Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date19 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666769_1Bid Award Id
ViewTender No
8137/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete
7.56
-
-
M & L for brick work with old size Fly ash bricks in CM 1:4 straight or curved on plan exc 6 m mean radius
20
-
-
M&L for brickwork with fly ash bricks , straight or curved on plan to any radius in half brick thick walls built in CM 1:4
15
-
-
M&L for rendering in CM 1:4, 15 mm thick on fair faces of brick work , including finishing the surface even and smooth without using extra cement with WPC Note: WPC shall be measured and paid separately
200
-
-
M& L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping and benching incl weathering slightly rounded or chamfered angles and throating as directed including form work all as directed.
4.38
-
-
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends
70
-
-
M&L for reinforced concrete pipes of 300mm dia bore of pipe, class NP3, laid and jointed complete with collars
20
-
-
M&L for Concrete bed to drain pipes of 300mm dia using PCC 1:4:8 Type D2 with 40 mm graded stone aggregate including packing under and completely surrounding pipes with concrete after they are laid and tested
20
-
-
S&F PVC (SWR) pipes single socketed 75mm bore of Class B, in any length with rubber ring joints laid in trenches or floors or in walls all as specified.
100
-
-
S&F PVC (SWR) bends 75mm bore
8
-
-
S&F PVC (SWR) bends with access door 75mm bore
12
-
-
S&F 75 mm PVC (SWR) branch piece, single (single Y) equal or unequal with access door
8
-
-
S&F PVC (SWR) pipes single socketed 110mm bore of Class B, in any length with rubber ring joints laid in trenches or floors or in walls all as specified.
100
-
-
S&F PVC (SWR) bends 110mm bore
12
-
-
S&F PVC (SWR) bends with access door 110mm bore
15
-
-
S&F 110mm PVC (SWR) junction single (single T) equal or unequal with access door.
8
-
-
M&L for form work to soffit and sides of slabs supported on walls of flat rough finished surfaces of concrete
20
-
-
M&L for RCC (Nominal Mix) of type B1 1:2:4 using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed
1.5
-
-
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-s or Fe-410-0
100
-
-
Dismantling fencing wire mesh any type
540
-
-
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete, including taking out embedded portion and making good disturbed ground
180
-
-
Material and labour for PCC 1:3:6 type C2 40mm stone graded aggregate as in foundations, filling and mass concrete all as specified.
38.88
-
-
Fixing only chain link fencing in-cluding line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.
540
-
-
Supply only PVC coated chain link fencing galvanised any size or type.
1728
-
-
M&L for MS posts struts in fencing including cutting tops to shape as directed, drillings holes, notching for wire, etc, flat irons fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165
1956
-
-
Supply and fix 10mm dia MS round bars including welding with necessary lapping all as directed Gde IS-432 (Part-I )
666.36
-
-
Supply and fix mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long with diameter of shank 11 to 15mm all as specified
66
-
-
M&L for two coats of synthetic enamel paint over a coat of red oxide primer to new steel surface including preparation of surfaces of any description over 10cm width or girth all as specified and as directed
86.4
-
-
M&L for two coats of synthetic enamel paint over a coat of red oxide primer to new steel surface including preparation of surfaces of any description n.exc 10cm width or girth all as specified and as directed
108
-
-
Supply and Fix in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed Note: Each line wire to be measured.
50
-
-
M&L for providing 100mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors and pavings etc. all as specified and as directed
120
-
-
M&L for Sand filling under floors or in foundations including watering and consolidation
6
-
-
M&L for machine pressed Pre cast rubber finished coloured PCC interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade of cement concrete of with grey cement and pigment all as specified and directed.
120
-
-
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment incl 15mm thick cement screed bed in CM 1:6
70
-
-
M&L for 75mm thick PCC 1:3:6 C-2 type using 40mm graded stone aggregate as in plinth protection/hard standing finishing cement concrete surface even and smooth without using extra cement.
70
-
-
Removing of drain cover slab of any size and replacing same after removing mud/silt etc including making good the damaged surfaces with PCC/plastering, all as directed
Note:- Removal of Mud/silt will be measured and paid Separately.
150
-
-
Removing accumulated silt/mud/vegetation of any kind inside the drain, scrapping, digging etc by any means manually and disposing the same at a level n.exc 1.50m above the starting point at a distance n.exc 1.0km and cleaning the surroundings of the drain complete all as specified and directed.
150
-
-
M&L for cutting down plants/trees of upto 10cm girth and applying ROUNDUP/GLYPOCET or equivalent (Herbal medicine) to roots of roof tops/sides, external walls of bldg chajjas, wall junctions, at junctions of rain water/CI waste water pipe junction including taking out possible quantities of roots entered in wall/slab surfaces and making good the surfaces including repairing the GI/CI/ACC/PVC pipe joints of that affected locations after applying herbal medicine making good to suit the adjoining surfaces shall be carried out using PCC (1:2:4) type 'B1' or cement mortar 1:2 with necessary scaffolding/staging etc upto a height of 7.00m from the ground level all as directed and as specified.
80
-
-
M&L for cutting down plants/trees of girth exc 10cm and n.exc 15 cm and applying ROUNDUP/GLYPOCET or equivalent (Herbal medicine) to roots of roof tops/sides, external walls of bldg chajjas, wall junctions at junctions of rain water/CI waste water pipe junction including taking out possible quantities of roots entered in wall/slab surfaces and making good the surfaces including repairing the GI/CI/ACC/PVC pipe joints of that affected locations after applying herbal medicine making good to suit the adjoining surfaces shall be carried out using PCC (1:2:4) type 'B1' or cement mortar 1:2 with necessary scaffolding/staging etc upto a height of 7.00m from the ground level all as directed and as specified.
40
-
-
Earth work in excavation in hard/ dense soil by mechanical means (Hydraulic excavator)/in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm on plan), including dressing of sides and ramming of bottom lift upto 1.5 m, including getting out excavated soil and disposal of surplus soil as directed with in a lead of 50 m.
47
-
-
Returning, filling in, using excavated soil including spreading, levelling watering and well ramming in layers n.exc 25cm with excavated soils all as specified.
42
-
-
Taking down cement plaster on brick wall including raking out joint hacking for key scrubbing down the water etc.
80
-
-
Supply only Liquid Water proofing Chemical (LWPC)
7.42
-
-
Demolition of reinforced cement concrete in any position and description
Note:- Reinforcement to be cut as required to facilitate demolition)
2.6
-
-
M&L for providing precast cement concrete type 1:2:4 B-1 using 20 mm graded stone aggregate, as in man hole covers and set in cement mortar 1:6. Note :- Reinforcement shall be measured and paid separately.
2.6
-
-
M&L for MS TMT bars 6 mm to 8 mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia.
150
-
-
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in beds of drain all as specified .
2.8
-
-
Demolition and breaking up 150 mm dia salt glazed ware, AC or Reinforced concrete pipe jointed in cement mortar and disposed off the premises all as directed.
200
-
-
Demolition and breaking up 200 mm dia (salt glazed ware, AC or Reinforced concrete) pipe jointed in cement mortar and disposed off the premises all as directed.
50
-
-
M&L for PCC 1:3:6, type C2 using 40mm grade stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore all as specified
200
-
-
M&L PCC 1:3:6, type C2 (using 40mm grade stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 200mm bore all as specified
50
-
-
M&L for reinforced concrete pipes 150mm bore, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM 1:1 and tested as specified.
190
-
-
M&L for reinforced concrete pipes 200mm bore, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM 1:1 and tested as specified.
46
-
-
Removing of sewage sludge from under ground sewage sump/septic tank and cleaning of any size and deep including cleaning of side walls, all-round removal of accumulated sludge, silt, mud etc, and covering the same with earth, recommissioning septic tank including site clearance around 3 metre depositing outside camp area all as directed.
60
-
-
Bailing out water from septic tank of any size & deep and cleaning inlet and outlet sewer lines including taking out the sewage water and carting away it from the defence area all as directed. Note: Item No.58 & 59 Bailing sewage water to be taken out with proper tanker vehicle meant for the purpose with due care considering health hazards.
100
-
-
Cleaning of manholes by bailing out fluid and removing sediments, washing manhole floors and walls with wire brush taking out the excavated sludge, and carting away the same far away from buildings/living area and deposit at low lying area/ditches and cover with fresh earth on top complete all as specified and as directed.
-
-
-
Manhole depth not exc 1.00m
300
-
-
Manhole depth exc 1.00m
400
-
-
Cleaning the existing SGSW/CI/SWR/RCC sewage pipe line by roding manually or mechanically and removing all sludge and foreign matters completely and neatly from the pipe line and making serviceable for free flow of sewage in 100mm dia of pipe all as specified and directed
150
-
-
All as per item No 60 here in before but 150 mm bore of pipe
3500
-
-
All as per item No 60 here in before but 200 mm bore of pipe
1000
-
-
Cleaning and removing individual blockages in IWC/EWC by manually or mechanically and removing all sludge and foreign matters completely, neatly and making serviceable for free flow all as specified and directed
80
-
-
Cleaning and removing individual blockages from nahani trap/ floor trap/ gully traps in Bath rooms/Kitchen etc. by manually and removing all sludge and foreign matters completely, neatly and making serviceable for free flow and placing the covers/ gratings in position all as specified and directed
240
-
-
Pumping out rainwater from drains, low lying areas etc by mechanically and disposing the same out side the premises all as directed.
105
-
-
Cleaning the PVC service water tanks by removing out water, cleaning floor, wall with wire brush and bleaching powder and removing mud, dusts, fungus and cleaning the floor and walls surface with fresh water complete for the capacity of tank up to 500 litres all as directed.
65
-
-
All as per item No 66 here in before exc 500 but n.exc 1000 litres capacity
40
-
-
All as per item No 66 here in before exc 1000 litres but n.exc 2000 litres capacity.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements