Indian Oil Corporation Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indian Oil Corporation Limited - IOCL Tender

Works
Security and Emergency Services
Eprocure
Opening Date11 Oct 2024
Closing Soon28 Nov 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
IR Based explosion proof & weather proof (Point Type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.

3

-

-

... More
IR Based explosion proof & weather proof (Open Path type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.

2

-

-

... More
UV / IR Flame Detectors explosion proof & weather proof along with allmounting & other accessories as per the tender specifications.

11

-

-

... More
Intrinsically safe Rate of Rise Heat Detectors for hazardous areas alongwith all mounting & other accessories as per the tender specifications

11

-

-

... More
Manual Call Point (Explosion Proof & Weather Proof) for hazardous areasalong with all mounting & other accessories as per the tender specifications.

2

-

-

... More
Beacons (Explosion Proof & Weather Proof) for hazardous areasalong with all mounting & other accessories as per the tender specifications.

1

-

-

... More
Explosion Proof / Weather Proof Hooters (for hazardous area) along with all mounting & other accessories as per the tender specifications.

1

-

-

... More
Surge Protection Devices for analog signals from 3 wire Infrared Hydrocarbon Detectors & 3 wire UV/IR Flame Detectors

11

-

-

... More
Flame proof and weather proof junction boxes including supplyof EP/WP double compression cable glands, plugs for unused cable entries including EP/WP certificates as per the tender specifications for UV/IR flame detectors, IR type hydrocarbon detectors & IS heat detectors in hazardous areas.

2

-

-

... More
Test Lamp for UV/IR flame detector of same make as the UV/IR flame detectors.

1

-

-

... More
Calibration kit for Open Path Hydrocarbon detectors along with requisite filters and accessories complete in all respect.

1

-

-

... More
Explosion proof Telephone Instruments as per tender technical specifications

2

-

-

... More
8 Port Industrial grade Ethernet Switch as per tender specifications

4

-

-

... More
Optical to Ethernet Media Converter compatible to owner supplied signle mode OFC including supply of all accessories and pigtails

4

-

-

... More
Serial to Ethernet Converter : Industrial grade ethernet to 2-4 port serial gateway/Modbus TCP to Modbus RTU converter with all accessories

6

-

-

... More
Supply of Cards along with rack for extension of LEL channels from 32 to 64

1

-

-

... More
Unarmoured CAT6 cable as per tender technical specifications

300

-

-

... More
2 Pair 1.5 Sqmm (2P X 1.5 SQMM) Signal cable as per tender technical specifications

500

-

-

... More
1 Triad 1.5 Sqmm (1T X 1.5 SQMM) Signal cable as per tender technical specifications

500

-

-

... More
8 Triad 1.5 Sqmm (8T X 1.5 SQMM) Signal cable as per tender technical specifications

500

-

-

... More
4 Core 1.5 Sqmm (4C X 1.5 SQMM) Control cable as per tender technical specifications

500

-

-

... More
12 Core 1.5 Sqmm (12C X 1.5 SQMM) Control cable as per tender technical specifications

500

-

-

... More
Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications

500

-

-

... More
2 Pair x 1.5 Sq. mm, unarmoured FRLS cable complaint to BS: EN 50288-7 as per the tender specifications for indoor applications to be laid through PVC/Metaliic conduits.

500

-

-

... More
Armoured CAT6 cable as per tender technical specifications

100

-

-

... More
EPABX 5 Pair Armoured PIJF underground telephone cable

500

-

-

... More
Wall mounted telephone socket

2

-

-

... More
Thin Client along with Keyboard, Mouse and other accessories as per tender technical specifications

1

-

-

... More
Group-A : Services (Chennai Pump station)

-

-

-

... More
Supervision, erection, testing & commissioning of SIL rated LEL detector panel, including termination of power & signalling cables, wiring of hydrocarbon detectors, including all interfacing with PLC system etc making all jobs complete as per drawings / specifications and acceptance of the system by Owner. This includes supply of all labour, consumables, tools,services rendered etc

1

-

-

... More
Installation, testing & commissioning of Rate of Rise Heat Detectors for safe area & hazardous area,laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with existing Fire Alarm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, material etc

10

-

-

... More
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench with excavated earth, as directed by Site Engineer, including all labour and materials complete as per drawings, specification and directions of Site Engineer.

45

-

-

... More
WBM ROAD / CONCRETE BREAKING: WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) as per specifications and direction of the Site Engineer, job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any.

22.5

-

-

... More
CABLE LAYING: Laying of armoured / unarmoured Cables having outer diameter upto 20 mm (control / signalling/ Triad/ LT cable etc.) and installation / pulling of telephone cables of all type in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels, in buildings, walls, ceilings, and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect,as per specifications,drawings and directions of the SiteEngineer, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths

3000

-

-

... More
CABLE LAYING: Laying of armoured / unarmoured Cables having outer diameter between 20 mm to 30 mm (control / signalling/ Triad/ LT cable etc.) and installation / pulling of telephone cables of all type in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels, in buildings, walls, ceilings, and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect,as per specifications,drawings and directions of the SiteEngineer, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths

500

-

-

... More
PLC and SCADA Modifications/Creation in the Control System HMI graphics & logic for the Control System including development/ modification of new database, tags, PLC logic and all related jobs for inclusion of upcoming facilities at respective stations. Work includes Modification/Development of MMI graphics and uploading of the same in the existing workstations, engineering cum programming terminal etc. as per the scope of the work and specifications to complete the job in all respects for incorporation of upcoming facilities as per the specifications, drawings and directions of the Site Engineer and submission of "As built" documentation. The work also includes providing data to the SCADA vendor and assisting the same for incorporation of the changes in the SCADA.

2

-

-

... More
Dismantling of Existing F&G system including removal of cables, Gas release panels, fire supression system etc.

1

-

-

... More
Training on the supplied F&G system as p

1

-

-

... More
Group-A : Composite (Chennai Pump station)

-

-

-

... More
Installation of explosion proof / flame proof junction boxes for marshalling of control / signalling cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Junction Boxes) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineerincluding all labour, tools, materials, glanding, ferruling etc.complete in all respects.

2

-

-

... More
Installation of Infrared Hydrocarbon detectors (Point type / Open path type), terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respects as per specifications.

2

-

-

... More
Installation of UV/IR Flame Detectors, terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the UV/IR Flame detector) complete in all respect as per specifications.

10

-

-

... More
Installation of Explosion Proof & Weather Proof Manual Call Point/ Hooters/ Beacons/ Telephone instrument in Hazardous area, terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Manual Call Point/ Hooter/ Beacon) complete in all respect as per specifications.

6

-

-

... More
FM 200 based clean agent Fire suppression system: Supply, installation, testing & commissioning of FM 200 gas based clean agent Fire Suppression System complete as per NFPA 2001 to complete the work in all respects inclusive of supply of all consumables, cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC a) FM 200 based clean agent cylinders (minimum 80 l capacity) in configuration of set of two banks (1 set = 1 main & 1 standby cylinder) complete with weighing device, safety valve and all accessories.

2

-

-

... More
FM 200 based clean agent filled in cylinders

480

-

-

... More
All sizes of piping for FM 200 clean agent dispersion complete with nozzles, manifold , all type of hoses, etc to complete the work in all respect

140

-

-

... More
Supply , installation & interfacing of Gas release panel with Fire alarm panel to achieve the functionality of clean agent dispersion

1

-

-

... More
Group-B : Supply (Chittoor Pump station)

-

-

-

... More
6 loop, Addressable, Intelligent Fire Detection and Alarm Panel with FM200/ CO2 release facilities for automatic fire detection & an nunciation of alarms for various types of detectors installed like multi sensor, heat detectors, response indicators, loop isolator s, manual call points, hooters etc installed in plant area and various buildings as per tender specifications

1

-

-

... More
LEL Controller (32 Channel & SIL-2 Certifed) as per tender specifications

1

-

-

... More
IR Based explosion proof & weather proof (Open Path type) Hydrocarbon detectors along with all mounting & other accessories as per t ender specifications.

1

-

-

... More
UV / IR Flame Detectors explosion proof & weather proof along with allmounting & other accessories as per the tender specifications.

6

-

-

... More
Multi sensor detectors along with all mounting & other accessories asper the tender specifications

200

-

-

... More
Intrinsically safe Rate of Rise Heat Detectors for hazardous areas alongwith all mounting & other accessories as per the tender spec ifications

15

-

-

... More
"Isolators for isolating of signalling loop in case of any fault alongwith all mounting & other accessories as per the tender specifications."

25

-

-

... More
Response Indicators along with all mounting & other accessories as per the tender specifications

100

-

-

... More
Monitor modules alongwith all mounting & other accessories for third party interface as per the tender specifications.

15

-

-

... More
Addressable Hooters / Horn / Strobe (for safe area) along with all mounting & other accessories as per the tender specifications.

10

-

-

... More
Manual Call Point (Explosion Proof & Weather Proof) for hazardous areasalong with all mounting & other accessories as per the tender specifications.

15

-

-

... More
Addressable Manual Call Point (for safe area) along with all mounting & other accessories as per the tender specifications.

20

-

-

... More
Beacons (Explosion Proof & Weather Proof) for hazardous areasalong with all mounting & other accessories as per the tender specifica tions.

4

-

-

... More
Addressable Beacons for safe area along with all mounting & other accessories & instructions sign as per the tender specifications.

10

-

-

... More
Explosion Proof / Weather Proof Hooters (for hazardous area) along with all mounting & other accessories as per the tender specific ations.

4

-

-

... More
Surge Protection Devices for analog signals from 3 wire Infrared Hydrocarbon Detectors & 3 wire UV/IR Flame Detectors

30

-

-

... More
Flame proof and weather proof junction boxes including supplyof EP/WP double compression cable glands, plugs for unused cable entrie s including EP/WP certificates as per the tender specifications for UV/IR flame detectors, IR type hydrocarbon detectors & IS heat d etectors in hazardous areas.

5

-

-

... More
Test Lamp for UV/IR flame detector of same make as the UV/IR flame detectors.

1

-

-

... More
Calibration kit for Open Path Hydrocarbon detectors along with requisite filters and accessories complete in all respect.

1

-

-

... More
Explosion proof Telephone Instruments as per tender technical specifications

4

-

-

... More
Serial to Ethernet Converter : Industrial grade ethernet to 2-4 port serial gateway/Modbus TCP to Modbus RTU converter with all acce ssories

6

-

-

... More
Unarmoured CAT6 cable as per tender technical specifications

300

-

-

... More
2 Pair 1.5 Sqmm (2P X 1.5 SQMM) Signal cable as per tender technical specifications

500

-

-

... More
8 Triad 1.5 Sqmm (8T X 1.5 SQMM) Signal cable as per tender technical specifications

750

-

-

... More
4 Core 1.5 Sqmm (4C X 1.5 SQMM) Control cable as per tender technical specifications

1500

-

-

... More
12 Core 1.5 Sqmm (12C X 1.5 SQMM) Control cable as per tender technical specifications

500

-

-

... More
40 Core 1.5 Sqmm (40C X 1.5 SQMM) Control cable as per tender technical specifications

300

-

-

... More
Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications

700

-

-

... More
2 Pair x 1.5 Sq. mm, unarmoured FRLS cable complaint to BS: EN 50288-7 as per the tender specifications for indoor applications to be laid through PVC/Metaliic conduits.

1000

-

-

... More
Armoured CAT6 cable as per tender technical specifications

100

-

-

... More
EPABX 5 Pair Armoured PIJF underground telephone cable

500

-

-

... More
Wall mounted telephone socket

4

-

-

... More
20 mm ISI marked GI conduit along with all fittings & fixtures likeTees, bends, junction boxes, etc for installation of various fire detectors in building

500

-

-

... More
Testing Kit/Aerosol cans for Mutisensor detectors including one set of Fibreglass Telescopic Extension Pole 4.5 metres, Universal Re moval Tool, Aerosol Smoke Dispenser, Protective Carrying / Storage Bag

1

-

-

... More
Portable Gas Detector with controller, audio-visual alarm and suitable (intrisically safe) for hazardous area classified as classifi cation Class I, Div. I Group C&D as per API-RP-500 as per tender specification

1

-

-

... More
Workstation grade Machine for Programming Terminal- PLC/ Programming Terminal RTU/ SCADA Client Application/ SCADA Enginering Termin al/ SIC Terminal/ LDS Client Application

1

-

-

... More
23" DISPLAY Supply of 23" Display Monitor as per tender specifications.

1

-

-

... More
Group-B : Services (Chittoor Pump station)

-

-

-

... More
Erection, testing & commissioning of 6 Loop Fire Alarm & Detection System comprising of addressable Fire Alarm Panel, addressable de tectors of various types such as multisensor detectors, rate of rise heat detectors, manual call points, hooters, etc including FM20 0/ CO2 release system for control building consisting of Control room, Equipment room, MCC room, transformer room, VFD roomand other office /workshop rooms etc. and pumping sheds, piping area energizing & testing of the complete system with simulation and also de monstration of working of the complete system,commissioning of the complete system including the cost of all materials, labour, cons umables, equipments tools & tackles as per the specifications & instructions of Site Engineer / EIC.

1

-

-

... More
Supervision, erection, testing & commissioning of SIL rated LEL detector panel, including termination of power & signalling cables, wiring of hydrocarbon detectors, including all interfacing with PLC system etc making all jobs complete as per drawings / specificat ions and acceptance of the system by Owner. This includes supply of all labour, consumables, tools,services rendered etc

1

-

-

... More
Installation, testing & commissioning of Multi Sensor Detectors & isolators,laying of signalling cables (through conduit/ clamping o n wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with existing Fire Alar m panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all r espects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings , International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, mat erial etc

225

-

-

... More
Installation, testing & commissioning of Rate of Rise Heat Detectors for safe area & hazardous area,laying of signalling cables (thr ough conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with existing Fire Alarm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to co mplete the work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, material etc

15

-

-

... More
Installation, testing & commissioning of Response Indicators & Monitor modules,laying of signalling cables (through conduit/ clampin g on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with existing Fire A larm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in al l respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawi ngs, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, material etc

115

-

-

... More
Installation, testing & commissioning of Beacons / Hooters / Horn / Strobe (for safe area),laying of signalling cables (through cond uit/ clamping on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with exi sting Fire Alarm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete th e work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifica tions, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, material etc

20

-

-

... More
Installation, testing & commissioning of Manual Call Point (for safe area),laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with existing Fire Alarm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all re spects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, mate rial etc

20

-

-

... More
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres inclu ding shoring, strutting etc. (if necessary), backfilling the trench with excavated earth, as directed by Site Engineer, including all labour and materials complete as per drawings, specification and directions of Site Engineer.

200

-

-

... More
WBM ROAD / CONCRETE BREAKING: WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) as per specifications and direction of the Site Engineer, job complete in all respects including the cost of labour, tools, materials, load, lift hire cha rges of equipments, if any.

20

-

-

... More
CABLE LAYING: Laying of armoured / unarmoured Cables having outer diameter upto 20 mm (control / signalling/ Triad/ LT cable etc.) and installation / pulling of telephone cables of all type in trenches, in cable racks, in trays, in protective pipes, poles, col umns, in conduits, in panels, in buildings, walls, ceilings, and on structures etc.; including the supply and installation of all re quired materials such as fixing clamps, screws, cable straps, tags etc. as required (other than the supply of the conduits, cab les, pipes, cable racks, trays, poles, structures and panels) complete in all respect,as per specifications,drawings and directi ons of the SiteEngineer, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths

4100

-

-

... More
CABLE LAYING: Laying of armoured / unarmoured Cables having outer diameter between 20 mm to 30 mm (control / signalling/ Triad/ LT cable etc.) and installation / pulling of telephone cables of all type in trenches, in cable racks, in trays, in protective pipes , poles, columns, in conduits, in panels, in buildings, walls, ceilings, and on structures etc.; including the supply and installati on of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than the supply of the c onduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect,as per specifications,drawings and directions of the SiteEngineer, including cost of all labour, tools, consumable materials etc. and cutting the cables in requi red lengths

1050

-

-

... More
PLC and SCADA Modifications/Creation in the Control System HMI graphics & logic for the Control System including development/ modifi cation of new database, tags, PLC logic and all related jobs for inclusion of upcoming facilities at respective stations. Work inclu des Modification/Development of MMI graphics and uploading of the same in the existing workstations, engineering cum programming ter minal etc. as per the scope of the work and specifications to complete the job in all respects for incorporation of upcoming facilit ies as per the specifications, drawings and directions of the Site Engineer and submission of "As built" documentation. The work als o includes providing data to the SCADA vendor and assisting the same for incorporation of the changes in the SCADA.

1

-

-

... More
Laying of unarmoured signal cable through GI pipe / wall / tray etc for interfacing of various type of detectors e.g. multi sensor, ROR, UV/ IR flame detector, response indicator, hooters, beacons etc

1000

-

-

... More
Clamping / fixing of GI pipe on wall/roof/cable trench etc.

500

-

-

... More
Dismantling of Existing F&G system including removal of cables, Gas release panels, fire supression system etc.

1

-

-

... More
Training on the supplied F&G system as per the tender specifications

1

-

-

... More
Group-B : Composite (Chittoor Pump station)

-

-

-

... More
Installation of explosion proof / flame proof junction boxes for marshalling of control / signalling cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the require d materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Junction Boxes) complete i n all respects as per specifications, approved drawings and direction of EIC / Site Engineerincluding all labour, tools, materials, glanding, ferruling etc.complete in all respects.

5

-

-

... More
Installation of Infrared Hydrocarbon detectors (Point type / Open path type), terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, p ainting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respects as per specifications.

1

-

-

... More
Installation of UV/IR Flame Detectors, terminating the cables at field and control panel end, connecting to earthing grid by supplyi ng and installing all the required materialssuch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply o f the UV/IR Flame detector) complete in all respect as per specifications.

6

-

-

... More
Installation of Explosion Proof & Weather Proof Manual Call Point/ Hooters/ Beacons/ Telephone instrument in Hazardous area, termina ting the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materialssu ch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Manual Call Point/ Hooter/ Beacon) compl ete in all respect as per specifications.

25

-

-

... More
Supply & installation of miscelleneous installation material such as junction / terminal boxes for signal cable looping, surge prote ction devices, all types of cable glands, PVC conduit, clamping , fixing material and other installtion material, minor civil repair related to installation of detectors/laying of conduit & cables as per site requirement to complete the job in every respect

1

-

-

... More
"FM 200 based clean agent Fire suppression system: Supply, installation, testing & commissioning of FM 200 gas based clean agent Fir e Suppression System complete as per NFPA 2001 to complete the work in all respects inclusive of supply of all consumables, cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC a) FM 200 based clean agent cylinders (minimum 80 l capacity) in configuration of set of two banks (1 set = 1 main & 1 standby cylin der) complete with weighing device, safety valve and all accessories."

1

-

-

... More
"FM 200 based clean agent Fire suppression system: Supply, installation, testing & commissioning of FM 200 gas based clean agent Fir e Suppression System complete as per NFPA 2001 to complete the work in all respects inclusive of supply of all consumables, cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC a)FM 200 based clean agent cylinders (min 34 L capacity) in configuration of set of two banks (1 set = 1-main & 1 -standby cyliner) complete withsafety valve and all accessories."

2

-

-

... More
FM 200 based clean agent filled in cylinders

154

-

-

... More
All sizes of piping for FM 200 clean agent dispersion complete with nozzles, manifold , all type of hoses, etc to complete the work in all respect

200

-

-

... More
Supply , installation & interfacing of Gas release panel with Fire alarm panel to achieve the functionality of clean agent dispersio n

3

-

-

... More
Group-A : Comprehensive AMC (Chennai Pump Station)

-

-

-

... More
CAMC for 1st Year

1

-

-

... More
CAMC for 2nd Year

1

-

-

... More
CAMC for 3rd Year

1

-

-

... More
CAMC for 4th Year

1

-

-

... More
CAMC for 5th Year

1

-

-

... More
Group-B : Comprehensive AMC (Chittoor Pump station)

-

-

-

... More
CAMC for 1st Year

1

-

-

... More
CAMC for 2nd Year

1

-

-

... More
CAMC for 3rd Year

1

-

-

... More
CAMC for 4th Year

1

-

-

... More
CAMC for 5th Year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.