Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Nov 2024
Closing Date18 Dec 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Summary

Repairs Replacement Of Lt External Electrification Distribution Network And Connected Accessories At A, B D Area Under Ge Chennai

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches complete all as specified and directed. (Note: Punned thickness only shall be measured and paid.)

210.6

-

-

... More
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed.

20800

-

-

... More
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor, removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing complete all as specified and directed. Note:- Excavation and Earth work shall be measured and paid separately under appropriate item.

340

-

-

... More
All as per item No.6 above but 35 sqmm 3.5 core

450

-

-

... More
All as per item No.6 above but 50 sqmm 3.5 core

610

-

-

... More
All as per item No.6 above but 70 sqmm 3.5 core

550

-

-

... More
All as per item No.6 above but 95 sqmm 3.5 core

420

-

-

... More
All as per item No.6 above but 150 sqmm 3.5 core

350

-

-

... More
All as per item No.6 above but 185 sqmm 3.5 core

250

-

-

... More
All as per item No.6 above but 240 sqmm 3.5 core

280

-

-

... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 25 sqmm 3.5 core complete all as specified and directed .

90

-

-

... More
Laying only the under ground cable any type obtained from Items No -07 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 35 sqmm 3.5 core complete all as specified and directed .

110

-

-

... More
Laying only the under ground cable any type obtained from Items No -08 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 50 sqmm 3.5 core complete all as specified and directed .

160

-

-

... More
Laying only the under ground cable any type obtained from Items No -09 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 70 sqmm 3.5 core complete all as specified and directed .

135

-

-

... More
Laying only the under ground cable any type obtained from Items No -10 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 95 sqmm 3.5 core complete all as specified and directed .

80

-

-

... More
Laying only the under ground cable any type obtained from Items No -11 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 150 sqmm 3.5 core complete all as specified and directed .

75

-

-

... More
Laying only the under ground cable any type obtained from Items No -12 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 185 sqmm 3.5 core complete all as specified and directed .

60

-

-

... More
Laying only the under ground cable any type obtained from Items No -13 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 240 sqmm 3.5 core complete all as specified and directed .

40

-

-

... More
Supply & Lay in trenches, fixed on wall (or) passing through pipes/in floors, connecting up, testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core complete all as specified and as directed.

250

-

-

... More
All as per item No. 22.00 above but 35 sqmm 3.5 core

340

-

-

... More
All as per item No. 22.00 above but 50 sqmm 3.5 core

450

-

-

... More
All as per item No. 22.00 above but 70 sqmm 3.5 core

415

-

-

... More
All as per item No. 22.00 above but 90 sqmm 3.5 core

340

-

-

... More
All as per item No. 22.00 above but 150 sqmm 3.5 core

275

-

-

... More
All as per item No. 22.00 above but 185 sqmm 3.5 core

190

-

-

... More
All as per item No. 22.00 above but 240 sqmm 3.5 core

240

-

-

... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 25 to 50 sqmm 3.5 core complete all as specified and as directed.

4

-

-

... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 95 sqmm 3.5 core complete all as specified and as directed.

6

-

-

... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 150 to 185 sqmm 3.5 core complete all as specified and as directed.

12

-

-

... More
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 240 to 300 sqmm 3.5 core complete all as specified and as directed.

4

-

-

... More
M & L for GI pipe light grade of size 50 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.

50

-

-

... More
M & L for GI pipe light grade of size 80 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.

55

-

-

... More
M & L for GI pipe light grade of size 100 mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.

45

-

-

... More
S&F for PCC type C1 1:3:6 (20mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.

2

-

-

... More
Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of "MES LT Cable " including 30 cm length angle iron support and embedded in and including PCC,including taking down existing old one complete all as specified and as directed.

24

-

-

... More
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-22 ( 8.5 metres long) including taking down existing old unserviceable ones complete all as specified and as directed.

30

-

-

... More
Excavation in trenches additional 1.5m or part there of in depth beyond the first 1.5 m and getting out excavated soil soft/loose soil complete all as specified and as directed.

2.43

-

-

... More
S& F for precast Cement concrete type B2 1:2:4 (20mm graded aggregate for copping complete all as specified and directed.

0.81

-

-

... More
S& F for precast Cement concrete type C-1 1:3:6 (40mm graded aggregate (for foundation) complete all as specified and directed.

26.73

-

-

... More
M&L for opening LT, 1100V, ACB front and back side complete after taking shutdown , cleaning, dusting inside & out side of ACB greasing oiling the mechanical parts of ACB and complete servicing including the replacement of the following :- (a) Replacement of tripping coil 440V (b) Replacement of contacts (c) Replacement of wiring for tripping coil (d) Replacement of indicating lamps (e) Replacement of internal wiring for indicating lamps

3

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 63Amps 16 KA including taking out old u/s one complete all as specified and directed.

7

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 100Amps 16 KA including taking out old u/s one complete all as specified and directed.

8

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 125 Amps 16 KA including taking out old u/s one complete all as specified and directed.

6

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 160 Amps 36 KA including taking out old u/s one complete all as specified and directed.

5

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 200 Amps 36 KA including taking out old u/s one complete all as specified and directed.

5

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 250 Amps 36 KA including taking out old u/s one complete all as specified and directed.

4

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 350 Amps 36 KA including taking out old u/s one complete all as specified and directed.

5

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 400 Amps 36 KA including taking out old u/s one complete all as specified and directed.

6

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 500 Amps 36 KA including taking out old u/s one complete all as specified and directed.

4

-

-

... More
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 630 Amps 36 KA including taking out old u/s one complete all as specified and directed.

3

-

-

... More
S& F for GI earthing strip 25x4 mm with nut and bolts complete including taking down old one all as specified and directed.

60

-

-

... More
S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers, buried in ground including excavation and taking down existing old ones complete and all as specified and directed.

44

-

-

... More
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. Necessary foundation work as per manufacturer instruction including foundation and including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and connecting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.

2

-

-

... More
Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleeves. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) S&F Digital Multi Function meter Nos -01 (d ) S&F for MCCB 630 Amp 50 KA 4 pole Thermal magnetic setting complete - N0s -01 (e) Change over 400 AMps 4 pole complete Outgoing (a ) S&F MCCB of 4 pole of capacity 100 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (b ) S&F MCCB of 4 pole of capacity 125 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (c ) S&F MCCB of 4 pole of capacity 200 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 02 Nos (d ) S&F MCCB of 4 pole of capacity 250 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 02 Nos (e) S&F MCCB of 4 pole of capacity 315 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 01 No

-

-

-

... More
Material and labour for finding out the cable fault of any size of cable upto LT underground cable and of any capacity of cable with the help of cable fault locator mounting on vehicle and with necessary disconnection of cable from two ends and making connection by joining after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessories- (a) Surge Generator with accessories (b) Head Phone (c) Pin Point Set T-505 with accessories (d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.

3

-

-

... More
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 m deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machinery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.