Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 23,00,000
Costs
EMD
₹ 46,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
87709 Repair/replacement Of Ht Ug Cable Fault Finding Works And Ht Joints To Ht 11kv Vcbs And Other Maint Work At Various Sub Station Under Ge(m) Arakkonam M) Arakkonam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691483_1Tender No
CWE/NAVY/ARK/87709/E8 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Taking up old /existing unserviceable defective HT 11000V UG Cable of size 185 sqmm 3 core from the existing trenches/ near panels and keep a side carefully and segrigating serviceable portion of cable for Reuse complete including cutting vagitation from cable route before takingdown all as specified and as directed Note:- (a) Excavation/ earth work shall be measured and paid seprately under relavent items. (b) Retrieved serviceable cable cover from site be properly stacked and reused as protection to HT UG cable and shall be measured and paid separetely under relevent items. (c) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
250
-
-
... More
All as per item No 4 above but for 95 sqmm 3 core complete all as specified and directed.
90
-
-
... More
Supply, laying, testing for replacement against unserviceable part of item No 3 here-in- before XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sqmm 3 core complete all as specified and directed.
100
-
-
... More
Supply, laying, testing for replacement against unserviceable part of item No 4 here-in-before XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm 3 core complete all as specified and directed .
50
-
-
... More
Relaying in trenches serviceable electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sqmm 3 core retrieved from ground complete all as specified and directed.
150
-
-
... More
All as per item No 8 above but for 95 sqmm 3 core complete all as specified and directed.
40
-
-
... More
M&L for HT Cable jointing kit for cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed.
2
-
-
... More
M&L for HT Cable jointing kit for cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
2
-
-
... More
M&L for HT Cable jointing kit for cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed.
2
-
-
... More
M&L for HT Cable jointing kit for cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
2
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specified and directed
152
-
-
... More
Spreading, levelling riddled earth as obtained from exvavation in cable trenches all as specified and directed.
37
-
-
... More
Supply and laying unreinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 x 40 mm for cable protection complete all as specified and as directed
630
-
-
... More
Relaying in trenches serviceable un-reinforced precast concrete cable cover, retrieved from item ground complete all as specified and as directed
420
-
-
... More
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
91.2
-
-
... More
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
60.8
-
-
... More
Material and labour for cast iron cable route indicator of standard size circular/eleptical shaped incl 25 x 6 mm angle iron stud with slanting top duly embossed ' HT CABLE ' including and planted on PCC foundation 1:3:6 type C2(40mm aggregate) 300x300x100mm complete including taking out old damaged indicators and demolition of PCC near old indicators, necessary earth work, site clearance, painting and preparation of surface complete all as directed.
25
-
-
... More
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
24
-
-
... More
M & L Galvanised iron tubing 100 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
12
-
-
... More
Material and labour for servicing, overhauling HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/type and checking door lock system, checking for phase sequence, mechanical and electrical interlocking system, complete wiring checking of relays, trip coil, spring charge motor, closing coil etc, tightening all the mechanical and electrical joints complete and writing with paint the Feeder name and checking the functionality in position after servicing complete all as specified and as directed. Note: (a) Quoted rate includes S&F all small screw nut bolt and wires and all other items required during servicing. (b) Replacement of unserviceable major spare parts required only shall be measured and paid separately as supply only under relevant items here-in-after however fixing charges/labour cost for the spares to be included in the quoted rate.
30
-
-
... More
Material and labour for calibration of HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/type including relay,tripping mechanism etc as per standard/ specified/directed by OEM certified agency and submitting report all as specified and as directed.
30
-
-
... More
Servicing of 11KV RMU 600 Amps SF6 KISOK circuit breakers outdoor type replacement of unservivable spare parts ,checking of mechanism, fixed and moving contacts, removing of carbon deposits on fixed and moving contacts, checking of control wiring, trripping circuit wiring, testing of CT insulation resistance values and testing of operation manual and remote all as directed.
8
-
-
... More
Material and labour for cutting of existing VCB panel to fixing of louvers type ventilatoer pre assembled type of size 300mm x300mmx 300mm, incl polishing and spray panintng as existing colour complete all as specified and as directed .
8
-
-
... More
S&F Replacing of PCB in existing Battery Charger 230/30Volts of any make including testing and installing of battery Charger complete all as directed by Engr-in-charge. Make: Schneider /ABB/ CG
1
-
-
... More
Supply only the following spare parts for HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/typeall as specified and as directed NOTE : (i) labour cost for taking down old u/s item and fixing of following new items deemed to be included in quoted rate.
-
-
-
... More
Current Transformer 600 to 1250 Amp Make: Schneider/ABB/CG/Kappa
3
-
-
... More
Fuse pt type Make: Schneider/ABB/CG/Kappa
8
-
-
... More
Door lock handle with key Make: Schneider/ABB/CG
10
-
-
... More
Axulory switch Make: Schneider/ABB/CG/Kappa
4
-
-
... More
Battery for Power pack,12 V,7AH Make: Exide/Amron/TATA
25
-
-
... More
Battery for Power pack,12 V,24 AH Make: Exide/Amron/TATA
25
-
-
... More
Anticondensation space heater Make: Schneider/ABB/CG
4
-
-
... More
Space panel heater thermostwd Make: Schneider/ABB/CG
4
-
-
... More
VCB rack gear with charging handle set Make: Schneider/ABB/CG
1
-
-
... More
11 KV epoxy hausing cashing for vaccum interrupter Make: Schneider/ABB/CG
2
-
-
... More
Vaccum interrupter (bottle type) Make: Schneider/ABB/CG
2
-
-
... More
Isolate, disconnect, dismantle the burnt out lugs from the main connections and crimping with proper new 95 Sqmm and 185 Sqmm lugs and glands as per existing one including fixing insulation tape termination to main connections complete all as directed.
6
-
-
... More
Servicing of 11KV 3-Phase Gang Operated Device including replacing the defective items and applying mineral Jelly, grease after proper removal of carbon deposits, refixing of Switch A/B Gang operated triple pole mechanically operated mounted on isolator and steel frame with operating mechanisam works from Ground level, complete all as directed.
3
-
-
... More
Supplying only Tinned Copper fuze wire of following for 30 Amp to 50 Ampcapacity
3
-
-
... More
All as per item No 31 above but for Capacity 60 Amp complete all as specified and directed.
3
-
-
... More
All as per item No 31 above but for Capacity 100 Amp complete all as specified and directed.
3
-
-
... More
Supplying only insulation tape 16mmx7mtrx0.125mm, complete all as specified and directed.
250
-
-
... More
Renewal of 11 KV burn out jumper with new Aluminium jumper with Aluminium jumper (existing size) with new aluminium clamp including bolt nuts and washers complete all as directed.
8
-
-
... More
Servicing of existing On Load Tap Changer of Power Transformer including opening nut bolt, gasket and repair/ replacement of wornout parts/ coils, moving contact and testing to founctioning properly complete all as directed
7
-
-
... More
Testing of wiring including disconnection and reconnections from control panel to transformer buchauls relays, winding temperature, oil temperature, oil level temperature cutout relay, master trip relay, auxillary protection relay complete all as directed. Note :- The rates included with all spares parts.
1
-
-
... More
Renewal of unserviceable burnt out HT support insulator 11 KV capacity all material including of SF-6 breaker with & including necessary fixing complete all as directed.
8
-
-
... More
M&L Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/components for replacement to be provided free by department)
2
-
-
... More
M & L switch air brake gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps 11000 volts complete all as specified and as directed.
2
-
-
... More
M&L Air break (switch) insulator for 11000 volts 400 amps complete all as specified and as directed.
3
-
-
... More
M&L Lightning arresters polymer/expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 Volts complete all as specified and as directed. Fixed with two pole structure at MRS, ATC, LRMR,IOCL, thirumal pur and Def civilian qtr substn complete all as specified and directed.
12
-
-
... More
Supply and fixing MCB, SP 5 to 32 AMP rating 240V, 10KVA'C curve miniature ciruit breaker (MCB) complete suitable for 200 KVAR capacito bank each of 100 KVAR capacity complete all as directed.
19
-
-
... More
Taking down the unserviceable disc insulator and S&F new disc type polymer disc insulator vitreous brown 145mm height and 255mm dia ball and socket type single disc assembly with GI clamp nuts and bolts etc suitable for 11000 V grade working pressure complete all as directed .
4
-
-
... More
Taking down the unserviceable HT 11 KV, Pin insulator and S&F new Pin type polymer pin type insulator vitreous brown 150 mm dia,top groove 19mm with GI spindle and other accssoriesle suitable for 11000 V grade working pressure complete all as directed.
10
-
-
... More
Supply and fix danger notice plate of 1.6mm thick size HT 25 x 20 cm of mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved of size including taking down rusted danger plates complete all as specified and as directed
15
-
-
... More
M&L Cement concrete in foundations, filling & mass concrete type D2 1:4:8 using 40mm graded aggregate complete all as specified and directed.
8
-
-
... More
Material and labour for PCC for coping /road cutting/earth pit chamber for existing poles/location whereever necessary, 1:3:6 type C-1 (Using 20mm graded stone aggregate) complete all as specified and as directed.
8
-
-
... More
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
50
-
-
... More
Supply and spread graded stone aggregate 40mm in structure yard 2/4 poles complete all as directed
6
-
-
... More
M&L for cleaning the 2 Pole structure of steel pole of any height including Cross arm and Angles, fitting of any description clean thoroughly with cleaning agent including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of synthetic aluminium paint (From copping to GOD) and two coat of Red postal colour Paint from GOD to above of pole and sturcture, over one coat of red oxide metal primer paint before 01 Day of aluminium & Red painting, and marking of Strip (01 to 03) by Fluroscent Paint as per KV Grading up to a height of 1.5m above, the PCC coping painted with 02 coats of black synthetic enamel paint including writing of pole numbers complete all as directed. Note :- Zebra Strip size & Colour of painting as directed by Engr -in-Charge at the time of execution.
4
-
-
... More
M&L for cleaning the 2 Pole structure of PCC pole of any height including Cross arm and Angles, fitting of any description clean thoroughly with cleaning agent including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of cement paint (From copping to GOD) and two coat of Red postal colour Paint from GOD to above of pole and sturcture, over one coat of red oxide metal primer paint before 01 Day of aluminium & Red painting, and marking of Strip (01 to 03) by Fluroscent Paint as per KV Grading up to a height of 1.5m above, the PCC coping painted with 02 coats of black synthetic enamel paint including writing of pole numbers complete all as directed. Note :- Zebra Strip size & Colour of painting as directed by Engr -in-Charge at the time of execution.
3
-
-
... More
Surface dressing upto 15cm deep in and around transformer yard , four pole, two pole, three pole structure vicinity and clearing of vegetation/soil to a distance not exceeding 50m complete all as specified and as directed
1050
-
-
... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or fixed to poles or any other indicated situated for loop earthing etc. as required GI earth strip of size 32x6mm complete all as directed.
64
-
-
... More
Material and labour for repairing the existing eart pit chamber, before removing the existing twisting earth pit sink into the ground, broken rcc cover and RCC chamber, funnel, etc. with replacement of new RCC cover and RCC chamber watering funnel with wire mess of existing size and improve the earth value with added water and salt and findout the earth value using digital earth tester after disconnection of earth electrode from earth chamber for maintaining the record and fill the data in earth test register incl writing the earth value on earth pit with date of measurement complete all as specified and as directed
54
-
-
... More
Material and labour for Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m deep below normal ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground connected to GI earth strip 32 x 6mm by means of GI bolts and nuts, washers and GI earth strip protected by GI pipe light grade 40mm bore upto 7.5 mtr and connecting to HT/ LT switch gear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10cm C/C on both ways as reinforcement complete all as shown in electrical plate No 3 of MES Schedule Part 1 (2009) connected to earthing test points complete all as specified and as directed by Engineer-in-Charge. Note :- (i)Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc. (ii) GI earth strip 32 x 6mm, GI tubing light grade 50mm dia upto 7.5 mtr deemed to be included the rate quoted by the contractor. (iii) Beyond 7.5 mtr the GI earth strip 32 x 6mm & GI pipe light grade 50mm dia shall be measured under relevant item of the schedule.
12
-
-
... More
Schedule of credit amount brought back from Ser Page No.30 - Rs.23,603.00 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR
-
-
-