faces of brick work or concrete surfaces in CM 1:3 finished even and smooth with out using extra cement but using water proofing compound (2% of weight of cement) complete all as specified and as directed by the Engineer-in-Charge. (WPC will be measured seperately).
679
-
-
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
279.65
-
-
M&L PCC1:2:4, type B1 using 20mm graded aggregate laid to slope 25mm thick as levelling course and finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
160
-
-
M&L Non skid ceramic coloured tiles 7 to 8mm thick area of each tiles exc 0.06 Sqm but not exc 0.11 Sqm in floors etc and jointed in neat cement slurry including 15 mm thick screed in cement mortar (1:6) pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed by the Engineer-in-Charge.
51
-
-
M&L Non skid ceramic coloured tiles 7 to 8mm thick area of each tiles exc 0.11 Sqm but not exc 0.18 Sqm in floors etc and jointed in neat cement slurry including 15 mm thick screed in cement mortar (1:6) pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed by the Engineer-in-Charge.
70
-
-
M&L Vitrified ceramic light shade tiles 10 mm thick area of each tiles n exc 0.36 Sqm in floors etc and jointed in neat cement slurry including 15 mm thick screed in cement mortar (1:6) pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed by the Engineer-in-Charge.
92
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
155
-
-
Rendering 10 mm thick CM 1:4 as in backing coat on fair faces of brick walls or concrete surface finished fair and even complete all as specified and as directed by the Engineer-in-Charge.
115
-
-
M&L glazed ceramic coloured 300x450x7 mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified.
115
-
-
Taking down or up old 15 mm steel tubing galvanised and connections including cleaning for refixing of serviceable tube all as specified and as directed by Engineer-in- Charge.
20
-
-
-Ditto- All as per ser No 13.0 above but 20 mm dia.
238
-
-
-Ditto- All as per ser No 13.0 above but 25 mm dia.
200
-
-
Supplying and laying of 16 mm dia (Outer) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
20
-
-
Supplying and laying of 20 mm dia (Outer) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
58
-
-
S & F Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
80
-
-
-Ditto- All as per ser No 18.0 above but 25 mm dia.
20
-
-
S & F refixing of old Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
100
-
-
-Ditto- All as per ser No 20.0 above but 25 mm dia.
180
-
-
S & F in repair cast copper alloy stop cock / angle cock chromium plated fancy type screwed down, high pressure screwed ends for 15mm pipe or for unions and all complete.
16
-
-
S & F in repair pillar taps 'Fancy type" cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered hot or cold with long screwed shanks and flynuts screwed for 15mm dia iron pipe complete all as specified and as directed by the Engineer-in-Charge.
8
-
-
S & F in repair for Chromium plated brass bib tap cast copper alloy, fancy type ,screwed down, screwed for 15mm dia iron pipe complete all as specified and as directed by the Engineer-in-Charge.
13
-
-
S&F in repair plastic water closet seat cover, white colour, closed pattern with, flat bottom, and cover and mild steel chromoum plated or aluminised hinging device complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
M&L PVC(SWR) multi floor trap plain with grating lincluding jointing with solvent cement 75mm dia complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and as directed by the Engineer-in-Charge.
35
-
-
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
S&F in repair Waste fitting brass chromium plated for glazed ware WHB with 32mm dia complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
S&F in repair stainless steel Waste coupling fitting suitable for stainless steel sink including rubber washer complete all as specified and directed by Engineer-in-Charge
6
-
-
S&F vitreous china squating pan "ORISSA' pattern or size 550 x 440mm white with integeral foot rest etc (Excluding flushing cistern and f;lush pipe) complete including trap set in cement motar & provision of lime concrete bedding and making good to floor, fixed in repairs complete all as specified and as directed by Engineer in Charge.
7
-
-
S&F vitreous china wash down water closet (pedestal pattern) white including connecting to trap and to flushing pipe anti syphonage pipe etc incl seat cover complete set in concrete flush pipe to closet including all joints and making good floor and wall complete all as specified and as directed by the Engineer-in-Charge.
6
-
-
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 ltrs and flush pipe syphonic action type, low level, white, with inlet, ball valve, float and handle including brackets of approved including taking down flushing cistern of any model complete all as specified and as directed by Engineer in Charge.
13
-
-
S&F Chromium plated cast copper alloy health facuet for 15mm dia incl 1.25 meter flexible telephonic tube and ABS wall hook incl making connection and fixed in position complete all as specified and as directed by the Engineer-in-Charge.
19
-
-
S&F vitreous china wash basin, flat back, size 550 x 400mm excluding taps ,waste pipe, including cutting for and pinning in ends of brackets or erecting stand and including bracket fixed in repair complete all as specified and as directed by Engineer in Charge.
6
-
-
S&F in repairs vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) basin only including connections to flushing pipe and outgoing pipes omplete all as specified and as directed by the Engineer-in-Charge.
6
-
-
S&F in repair low density 32mm dia polyethylene pipes (LDPE) of pressure rating 6 kgf/cm fixed to WHB/urinal waste pipes complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F in repair low density 40mm dia polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed to over flow outlet of water tank complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
18
-
-
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
2
-
-
M&L for Brick work with sub class B bricks, straight or curved on plan exc 6 mtr mean radius built in 1:6 cement mortar complete all as specified and as directed by Engr-in-Charge.
1
-
-
M&L for Brick work with old size fly ash bricks, straight or curved on plan in half brick thick walls built in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
13
-
-
Taking down cement plaster on wall / ceilng surfaces including racking out joints, hacking for key scrubbing down with water etc receive new plaster complete all as specified and directed by Engr-in-Charge.
441
-
-
Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr -in- Charge
70
-
-
M&L for rendering in CM 1:4, 15mm thick on external surfaces of concrete and brick masonry using water proofing compound @ 3% by the weight of cement and finished the surfaces even and smooth without using extra cement all as specified and directed by Engr-in-charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
305
-
-
Rendering 5mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engr -in- Charge.
75
-
-
M&L for preparation of new decorated surfaces and applying three coat of white wash on ceiling complete all as specified and directed by Engr -in- Charge.
75
-
-
M&L for preparation of new plastered surfaces of wall and applying two coats of exterior weather coat paint including one coat primer complete all as specified and directed by Engr -in- Charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
305
-
-
M&L for applying 3mm thick internal wall care putty complete all as specified and directed by Engr -in- Charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
375
-
-
M&L for preparation of new decorated surfaces and applying two coat of distemper over a coat of primer on walls complete all as specified and directed by Engr -in- Charge.
70
-
-
Refixing shutters in same opening of any description of area exc 1 Sqm but n.exc 2 Sqm each all as specified and as directed.
10
-
-
S&F in repairs aluminium alloy anodised hinges 75 mm.
12
-
-
S&F 100mm Butt hinges, medium weight, cold rolled mild steel in repairs
8
-
-
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connectionn of required size complete for capacity exc 250 but n.exc 500 ltrs all as specified and directed.
3
-
-
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connectionn of required size complete for capacity exc 500 but n.exc 1000 ltrs all as specified and directed.
3
-
-
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connectionn of required size complete for capacity exc 1000 but n.exc 2000 ltrs all as specified and directed.
3
-
-
Dismantling water tanks 1000 ltr capacity of any type including disconnecting from pipe all as specified and as directed by the Engineer-in-Charge.
1
-
-
-Ditto- All as per ser No 57.0 above but 500 ltr capacity.
1
-
-
S&F Rotational moulded polyethylene water storage tanks, 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including connectng to pipe all as specified and as directed by the Engineer-in-Charge.
1
-
-
-Ditto- All as per ser No 59.0 above but 500 ltr capacity.
1
-
-
S&F PVC ball valves, 20mm dia bore, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule all as specified and as directed by the Engineer-in-Charge.
12
-
-
Demolition of cement concrete in floors/roof surfaces including removal of old tarfelt, plastering, concrete mugs, tiles etc up to the original RCC roof level including removal of debries from site all as specified and directed by Engineer-in-Charge.
126.55
-
-
M&L for PCC 1:2:4 TYPE B0 using 12.5 mm graded aggregate in roof as levelling course, kerbs or mud stops, rounded or chamfered on edges
28.5
-
-
Water proofing treatment with water base polyurethane modified dispersion shall be carried out all as specified as under: -
(a) Mechanical cleaning of surface to make it free from any bituminous residue / dirt. Oil and greese etc all as directed by GE / Engineer-in-Charge.
(b) Cracks treatment by cutting open cracks and cleaning it from dirt loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge.
(c) Applying water based polyurethane modified dispersion (single component cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by GE / Engineer-in-Charge.
Properties of polyurethane based chemical shall be as follows: -
(i) Highly elastic
(ii) UV resistance
(iii) Adhesion to concrete 1N/Sqmm.
(iv) Tensile strength - not less than 2.0N/Sq.mm for free film.
(v) Elongation - not less than 300%.
(vi) Solid content by weight - not less than 60%.
(vii) Air / water perimeability BSEN 12390 at 5 bar - 72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0m.
(viii) Accelarated weathering (ASTM 453): Pass 1000 hours.
(ix) Reaction to fire - non inflammable.
Note: (i) To be applied by the manufacturer's authorized applicator only. Contractor has to provide manufacturer's test certificate for the above mentioned technical parameters and purchase Vrs.
(ii) Removal of existing treatment to be paid separately.
(iii) Roof top to be ensured to avoid water ponding.
(iv) For accessible terrace and inaccessible terrace, 300mm height of vertical surface / parapet wall to be treated with same specification of slab.
Make: Berger, Fosroc, or any other make approved by E-in-C's Branch for PU based water proofing treatment.
634
-
-
S&F 75 mm bore PVC SWR pipe single socketed in any length with rubber ring joints fixed to wall for soil waste (Note :- Item No 21 to 30 of this schedule will be executed at an height of 15- 20 meter from Ground Level)
105
-
-
-Ditto-All as per ser No 65 above but 110 mm bore.
180
-
-
M&L PVC(SWR) shoe in 110mm dia any radius
8
-
-
S&F PVC (SWR) pipes single socketed, 75mm dia, in any length, jointed with rubber ring joints, , laid in trenches or in floors incl taking down existing old pipe complete all as specifed and directed.
12
-
-
-Ditto-All as per ser No 68 above but 110 mm bore.
17
-
-
S&F PVC (SWR) bends suitable for 75mm bore pipes, complete all as specified and directed.
13
-
-
-Ditto-All as per ser No 70 above but 110 mm bore.
22
-
-
S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
4
-
-
-Ditto- All as per ser No 72 above but 110 mm bore.
3
-
-
PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping etc wiith slightly chamferred or rounded angles including necessary form work if any, and finishing exposed surface even and smooth without using extra cement.
0.5
-
-
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20mm bore pipe all as specified and directed by Engineer-in-Charge.
6
-
-
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 25mm bore pipe all as specified and directed by Engineer-in-Charge.
5
-
-
M&L repairs to RCC ceiling/Column/Beam, pressure grouting / injection grouting with plasticized, non shrink cement / mortar admixture applied in and around areas showing seepage on roof slab, column beam junctions and other location using shaligrout IP / EI from STP Ltd / Dr Fixit Epoxy injection / EPCO-K-HP250 OF M/s Krishna Conchom. (Pressure grouting shall be done at 0.30 m intervals using 12 mm dia nozzle, depth of hole shall be minimum 50 mm for rcc shalbs and 100 mm for beams / Columns) Rate include cost of labour, materials, tools, plant, water / Electricity charges). Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
15
-
-
M&L for Chipping the cracked / loose spalled concrete on the soffit of slab / beam using proper tools like hammer, chisel etc. and removing the loose particle completely duly cleaning it with wire brush and removing the dust etc. complete until to reach sound good concrete surface and deeping the surface dry and removing the debris and dumping the same at the nominated locations as directed by the Engineer in charge with all lead and lift etc. Complete. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
15
-
-
M&L cleaning the existing deteriorated reinforcement by sand blasting / mechanical rotary brushes wherever reinforcement is corroded by more than 30% providing extra reinforcement of new cold twisted CRS bars including cutting, bending and strainghtening and placing in position complete in all levels and if necessary welding the new bars with the exg. Rods by over lapping with all lead and lift etc. Complete and as directed by the Engineer in charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
45
-
-
Removing the loose particles rust / mild scale deposits completely duly cleaning it with wire brush / crush sheet etc. and removing the dust etc complete over the old concrete surface and supply of zinc rich epoxy primer NITOZINC PRIMER and mixing mechanically untill it is homogenous with all lead and lift etc. complete and as directed by the Engineer in charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
3.5
-
-
Apply one coat of rust remover chemicals such as feovert from Krishna conchom/ Rust remover from Dr Fixit/ shali Rustoff from STP/on steel surface including all lead and lift etc completed all as directed by Engineer in Charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
2
-
-
Repair to slab & beam using structural grade ready mixed epoxy mortar such as EPCO-KP-HP-350 Krishna Conchom / Epoxy repair mortar from Dr Fixit / Nitobond AR & RenderocS2 of FOSROC. After surface preparation the substrate should be throughly soaked with water (any excess being removed) Prior to applying one coat of Nitobond SBR and scrbbing it well into the surface. Renderoc S2 can be applied as soon as the Nitobond AR become tracky. Place about 2.75 litres of drinking quality water in the mixer and, add the supplied liquid polymer part and mix with the machine in operation, add Renderoc S2 powder and mix for 2 to 3 minutes apply the mixed Renderoc S2 to the prepared substrate with a gloved hand or trowel. First work a mini layer of the mortar on to the layer. Thoroughly compact the mortar on to primed substrate. Where thicker sections are required, the surface of the intermediate layer should be scratch keyed and primed with Nitobond AR. Repriming with Nitobond AR and further application of Renderoc S2 may proceed as soon as this layer has set. Renderoc S2 is finished by strking off with a straight edge and closing with a steel float. Applying one coat of acrylic curing membrance NITOBOND AR mixed with water in the ratio 1:1 with all lead and lift etc, complete and as directed by the Engineer-in-Charge.Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
15
-
-
M&L for preparation of old surfaces of walls and applying two coat of exterior weather coat paint complete all as specified and directed by the Engineer-in-Charge. Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
200
-
-
M&L for APP based polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3mm thick reinfored with polyster non wooven fabric ( wt not less than 160gm/sqm) laid over primed surfaces includingbituminous primer conforming to IS-3384applied @ 0.3 Ltr/Sqm by by forced all as specified and directed.
Four course roof treatment cosist of as under
(i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 Ltr/ Sqm
(ii) Laying of APP based membrane as specified thickness and weight (iii) Applying one coat bitumen grade 85/25@1.2kg/sqm
(iv) Applying two coat aluminium paint @100ml/Sqm
609
-
-
GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal or Chicken wire mesh, studding, joists, etc. in walls, ceilings, stanchions, beams, coving etc. including all laps, cutting and waste Note :- The work shall be carried out in building at height from ground floor to 4th floor. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work.
8
-
-
Supply and installation of high performance industrial roof vent of 600 mm dia neck of aluminium alloy designed to meet ASS-2428 dated 28 Jan 1993 to wind speed of 200 Km / hr and to the entry of wind driven rain at a range of 2.5 litre per second inclusive of base plate and including all accessories and taking down existing one all as specified and as directed.
12
-
-
Supply only Calcium hypo chlorite Granules packing size ne less than 45Kg , 65-95 concentration complete all as specifed and directed.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%