Indian Oil Corporation Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indian Oil Corporation Limited - IOCL Tender

Works
Telecommunication Services
Eprocure
Opening Date29 Apr 2019
Closing Date2 Jul 2019
Tender AmountRefer Documents 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Continued .. The cost of such material shall be as determined by the Engineer-in-Charge plus an additional charge of 15% of the cost of material shall also be levied. The decision of the Engineer-in-Charge, as to the cost of the material, shall be final and binding on the Contractor. VI) In the course of hydrostatic testing of the mainline section, if any defective portion/ pipe/ work is found to be due to a defect in the pipe attributable to the Owner, the Owner shall supply the additional necessary pipes at Owner issue point required for the work free of cost to the Contractor, but the Contractor shall supply all other materials and inputs at his own cost for replacement of pipe section. The Contractor shall be paid a lump sum amount for each such failure (refer relevant clause of Special Conditions of Contract of the tender documents) for the work involved in locating & identifying the defects in the mainline and in their repair/rectification as per the specification. Failure in one or more pipes in a section during a single pressurization cycle shall be considered as a single failure for the purpose of compensation for hydrostatic test failure on account of manufacturing defect. VII) Installation of the hot-pulled bends in Mainline, including cutting beveling of pipes, fitment etc., shall be inclusive in the Mainline rate. Payment for fabrication of hot-pulled induction bends, as per specifications, shall be done separately as per relevant item of SOR. The hot-pulled bends shall be coated at site with PU coating. The cost of the same shall be deemed to be included in this item for Mainline laying.

-

-

-

... More
24" OD Pipe Laying

69900

419260200

5998

... More
14" OD Pipe Laying

31820

110733600

3480

... More
Execution of road/other crossing by Shallow Horizontal Directional Drilling (HDD) technique including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document complete in all respect as per the instructions of the Engineer – in – charge /Site engineer.

-

-

-

... More
24" OD

220

5284400

24020

... More
14" OD

30

420360

14012

... More
CASED CROSSING-WITHOUT OFC DUCT,, Laying cased crossings, by auger boring & jacking method, using casing pipes according to drawings, specification(s) and providing all works, labour, inputs and materials/ consumables necessary to perform and complete the works in all respect in accordance with the contract, including collecting the pipes and other Owner-supplied materials from Owner’s issue point and loading, transporting them to site, setting out the works, aligning and welding the casing and carrier pipes, 100% radiography of weld joints of carrier pipes, field joint coating, holiday detection & repair of coating, applying atleast 2(two) coats of bitumastic paint over coat of suitable primer over casing pipe and two component epoxy coating for internal surface of casing pipe, excavating/ trenching and/or boring in all kinds of soil, including rocky strata if any, inserting the casing pipe into the bore, pre-hydrostatic testing of the carrier pipe and replacement / rectification of defects / pipes, installation of approved type of insulators throughout the cased section on the carrier pipe, carefully inserting the carrier pipe inside casing pipe by jacking/ pushing method, taking care not to damage the insulators, sealing the ends of the casing pipe with approved heat shrinkable wraparound type end seal, fixing of vent pipes at the ends of the casing pipe, priming and applying two coats of coal-tar based epoxy paint on underground portion of vent pipes, measuring final resistance between carrier pipe and casing, and doing preparation work necessary to produce correct resistance, applying one coat of primer and two coats of epoxy paint to all exposed and overground fittings & piping, proper compaction of backfill below carrier pipe at either ends, independently supporting the carrier pipe outside each end of the casing pipe by suitable RCC supports with neoprene rubber sheet below the carrier pipe, and strengthening with sand bags and proper compaction of earth below pipe, to prevent differential settlement of carrier pipe and damage to insulators, final clean-up and restoration of the site and disposal of wastes and surplus in accordance with the contract and supply of all materials (other than those specifically undertaken to be supplied by the Owner under contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works, and all other acts, matters and things necessary to make the pipeline ready for commissioning in all respect, as per directions of Site Engineer/ Engineer-in-Charge.,,

-

-

-

... More
14" OD Carrier Pipe

50

1133000

22660

... More
Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all works ,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contract, including taking delivery and transportation of Owner-supplied coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position, arranging the required additional land for construction purpose, preparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting (both pre- & post-installation) and replacement of pipes/ defects, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering including installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing ""Band IT"" make stainless steel (SS) strips / clamps of 3/4"" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and final clean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Engineer-in-Charge. NOTE : I)Depending upon the site condition & location of each submerged crossing, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/ drain/ rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. II)Profile of drain / canal bed, ground & top of laid pipe shall be established jointly in presence of Owner both before and after laying the crossing, by taking levels with reference to nearby permanent structure. III)The banks of the crossing shall be stabilised and suitable brick/ stone masonry bank protection works shall be carried out for the entire ROW width to prevent bank erosion leading to exposure of the pipeline. The procedure for such measures shall be submitted for Owner's approval prior to execution. IV)Concrete sheathing work for submerged crossings shall be paid for separately under relevant item of Schedule of Rates."

-

-

-

... More
Submerged crossings: 30" OD Carrier Pipe "Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all works ,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contract, including taking delivery and transportation of Owner-supplied coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position, arranging the required additional land for construction purpose, preparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting (both pre- & post-installation) and replacement of pipes/ defects, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering including installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing ""Band IT"" make stainless steel (SS) strips / clamps of 3/4"" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and final clean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Engineer-in-Charge. NOTE : I)Depending upon the site condition & location of each submerged crossing, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/ drain/ rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. II)Profile of drain / canal bed, ground & top of laid pipe shall be established jointly in presence of Owner both before and after laying the crossing, by taking levels with reference to nearby permanent structure. III)The banks of the crossing shall be stabilised and suitable brick/ stone masonry bank protection works shall be carried out for the entire ROW width to prevent bank erosion leading to exposure of the pipeline. The procedure for such measures shall be submitted for Owner's approval prior to execution. IV)Concrete sheathing work for submerged crossings shall be paid for separately under relevant item of Schedule of Rates."

1150

31991850

27819

... More
14" OD Carrier Pipe

1530

24841080

16236

... More
Mainline IP 101 IP102 No ITC 2 TAMILNADU

-

-

-

... More
I MAINLINE WORKS

-

-

-

... More
Laying pre-coated pipes in Marshy areas with concrete sheathing including providing all equipment, works,labour, inputs and materials/consumable necessary to perform and complete the work in all respects, submission of construction procedure for Owner's approval, arranging the required additional land for construction purpose, preparation of site including dewatering, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting testing and replacement of pipes/ defects, excavation of the trench to required depth in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, and laying of the pipeline in approved trench, backfilling and final clean-up, stabilisation of the excavated banks, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the work in all respects according to the contract.

-

-

-

... More
24" OD

5060

100688940

19899

... More
Concrete Sheathing / Coating (100 mm thk

-

-

-

... More
Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) of 100 mm thick in two layers using specified (approved) wire mesh reinforcement as per approved drawing and technical specifications, including supply of cement, steel wire mesh, aggregate, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, testing of concrete coated pipes etc. and as per direction of Engineer-in-Charge. HNOTE:/ I) Payment shall be made for the actual length of pipe coated with concrete. Ends of pipe left uncoated/ shall not be considered in the concrete coating length II) The rates shall include compensation for additional hardship caused in handling and/ or lowering the pipe with concrete coating. The above item shall be executed at the discretion and directions of Engineer-in-Charge. III) The rates shall include the concrete sheathing / coating over weld joints in order to arrive at continuously concrete coated pipeline. This weld joint concrete sheathing / coating shall be applied after the hydrostatic pre-test. "

6570

88603020

13486

... More
Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) of 50mm thick in two layers using specified (approved) wire mesh reinforcement as per approved dr awing and technical specifications, including supply of cement, steel wire mesh, aggregate, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, testing of concrete coated pipes etc. and as per direction of Engineer-in-Charge. NOTE: I) Payment shall be made for the actual length of pipe coated with concrete. Ends of pipe left uncoated/ shall not be considered in the concrete coating length II) The rates shall include compensation for additional hardship caused in handling and/ or lowering the pipe with concrete coating. The above item shall be executed at the discretion and directions of Engineer-in-Charge. III) The rates shall include the concrete sheathing / coating over weld joints in order to arrive at continuously concrete coated pipeline. This weld joint concrete sheathing / coating shall be applied after the hydrostatic pre-test.

1230

4843740

3938

... More
Rock Trenching: Extra for rock trenching for Mainline laying (covered under relevant item of this SOR) as classified by the Engineer-in-Charge and performed by pneumatic tools or by drilling and blasting or by chiselling out including cost of all equipment, materials, labour, consumables & inputs to complete the work (excluding sand padding around mainline pipe which shall be paid separately) as per specifications, approved procedure and instructions of Engineer-in-Charge. Note: 1.Payment shall be made for rock actually excavated at site or calculated based on the trench dimensions stipulated in the specifications / drawings, whichever is less. 2.Item shall be operated under specific instructions from Engineer-in-Charge. 3.Controlled Blasting operation shall be carried out only by authorized and trained / skilled manpower, as per approved procedure, and taking due care & precaution to adjoining property, people, livestock etc., with due approval from Engineer-in-Charge 4.Sand padding around mainline pipe shall be paid separately as per relevant item in SOR 5. Additional 150 mm depth of excavation to be carried out in rocky area (for pipe trench) to accommodate sand padding

-

-

-

... More
Extra for rock trenching for mainline la

2000

1958000

979

... More
Sand Padding (In Hard Rocky Area)

-

-

-

... More
14" OD

1220

1073600

880

... More
SAND PADDING (AT SEISMIC FAULT LOCATIONS),, Supplying, providing and filling fine sand in trenches at Seismic Fault location crossing or running parallel to pipeline (including additional 500 mm deep & 200/300 mm wide trenching) around mainline pipe for providing a minimum padding thickness of 500 mm on top as well as at bottom of the mainline pipe(for the complete trench width).as per direction of Engineer-in-Charge.,,

-

-

-

... More
24" OD

1000

3850000

3850

... More
14" OD

1000

2310000

2310

... More
SAND PADDING ( IN OTHER AREAS) Supplying, providing and filling fine sand in trenches in stretches other than normal soil and hard rock / boulder stretch (including additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bottom of the mainline pipe for the complete specified trench width NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be included in this item itself

-

-

-

... More
24" OD

500

632500

1265

... More
14" OD

50

36850

737

... More
Rock shield

-

-

-

... More
14" OD

1220

577060

473

... More
"HDD INSTALLATION (CARRIER PIPE & OFC DUCT) Design, detailed engineering, installation of pipeline and OFC conduit at specified minimum depth across water bodies (canal/ drain/ nalla, marshy area etc.)/ Highway / congested areas / other busy roads etc. by Horizontal Directional Drilling (HDD) method; Complete work for the crossing (between the limits, as indicated in the approved drawing and as per the approved procedure & design) including mobilisation & de-mobilisation at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to the following works and in accordance with the specifications, drawings, as per the provisions of the contract document and instructions of the Engineer-in-Charge - Interpretation of data of hydrological/ geo-technical surveys furnished by the Owner (if any), carrying out topographic survey, carrying out additional surveys as required for collecting data relevant to design and execution of the crossing, performing all engineering & design calculations including preparation of all necessary construction drawings for approval of the Owner as per the provisions of contract document, preparation of detailed construction method statement and design analysis; - Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position; - Repair of pipe and coating damages occurred, if any, during transportation; - Complete site preparation including arranging of additional required land beyond ROW provided by Owner, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc.; - Pre-construction surveys and collection of all necessary data related to site, underground utilities etc.; - String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced radiography inspector) and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the welds and re-testing etc.; - -Coating of the field joints of the pipe string to be installed by HDD method with DIRAX heat shrink sleeves of M/s Seal for life make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings; - Repair of all coating damages in the pipe section to be laid by HDD method by full encirclement sleeves using suitable cut sections of approved quality of DIRAX heat shrink sleeves of M/s Seal for life make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make; - Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC - Supply & fixing of easy to install heat shrinkable duct end caps for HDPE duct for OFC - Carrying out air cleaning, gauge pigging and pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retesting etc.; - Installation of the carrier pipeline and OFC conduit below the water body (canal/ drain/ nalla/ marshy area etc.)/ Highway/ congested area/busy road etc., as a bundle by single horizontal directional drilling operation to the correct profile as per the approved procedure, design & profiles using HDD Rig of adequate/ approved capacity, suitable drill pipe, proper drilling fluid including additives (suiting soil & groundwater conditions etc.), drill bit, reamer and approved tracking system in different soil strata at site including rock; - Carrying out post-installation hydrostatic testing; - Carrying out post-installation coating survey as per approved procedure - Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc.; - Transportation of surplus Owner-supplied pipes & OFC cable to the designated stockpile location of the Owner; - Preparation of As-built drawings and other records etc.; - All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works; Note: 1) Payment shall be released in stages as stipulated in the Special Conditions of Contract; 2) Length of HDD for payment purpose shall be considered as length between hook-up points with mainline pipe at normal depth at both sides of HDD. 3) Maximum length of single length of HDD crossing shall be approximately 500 meters"" 4) The length and number of HDD crossings may vary as per site requirement during execution. "

-

-

-

... More
For Normal Soil Condition-24" OD

900

39303000

43670

... More
For Rocky Soil Condition-24" OD

230

20796600

90420

... More
For Normal Soil Condition-14" OD

1070

27306400

25520

... More
For Rocky Soil Condition-14" OD

270

14256000

52800

... More
Pipeline MArkers Supply of all materials necessary for fabrication and installation of kilometre posts, direction markers and warning signs at the locations as per specifications, excavating & grouting in cement concrete 1:3:6, and all other works necessary for fabrication & installation of the markers including cleaning, priming & applying two coats of coal tar based epoxy paint on underground portions, supply and application of one coat of primer and two coats of epoxy paint of approved colour and quality on overground portion, stencil letter cutting for number, direction, chainage etc. and restoration of site to original condition and all other acts, deeds, matters and things and work, labour, inputs and materials/ consumables necessary to perform and complete the work in all respects as per approved drawing & specifications and as per direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Kilometer post

120

897600

7480

... More
Direction marker

685

4965565

7249

... More
Warning sign

220

1906960

8668

... More
Boundary Pillars Providing and installing RCC (1:1.5:3) boundary pillars as per drawings on both edges of the ROW at 250 metres interval and at every turning point and/or as directed, including supply of all materials necessary for the fabrication of the pillars, casting and inscribing the pillars, excavation of earth, fixing the pillars & backfilling, applying two coats of oil paint over one coat of cement based primer on exposed surface and work, labour, inputs & materials/ consumables necessary to perform and complete the work in all respect under the contract and as per directions of Site Engineer.

1410

2326500

1650

... More
AIR DRYING (OPTIONAL) Carrying out air drying of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
24" OD

78

9138558

117161

... More
14" OD

35

1395625

39875

... More
NITROGEN PURGING (OPTIONAL) Carrying out Nitrogen Purging of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
24" OD

78

7160868

91806

... More
14" OD

35

1093400

31240

... More
H"ELECTRONIC GEOMETRY PIGGING (EGP) / CALLIPER SURVEY (INCLUDING MAGNETIC PIGGING)/ Mobilisation/ demobilisation of pigging tools, tackles, consumables, accessories and personnel by contractor at work site including magnetic pig, electronic geometry pig, pig tracking device, preparation and cleaning of the complete mainline / Mainline sections including HDD sections under this tender by running series of pigs for cleaning the line from debris, water & making it dry for launching calliper pigs, running of magnetic pig for cleaning of ferrous residue, launching and receiving the electronic & standard calliper pigs, including pig tracking at 2 to 3 km interval, data retrieval, interpretation of data and submission of reports in the form acceptable to the Owner, including rectification of defects observed from calliper survey, including supply of all labour, materials, equipment & instruments, calliper pigs, fabrication of launching & receiving barrels, all complete for ascertaining the geometry of the pipeline. "

-

-

-

... More
24" OD

78

4185324

53658

... More
14" OD

35

1095710

31306

... More
Installation of MOVs/Sectionalising Valve(SVs) on Mainline "Taking delivery of MOVs for mainline from Owner's stockpile/ godown, preparation of pup pieces of specified length from owner supplied pipes of higher wall thickness, welding of pup pieces to both sides of valves, providing instrument tappings in MOVs, hydrostatically testing the valves & installing at designated locations on the mainline in accordance with the specifications and drawings, welding & 100% radiography of weld joints, repair of weld joints etc., complete in all respect including all works and material in foundation, RCC underground valve supports etc., including PU Coating of underground portions and painting of overground portions / valve enclosure etc. with aluminium paint over a coat of primer, and including supply of all materials (other than those specifically undertaken to be supplied by the Owner), consumables & inputs complete as per specifications, drawings & instructions of Site Engineer / Engineer-in-Charge. "

-

-

-

... More
24" OD

5

967450

193490

... More
14" OD

2

225742

112871

... More
"Carrying out tieing-in and hook-up of mainline pipe with the HDD sections of pipeline (executed by other agency) (Optional) on either side of the HDD pipe section , including excavation/ trenching in all kinds of soil including rock, cutting of pipe, making field bends out of pre-tested pipes to match the site requirement, welding, carrying out 100% radiography, field joint coating, holiday detection, repair of damaged coating, backfilling and making through the pipeline etc. complete in all respects. Note: This item shall be operated under specific instructions of Engineer-in-Charge."

-

-

-

... More
24" OD

11

5127254

466114

... More
14" OD

1

271909

271909

... More
Fabrication of Hot pulled bends Taking delivery and transportation of bare pipes from owner's stockpile, transportation, unloading the pipes at manufacturer's works and fabrication of Long Radius (R=6D) Hot pulled induction bends having tangent length of approximately 1000m at both ends as per specification and delivery of hot pulled bends to site including visual examination, manual U.T. on the entire weld seam, bevelling of ends as per API 5L, supply of all materials, consumables, labour etc. as per specifications and direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
24" OD

2

569140

284570

... More
14" OD

1

166100

166100

... More
Commissioning Assistance (for R-LNG Pipeline) Commissioning assistance: Supply of all materials, consumable, providing all equipemnet & resource for the complete activitiy of commissioning of R-LNG pipeline including mainline & station Pipeline with proper pressurization of mainline and station piping with Nitrogen, bacth pigging followed by vaporised R-LNG and effective line fill by pressurization of line fill with R-LNG as per approved procedure and specification requirement i ncluding providing expert services for vetting of commissioning procedure and presence of experts to guide & monitor the complete commissioning activities with proper satisfaction to EIC. Note: This Item shall be operated with prior permission from EIC.

-

-

-

... More
24" OD

78

1643928

21076

... More
14" OD

35

430430

12298

... More
IP 101 IP102 Civil Comp No ITC TAMILNADU

-

-

-

... More
I CIVIL Work

-

-

-

... More
EARTHWORK :

-

-

-

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth up to 50m lead and lift up to 1.5 m, as directed by the Engineer-in-Charge : a) All kinds of soil

27370

1376711

50.3

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by the Engineer-in-Charge. a) All kinds of soil

11480

1372204

119.53

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

8408

1003410

119.34

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.,, -All kinds of soil.,,

116

5696

49.11

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

168

146319

870.95

... More
Supplying chemical emulsion in sealed containers including delivery as specified. a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

485

85587

176.47

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

849

13533

15.94

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

3894

487411

125.17

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of existing masonry using chemical emulsion @ 1 litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

864

15621

18.08

... More
Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by site Engineer complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.

1039

146883

141.37

... More
Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor's own borrow areas including royalty, with all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thickness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.

31485

11289891

358.58

... More
CONCRETE WORK :

-

-

-

... More
CEMENT CONCRETE (CAST IN-SITU) :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size)

115

537713

4675.77

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 40 mm nominal size)

55

251298

4569.06

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size)

733

3115110

4249.81

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

399

170528

427.39

... More
Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm down size) mixed with approved brand of water proofing compound @ 1Kg/50 Kg bag of cement, in roof grading, coping, in bed concrete etc. at all heights & depths, including providing centering and shuttering, scaffolding, watering, curing, vibrating, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer.

48

328960

6853.34

... More
Providing and laying 40 mm thick CC 1:2:4 Damp Proof Course with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone chips 6 mm down size) laid to proper level & line including providing shuttering, applying two coats of bitumen applied @ 1.50 Kg/sqm and spreading an even layer of coarse sand over hot bitumen, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer.

1451

755318

520.55

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
CAST IN-SITU :

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III): 3 graded stone aggregate 20 mm nominal size)

2438

14380372

5898.43

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

14

76696

5478.3

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size)

1073

7276485

6781.44

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 Degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size)

456

3198361

7013.95

... More
FORM WORK :

-

-

-

... More
Centering and shuttering including strut

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

2359

434197

184.06

... More
Suspended floors, roofs, landings, balconies and access platform

1190

476916

400.77

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

5929

1929415

325.42

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

9073

4028321

443.99

... More
STEEL REINFORCEMENT :

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

403822

21689279

53.71

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more

261541

14047367

53.71

... More
BRICK WORK :

-

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)

1447

6525058

4509.37

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

2108

11168563

5298.18

... More
MARBLE & GRANITE WORK :

-

-

-

... More
Granite of any colour and shade : -Area of slab up to 0.50 sqm

37

117698

3181.04

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. :,,,, -Polished granite stone slab- Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

95

264851

2787.91

... More
STEEL WORK :

-

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :,,,, -35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws,,

2

4724

2362.04

... More
Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:,,,, -35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws,,

20

29604

1480.22

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top cover of required thickness for rolling shutters.,,,, -80 x 1.25 mm M.S. laths with 1.25 mm thick top cover,,

50

109900

2198

... More
Providing and fixing ball bearing for rolling shutters.

36

12958

359.96

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia. M.S. bar bent to shape as per standard drawing.

46

5679

123.47

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless Steel (Grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.

5

4942

988.44

... More
Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer#s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work).

52.84

5347360

101199.1

... More
Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the body of the post), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutting and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.,,,,

7600

3394084

446.59

... More
Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lifting arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.,,,,

144

615317

4273.04

... More
Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of high carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equivalent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 microns. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regular intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed condition should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.,,,,

1900

738226

388.54

... More
FLOORING :

-

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per the direction of Engineer-in-Charge.,,,, -In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand),, Acid and alkali resistant tile

146

148718

1018.62

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per the direction of Engineer-in-Charge.,,,, -In dado/ skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand),, Acid and alkali resistant tile

243

263725

1085.29

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :,,,, -25 mm thick,,

344

378073

1099.05

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. ,,,,

146

171558

1175.06

... More
Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete.,,,,

199

140657

706.82

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of first quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing the joints with white cement and matching pigment, etc. complete.,,,,

45

29396

653.25

... More
Providing and fixing first quality ceramic glazed floor tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete. ,,,,

19

11904

626.54

... More
Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer.

1907

1031973

541.15

... More
Providing and laying 52 mm thick cement concrete flooring with metallic hardner, under layer of 37 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer of 15 mm thick metallic concrete hardner consisting of mix 1:2 (1 cement : 2 stone aggregate 6 mm nominal size) by volume with which metallic hardening compound such as IRONITE NO. 1 of IRONITE CO. OF INDIA LTD. or aproved equivalent mixed in the ratio 4:1 (4 parts of cement : 1 part of metallic floor hardening compound of approval quality) by weight, inclusive of cost of finishing, labour, material, equipment, etc. as per specifications and directions of the Engineer-in-Charge.,,,,

263

225056

855.73

... More
ROOFING & CEILING :

-

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase

427

62000

145.2

... More
Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

38

6765

178.03

... More
Providing and fixing 100 mm diameter and 60 cm long rainwater spout in cement mortar 1:4 (1 cement : 4 fine sand) :,,,, -Stoneware Spout,,

2

172

86.22

... More
Providing and fixing on wall face Unplasticised Rigid PVC (UPVC) rainwater pipes conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion: (i) Single socketed pipes : 110 mm diameter

757

169795

224.3

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Coupler :110 mm

74

7209

97.42

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Single Push-fit Coupler ::110 mm

74

6640

89.73

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Bend 87.5 Degrees :110 mm

74

7942

107.33

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Shoe (Plain) :110 mm

74

6882

93

... More
Providing and fixing LUXALON 75C & 225C un-perforated Aluminium panel coloured ceiling manufactured by M/s. HUNTER DOUGLAS INDIA or any other approved equivalent brand, each panel consisting of 75/225 mm wide x 15.5 mm deep and 0.5 mm thick with bevel edged panel made from enamelled corrosion resistance aluminium alloy AA-5050 (Al.Mg), each panel to abut each other with a narrow 'V' groove, clipping with a baked enamelled aluminium panel carrier of 32 mm wide x 39 mm deep x 0.95 mm thick in standard length of 5 metres made of double baked enamelled aluminium alloy AA-5050 (Al.Mg) black with cutouts to hold the panels in a module of 75 mm closed at a distance of 1.25 metre, each panel carrier suspended by means of G.I. suspension rod 4 mm diameter and a galvanised supsension spring clip at a distance of 1.7 metre centre to centre, making openings for light fittings etc. with suitable peimeter framing all complete as per manufacturer's recommendation and directions of the Engineer-in-Charge. (Note: Measurement shall be made wall to wall without any deduction for openings, for payment purpose).

30

152964

5098.81

... More
FINISHING

-

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :,,,, -1:4 (1 cement : 4 fine sand),,

350

66514

190.04

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :,,,, -1:6 (1 cement : 6 fine sand),,

7341

1290254

175.76

... More
CEMENT PLASTER (IN COARSE SAND) : 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement : 6 coarse sand)

15722

2903538

184.68

... More
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)

5937

810222

136.47

... More
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.,,,,

3634

665094

183.02

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer

7649

268250

35.07

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

5772

825222

142.97

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :,,,, -Two or more coats on new work,,

18895

1514245

80.14

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

7649

634102

82.9

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. -Two coats

72

3392

47.12

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.,,,, - two coats.

7577

531375

70.13

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.,,,, - two coats

832

56060

67.38

... More
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

90

6406

71.18

... More
Providing grooves of uniform size 12x12 mm and up to 15x15 mm in plaster as per approved pattern using wooden battens, nail to the under layer including removal of wooden battens repair to the edges of panels and finishing the groove complete as per directions of the Engineer-in-Charge.

1731

105348

60.86

... More
Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.

1943

362000

186.31

... More
Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations laid over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

303

448218

1479.27

... More
Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and directions of the Engineer-in-Charge.

236

264924

1122.56

... More
ROAD WORK :

-

-

-

... More
Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead up to 50 metres.

1050

89785

85.51

... More
Supplying and stacking at site :

-

-

-

... More
90 mm to 45 mm size stone aggregate

210

266265

1267.93

... More
53 mm to 22.4 mm size stone aggregate

158

231250

1463.61

... More
Stone screening 13.2 mm nominal size (Type A)

28

40007

1428.83

... More
Stone screening 11.2 mm nominal size (Type B)

28

38850

1387.5

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.

368

156841

426.2

... More
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.,,,,

79

412629

5223.16

... More
Providing and laying design mix cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately. (2) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately]. Cement concrete prepared with batch mixing machine

105

686885

6541.77

... More
Providing and fixing in position pre-moulded joint filler in expansion joints.,,,, payment shall be made for PER CM DEPTH PER CM WIDTH PER M LENGTH

9460

19771

2.09

... More
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of the Engineer-in-Charge and accordance with applicable specifications.

6

2227

371.3

... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of the Engineer-in-Charge.

315

184057

584.31

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of the Engineer-in-Charge.,,,, -60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern.,,

620

444905

717.59

... More
Supplying & fixing in position pre-cast cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate) kerb stone of size 450 mm high, 150 mm average thick & 600 mm long, each stone joined with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) over a base of cement mortar, including excavation, bed concrete 300 wide & 100 thick in cement concrete 1:3:6 concrete, painting of exposd surfaces etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of Site Engineer.

420

351149

836.07

... More
Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE for reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg/metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, scales, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fasteners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and direction of the Eng ineer-in-Charge.,,,,

5

11075

2215.16

... More
PILE WORK :

-

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [Notes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machine shall not be used] : 450 mm diameter piles

3179

4514656

1420.15

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynamic method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-In-Charge.] :,, Single pile up to 50 tonne Safe Capacity :,, Initial Test (Test Load 2.5 times the Safe Capacity),,

3

109786

36595.55

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynamic method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-In-Charge.] :,, Single pile up to 50 tonne Safe Capacity :,, Routine Test (Test Load 1.5 times the Safe Capacity)

3

49602

16534.13

... More
ALUMINIUM WORK :

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-In-Charge. (Glazing, paneling and dash fasteners to be paid for separately) : (a) For fixed portion : Powder coated aluminium (Minimum thickness of powder coating 50 micron)

362

132090

364.89

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-In-Charge. (Glazing, paneling and dash fasteners to be paid for separately) : (b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required. (Fittings shall be paid for separately) : Powder coated aluminium (Minimum thickness of powder coating 50 micron)

908

383366

422.21

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-In-Charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.50 mm thickness

246

234378

952.76

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-In-Charge. : With stainless steel cover plate minimum 1.25 mm thickness

64

124777

1949.65

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of the Engineer-In-Charge. Powder coated (Minimum thickness 50 micron) aluminium tubular handle bar

64

30933

483.33

... More
Providing and fixing 100 mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.

64

21804

340.69

... More
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated (Minimum thickness 50 micron) Aluminium

2

105

52.67

... More
Providing and fixing aluminium round shape handle of outer diameter 100 mm with SS screws etc. complete as per direction of the Engineer-In-Charge. Powder coated (Minimum thickness 50 micron) Aluminium

2

129

64.82

... More
Providing and fixing, on fixed glazing/ doors/ window panes, sun control film "HP NATURAL 35 SAFETY COMBINATION FILM-4Mil" of M/s. GARWARE or approved equivalent make and shade, all complete as per manufacturer's specification and as per instructions of the Engineer-in-Charge.

246

214194

870.71

... More
WATERPROOFING :

-

-

-

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. (b) Tear strength in longitudinal and transverse direction as 300/250N. (c) Softening point of membrane not less than 150°C. (d) Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick

1176

465496

395.83

... More
Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer.

1260

138020

109.54

... More
MISCELLANEOUS WORKS :

-

-

-

... More
Providing and making Construction/ Contraction joint by mechanically cutting 12mm x 25mm deep groove and filling with bituminous sealing compound including cleaning etc. complete as per drawing, specifications and directions of the Engineer-in-Charge.

189

88298

467.19

... More
Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm size (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

703

168495

239.68

... More
RAINWATER HARVESTING

-

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of the Engineer-In-Charge.,,,,

32

27996

874.89

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of the Engineer-In-Charge.,,,,

32

31523

985.12

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of the Engineer-In-Charge.,,,,

32

31523

985.12

... More
HORTICULTURE

-

-

-

... More
Supplying and filling good earth for lawns & in plantation area, in layers not exceeding 20 cm depth in one operation including removal of debris/ un-wanted material, consolidation, dressing, levelling and watering etc. complete as per direction of the Site Engineer/ Engineer-in-Charge. (Note : Volume of earth to be calculated for the payment shall be the volume of stacked earth after reduction by 20%).,, ,,

10125

5659267

558.94

... More
Supply, stacking and mixing sludge manure with earth in required proportion and spreading sludge manure in lawn inclusive of charges of all duties, royalty, cost of carriage etc. up to any distance. (Note: Sludge/ manure to be measured in stacks and will be reduced by 8% for payment).,,,,

10125

8180797

807.98

... More
Supply, stacking and mixing Cow Dung/ Neem oil cake/ Agro meal with earth in required proportion and spreading the mixture in lawn and or filling in specified areas inclusive of charges of all duties, royalty, cost of carriage etc. up to any distance. (Note: Cow Dung/ Neem oil cake/ Agro meal/ Manure shall be measured in stacks and will be reduced by 8% for payment).,,,,

10125

8209248

810.79

... More
Grassing with approved quality doob grass in rows of 7.5 cm apart in either direction, in lawns etc. including watering and maintenance of the lawn for 30 days or more till grass forms a thick free from weeds and fit for mowing including supply and filling good earth, if required, during maintenance period (Note: The good earth shall be paid separately under relevant item).,,,,

50625

15451762

305.22

... More
Digging holes and refilling the earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part earth : 1 part manure) including flooding with water, removal of rubbish and surplus earth (if any), spraying with insecticides complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of the Site Engineer. (Note: Cost of manure, sludge or extra good earth, if needed shall be paid separately under relevant item).,,,, Holes 0.6 metre deep and 0.6 metre diameter.,,

2400

988680

411.95

... More
Digging holes and refilling the earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part earth : 1 part manure) including flooding with water, removal of rubbish and surplus earth (if any), spraying with insecticides complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of the Site Engineer. (Note: Cost of manure, sludge or extra good earth, if needed shall be paid separately under relevant item).,,,, Holes 1.2 metre deep and 1.2 metre diameter.,,

50

36888

737.76

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m & lift up to 1.5 m complete. (Note: Cost of sludge, manure or extra earth shall be paid for seperately under relevant item).,,,,

45563

18769677

411.95

... More
Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days minimum complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of the Site Engineer.,,,,

800

358024

447.53

... More
SANITARY FITTINGS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.,,

10

32443

3244.38

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :,,,, One urinal basin with 5 litre white P.V.C. automatic flushing cistern,,

10

33159

3315.98

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :,,,, White Vitreous China Wash basin size 550x400 mm (Ref. Make: HINDWARE, Model: Cat No.-10010 or equivalent approved) with a pair of 15 mm C.P. brass pillar taps,,

1

1988

1988.46

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap,,

18

31044

1724.68

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :,,,, Flexible Pipe :,, 32 mm diameter

19

1320

69.52

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.,,,,

19

14748

776.24

... More
Providing and fixing toilet paper holder :,,,, C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent).,,

10

3657

365.7

... More
Providing and fixing soil, waste and vent pipes :,,,, Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989

3

2623

874.66

... More
Re-painting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff, etc. :,,,, 75 mm diameter pipe,,

45

644

14.33

... More
Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-Charge.,, ,, 2025 (25 mm OD) pipe,,

45

11295

251.01

... More
Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-Charge.,, ,, 2532 (32 mm OD) pipe,,

45

14923

331.63

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-In-Charge.,,,, 15 mm nominal outer dia pipes,,

45

6104

135.66

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-In-Charge.,,,, 20 mm nominal outer dia pipes,,

45

7684

170.77

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-In-Charge.,, 25 mm nominal outer dia pipes,,

11

2256

205.18

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of the Engineer-In-Charge.,,,, 15 mm nominal outer dia pipes,,

138

32243

233.65

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of the Engineer-In-Charge.,,,, 20 mm nominal outer dia pipes,,

135

36494

270.33

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of the Engineer-In-Charge.,,,, 25 mm nominal outer dia pipes,,

11

3482

316.59

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of the Engineer-In-Charge.,,,, 32 mm nominal outer dia pipes,,

10

2377

237.77

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of the Engineer-In-Charge.,, 40 mm nominal outer dia pipes,,

12

3657

304.77

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of the Engineer-In-Charge.,, 150 mm nominal outer dia pipes,,

63

144013

2285.93

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :,,,, 25 mm nominal bore,,

19

7721

406.37

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :,,,, 32 mm nominal bore,,

18

8553

475.22

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.,,,, Circular Tank,,

500

3440

6.88

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.,, Rectangular Tank,,

4500

30960

6.88

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.,,,, 15 mm nominal bore,,

18

9485

526.99

... More
Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. :,,,, Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0021 or approved equivelent),,

36

45703

1269.55

... More
Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. :,,,, Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0037 or approved equivelent),,

1

1327

1327.6

... More
Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.,,,, Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent),,

37

48532

1311.68

... More
Providing and fixing 15mm diameter C.P. brass stop cock with wall flange (Ref. Make: JAQUAR, Model: Cat. No. 0933 or approved equivalent), male end with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange etc. including cutting & making good the walls wherever required complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.,,,,

37

50229

1357.56

... More
Providing & fixing Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent).,,,,

10

24361

2436.12

... More
Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. :,, ,, Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc.,,

19

33158

1745.17

... More
Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. : C.P. brass double coat hook (Ref. Make: JAQUAR, Model: Cat. No. 1161 or approved equivalent).,,

19

16899

889.44

... More
DRAINAGE:

-

-

-

... More
Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :,,,, 150 mm diameter,,

155

48107

310.37

... More
Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :,, 200 mm diameter,,

135

54237

401.76

... More
Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 250 mm diameter,,

135

88720

657.19

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :,,,, 100x100 mm size P-type :,, With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5

37

56265

1520.69

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 150 mm dia. R.C.C. pipe,,

21

7108

338.51

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 250 mm dia. R.C.C. pipe,,

90

41172

457.47

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 300 mm dia. R.C.C. pipe,,

132

64958

492.11

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 450 mm dia. R.C.C. pipe,,

42

28735

684.19

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 600 mm dia. R.C.C. pipe,,

42

55686

1325.86

... More
Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :,,,, 1000 mm dia. R.C.C. pipe,,

21

49135

2339.79

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone-III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :,,,, Inside dimensions 455x610 mm and 45 cm deep for single pipeline :,, With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5

9

40803

4533.75

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone-III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :,,,, Inside dimensions 455x610 mm and 45 cm deep for single pipeline :,, With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5

1

5187

5187.95

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. :,,,, With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5,,

10

196270

19627.01

... More
Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coarse aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.,,,, -FOR 10 USERS

10

1059533

105953.37

... More
Constructing percolation pit of size 3.0m diameter and 2.0m deep, filled with 40 mm size brick ballast including providing suitable pre-cast RCC covers with lifting lugs, laying of 150mm diameter x 5.0m long U.P.V.C. pipe embedded in pit/ outlet pipe all complete as per specification and directions of the Engineer-in-Charge.,,,,

18

1219225

67734.77

... More
Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125mm C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floors, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.,,,,

37

50298

1359.43

... More
Providing and fixing 32mm diameter (Nominal Bore) brass ball valve of approved quality complete with high pressure copper floats, complete in all respects inclusive of cost of all materials, labour, tools, tackles, etc. complete as per specifications and directions of the Engineer-in-Charge.,,,,

10

50014

5001.44

... More
Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid over a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including making haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard design and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc., as per specifications of the Engineer-in-Charge.,,,,

503

796349

1583.2

... More
Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thick) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to drains inclusive of all labour, material, equipment, etc., all complete as per drawing and directions of the Engineer-in-Charge.,, 750mm x 750mm x depth up to 1000mm inner dimensions,,

9

119989

13332.18

... More
Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thick) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to drains inclusive of all labour, material, equipment, etc., all complete as per drawing and directions of the Engineer-in-Charge.,,,, 600mm x 600mm x depth up to 750mm inner dimensions,,

10

104794

10479.43

... More
IP 101 IP102 Composite ITC TAMILNADU

-

-

-

... More
I MECHANICAL WORK COMPOSI CSW

-

-

-

... More
Supply and Erection of Structural Steel:Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.

21

2004450

95450

... More
PU /liquid epoxy Coating of under ground piping: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.

410

779110

1900.27

... More
Painting: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. priming with one coat of primer and painting the surfaces with two coats as per specification, with approved materials, paints, brushes, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.

-

-

-

... More
Zinc Ethyl Slicate Primer

950

433599

456.42

... More
High Build EPOXY MIO

950

313063

329.54

... More
Isocynate Aliphatic Poly Urethene(PU)

950

397499

418.42

... More
Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping, The job includes cutting drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC. Note:- Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines.

-

-

-

... More
Up to 30 mm wide x 3 mm thick Copper strip

948

548181

578.25

... More
30 - 50 mm wide x 3 mm thick Copper strip

20

18561

928.08

... More
Medium Velocity Water Sprinkler System:Design, Detailed Engineering, supply, fabrication, erection/Installation and commissioning of complete medium velocity water sprinkler systems for Pump Shed, barrel area, filteration, metering and piping area at each location as per the details mentioned below:Medium Velocity Water Sprinkler System: Automatic Medium velocity water Sprinkler System for Pump Shed, barrel area, filteration, metering andand Piping Area:Design, detail engineeri ng, drawing and development of scheme for automatic medium velocity water sprinkler system for the equipment andpiping area including supply of all material like Deluge valve(Wet Type/ Dry Type), Spray nozzles, pressure switch, pressuer gauge, piping,valves, flanges, coupling, pipe fittings, brackets, clamps, fasteners, solenoid switches, S.S piping, strainers, alongwith all accessories asper the approved schemeat site, erection and installation of piping,cabling, equipments and instruments control panel etc, provision ofcompressed air/pneumatic piping from owner's compressed air headerlocated near compressor room for Dry Type Deluge Valve includingdismantling, breaking of road etc.as required for setting out of thesystem and making good the same,hooking up the system with the hydrantnetwork,sand blast cleaning, priming and painting (Zinc Ethyl SlicatePrimer,High Build EPOXY MIO, Isocynate Aliphatic Poly Urethene(PU) insignal red colour); internal coating with liquid epoxy, Carrying outall electrical and instrumentation works to enable auto actuation of the deluge valve and medium velocity water sprinkler system based onalarm signal from QB sensors/ gas detectors/ flame detectors. Carryingout the electronic integration of the system with the control panel andproviding alarm and automatic actuation of the deluge valves withmanual over-ride provision, testing & commissioning of the systemincluding cost of all labour, services, materials tools & tackles consumables, first operation & funrnishing of operation and maintenancemanuals on lumpsum basis as per specifications, International standard procedures, approved scheme, drawings and the direction of SiteEngineer /EIC. Note:1. The control panel and control cosole with PC will be installed underthe work of Gas detection system and the MV system is to be integratedwith the exisitng system. 2. For System Designing/Area Calculation & inter distances between block facilities refer the General layout plan and Assembly Piping Areaof respective Station. 3.Medium Velocity Water Sprinkler System for T-points at shall be designed considering wet type Deluge Valve as no compressed air is available at these locations.

-

-

-

... More
Medium Velocity Water Sprinkler System for Station process area (consisting of Barrel area, Filteration, Metering, Pressure reduction skids, KOD and piping area etc., as applicable)

1

2259533

2259533.54

... More
II INST COMPOS CSW

-

-

-

... More
Taking delivery, shifting within a road distance of 500 meters and installation & testing of the following instruments (Pressure Gauge, Pressure Switch, Pressure Transmitter, Temperature Transmitters, Flow meters etc. of various types & ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables, supply and erection of all other required materials such as the supporting structure clamps ,cannopy, screws, nuts, bolts, aluminium sheets, GI wire,steel plats, cement concrete etc. complete in all respects including supply of suitable size non flame proof cable gland at control panel end and terminating the already laid cables at field, junction box and control panel end, mounting the junction boxes as per the Drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connected to the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. The scope shall include providing assistance in testing and commissioning of the instruments along with loop checking and providing assistance to control system vendor.

-

-

-

... More
INSTALLATION OF PI+PT: Installation, assistance in testing and commissioning of Pressure Gauge and Pressure Transmitter (PI+PT) of various ratings as per the directions of Engineer-in-charge/ Site engineer and drawings

24

177501

7395.89

... More
INSTALLATION OF PT : Installation, assistance in testing and commissioning of Pressure Transmitter (PT) of various ratings as per the directions of Engineer in-charge/ Site engineer and drawings.

12

100238

8353.17

... More
INSTALLATION OF TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of temperature elements/temperature transmitter(TT) by making necessary holes on the pipes, welding the socket for thermowell on the pipe including supply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings.

10

73076

7307.61

... More
INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of sub soil temperature lements/temperature transmitter (TT) by as per the directions of engineer in-charge/site engineer and drawings

10

102146

10214.65

... More
INSTALLATION OF EMERGENCY SHUTDOWN SWITCH: Installation and testing of emergency shut - down (ESD) Push button. This includes mounting of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour.

1

9494

9494.84

... More
Installation and testing of Scrapper Detector. This includes mounting of termination box etc as per OEM recommandations, vendor drawings, directions of engineer in-charge/site engineer and other approved drawings.

3

15428

5142.67

... More
INSTALLATION OF JUNCTION BOXES: Installation of all type of explosion proof/flame proof junction boxes, non-flame proof junction box for marshalling of control cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cement concrete, painting, GI wire etc. (excluding supply of the Junction Boxes) in all respects complete as per specifications, drawings and direction of site Engineer including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour, tools, materials, glanding, ferruling etc. complete in all respects.

26

127536

4905.24

... More
INSTRUMENTATION JOBS FOR GOVs: Carrying out the instrumentation and control system jobs on the already erected actuator assembly of Gas operated valves (GOVs), installation of GOV instrumentation tubings, fittings etc.(excluding the supply of tubings & fittings) & necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

12

63462

5288.56

... More
INSTRUMENTATION JOBS FOR HOVs: Carrying out the instrumentation and control system jobs on the already erected actuator assembly of Hydraulic operated valves (HOVs) & necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

8

31731

3966.42

... More
INSTALLATION OF CONTROL PANEL: Taking delivery, shifting the panels to installation site and erection, installation, testing of Control panels/ RTU panel, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, control desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levelling, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per drawings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all respects.The indicated quantity is cumulative weight of panels.

6500

213200

32.8

... More
"STEEL STRUCTURAL WORKS: Supply, fabrication, erection and installation of steel/GI structural works of any type and shape such as cable racks, trays, push button, control posts, ladders, lugs, chain link, fencing, angles, joints, channels, plates, flats, bars etc as required as per specifications, drawings, directions of site engineer/engineer in-charge, inlcuding cost of all labour, materials, tools, consumables etc complete in all respects. Job is inclusive of taking delivery from owner's go down and shifting to site wherever required.

750

95235

126.98

... More
AIR CONDITIONERS - CASSETTE TYPE: Supply & Installation of minimum 1.8T Cassette Type ACs flushed with false ceiling along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per technical specifications and instruction of EIC / Site Engineer.

2

280034

140017.13

... More
AIR CONDITIONERS - SPLIT TYPE: Supply & Installation of minimum 1.8 T Split Type five star BEE rated ACs along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per technical specifications and instruction of EIC / Site Engineer.

2

183058

91529.13

... More
MAGNETIC PROXIMITY SWITCHES: Supply & installation of Magnetic Proximity switch for extending contact to control system for unauthorised entry of building / MOV fencing.

20

246527

12326.39

... More
INSTALLATION OF HYDROCARBON DETECTORS: Installation of Infrared Hydrocarbon detectors (point type & open path type), terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Hydrocarbon detector) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

14

52816

3772.64

... More
INSTALLATION OF HAZARDOUS AREA MCP: Installation of hazardous area Manual call points, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

10

26524

2652.49

... More
INSTALLATION OF HAZARDOUS AREA HOOTER: Installation of hazardous area hooters, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

10

26524

2652.49

... More
INSTALLATION OF HAZARDOUS AREA BEACON: Installation of hazardous area Beacons, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

10

26524

2652.49

... More
INSTRUMENTATION JOBS FOR METERING SKID Carrying out the instrumentation and control system job on the already erected Metering skid,KOD,Filteration,PRS and Heating skids as applicable & necessary cable termination in the skid junction boxes at field end and control/ metering panel end (excluding the supply of cables) as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

2

15865

7932.84

... More
III OFC AND TELECOMM COMPOSI CSW ML

-

-

-

... More
Supply, erection and installation of GI Pipe of 100 mm nominal bore medium Class B as per IS1239 subject to owner's approval including the supply & installation of all necessary pipe fittings such as bends, sockets, elbows, tees etc. bending, threading, clamping, plugs, packings, bushing etc. as required for sub ducting HDPE duct as per directions of Engineer-in-charge/ Site Engineer including cost of all labour, tools, materials complete in all respects.

60

69000

1150

... More
Supply, installation & fixing of prefabricated perforated G.I cable trays of width 150 mm, 300 mm, 450 mm & 600 mm as per siterequirement for laying of cables with standard rung spacings. Load forsupport span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectivelywith concentric static load as 70 Kg at the centre, with materials,labour, tools and tackles, consumables etc , as per drawings ,specification and directions of Site Engineer / Engineer-in-Charge

2200

391600

178

... More
Supply and installation of IDF (intermediate distribution frame) / Distribution box of 20 Pair capacity with mounting arrangement as per specifications

1

3793

3793

... More
Supply and installation of IDF (intermediate distribution frame) / Distribution box of 10 Pair capacity with mounting arrangements as per specification.

1

3810

3810

... More
Supply and installation of MDF (Main distribution frame) /Distribution box of 50 Pair capacity as per specifications

1

5080

5080

... More
Laying of HDPE conduit and blowing of OFC cable inside the SV/MOV premises along the boundary wall, line item includes supply & installation of suitable clamps , connectors, fixture, corner bends, tools & tackles (comprising of anchor bolts/nuts/accessories etc) required for OFC entry inside SV/MOV loctaionalong the boundary wall by clamping of HDPE conduit at a height of 1 meter above the finished ground level and extending it along the length of boundary wall at 1 meter height upto the transition pit inside SV/RCP building as per attached drawing no. STD-793-00. The line item includes all sevices required for blowing of OFC cable iin HDPE conduit inside the MOV/SV loctaion as per STD - 793 drawing.

1600

52800

33

... More
IV OFC AND TELECOMM COMPOSI MAINLINE

-

-

-

... More
V ELECTRICAL COMPOSITE CSW

-

-

-

... More
Supply, installation & fixing of prefabricated perforated GI cable trays with cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

5750

961055

167.14

... More
Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

1199

855486

713.5

... More
Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

3196

2380157

744.73

... More
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

174

364343

2093.93

... More
LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

-

-

-

... More
Power cables LT : OD upto 20 mm

45

185844

4129.88

... More
Power cables LT : OD above 20 mm and upto 40 mm

45

230748

5127.74

... More
Power cables LT : OD above 40 mm and upto 60 mm

18

132961

7386.74

... More
Control cables LT : OD upto 20 mm

45

247070

5490.45

... More
"ACE Chemrod Earthing:Supply, installation, testing and commissioning of ACE (Artificial concept of earthing with chemical rod) Chemrod earthing electrode by digging earthing of 3.0 Meter depth & 150 mm diameter or higher by drilling/or any other method, placing ACE Chemrod Earthing Electrode, consisting Mild steel Galvanized pipe of size 2500 mm x 50 mm outer dia or higher size x 2 mm thick or above, Galvanized MS rod of size 2575 mmx 16 mm or higher size be welded with bottom. The epoxy insulator of not less than 100 mm length is to be filled in residual gap between pipe and rod. Highly conductive substances not less than 50 Kg are to be used for treatment of soil. Model NECO T-19 of Tosha make or equivalents of YK Trader / UniqueAssociates / Shriram make. Item includes the supply and installation of the CI/RCC cover in the earth pit, backfilling etc. and construction of chamber; complete including excavation, backfilling and supply of all materials required for making earth pit as per drawings, specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects. "

144

2140276

14863.03

... More
"EARTHING PLATE : Supply & Installation of G.I. earthing plate as per drawing no. 9200-99900-404-009-00 outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels etc. and as per direction of EIC / Site engineer."

18

25038

1391.04

... More
"EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect. "

-

-

-

... More
50 mm X 6 mm G.I. earthing strip

900

231534

257.26

... More
40 mm X 5 mm G.I. earthing strip

1800

322884

179.38

... More
25mm x 4 mm copper flat

450

332064

737.92

... More
25mm x 3 mm copper flat

515

288945

561.06

... More
GI wire (8 SWG)

1160

64380

55.5

... More
GI wire / rope 35 sq. mm

450

49968

111.04

... More
GI wire / rope 10 mm diameter

450

60808

135.13

... More
Copper cable as per specifications - 95q.mm

690

1227344

1778.76

... More
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge.

-

-

-

... More
25 mm

270

109744

406.46

... More
37 mm

270

153357

567.99

... More
50 mm

395

345913

875.73

... More
100 mm

395

619411

1568.13

... More
Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge.

9000

1162350

129.15

... More
"FLAME PROOF FITTINGS : Note: All equipment under this category shall be suitable for location in zone-I gas group IIA & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure. "

-

-

-

... More
"FLP/WP PUSH BUTTON STATION : Supply ,erection,testing and commissioning of FLP/WP push button(ON/OFF) control station of approved make with /without ammeter for the motor off control at field including connection and termination of copper control cable, fabricating, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per the specification and directions of the Site Engineer/Engineer-in-charge."

-

-

-

... More
Without Ammeter

9

55309

6145.48

... More
"FLP & WP JUNCTION BOX Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable termination of motor, including connection and termination of earthing wire and conduits etc., including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect."

-

-

-

... More
8 way junction box with 8 cable entries (1 x 1" & 7 x 3/4") at bottom & 20 nos. terminals.

9

99597

11066.41

... More
6 way junction box with 6 cable entries (6 x 3/4") at bottom & 20 nos. terminals.

9

99333

11037.06

... More
4 way junction box with 4 cable entries (4 x 3/4") at bottom & 20 nos. terminals.

9

66552

7394.68

... More
FLP/WP EXHAUST FANS : Flame proof, weather proof, single phase, 12" exhaust fan, IP65, LM6 type EF1001 of FCG or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects

18

221288

12293.82

... More
FLP/WP ROTARY SWITCH : Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects

18

91062

5059.03

... More
FLP/WP DISTRIBUTION BOARDS : Supply, erection, installation, testing and commissioning of flameproof /weather proof (IP-65) distribution board as per technical specification of types mentioned for lighting purpose in MLPU / booster shed etc., including connection and termination of power cables, earthing wire and conduits etc. including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entriescomplete as per drawings, spe cifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

-

-

-

... More
Outdoor Type, floor mounted, flameproof, weatherproof (IP 65) Lighting Distribution board Type-I DB with Bus bar - 100 A TPN, Incomer - 1 no. 63 A TPN MCB & Outgoing - 9 no. 10 A SPN, MCB

9

708622

78735.78

... More
FLP/WP SWITCH CUM SOCKET : Supply, erection, installation, testing and commissioning of flameproof /weatherproof switch cum socket /welding receptacle of approved makes to be installed on walls, coloumns, structures, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., including connection and termination of earthing wire and conduits., etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

-

-

-

... More
250 V , 15 A switch cum socket with plug

9

23107

2567.52

... More
250V, 63 A Plug & welding receptacle

9

175561

19506.84

... More
415V, 63A, Switch & Socket with Plug (No. of Pins 3P +N+ E), Model EPSS 1563-61 of Baliga or Equivalent approved make

9

145427

16158.59

... More
WP 6 WAY JUNCTION BOX : Supply, erection, installation, testing and commissioning of weather proof 6 way junction box of approved make for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

9

46232

5136.98

... More
"SHOCK TREATMENT CHART : Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language)."

18

35151

1952.84

... More
"CAUTION BOARD : Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language."

18

35500

1972.27

... More
"STAINLESS STEEL INSCRIPTION PLATE : Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc."

18

16279

904.4

... More
"PLASTIC INSCRIPTION PLATE : Supply and installation of approved quality plastic name inscription plates including engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc."

18

13234

735.23

... More
"Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor."

-

-

-

... More
1 light point controlled by 1 switch.

90

105609

1173.44

... More
2 light points controlled by 1 switch

72

101794

1413.81

... More
3 light points controlled by 1 switch

54

97331

1802.44

... More
4 light points controlled by 1 switch

36

77528

2153.57

... More
Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular switch) including providing space for electronic regulator in switch box , providing and fixing fan hook in the ceiling as per specifications and drawings.

72

132255

1836.88

... More
"Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade including earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan including providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit. "

90

170083

1889.82

... More
Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specifications and drawings

45

129109

2869.1

... More
"Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st plug point for multiple exhaust fans in one circuit. "

45

93940

2087.57

... More
"Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box "

18

57062

3170.15

... More
"Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 3 numbers, 6 A 5 pin modular sockets and 10 A modular switches for UPS point as per specifications and drawings "

18

36850

2047.24

... More
"Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings "

-

-

-

... More
"Type III Distribution Board : Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification "

9

756913

84101.55

... More
Type IV DIstribution Board : Double Door Translucent Euro DB of Havells or approved make as per appendix -1, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification

18

1371886

76215.9

... More
Type V Distribution Board : Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification

9

581284

64587.18

... More
Critical Light DB : Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB

9

80932

8992.53

... More
Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bottom of light fitting shall be 2 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof and Weatherproof 2x26W CFL well glass light fitting complete with lamp and builtin control gear and choke of approved make(Cat.No.WG/A/1234 of Sudhir Switchgears or equivalent approved make), including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe(radius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box(with 4 cable entries) having 8 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings and instructions of EIC / Site engineer.

45

1089012

24200.28

... More
"Ceiling fan with electronic regulator & other accessories and fittings etc. of or approved make as per appendix -1 with the following sweep size:- 56"" Sweep"

72

214650

2981.26

... More
12" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect.

9

69916

7768.48

... More
"Exhaust fan Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greaves or of approved make as per appendix -1 fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications, drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete."

-

-

-

... More
18" Sweep

27

238579

8836.28

... More
12" Sweep

9

49069

5452.21

... More
"PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc."

-

-

-

... More
19 mm

900

87732

97.48

... More
25 mm

900

124038

137.82

... More
32 mm

900

145629

161.81

... More
Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S.458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jointing of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer.

-

-

-

... More
300 mm dia

90

216667

2407.42

... More
200 mm dia

90

114624

1273.6

... More
"Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid . "

18

77817

4323.21

... More
Installation, laying of 2 Pair PVC insulated copper conductor un-armoured telephone cables in 16 mm/ 25 mm/ 32 mm PVC conduits from IDF through ceiling/ wall/trench and post-laying end to end testing of telephone cables. The job includes supply, installation, fixing of wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O with modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and d irections of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

1200

157824

131.52

... More
Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from network switch through ceiling/wall/trench and post-laying end to end testing of cables. The job includes installation & fixing of Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

1200

110904

92.42

... More
Supply , fixing  and erection of Modular cable transit (MCT) for cable Entry to Building in proper frame including supply of  Peelable type, spare block, stay plates, compression wedgs etc. with all accessories as per specification, considering 20 % minimum spare in each module, to be installed as per the instruction of Engineer in Charge/site engineer. GALVANISED MILD STEEL frame- with Packing Space of min. 120 x240 mm with multi diameter Blocks and accessories with peeling off arrangement to adjust cable size from 3.5 MM to 99 MM outer dia .

9

234995

26110.66

... More
Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation shall be provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work and shall be taken up separately.

-

-

-

... More
For 30 M Height High Mast Tower

12

2104590

175382.53

... More
"FLAME PROOF LIGHT FITTINGS : Supply erection , installation , testing and commissioning of flame proof light fittings of approved make alongwith flame- proof control gear box containing ballast & condensor and lamp, including fixing on walls,columns, structures, poles etc. as required ,grouting clamping , supporting including fabrication and installation of clamps, nuts, bolts ,earthing with 8 SWG GI wire , connecting the lamps, cable terminals at the light fittings, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc.complete as per drawings, specifications and directions of Site Engineer / Engineer-in-Charge including the cost of all labour ,tools, materials etc. complete in every respect."

-

-

-

... More
"FLAMEPROOF LED FITTING 125W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:- IIA/IIB, IP 65, T6. Complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with provision of Cable Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), Mounting Arrangement: with M.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye Bolt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5."

36

901100

25030.57

... More
"FLAMEPROOF LED FITTING 60W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:- IIA/IIB, IP 65, T6. complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with a provision of Cable Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), Mounting Arrangement: with M.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye Bolt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5. Without External reflector"

18

225275

12515.29

... More
Flameproof LED Tubelight fitting, fixture complete with Philips Essential LED Tube 1200MM 18W865 T8 Model complete.

36

525642

14601.17

... More
FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007

36

316800

8800

... More
FLAMEPROOF EXHAUST FAN,12", SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007

18

156996

8722

... More
"Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications."

-

-

-

... More
LED Light fitting type RC380B LED32S-6500 L120W30 PSU OD of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc suitable for installation in false ceiling

86

538157

6257.64

... More
WP Endura LED: Supply and fixing of surface mounted weather proof Endura LED WT 550 light fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation

36

319140

8865

... More
LED Light fitting suspended type Sereno SP824 P LED 30S-5000 GR OA of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

86

717542

8343.52

... More
LED Light fitting type TMC 501 P 2xT-LED 22W P3242 of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

194

404660

2085.88

... More
LED Light fitting Cirrus Mini pro SM200C LED16S 6500 PSU OD WH of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

18

93864

5214.7

... More
LED Light fitting GreenLED down light DN092B LED10S-6500 PSU WH of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

18

46932

2607.35

... More
Installation, testing, commissioning charges of SPV based LED street light including supply of 5 m high GI pole (with suitable panel mounting arrangement) and associated civil foundation works complete in all respects

360

1480809

4113.36

... More
VI ELECTRICAL PCP COMPOS MAINLINE

-

-

-

... More
Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings.

-

-

-

... More
Zinc Anode

48

361240

7525.85

... More
"Supply & installation of Anode bed ( deep well type with MMO anodes) as per the approved configuration for Impressed Current Cathodic Protection system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe, casing pipe , centralizers, vent pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection and providing foundation of Anode Junction Box as per specifications inlcuding supply, excavation, backfill of earth etc. as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour & material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
Mainline CP & Station CP : Anode bed deep well type

3

1620478

540159.5

... More
"Supply & installation of Anode bed ( shallow type ) as per the approved configuration for 'Impressed Current Cathodic Protection' system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection, providing foundations of Anode Junction Box, chain link fencing around anode junction box wherever required, as per specifications including supply of back fill material, excavation, backfill of earth and filling the sand with requisite back fill material as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour and material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
Mainline CP : Anode bed shallow type

2

629280

314640.1

... More
"Cable Marker Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all materials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge."

-

-

-

... More
Cable marker

15

13929

928.65

... More
Supply & installation of GSM based digital data logger of approved make for remote monitoring of PSP, alongwith supply and installation of permanent reference cell of approved make with tail cable (10 m), including making all connections, all labour and materials as per specification and approved design.

-

-

-

... More
Data logger

5

792143

158428.64

... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

-

-

-

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for PSP Measurment)

16

286377

17898.62

... More
Type DAC (With Ingress Protection IP:55)

24

683224

28467.68

... More
Flameproof Type E (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment.

15

612250

40816.71

... More
Flameproof Type DMV (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment.

1

35822

35822.07

... More
"The job at each TLP of type DMV at stations for protection of Valve locations shall include Supply, installation, testing and commissioning of the following: A. TLP of type DMV shall be flameproof Ex#d casted from Aluminium alloy LM6 duly approved by PESO and weatherproof as per certified and approved drawing for flameproof junction box having all connection facilities as per latest revision of drawing 9200-99900-404-601-02 (STD-481) and 9200-99900-404-603-00 : (STD-483), Heavy Gauge MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal stud bolts, neoprene gasket for front door, vandal proof concealed lock, The work includes excavation and providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. Flameproof & weatherproof DMV type TLP shall house solid state diode decoupling device and Zinc anodes shall be used for grounding as detailed below. B. Zinc anodes (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. Number of zinc anodes shall be such that earth resistance value of up to 5 Ohm is obtained. C. Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Connection scheme for the above mentioned item shall be as per latest revision of standard drawing no.: 9200-99900-404-601-02 (STD-481). Flameproof certificate from PESO shall be submitted for the flameproof & weather proof TLP for the item."

-

-

-

... More
Flameproof Type DMV with inbuilt provision of Voltmeter & pushbutton for PSP Measurment (With Ingress Protection IP:55)

8

872432

109054.04

... More
"The job at each TLP of type DAC for protection from AC interference or for protection at Valve locations shall include supply, installation, testing and commissioning of the following; A. TLP type DAC fabricated of MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Gauge MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal stud bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of 9200-99900-404-601-02 (STD-481) and Standard AFC drawing 9200-99900-404-603-00 : (STD-483). The work includes excavation and providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal stud bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to pipe coating (with coating repair etc.), backfilling the cable trenches, clearing and cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cable required for the job (as per site conditions) and including lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the front side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. DAC/DMV type TLP shall house solid state decoupling device and Zinc anodes shall be used for grounding as detailed below. B. Zinc anodes (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter for each anode including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. Number of zinc anodes shall be such that earth resistance value of up to 5 Ohm is obtained. Zinc anodes shall be connected to the TLP through weather proof junction box/ boxes. C. Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations of voltage level 66 KV or above including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, etc. The job shall be complete in all respects including all required materials, tools, consumables, labour as per work specifications, engineering document & direction of the Site Engineer/Engineer-In-Charge. Connection scheme for the above mentioned item shall be as per latest revision of standard drawing no.: 9200-99900-404-601-02 (STD-481)."

-

-

-

... More
Type DAC (With Ingress Protection IP:55)

1

107551

107551.87

... More
VII ELECTRICAL TCP COMPOS MAINLINE

-

-

-

... More
Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable of size of 1c x 6 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings.

-

-

-

... More
Magnesium Anode

264

1657492

6278.38

... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

-

-

-

... More
Type A (With Ingress Protection IP:55)

60

873750

14562.51

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for PSP Measurment)

5

89493

17898.62

... More
Type B (With Ingress Protection IP:55)

60

2100057

35000.95

... More
Type C (With Ingress Protection IP:55)

6

137364

22894.15

... More
Type D (With Ingress Protection IP:55)

32

568345

17760.8

... More
Preparation & installation of corrosion coupon from owner supplied coated pipe. which involves preparation of sample of size 2"x4", application of pipeline coating material on the coupon, soldering 6 sq. mm. cable with coupon, sealing the soldered joint with epoxy, positioning the coupon at the pipe line depth and with in a distance of 0.5 M from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement for preparation of the coupon. The work complete in all respect shall include supply of all labour, tools etc complete as per the directions of the Site Engineer and as per drawing no. 9200-99900-404-601-01 & 9200-99900-404-607-01.

-

-

-

... More
Corrosion Coupons

120

211800

1765

... More
IP 101 IP 102 Service ITC TAMILNADU

-

-

-

... More
I MECHANICAL WORK SERVICE CSW

-

-

-

... More
Above Ground Equipments Installation: Taking delivery of equipments from designated stores/stockyard, shifting / transporting to station premises, placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water/ nitrogen as applicable, draining, checking, testing with Nitrogen, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instructions, specifications and instructions of Site Engineer / EIC.

-

-

-

... More
SCRAPER BARREL

-

-

-

... More
24"X28" x 600# Bi-Directional Scrapper Barrel including pig handling system & Jib crane

2

359202

179601.33

... More
14"X18" x 600# Bi-Directional Scrapper Barrel

2

277216

138608

... More
6"X10" x 600# Bi-Directional Scrapper Barrel

4

195452

48863

... More
INSULATING COUPLING

-

-

-

... More
24" x 600# Insulating Coupling

2

46128

23064

... More
14" x 600# Insulating Coupling

2

32837

16418.85

... More
8" x 600# Insulating Coupling

12

112581

9381.75

... More
6" x 600# Insulating Coupling

8

56296

7037.1

... More
4" x 600# Insulating Coupling

2

9382

4691.4

... More
Knock out drum

-

-

-

... More
KOD SKID

20

633269

31663.45

... More
FILTRATION SKID

-

-

-

... More
FILTRATION SKID FOR IP 102

27

854913

31663.45

... More
FILTRATION SKID FOR RT TANFAC

4

126653

31663.45

... More
METERING SKID

-

-

-

... More
CHECK METERING SKID FOR IP 102

17

538278

31663.45

... More
CHECK METERING SKID FOR PUDUCHERRY SPURLINE

11

348297

31663.45

... More
CUSTODY TRANSFER METERING SKID FOR M/s TANFAC

1

31663

31663.45

... More
PRS SKID

-

-

-

... More
PRS SKID TANFAC

5

158317

31663.45

... More
FLOW TEE

-

-

-

... More
24" x 600# Flow tee (Equal)

2

46128

23064

... More
24" x 14" x 600# Flow tee (Unequal)

1

23064

23064

... More
24" x 8" x 600# Flow tee (Unequal)

10

230640

23064

... More
14" x 600# Flow tee (Equal)

1

16418

16418.85

... More
14" x 6" x 600# Flow tee (Unequal)

4

65675

16418.85

... More
6" x 600# Flow tee (Equal)

4

28148

7037.1

... More
6" x 4" x 600# Flow Tee (Unequal)

2

14074

7037.1

... More
Above ground piping: Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises/stockyard/store, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and intsalling pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC.

-

-

-

... More
24" OD x 0.625" WT APL 5L X 70

80

886451

11080.64

... More
14" OD x 0.438" WT APL 5L X 60

80

414366

5179.58

... More
12.75" OD x 0.406" API 5L X70

30

105096

3503.22

... More
10.75" OD x 0.594" ASTM A333 GR.6

10

38713

3871.34

... More
8.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X52

180

557172

3095.4

... More
6.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X 52

205

586865

2862.76

... More
4.5" OD x 0.337" ASTM A333 GR.6

85

176857

2080.68

... More
3.5" OD x 0.300" ASTM A333 GR.6

30

41997

1399.9

... More
2.375" OD x 0.344" ASTM A333 GR.6

250

231905

927.62

... More
1.315" OD x 0.25" ASTM A333 GR.6

130

83101

639.24

... More
1.050" OD x 0.219" ASTM A333 GR.6

230

97980

426

... More
Under ground piping:(Process Piping) Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises/stockyard/stores transporting the same to site, fabrication and erection of underground piping including cutting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., underground at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc., cleaning the material surface by sandblast cleaning, coating and wrapping the pipes/pipe fittings with coaltar base tape coating material (including the supply of coating tape, precoat material etc.), holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of the Site Engineer / EIC

-

-

-

... More
24" OD x 0.625" WT APL 5L X 70

20

257810

12890.51

... More
14" OD x 0.438" WT APL 5L X 60

20

136107

6805.36

... More
12.75" OD x 0.406" API 5L X70

20

91013

4550.67

... More
8.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X52

100

312289

3122.89

... More
6.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X 52

80

201300

2516.25

... More
4.5" OD x 0.337" ASTM A333 GR.6

50

92128

1842.56

... More
3.5" OD x 0.300" ASTM A333 GR.6

20

31467

1573.37

... More
2.375" OD x 0.344" ASTM A333 GR.6

155

175255

1130.68

... More
1.315" OD x 0.25" ASTM A333 GR.6

130

131976

1015.2

... More
1.050" OD x 0.219" ASTM A333 GR.6

130

90209

693.92

... More
Installation of Valves:( Process Piping) Taking delivery of valves of all types and pressure rating from the designated location within station premises, transporting the same to site, carrying out pre-hydrotesting of valve and seat test of valve before installation of valve at specified pressure as per instruction of EIC, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, flood coating and wrapping of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC.

-

-

-

... More
API 6D BALL VALVE -GAS OVER OIL ACTUATED

-

-

-

... More
24"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve -Gas over oil Actuated

2

74339

37169.6

... More
14"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve -Gas over oil Actuated

2

43364

21682.27

... More
6"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve --Gas over oil Actuated

4

47193

11798.48

... More
API 6D BALL VALVE -Hydraulic Actuated

-

-

-

... More
24"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve - Hydraulic Actuated

2

74339

37169.6

... More
14"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve - Hydraulic Actuated

2

43364

21682.27

... More
API 6D BALL VALVE -Lever / Gear Operated valve

-

-

-

... More
24"x ANSI 600#, Bolted F/F, A/G, Gear operated

2

59471

29735.68

... More
14"x ANSI 600#, Bolted F/F, A/G, Gear operated

2

34691

17345.81

... More
12"x ANSI 600#, Bolted F/F, A/G, Gear operated

6

89207

14867.84

... More
8"x ANSI 600#, Bolted F/F, A/G, Gear ope

13

163605

12585.04

... More
6"x ANSI 600#, Bolted F/F, A/G, Gear ope

10

94387

9438.78

... More
4"x ANSI 600#, Bolted F/F, A/G, Gear ope

34

213945

6292.52

... More
3"x ANSI 600#, Bolted F/F, A/G, Gear ope

4

18877

4719.39

... More
2"x ANSI 600#, Bolted F/F, A/G, Gear ope

128

266373

2081.04

... More
8"x ANSI 600#, fully welded, W/W, A/G, Gear operated

9

113265

12585.04

... More
6"x ANSI 600#, fully welded, W/W, A/G, Gear operated

4

37755

9438.78

... More
4"x ANSI 600#, fully welded, W/W, A/G, Gear operated

12

75510

6292.52

... More
2"x ANSI 600# fully welded,w/w, A/G, lever operated

99

206022

2081.04

... More
8"x ANSI 600# fully welded,w/w, U/G, Gear operated-Extended stem

10

125850

12585.04

... More
6"x ANSI 600# fully welded,w/w, U/G, Gear operated-Extended stem

2

18877

9438.78

... More
4"x ANSI 600# fully welded,w/w, U/G, Gear operated-Extended stem

2

12585

6292.52

... More
BS 5351/ISO 17292 BALL VALVE/ BS 1873 Globe Valve

-

-

-

... More
1"x ANSI 800# HOV W/W BS 5351 BALL VALVE

33

25878

784.19

... More
3/4"x ANSI 800# HOV W/W BS 5351 BALL VAL

184

108217

588.14

... More
8"x ANSI 600# F/F BS 1873 GLOBE VALVE

14

160847

11489.09

... More
6"x ANSI 600# F/F BS 1873 GLOBE VALVE

8

68934

8616.82

... More
4"x ANSI 600# F/F BS 1873 GLOBE VALVE

10

57445

5744.54

... More
2"x ANSI 600# F/F BS 1873 GLOBE VALVE

30

62088

2069.6

... More
1" X 2" x ANSI 600# x150# F/F PSV

6

17580

2930.13

... More
Radiographic Inspection: Inspection of welding by radiographic method on all types of piping including processing of films and interpreting the results of weld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the welds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all pesonnel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i),,Payment will be on the basis of number of welds of the,,respective size radiographed and shall be all inclusive for ,,the complete job of radiographic inspection as envisaged in ,,the contract document. ii),,Radiography not involving full girth weld will be paid at ,,50% of the rate for full girth weld for the respective size. iii)For set-on type branch welding, the rate for radiography ,,will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective ,,films or repair of welds shall be done at contractor's cost. In case where radiography is not possible: v) Verification by utrasonic testing shall be done at ,,contractors cost. vi) Magenetic particle inspection as and where required shall be ,,done at Contractors cost. vii) Digitization of all films to be carried out.

-

-

-

... More
24" NB Pipe Joints

60

261240

4354

... More
14" NB Pipe Joints

60

146649

2444.16

... More
12" NB Pipe Joints

40

93610

2340.26

... More
10" NB Pipe Joints

10

17707

1770.79

... More
8" NB Pipe Joints

220

320656

1457.53

... More
6" NB Pipe Joints

190

201158

1058.73

... More
4" NB Pipe Joints

210

210480

1002.29

... More
3" NB Pipe Joints

40

26588

664.72

... More
2" NB Pipe Joints

760

430144

565.98

... More
1" NB Pipe Joints

240

99861

416.09

... More
3/4" NB Pipe Joints

550

214830

390.6

... More
Sinlge Cut Joint Hook-up: Cutting of portion of existing piping, trimming, grinding, bevelling the edges, aligning without addition of spool piece, welding the joint including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal.

-

-

-

... More
30" OD

1

26019

26019

... More
16" OD

1

11988

11988

... More
10" OD

1

8297

8297.03

... More
4" OD

1

3258

3258.46

... More
Double Cut Joint Hook-up: Cutting of portion of existing piping upto and including a length of 500 mm, trimming, grinding, bevelling the edges, adding spool piece of required length / tee and the corresponding pipe size, thickness, adjoining and welding both the ends including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal.

-

-

-

... More
16" OD

1

15003

15003

... More
4" OD

1

3985

3985.54

... More
Dismantling of Structures: Dismantling by opening joints or by gas cutting/ cold cutting (wherever required as per site condition) of existing steel structural such as support for pipes, pipe fittings, valves, plate forms, walkways, stairways etc. including excavation work wherever required handling, loading into truck for purpose of weighing, shifting to the designated location within the pump station premises and handing over, completing the work in all respect as per drawings, instruction of the Site Engineer / EIC.

1

12477

12477.51

... More
Dismantling of Piping (Aboveground): Dismantling of existing over ground piping works of all types and sizes by opening flange joints or by gas cutting/ cold cutting or any other approved suitable means without damaging other portions of work. The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets nuts, bolts etc. attached supports alongwith any instruments such as pressure gauge, temperature gauge etc. handling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipments, consumables etc. necessary to perform and complete the work in all respects as per drawings, instructions of the Site Engineer / EIC (payment shall be made on linear measurement of dismantled piping including bends tees etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer before dismantling of pipe. Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be dismantelled.

1

16600

16600.51

... More
Dismantling of Piping (Underground): Dismantling the existing under ground piping, locating, retrieving including excavating the proper trenches by cutting the pipes without damaging other portions of work. The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets, nuts, bolts etc., handling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipment consumables etc. necessary to perform and complete the work in all respects as per drawing, instructions of the Site Engineer / EIC. (Payment shall be made on the linear measurement of dismantled piping including bend, tees, reducers etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer before dismantling of pipe.Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be dismantled.

1

23208

23208.42

... More
Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- FOR SV STATIONS

8

60000

7500

... More
Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- FOR IP STATIONS

1

12500

12500

... More
Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- FOR RT STATIONS/TERMINALS

2

25000

12500

... More
Providing services assistance during pre-commissioning and commissioning of entire SV station piping with or without tap-off/with or without scraper barrel including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge

8

100000

12500

... More
Providing services assistance during pre-commissioning and commissioning of scraper barrel, Knock out drums, filters, metering skid, pressure reduction skids as applicable for entire IP station piping including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge

1

25000

25000

... More
Providing services assistance during pre-commissioning and commissioning of scraper barrel, Knock out drums, filters, metering skid, pressure reduction skids as applicable for entire Receipt station piping including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge

2

50000

25000

... More
II INST SERVIC CSW

-

-

-

... More
INSTALLATION OF PRESSURE INDICATOR: Installation, testing and commissioning of Pressure Indicator (PI) of various ratings with/ without gauge saver as per directions of Engineer in-charge/ Site engineer and Drawings.

18

65009

3611.64

... More
AS BUILT DOCUMENTATION: As built documentation for each station covering a) Control /signalling cable layout drawings, b) Cable trench details, c) Cable marker details, d) Earth grid layout, e) Field instrument termination details, f) Cable schedule, g) Junction box wiring details, h) Earth resistivity measurement data, i) Field panel termination details, j) Calibration data of all instruments tested as per scope k) OTDR Traces of the laid OFC for all SV, RT, IP, RWS locations as applicable.

1

105486

105486.93

... More
III OFC AND TELECOMM SERVICE CSW ML

-

-

-

... More
Laying of HDPE pipe(excluding blowing of OFC) in mainline pipe trench/ independent trench at the bottom in all types of soil (including roads, canals, rivers, nullahs, water course crossings, submerged crossings, saltpan areas etc.) including supply and installation of suitable straps for strapping the HDPE duct with mainline pipe for anti buoyancy, installation of HDPE duct accessories such as plastic couplers, end caps, end plugs, cable sealing plugs, supply and installation of warning tape, consumable guide rods, HDPE jointing, inspection of HDPE joints, testing the installed HDPE duct by blowing "mandrel" with compressed air, pressure testing the HDPE pipe after laying as per procedure and performing all work as per drawings, specifications and instruction of the Engineer-in-charge/ Site Engineer and provisions of the contract document for making the duct ready in all respect for OFC blowing. The job includes transportation, loading and unloading of HDPE ducts in nominal length of 1000 meters and duct accessories such as couplers, end caps, end sealing plugs etc. to various sites along the entire ROW / HDD crossing locations as per specifications and directions of Engineer-in-charge/ Site Engineer

130

2135770

16429

... More
Laying of HDPE Pipe in trenches/ walls/ concrete structure/ panels etc. as per specifications & drawings & blowing/ laying of Owner supplied Aurmoured/Unarmoured Optical Fibre Cable in HDPE pipe,jointing & splicing of OFC, carrying out end to end testing of laid Optical fibre cables by taking OTDR traces and submitting the OTDR trace printouts to Site Engineer/ Engineer-in-charge. The job includes the supply and installation of required materials such as fixing clamps, screws, tags etc. as required to complete the job in all respects as per drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, test instruments, materials etc. The job includes handing over the tested cables to the Telecom Works Contractor and providing necessary assistance/ support to the Telecom Works Contractor in commissioning of Local Area Network.

1000

189000

189

... More
"Trenching for laying of HDPE in Independent trench Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.65 metres including shoring, strutting etc. (if necessary), backfilling the trench, as directed by Engineer-in-charge/ Site Engineer, including all labour and materials complete as per drawings and tender specifications "

1237.5

245025

198

... More
Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (ROW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer.

131

3543943

27053

... More
Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/ Site Engineer

113

1008638

8926

... More
Installation of RF iD type Electronic Markers as per tender specifications. The job includes configuration & programming of the Electronic markers to write information data as per directions of Engineer-in-charge/ Site Engineer.

111

74148

668

... More
Installation of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer

130

143910

1107

... More
Installation of OFC Joint pit markers at every joint location as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer

111

114996

1036

... More
Installation of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer.

111

281052

2532

... More
Installation of Transition Pits at building entry points as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer

9

60885

6765

... More
Installation of wall mounted Fibre Termination Box (FTB) as per tender specifications and directions of Engineer-in-charge/ Site Engineer

1

6282

6282

... More
Installation of Wall mounted Cabinet (switching closet including network switch , UPS etc in wall mount cabinet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications

1

6503

6503

... More
IV OFC AND TELECOMM SERVICE MAINLINE

-

-

-

... More
V ELECTRICAL SERVICE CSW

-

-

-

... More
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

3995

2399916

600.73

... More
WBM ROAD / CONCRETE BREAKING : WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

150

579529

3863.53

... More
"Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge"

-

-

-

... More
Power cables LT : OD upto 20 mm

1730

53612

30.99

... More
Power cables LT : OD above 20 mm and upto 40 mm

10800

486540

45.05

... More
Power cables LT : OD above 40 mm and upto 60 mm

3600

262476

72.91

... More
Power Control cables LT : OD upto 20 mm

3600

160056

44.46

... More
Control cables (T&I) : OD upto 20 mm

10250

715245

69.78

... More
Control cables (T&I) : OD above 20 mm and upto 30 mm

1220

97063

79.56

... More
Control cables (T&I) : OD above 30 mm and upto 40 mm

200

18848

94.24

... More
"Erection, Installation, Connecting, testing and commissioning of 25/20/15 KVA three/single phase 415V/240V Silent Emergency DG with PLC based AMF panel, batteries and acoustic enclosure, including execution of terminal connections of power and control cables for DG set & AMF Panel & other accessories of DG Set earthing of alternator neutral, frame and armour of the cable etc., as per drawings, specifications, recommendations of the D.G. Set manufacturer and directions of the Site Engineer. The job complete in all respects including supply and installation of all the required power and control cable upto AMF Panel, cable end lugs, cable glands,GI/Copper earthing wire/strip, acoustic enclosure etc.including all labour, tools, consumable etc. Cost is inclusive of Supervision & Assistance in installation & commissioning of above DG set(s) at site by DG supplier. It may be noted that all works related to foundation is included in the contractor's scope of work. ( The POL for the DG set commissioning & trial run shall be arranged by the owner, free of cost) Note : Main LT power cable from DG set to ACDB panel shall be provided by the Owner."

-

-

-

... More
50/25/20/15 KVA DG Set

9

380378

42264.33

... More
Installation of corrosion monitoring probes including 2" Flareweld on station piping at desired location and 12 O'Clock position for mounting of ER Probe under the supervision of ER probe supplier and site engineer. Flareweld assembly shall be supplied by contractor as per item mnetioned in supply part. The job complete in all respect with material, tools & tackles, consumables etc. Cost is inclusive of Supervision & Assistance in installation & commissioning of ER probe at site by ER probe supplier.

1

15431

15431.89

... More
Installation, testing and commissioning of Free Standing Floor mounted ACDB Panel as per the specifications including terminations, connections, supply of end lugs, cable glands, making spare entries blind, providing tags & ferrules, pasting panel wiring diagram with acrylic sheet inside the panel, all other materials, labour tools and tackles as per the directions of the Site Engineer / Engineer-in-charge.Cost is inclusive of Supervision & Assistance in installation & commissioning of ACDB panels at site by panel supplier.

-

-

-

... More
ACDB Panel

9

223288

24809.87

... More
Erection, Installation,Testing & Commissioning of the high mast tower with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour. Scope of work shall include erection & installation of high mast tower, cable connections, erection & installation of luminaries & aviation lights, lightning finial, all accessories, cables, etc., erection, foundation casting & grouting of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to base compartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mast tower including construction of earth pits to be operated in relevant separate item. Cost is inclusive of Supervision & Assistance in installation & commissioning of high mast at site by HMT supplier.

-

-

-

... More
For 30 M Height High Mast Tower

12

811821

67651.83

... More
VI ELECTRICAL PCP SERVIC MAINLINE

-

-

-

... More
Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.

-

-

-

... More
Solid State Decoupling Device

54

342647

6345.33

... More
Installation of grounding cells including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of grounding cell etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Gounding Cell

15

72670

4844.69

... More
Installation of surge arrestors including terminating the cables, laying of cable, testing & commissioning of surge arrestors etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Surge Arrestor/ Surge Diverter

15

94760

6317.34

... More
Installation of permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cable, testing & commissioning of cell etc. all complete with required material, excavation, backfilling etc. as per specifications, recommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Permanent half cell

15

110913

7394.23

... More
Conducting " Coating-Resistance Survey" for calculation of effective coating resistance of the pipeline in ohms-sq.m. along the entire pipeline and plotting on SEMILOG or X-Y GRAPH & submitting the report in graphical form as well as soft copy as per Specification / approved procedure and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Coating Resistance Survey

120

185629

1546.91

... More
Conducting Close Interval ON/OFF Potential Logging Survey at an interval of 1 m over the buried line in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Close Interval ON/OFF Potential logging survey

120

458187

3818.23

... More
"Conducting Direct Current Voltage Gradient Survey over the buried line to identify / pin point the coating defects in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects as per directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contractor, who will arrange to repair the defects."

-

-

-

... More
Direct Current Voltage Gradient Survey

120

532720

4439.34

... More
Conducting "Soil Resistivity Survey" at anode bed location after ascertaining its suitablity with respect to the existing system , for installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Soil Resitivity Survey

5

154963

30992.78

... More
"Conducting AC interference survey, to detect presence of any AC voltage induced on pipeline as per approved procedure. The work shall be completed in all respects including survey recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at all TLPs by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations."

-

-

-

... More
AC interference survey

120

1396213

11635.11

... More
Conducting Mututal Interference Survey among the new and existing pipelines / facilities(foreign) by taking PSP survey of all the pipelines as per approved procedure to determine level of interference at different places along the pipeline and at point of crossing in common ROW including identifying points and providing the data/ record in graphical form and carrying out all necessary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remedial measures undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphs in six sets.The item should be complete in all respect including survey, work for mitigating the interference and post mitigating survey as per specifications/directions of site engineer / Engineer-in-Charge.

-

-

-

... More
Mutual Interference Survey

120

871635

7263.63

... More
"Cathodic Protection Units Erection, testing and commissioning of cathodic protection units (CPTR/CPPSM); including supply and installation of all facilities, materials etc., including fuses, all supporting structures, laying and connecting the 1100 V Grade power cable (2 runs of 1Cx25 sqmm Cu. conductor XLPE insulated Armoured Cable) from DCDB to CPPSM unit / laying and connecting the 1100 V Grade power cable (owner provided 1 run of 3Cx10 sqmm Al. conductor XLPE insulated Armoured Cable) from ACDB to CPTR unit, providing the earthing arrangement. The work includes furnishing the test results by conducting all the NO LOAD and ON LOAD tests on the CP units and adjusting settings as required and testing the pipeline section for full cathodic protection for entire stretch. The job complete in all respect shall include cost of all labour, tools as per specifications and directions of the Site Engineer / Engineer-in-Charge. "

-

-

-

... More
230V AC cum (-) 48V DC Operated automatic type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V, 25 A DC with with DC-DC converter & SCADA linkage facility as per specifications

5

213493

42698.64

... More
Installation, testing and commissioning of 48 V, 400 AH Battery bank system with rack, battery charger etc., as per specifications including interconnection with other equipments etc., all complete with materials like cables, lugs, sealing materials and other materials deemed necessary. Item includes supply, laying, connection and termination of all copper conductor XLPE cables from ACDB to Battery Charger

-

-

-

... More
Battery Bank System

5

456257

91251.59

... More
Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and all other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank

-

-

-

... More
DC distribution board

5

17563

3512.66

... More
Laying of anode header / cathode / reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / half cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleeve, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, backfilling etc.,; in all types of strata and soil (including rock) by making the trench, back filling the trench, cable terminations, work complete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engineer-In-Charge and approved drawings.

-

-

-

... More
1cx35 sq. mm

2500

475125

190.05

... More
1cx25 sq. mm

500

70525

141.05

... More
2cx6 sq. mm

2550

381582

149.64

... More
Measuring, recording and submitting the cathodic protection readings along the entire pipeline by repeated adjustments of the settings of the CPTR/CPPSM units etc as per specifications for achieving full/maximum protection of all the stretches as per the criteria of protection mentioned in the specifications. Measuring the relevant readings at the cathodic protection stations and "pipe to soil potential" readings at all the test lead locations along the pipeline including the CP station parameters like current(AC/DC), voltage(AC/DC),circuit resistance ,battery voltage/current etc.,preparing and submitting pipe to soil potential profile, graphs and other data pertaining to the cathodic protection of the pipeline,job complete in all respects as per specification and instructions of Site Engineer / Engineer-in-Charge, including cost of all labour, instruments and services rendered.

-

-

-

... More
CP Readings

120

54694

455.79

... More
"Final Commisioning of CP system Final Commissioning of the impressed current cathodic protection system for the mainline for achieving full protection as per protection criteria as mentioned in the specifictions through repeated adjustments of the CP units after installation of galvanic anodes for hot spot protection and mitigation of AC/ DC interference, if any and submission of the resultant data to the owner and testing, measuring, recording and submitting all these data once again after the lapse of a period as per specifications / directions of the Site engineer / Engineer-in-Charge, including the cost of all labour tools and materials as required, complete in all respect."

-

-

-

... More
Commissioning

1

102350

102350.08

... More
VII ELECTRICAL TCP SERVIC MAINLINE

-

-

-

... More
Pipe to Soil potential Readings : Measurement, recording and submission of Pipe to Soil Potential readings by connecting / disconnecting the Mg anodes (for achieving optimal protection through TLPs) along the entire pipeline and at stations, including preparing and submiting relative PSP profile and other relevant data pertaining to the cathodic protection of the pipeline, including cost of all labour, instruments and services rendered. The readings shall be furnished as per the specifications and as per the directions of the Site Engineer/Engineer-in-Charge.

-

-

-

... More
PSP Readings

1

189833

189833.9

... More
TCP System Engineering Document : Prepare & Submit Engineering Document including detail engineering & drawings for TCP system and other documentations as mentioned in the specification and as per direction of Site Engineer / Engineer-in-Charge. The work includes submission of final document afterapproval in requisite sets.

-

-

-

... More
Engineering Document/ Technical report

1

110103

110103.66

... More
Conducting Pearson Survey over the buried line in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one reproducible containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects.

120

448603

3738.36

... More
IP 101 IP 102 Supply ITC TAMILNADU

-

-

-

... More
I MECHANICAL WORK SUPPLY CSW

-

-

-

... More
Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
150#

-

-

-

... More
8" SWMG ANSI 150#

12

3439

286.66

... More
6" SWMG ANSI 150#

6

1315

219.21

... More
4" SWMG ANSI 150#

4

714

178.68

... More
1" SWMG ANSI 150#

39

2097

53.77

... More
600#

-

-

-

... More
30" SWMG ANSI 600#

2

3892

1946.46

... More
24" SWMG ANSI 600#

16

24914

1557.17

... More
16" SWMG ANSI 600#

3

3114

1038.11

... More
14" SWMG ANSI 600#

16

16577

1036.12

... More
12" SWMG ANSI 600#

24

24818

1034.12

... More
8" SWMG ANSI 600#

84

67236

800.43

... More
6" SWMG ANSI 600#

72

56558

785.54

... More
4" SWMG ANSI 600#

58

37373

644.37

... More
3" SWMG ANSI 600#

10

3248

324.81

... More
2" SWMG ANSI 600#

228

42715

187.35

... More
3/4" SWMG ANSI 600#

154

12612

81.9

... More
Supply and delivery of Insulating Gaskets at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
2" SWMG ANSI 600#

16

128000

8000

... More
Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
150#

-

-

-

... More
Fasteners for Flanges 8" x 150# (0.750" Dia. X 4.75" Length)

96

9067

94.45

... More
Fasteners for Flanges 6" x 150# (0.750" Dia. X 4.50" Length)

48

3828

79.76

... More
Fasteners for Flanges 4" x 150# (0.625" Dia. X 4.00" Length)

32

1965

61.43

... More
Fasteners for Flanges 1" x 150# (0.500" Dia. X 3.00" Length )

156

6133

39.32

... More
600#

-

-

-

... More
Fasteners for Flanges 30" x 600# (2" Dia. (M52) X 17.13" Length) ASME B16.47 Series A

56

83395

1489.2

... More
Fasteners for Flanges 24" x 600# (1.875" Dia. X 17.50" Length) - extended stud length for flanges with spectacle blind

96

136922

1426.28

... More
Fasteners for Flanges 24" x 600# (1.875" Dia. X 15.00" Length)

288

352088

1222.53

... More
Fasteners for Flanges 16" x 600# (1.500" Dia. X 13.50" Length) - extended stud length for flanges with spectacle blind

20

13151

657.57

... More
Fasteners for Flanges 16" x 600# (1.500" Dia. X 11.00" Length)

40

21432

535.8

... More
Fasteners for Flanges 14" x 600# (1.375" Dia. X 13.00" Length) - extended stud length for flanges with spectacle blind

120

117136

976.14

... More
Fasteners for Flanges 14" x 600# (1.375" Dia. X 10.25" Length)

200

153930

769.65

... More
Fasteners for Flanges 12" x 600# (1.25" Dia. X 12.00" Length) - extended stud length for flanges with spectacle blind

160

85728

535.8

... More
Fasteners for Flanges 12" x 600# (1.25" Dia. X 9.75" Length)

320

163904

512.2

... More
Fasteners for Flanges 8" x 600# (1.125" Dia. X 9.75" Length) - extended stud length for flanges with spectacle blind

288

131040

455

... More
Fasteners for Flanges 8" x 600# (1.125" Dia. X 8.25" Length)

720

254289

353.18

... More
Fasteners for Flanges 6" x 600# (1.0" Dia. X 9.0" Length) - extended stud length for flanges with spectacle blind

288

78410

272.26

... More
Fasteners for Flanges 6" x 600# (1.0" Dia. X 7.5" Length)

576

127831

221.93

... More
Fasteners for Flanges 4" x 600# (0.875" Dia. X 7.75" Length) - extended stud length for flanges with spectacle blind

136

38987

286.67

... More
Fasteners for Flanges 4" x 600# (0.875" Dia. X 6.50" Length)

328

79041

240.98

... More
Fasteners for Flanges 3" x 600# ( 0.75" Dia. X 6.50" Length ) - extended stud length for flanges with spectacle blind

32

4013

125.41

... More
Fasteners for Flanges 3" x 600# ( 0.75" Dia. X 5.50" Length )

48

4991

103.99

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 5.75" Length) - extended stud length for flanges with spectacle blind

384

43445

113.14

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 4.75" Length)

1440

130435

90.58

... More
Fasteners for Flanges 3/4" x 600# (0.625" Dia. X 4.0" Length)

616

57565

93.45

... More
Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
WNRF-150#

-

-

-

... More
8", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2

12

32953

2746.09

... More
6", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2

6

10214

1702.48

... More
1", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2

40

11062

276.56

... More
WNRF-600#

-

-

-

... More
30", WNRF FLANGE, ANSI - 600#-ASTM A694 F70 -ASME B 16.47 Series A

1

46638

46638.47

... More
24", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A694 70

11

410418

37310.77

... More
16", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A694 F65

1

23693

23693.55

... More
14", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A694 F60

10

203146

20314.61

... More
12", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A694 F70

20

299534

14976.71

... More
8", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

54

628029

11630.17

... More
6", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

60

470739

7845.66

... More
4", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

90

337736

3752.63

... More
3", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

10

18757

1875.79

... More
2", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

265

240686

908.25

... More
1", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

14

8198

585.62

... More
3/4", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

220

81268

369.4

... More
BLRF

-

-

-

... More
600#

-

-

-

... More
24", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A105

1

48568

48568.88

... More
14", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A105

1

23455

23455.71

... More
12", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A105

1

22971

22971.38

... More
8", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

7

57809

8258.49

... More
6", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

4

28494

7123.68

... More
4", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

1

3889

3889.08

... More
2", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

65

51747

796.11

... More
1", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

20

8768

438.42

... More
3/4", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

1

492

492.45

... More
SPECTACLE BLINDS:Supply and delivery of following mentioned Spectacle Blinds at respective stations as per Station wise Break up of material supply and as per technical specifications indicated in tender docuemnts.

-

-

-

... More
600#

-

-

-

... More
24" Spectacle Blind 600# F/F R/F - ASTM A105

4

474422

118605.6

... More
14" Spectacle Blind 600# F/F R/F - ASTM A105

4

276746

69186.6

... More
12" Spectacle Blind 600# F/F R/F - ASTM A105

8

474423

59302.95

... More
8" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

12

417422

34785.22

... More
6" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

11

236324

21484.05

... More
4" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

12

165713

13809.49

... More
3" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

1

10357

10357.12

... More
2" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

21

176221

8391.5

... More
1" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

1

3962

3962.82

... More
3/4" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

1

2972

2972.12

... More
Supply and delivery of API 6D Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
API 6D BALL VALVE

-

-

-

... More
2" W/W ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCB

4

88191

22047.87

... More
2" F/F ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCB

4

87072

21768.21

... More
BS 5351 Ball valve

-

-

-

... More
1" W/W ANSI 800# A/G, BALL VALVE- BS 5351-ASTM A350 LF2/ASTM A352 LCB

29

314560

10846.93

... More
3/4" W/W ANSI 800# A/G, BALL VALVE-ASTM A350 LF2/ASTM A352 LCB

122

992494

8135.2

... More
BS-1873 Globe valve

-

-

-

... More
600#

-

-

-

... More
8",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

13

2532293

194791.8

... More
6",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

8

647438

80929.8

... More
4",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

3

159514

53171.36

... More
2",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

22

466307

21195.79

... More
PSV

-

-

-

... More
1"x2"x600# x150# PSV -ASTM A350 LF2/ASTM A352 LCB

8

240000

30000

... More
Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
Un Equal Tee

-

-

-

... More
600#

-

-

-

... More
24"x16" 600# (0.625" x 0.438") -Unequal Tee-WPHY-70

1

29604

29604.62

... More
24"x14" 600# (0.625" x 0.438") -Unequal Tee-WPHY-70

1

29604

29604.62

... More
24"x12" 600# (0.625" x 0.406") -Unequal Tee-WPHY-70

2

59209

29604.62

... More
24"x 8" 600# (0.625" x sch.80) -Unequal Tee-WPHY-70

3

88813

29604.62

... More
14"x8" 600# (0.438" x Sch.80) -Unequal Tee-WPHY-60

2

20606

10303.02

... More
14"x6" 600# (0.438" x Sch.80)-Unequal Tee-WPHY-60

4

41212

10303.02

... More
10"x8" 600# (Sch 80 x 80) Unequal Tee-ASTM A420 Gr.WPL6

1

12616

12616.5

... More
8"x6" 600# (Sch 80 x 80) Unequal Tee-ASTM A420 Gr.WPL6

1

6261

6261.15

... More
6"x4" x 600# (Sch 80x 80) Unequal Tee-ASTM A420 Gr.WPL6

4

18782

4695.6

... More
4"x3" 600# (Sch 80x 80) Unequal Tee-ASTM A420 Gr.WPL6

1

1276

1276.31

... More
4"x2" 600# (Sch 80x 160) Unequal Tee-ASTM A420 Gr.WPL6

4

5105

1276.31

... More
3"x2" 600# (Sch 80x 160) Unequal Tee-ASTM A420 Gr.WPL6

4

4104

1026.16

... More
2"x3/4" 600# (Sch 160x 160) Unequal Tee-ASTM A420 Gr.WPL6

122

60592

496.66

... More
Equal Tee

-

-

-

... More
600#

-

-

-

... More
24" 600# Equal Tee (0.625" x 0.625") WPHY-70

2

39608

19804.08

... More
14" 600# Equal Tee (0.438" x 0.438") WPHY-60

1

14982

14982.78

... More
12" 600# Equal Tee(0.406" x 0.406") -WPHY-70

2

31259

15629.76

... More
8" 600# Equal Tee (Sch 80 x 80)-ASTM A420 Gr.WPL6

8

49894

6236.79

... More
6" 600# Equal Tee (Sch 80 x 80)-ASTM A420 Gr.WPL6

4

8378

2094.54

... More
4" 600# Equal Tee (Sch 80 x 80)-ASTM A420 Gr.WPL6

7

9256

1322.4

... More
2" 600# Equal Tee (Sch 160 x 160)-ASTM A420 Gr.WPL6

24

9632

401.34

... More
1" 600# Equal Tee(Sch 160 x 160)-ASTM A420 Gr.WPL6

8

2984

373.12

... More
3/4" 600# Equal Tee(Sch 160 x 160)-ASTM A420 Gr.WPL6

8

2238

279.84

... More
Elbow-90 deg LR Bends

-

-

-

... More
600#

-

-

-

... More
24" 600# 90 deg LR Bend (0.625" WT)-WPHY 70

10

173164

17316.45

... More
14" 600# 90 deg LR Bend (0.438" WT)-WPHY 60

10

104046

10404.65

... More
12" 600# 90 deg LR Bend (0.406" WT)-WPHY 70

10

92649

9264.99

... More
8" 600# 90 deg LR Bend (Sch 80 )-ASTM A420 Gr.WPL6

55

178539

3246.17

... More
6" 600# 90deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

40

96326

2408.16

... More
4" 600# 90deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

46

72226

1570.15

... More
3" 600# 90 deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

6

7181

1196.84

... More
2" 600# 90deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

96

42976

447.67

... More
1" 600# 90deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

31

8258

266.4

... More
3/4" 600# 90deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

16

3196

199.8

... More
Elbow-45 deg LR Bends

-

-

-

... More
600#

-

-

-

... More
24" 600# 45deg LR Bend (0.625" WT)-WPHY 70

1

8658

8658.23

... More
14' 600# 45deg LR Bend (0.438" WT)-WPHY 60

1

5446

5446.67

... More
12" 600# 45deg LR Bend (0.406" WT)-WPHY 70

1

5121

5121.19

... More
8" 600# 45deg LR Bend (Sch 80 )-ASTM A420 Gr.WPL6

2

3411

1705.62

... More
6" 600# 45deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

1

1697

1697.67

... More
4" 600# 45deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

3

2311

770.48

... More
3" 600# 45deg LR Bend (Sch 80)-ASTM A420 Gr.WPL6

2

1155

577.86

... More
2" 600# 45deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

5

1926

385.24

... More
1" 600# 45deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

5

963

192.62

... More
3/4" 600# 45deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

5

722

144.47

... More
Concentric Reducers

-

-

-

... More
30"X24" 600# Concentric Reducer-(Sch. 0.812 X 0.625) WPHY 70

1

17723

17723.43

... More
10"X8" 600# Concentric Reducer-(Sch. 80 X 80) ASTM A420 Gr.WPL6

1

5907

5907.81

... More
8"X6" 600# Concentric Reducer-(Sch. 80 X 80) ASTM A420 Gr.WPL6

1

4209

4209.45

... More
6"X4" 600# Concentric Reducer-(Sch. 80 X 80) ASTM A420 Gr.WPL6

3

9472

3157.35

... More
Half coupling (Sockolet) & Nipple

-

-

-

... More
1" 6000Lb Nipple-ASTM A350 LF2

5

811

162.28

... More
1" 6000Lb HALF COUPLING -ASTM A350 LF2

5

806

161.21

... More
Weld-o-let

-

-

-

... More
600#

-

-

-

... More
24"X2" 600# (0.625" WT x Sch. 160) W-o-L-ASTM A350 Gr.LF2, CL 1

26

203803

7838.59

... More
14"X2" 600# (0.438" WT x Sch. 160) W-o-L-ASTM A350 Gr.LF2, CL 1

14

64015

4572.51

... More
12"X2"600# (0.406" WT x Sch. 160) W-o-L-ASTM A350 Gr.LF2, CL 1

10

32850

3285.08

... More
8"X2"600# (Sch 80 x 160) W-o-L-ASTM A350 Gr.LF2, CL 1

14

38805

2771.8

... More
6"X2" 600# (Sch 80 x 160) W-o-L-ASTM A350 Gr.LF2, CL 1

24

67485

2811.9

... More
4"X2" 600# (Sch 80 x 160) W-o-L-ASTM A350 Gr.LF2, CL 1

12

22495

1874.6

... More
Supply of API 5L/ ASTM A333 Gr.6 pipes at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
12.75" OD x 0.406" WT API 5L X70

50

381684

7633.68

... More
8.625" OD x Sch.80 ASTM A 333 Gr. 6 PIP

295

908535

3079.78

... More
6.625" OD x Sch.80 ASTM A 333 Gr. 6 PIP

220

520438

2365.63

... More
4.50" OD x Sch.80 ASTM A 333 Gr. 6 PIPE

250

379290

1517.16

... More
3.5" OD x Sch.160 ASTM A 333 Gr. 6 PIPE

50

49665

993.3

... More
2.375" OD x Sch.160 ASTM A 333 Gr. 6 PIP

320

190144

594.2

... More
1.315" OD x Sch.160 ASTM A 333 Gr. 6 PIP

175

59010

337.2

... More
1.050" OD x Sch.160 ASTM A 333 Gr. 6 PIP

155

41733

269.25

... More
FIRE FIGHTING EQUIPMENT: Supply and delivery of Fire Fighting Equipment at respective stations as per Station wise Break up of material supply and as per techhnical specifications indicated in tender documents.

-

-

-

... More
9 kg DCP Extinguisher- IS 15683 marked

8

29552

3694.05

... More
4.5 kg CO2 Extinguisher- IS 15683 Marked

4

23797

5949.45

... More
2 kg CO2 Extinguisher- IS 15683 Marked

4

18823

4705.97

... More
2 kg clean agent extinguishers IS 15683 Marked

4

39907

9976.95

... More
Fire Hose Box for keeping 2 Nos. of 15 M Type B delivery hose and one no. jet nozzle

8

29312

3664.08

... More
Type B Delivery Hoses of 15 M length bearing IS-636 marked

4

25950

6487.71

... More
Jet Nozzles IS marked

2

7521

3760.83

... More
Fog Nozzle

2

11043

5521.8

... More
Universal Nozzle

2

9346

4673.02

... More
Foam Branch pipe FB-5x

2

11730

5865.34

... More
Water curtain nozzle

2

3968

1984.21

... More
Sand drum with scoop

4

8151

2037.95

... More
Pair of Rubber hand gloves for Electrical work bearing IS mark

16

16307

1019.21

... More
First Aid Box with Snake serum

14

21501

1535.84

... More
Sand Bucket

4

1313

328.43

... More
Safety Helmet

44

13061

296.86

... More
Strecher with blanket

4

17002

4250.52

... More
Explosimeter

2

62102

31051.2

... More
Portable oxygen LEL meter

2

40000

20000

... More
Rescuscitor

2

12425

6212.85

... More
Hand Operated siren

2

25533

12766.71

... More
Wind socks

4

11071

2767.96

... More
Red & Green flag (Pairs) 2 nos in each colour

4

4870

1217.62

... More
Extinguisher box for 9 kg DCP Extinguishers

8

31858

3982.29

... More
Dry Chemical Powder silliconised potasium bicarbonate type IS marked, pack of 10 KG

10

2714

271.49

... More
CO2 cartridge - 200 gm capacity for 9 kg capacity DCP extinguisher

2

1036

518.03

... More
Water gel blanket

2

25270

12635.14

... More
Positive Pressure type self containing Breathing Apparatus

2

10667

5333.53

... More
Fire Proximity suit

2

10667

5333.53

... More
PCV suit

14

74669

5333.53

... More
Ear plug

28

4200

150

... More
Ear muff

32

14400

450

... More
Loud hailer/ megaphone

2

53335

26667.67

... More
Safety Torch

14

53523

3823.08

... More
Cotton hand gloves

210

31500

150

... More
Low temparature rubber hand gloves

8

53114

6639.25

... More
Low temparature protective clothing

4

1263086

315771.73

... More
Flame Arrestor:Supply and delivery of following mentioned Flame Arrestor at respective stations as per Station wise Break up of material supply and as per technical specifications indicated in tender docuemnts.

-

-

-

... More
8" Flame Arrester

5

1673320

334664

... More
6" Flame Arrester

3

752994

250998

... More
4" Flame Arrester

1

167332

167332

... More
II INST SUPPLY CSW

-

-

-

... More
Pressure Indicators (PI) of the following ranges as per the technical specifications attached in the Tender.

-

-

-

... More
"Range: 0 to 1 kg/CM2."

7

25952

3707.56

... More
Range: 0 to 100 kg/cm2

41

173480

4231.23

... More
" Gauge Saver (0-1 Kg/Cm2) as per the technical specifications as per tender.

7

12600

1800

... More
"FLP/ WP Junction Box, Type D. Bottom entries: 1 No. 1# NPT (suitable for 12CX1.5sqmm) Left side entries: 3 nos. ½# NPT (suitable for 4CX1.5sqmm) Right side entries: 3 nos. ½# NPT (suitable for 4CX1.5 sqmm) "

26

85154

3275.17

... More
"FLP/ WP Emergency Shut Down Push Button Switch (with 2 nos. cable entry provision of 1/2"" NPT) with steel hammer chained with main unit.

1

1571

1571.84

... More
FLP/ WP cable Glands (Suitable Sizes)

-

-

-

... More
1 1/4" (5/4") Suitable for 40 C X 1.5 mm control & 8Tx1.5 Sqmm triad cable.

8

2667

333.46

... More
1" Suitable for 12C X 1.5 mm control & 5Px 1.5 mm signal cables.

14

3031

216.51

... More
1/2" Suitable for 4C X1.5 mm control, 2Px 1.5 mm signa & 1Tx 1.5 Sqmm triad cable.

28

2541

90.76

... More
FLP/ WP Plugs (Suitable Sizes)

-

-

-

... More
1 1/4" FLP/ WP Plugs

2

125

62.96

... More
1" FLP/ WP Plugs

28

1762

62.96

... More
1/2" FLP/ WP Plugs

28

867

30.97

... More
FLP/ WP Reducers (Suitable sizes)

-

-

-

... More
3/4" to 1/2" FLP/ WP Reducers

4

835

208.85

... More
1" to 1/2" FLP/ WP Reducers

6

1033

172.2

... More
CHEQUERED PLATE Supply and placing in position 5 mm thick steel checkered plates over cable ducts, valves, pits etc including keeping provision of holes for lifting arrangement as per drawing complete in all respect inclusive of cost of all labour, material, carriage etc as per specification & the direction of the engineer in-charge/site engineer

5

22265

4453.19

... More
GI CONDUIT FOR BUILDING WIRING 19 mm ISI marked GI conduit along with all fittings & fixtures like Tees, bends, junction boxes, etc for wiring in buildings

180

67116

372.87

... More
Instruments SS Fittings & Tubings

-

-

-

... More
TUBE 1/2" OD (M)

273

360329

1319.89

... More
Bushing 3/4" Butt Welded x 1/2" FNPT

99

201947

2039.87

... More
Male Connector 1/2" MNPT x 1/2" OD Tube

301

291693

969.08

... More
Female Connector 1/2" FNPT x 1/2" OD Tube

24

33338

1389.09

... More
1/2" OD Tube End cap

64

43264

676.01

... More
Union Tee 3 x 1/2" OD Tube

40

276833

6920.83

... More
2 Way Valve Manifold 2 x 12.7 MM FNPT, Material : SS316 with blanking plug for each port.

64

654019

10219.06

... More
Nipple 1/2" MNPT x 1/2" MNPT, 150 mm long

22

25811

1173.24

... More
Scrapper Detector Switch (24" 600#), Type: Vane, Body Material: Stainless steel, End connection: Flanged, Switch action: DPDT, Voltage:24 VDC, Current: 1A complete as per tender specifications

2

121982

60991.07

... More
Scrapper Detector Switch (14" 600#), Type: Vane, Body Material: Stainless steel, End connection: Flanged, Switch action: DPDT, Voltage:24 VDC, Current: 1A complete as per tender specifications

1

64682

64682.89

... More
Jacking Bracket for 600# Scrapper Detectors complete as per tender specifications

1

45847

45847.24

... More
III OFC AND TELECOMM SUPPLY CSW ML

-

-

-

... More
Supply of OFC Jointing kits as per tender specifications.

113

775858

6866

... More
Supply of Electronic Marker Locator cum Cable/ Pipe Locator, Fault Locator as per tender specifications

1

227061

227061

... More
Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications

111

195138

1758

... More
Supply of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications

130

273910

2107

... More
Supply of Joint pit markers for OFC joint locations as per tender specifications

111

308358

2778

... More
Supply of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications

111

1101675

9925

... More
Supply of Transition pits for building entry points as per tender specifications

9

91224

10136

... More
Supply of wall mounted Fibre Termination Box (FMS) as per tender specifications IP/SV+RWS- 1 each

1

11878

11878

... More
Supply of spare OFC Jointing kits at IP/SV+RWS

10

68660

6866

... More
Supply of spare RF ID type Electronic Markers at IP/SV+RWS

10

17580

1758

... More
2 Pair unarmoured Telephone Cable as per specifications

1500

73500

49

... More
20 Pair Armoured PIJF Underground Telephone Cable as per specifications

1000

145000

145

... More
5 Pair Armoured PIJF Underground Telephone Cable as per specifications

700

64400

92

... More
Cat 6 UTP (LAN) Networking Cable as per tender specifications

1500

31500

21

... More
Wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O. The item includes modular plate & switch box/ gang box for fixing the face plate.

66

19734

299

... More
Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate IP-50, SV+RWS-25.

50

20700

414

... More
Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications at IP & SV+RWS

1

38186

38186

... More
24 Port L2 Network Switch with Optical Interfaces as per tender specifications at IP & SV+RWS

1

142913

142913

... More
Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications

1000

96000

96

... More
600 VA UPS with 15 minutes battery back-up for LAN switch at IP /SV+RWS

1

6860

6860

... More
IV OFC AND TELECOMM SUPPLY MAINLINE

-

-

-

... More
V ELECTRICAL SUPPLY CSW

-

-

-

... More
SAFETY EQUIPMENT Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge

-

-

-

... More
RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.

18

51257

2847.63

... More
"INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per specifications."

-

-

-

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)

90

191156

2123.96

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)

29

70351

2425.93

... More
Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest)

45

260404

5786.76

... More
Supply of fully charged CO2 fire extinguishers as per specifications (2 kg capacity as per IS: 2878 latest)

45

178848

3974.4

... More
Supply of fire buckets mounted on stand

45

134172

2981.62

... More
Copper Cables - 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvaznized armoured, PVC type ST-2 overall sheathed, Stranded

-

-

-

... More
3C x 2.5 mm² FRLSH

450

27508

61.13

... More
2C x 4 mm², FRLSH

300

19515

65.05

... More
4C x 4 mm² , FRLSH

80

8955

111.94

... More
3C x 6 mm² , FRLSH

450

56101

124.67

... More
2C x 10 mm² FRLSH

450

63535

141.19

... More
Aluminium Cables - 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvaznized armoured, PVC type ST-2 overall sheathed, Stranded

-

-

-

... More
4C x 16 mm² , FRLSH

3600

269064

74.74

... More
3½C x 25 mm² FRLSH

3600

356292

98.97

... More
3½C x 50 mm², FRLSH

3600

494280

137.3

... More
3½C x 95 mm² , FRLSH

3600

1160496

322.36

... More
ACDB Panel

-

-

-

... More
ACDB Panel as per technical specifications IOCL-PL-ELEC-LVSB-22

9

2272441

252493.53

... More
Silent Diesel Generating Set : Supply of Silent Type DG set alongwith processor based AMF panel, Industrial Lead-Acid Batteries for Starting of DG Set, Acoustic Enclosure, exhaust piping with its support structure,fuel tank, etc., as given in the technical specification IOCL-PLELEC-LVDG-14 complete in all respects

-

-

-

... More
25 KVA, 3-Phase, 415 V

8

3686536

460817.04

... More
50 KVA, 3-Phase, 415 V

1

921634

921634.09

... More
Supply of high mast tower as per technical specification enclosed IOCL-PL-ELEC-HMT-1.0. The job includes supply of (1) 30 M high mast structure with lantern carriage with raising/lowering mechanism by FLP motor, min. steel plates sheet thickness shall be 5 mm (2) LED flood light fixtures & lamps- 350 W (120 Lumens/W min. efficiency) - 12 nos. & LED Aviation obstruction lights - 02 nos. (3) Lightning arrestor-1200 mm length finial (4) FLP feeder pillar board with cables from feeder pillar to base compartment of high mast (5) Foundation bolts. The vendor will submit the foundation design based on soil strata (soil report shall be provided by IOCL) of locations. Further vendor shall provide supervision for testing & commissioning of high Mast

-

-

-

... More
High Mast Shaft with cables, FLP/WP motor, cables and accessories - For 30 M Height

12

5453377

454448.1

... More
Foundation bolts with anchor plate & common template for high mast tower (30M Height)

12

195926

16327.2

... More
LED flood light type -350 W (12 nos.) & Aviation obstruction LED light - 02 nos.

12

4361328

363444.07

... More
Outdoor stand mounted FLP/WP feeder pillar

12

1418503

118208.62

... More
Electrical resistance based corrosion monitoring system consisting of following items:-

-

-

-

... More
Access fittings flareweld

1

17315

17315

... More
Hollow Plug assembly

1

12855

12855

... More
Heavy Duty Protective Cover

1

11175

11175

... More
Primary Packing for Hollow Plug Assy

1

500

500

... More
Probe extension adapter

1

18930

18930

... More
Retrievable flush ER probe

1

50335

50335

... More
Receiver with Safety Barrier, 3 digit LED display, suitable for interfacing with SCADA as per specification

1

286880

286880

... More
Transmitter (intrinsically safe) as per specification including 5m suitable cable for connection with ER probe.

1

236550

236550

... More
Supply of SPV based LED street light (panel, battery, LED) - Su-Kam Sunway LI5 (40W) GSM or equivalent (refer technical specifications) at site approved by EIC and complete in all respects

360

10118703

28107.51

... More
VI ELECTRICAL PCP SUPPLY MAINLINE

-

-

-

... More
"PERMANENT CATHODIC PROTECTION SYSTEM Supply of materials/equipments as given below complete in all respects, as per the specification as detailed in the tender document including transportation to site and storing :"

-

-

-

... More
Supply of Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations

-

-

-

... More
Solid State Decoupling Device

54

4166066

77149.38

... More
Supply of Zn Grounding cells ( with prepackaged backfill material) including required length of cable (minimum 10 m) of approved make & as per specification in accordance with dwg no. 9200-99900-404-611-00

-

-

-

... More
Grounding Cells

15

110843

7389.54

... More
Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings

-

-

-

... More
Surge Arrestor/ Surge Diverter

15

188935

12595.71

... More
Supply of Cathodic Protection unit of approved make, complete in all respects as given in the specification with all its accessories to ensure trouble free operation

-

-

-

... More
230V AC cum (-) 48V DC Operated automatic type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V, 25 A DC with with DC-DC converter & SCADA linkage facility as per specifications

5

1816110

363222.19

... More
Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc.

-

-

-

... More
Junction Box having IP-55 degree of protection

10

185172

18517.25

... More
Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as given in technical specifications

-

-

-

... More
DC distribution board with one incomer, 100 A DP MCB & outgoing feeders 1x63A DP MCB & 2x32 A DP MCB

5

96523

19304.6

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make

-

-

-

... More
Copper Cable size 1cx35 sq. mm Armoured

2500

808125

323.25

... More
Copper Cable size 1cx25 sq.mm Armoured

500

116485

232.97

... More
Copper Cable size 2cx6 sq.mm Armoured

2550

388569

152.38

... More
Copper Cable size 2cx25 sq.mm Armoured

500

226710

453.42

... More
Copper Cable size 2cx70 sq.mm Armoured

50

22671

453.42

... More
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make

17

136508

8029.9

... More
Supply of Pipe cum cable locator of approved make as per specifications complete in all respects

1

255885

255885.46

... More
Supply of hand held data logger for ON/OFF PSP measurement alongwith carrying case, data downloading cable and other required accessories complete as per specifications and approved make

1

127942

127942.73

... More
IP 101 IP102 Civil Comp ITC TAMILNADU

-

-

-

... More
I CIVIL Work

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by the Engineer-in-Charge. a) All kinds of soil

558

66697

119.53

... More
CONCRETE WORK :

-

-

-

... More
CEMENT CONCRETE (CAST IN-SITU) :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size)

38

161492

4249.81

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III): 3 graded stone aggregate 20 mm nominal size)

340

2005466

5898.43

... More
STEEL REINFORCEMENT :

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

41590

2233798

53.71

... More
STEEL WORK :

-

-

-

... More
Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer#s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work).

10.16

1028182

101199.1

... More
FINISHING

-

-

-

... More
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)

498

67962

136.47

... More
EQUIPMENT FOUNDATION WORKS :

-

-

-

... More
Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer's recommendation/ specification and direction of the Site Engineer. (Note: This item shall be operated under specific instruction of the Engineer-in-Charge.)

7853

441103

56.17

... More
IP 101 IP102 OFCTEL Non ITC TAMILNADU

-

-

-

... More
I COMPOSITE

-

-

-

... More
Supply and Installation of GI Pipe of 100 mm nominal bore heavy class as per IS1239, sub ducted by 40 mm OD HDPE pipe (excluding supply of HDPE pipe), by boring or jacking method across railway / road crossing, including all necessary pipe fittings, cost of arranging boring machine, other associated machinery, tools, tackles, skilled manpower, labour etc. job complete in every respects as per the directions of Engineer-in-charge/ Site Engineer. Measurement shall be done by the length of the GI pipe used in the crossings

48

225072

4689

... More
II SUPPLY

-

-

-

... More
Supply of permanently-lubricated HDPE pipe of 40 mm OD (as per TEC GR) with minimum pressure rating of 6 Kg/cm2 and wall thickness of 3.5 mm, along with duct accessories such as couplers, end caps, end sealing plugs, warning tape etc. as per specifications.

131

7122470

54370

... More
Supply of 89 mm OD, Schedule 80, API 5L Grade-B/ ASTM A106 MS pipe for cable conduit as per tender specifications at HDD

3780

5095440

1348

... More
Mainline IP 101 IP102 No ITC 1 PUDUCHERY

-

-

-

... More
1. MAINLINE WORKS

-

-

-

... More
Mainline laying works i) 30" OD Pipe Haldia-Barauni Section "Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Owner's ROU/ROW, required for Contractor's storage, fabrication, access for construction site, movement of construction equipment etc., receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner's issue point to work site, stringing along Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works:- - Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed inside stockpile by mainline contractor shall be done by Owner's authorized agency), including placing of pipe trailors for taking delivery of pipes from designated stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), transportation of pipes to ROW/ work site/ Contractor's storage location etc., - Clearing and grading of ROW/ pipeline corridor, cutting of trees, vegetation etc. including keeping record of trees cut, including de-watering etc., - Stringing of pipes along ROW including providing straw bags/ soft padding below pipe (in Rocky areas requiring blasting for preparation of trench, pipes shall be strung after the blasting operation and clearing of trench as per instructions of Site Engineer/ Engineer-in-Charge), - Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this material separately along the ROW to allow re-depositing of the same on top of the backfilled ditch (in cultivable and other areas specially designated by Owner), - Carrying out repair of pipe & coating defects for defects occurring after ""taking over"" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling, - Aligning, bending, lining up, cutting and beveling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints found defective, - (For all pipelines except LPG/Gas) Carrying out 100% radiographic inspection (by X-Ray)of all field weld joints for initial 1(one) Km in each Mainline Spread, Crossings and other specific locations as per Specifications and Special Conditions of Contract (SCC) and 20% radiographic inspection (by X-Ray) for the balance portion (excluding crossings and other specific locations) and destructive testing of one weld joint in each Spread as per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray machine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector), providing all facilities to Owner's representative(s) for examining radiographs and other tests as required, carrying out repair of weld-joints found defective, carrying out re-radiography and other tests as required on repaired joints, etc., - Carrying out coating of all field weld joints, by qualified coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables necessary to carry out the job as per manufacturer's recommendation, - Installation of hot-pulled bends at required locations in mainline (bends to be fabricated from Owner-supplied bare pipes) including cutting, beveling, fitment, coating the bare bend pipe with approved PU coating, - Carrying out holiday detection, at specified voltage level corresponding to coating type and as per specifications, and repair of coating, if any, -Laying pipeline by open-cut method at crossings viz., cart-track, village road, metalled/ un-metalled roads, minor water courses (MWC) etc.,(except crossings identified as ""Cased"", ""Submerged"" & ""HDD"" crossings ) and restoration of the crossing site to original condition including performance of additional works for strengthening of banks of water courses etc., - Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soil (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer, - Carrying out air cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline (excluding those HDD crossing sections not under the scope of this tender) including providing 'pre-testing' of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, if any, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline section after successful hydrotesting, - All tie-ins, including tieing-in with HDD sections under this tender and also with HDD sections not covered under this tender (tie-ins with HDD sections not under this tender shall be paid separately as per relevant item of SOR), - Obtaining work permits/ NOC from various authorities having jurisdiction before execution of work and complying with all stipulations/ conditions/ recommendation of the said authorities - Supply and installation of 1.0 mm thickness & width (D+300) warning tape over entire pipeline as per relevant specification - Final clean-up and restoration of ROW/ construction corridor, field bunds etc., obtaining NOC from statutory authorities (as required) and obtaining NOC from respective land owners in respect of final restoration of their land etc, disposal of debris and returning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, facilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction, - Preparation of as-built drawings, pipe book and other records as per specifications etc., - Supply of all materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for performance of work or for temporary or permanent incorporation in the works, and - All other acts, deeds, matters and things necessary to make the pipeline ready for commissioning and completing the works in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charge. NOTE: I) The rate quoted against this item shall include cost of excavation and backfilling of trench of standard width (as per approved drawings) in all kinds of soil for laying Mainline pipe. II)The Mainline work includes and covers the work in all types of crossings viz., roads, drains, minor water courses (MWC), low lying areas, ponds, plant area, underground utilities, pedestrian crossings, etc. except those crossings identified as ""Cased"", ""Submerged"" & ""HDD"" crossings for which relevant item of SOR shall be applicable. III) Concrete coating, if necessary, for laying pipelines across ponds, low lying areas etc. shall be paid separately as per relevant item of SOR. IV) Cost of all materials required in repair and/ or rectification of defective work caused due to reasons not attributable to any act or omission of the Owner shall be chargeable to Contractor account. The Owner will supply the additional materials from its designated store/ godown (insofar as constitutes Owner-supplied materials) required for the repair/ rectification work on chargeable basis. The cost of such material shall be as determined by the Engineer-in-Charge plus an additional charge of 15% of the cost of material shall also be levied. The decision of the Engineer-in-Charge, as to the cost of the material, shall be final and binding on the Contractor. VI) In the course of hydrostatic testing of the mainline section, if any defective portion/ pipe/ work is found to be due to a defect in the pipe attributable to the Owner, the Owner shall supply the additional necessary pipes at Owner issue point required for the work free of cost to the Contractor, but the Contractor shall supply all other materials and inputs at his own cost for replacement of pipe section. The Contractor shall be paid a lump sum amount for each such failure (refer relevant clause of Special Conditions of Contract of the tender documents) for the work involved in locating & identifying the defects in the mainline and in their repair/rectification as per the specification. Failure in one or more pipes in a section during a single pressurization cycle shall be considered as a single failure for the purpose of compensation for hydrostatic test failure on account of manufacturing defect. VII) Installation of the hot-pulled bends in Mainline, including cutting beveling of pipes, fitment etc., shall be inclusive in the Mainline rate. Payment for fabrication of hot-pulled induction bends, as per specifications, shall be done separately as per relevant item of SOR. The hot-pulled bends shall be coated at site with PU coating. The cost of the same shall be deemed to be included in this item for Mainline laying.

-

-

-

... More
14" OD Pipe Laying

1460

5080800

3480

... More
Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all works ,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contract, including taking delivery and transportation of Owner-supplied coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position, arranging the required additional land for construction purpose, preparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting (both pre- & post-installation) and replacement of pipes/ defects, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering including installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing ""Band IT"" make stainless steel (SS) strips / clamps of 3/4"" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and final clean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Engineer-in-Charge. NOTE : I)Depending upon the site condition & location of each submerged crossing, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/ drain/ rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. II)Profile of drain / canal bed, ground & top of laid pipe shall be established jointly in presence of Owner both before and after laying the crossing, by taking levels with reference to nearby permanent structure. III)The banks of the crossing shall be stabilised and suitable brick/ stone masonry bank protection works shall be carried out for the entire ROW width to prevent bank erosion leading to exposure of the pipeline. The procedure for such measures shall be submitted for Owner's approval prior to execution. IV)Concrete sheathing work for submerged crossings shall be paid for separately under relevant item of Schedule of Rates."

-

-

-

... More
14" OD Carrier Pipe

310

5033160

16236

... More
Mainline IP 101 IP102 No ITC 2 PUDUCHERY

-

-

-

... More
1 MAINLINE WORKS

-

-

-

... More
Concrete Sheathing / Coating (100 mm thk

-

-

-

... More
Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) of 50mm thick in two layers using specified (approved) wire mesh reinforcement as per approved dr awing and technical specifications, including supply of cement, steel wire mesh, aggregate, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, testing of concrete coated pipes etc. and as per direction of Engineer-in-Charge. NOTE: I) Payment shall be made for the actual length of pipe coated with concrete. Ends of pipe left uncoated/ shall not be considered in the concrete coating length II) The rates shall include compensation for additional hardship caused in handling and/ or lowering the pipe with concrete coating. The above item shall be executed at the discretion and directions of Engineer-in-Charge. III) The rates shall include the concrete sheathing / coating over weld joints in order to arrive at continuously concrete coated pipeline. This weld joint concrete sheathing / coating shall be applied after the hydrostatic pre-test.

310

1220780

3938

... More
SAND PADDING ( IN OTHER AREAS) Supplying, providing and filling fine sand in trenches in stretches other than normal soil and hard rock / boulder stretch (including additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bottom of the mainline pipe for the complete specified trench width NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be included in this item itself

-

-

-

... More
14" OD

500

368500

737

... More
Pipeline MArkers Supply of all materials necessary for fabrication and installation of kilometre posts, direction markers and warning signs at the locations as per specifications, excavating & grouting in cement concrete 1:3:6, and all other works necessary for fabrication & installation of the markers including cleaning, priming & applying two coats of coal tar based epoxy paint on underground portions, supply and application of one coat of primer and two coats of epoxy paint of approved colour and quality on overground portion, stencil letter cutting for number, direction, chainage etc. and restoration of site to original condition and all other acts, deeds, matters and things and work, labour, inputs and materials/ consumables necessary to perform and complete the work in all respects as per approved drawing & specifications and as per direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Kilometer post

2

14960

7480

... More
Direction marker

22

159478

7249

... More
Warning sign

2

17336

8668

... More
Boundary Pillars Providing and installing RCC (1:1.5:3) boundary pillars as per drawings on both edges of the ROW at 250 metres interval and at every turning point and/or as directed, including supply of all materials necessary for the fabrication of the pillars, casting and inscribing the pillars, excavation of earth, fixing the pillars & backfilling, applying two coats of oil paint over one coat of cement based primer on exposed surface and work, labour, inputs & materials/ consumables necessary to perform and complete the work in all respect under the contract and as per directions of Site Engineer.

30

49500

1650

... More
AIR DRYING (OPTIONAL) Carrying out air drying of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
14" OD

2

79750

39875

... More
NITROGEN PURGING (OPTIONAL) Carrying out Nitrogen Purging of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
14" OD

2

62480

31240

... More
H"ELECTRONIC GEOMETRY PIGGING (EGP) / CALLIPER SURVEY (INCLUDING MAGNETIC PIGGING)/ Mobilisation/ demobilisation of pigging tools, tackles, consumables, accessories and personnel by contractor at work site including magnetic pig, electronic geometry pig, pig tracking device, preparation and cleaning of the complete mainline / Mainline sections including HDD sections under this tender by running series of pigs for cleaning the line from debris, water & making it dry for launching calliper pigs, running of magnetic pig for cleaning of ferrous residue, launching and receiving the electronic & standard calliper pigs, including pig tracking at 2 to 3 km interval, data retrieval, interpretation of data and submission of reports in the form acceptable to the Owner, including rectification of defects observed from calliper survey, including supply of all labour, materials, equipment & instruments, calliper pigs, fabrication of launching & receiving barrels, all complete for ascertaining the geometry of the pipeline. "

-

-

-

... More
14" OD

2

62612

31306

... More
Commissioning Assistance (for R-LNG Pipeline) Commissioning assistance: Supply of all materials, consumable, providing all equipemnet & resource for the complete activitiy of commissioning of R-LNG pipeline including mainline & station Pipeline with proper pressurization of mainline and station piping with Nitrogen, bacth pigging followed by vaporised R-LNG and effective line fill by pressurization of line fill with R-LNG as per approved procedure and specification requirement i ncluding providing expert services for vetting of commissioning procedure and presence of experts to guide & monitor the complete commissioning activities with proper satisfaction to EIC. Note: This Item shall be operated with prior permission from EIC.

-

-

-

... More
14" OD

2

24596

12298

... More
IP 101 IP102 Civil Comp No ITC PUDUCHERY

-

-

-

... More
1. COMPOSITE CIVIL- NON ITC

-

-

-

... More
EARTHWORK :

-

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.,, -All kinds of soil.,,

10

491

49.11

... More
PILE WORK :

-

-

-

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynamic method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-In-Charge.] :,, Single pile up to 50 tonne Safe Capacity :,, Initial Test (Test Load 2.5 times the Safe Capacity),,

3

109786

36595.55

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynamic method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-In-Charge.] :,, Single pile up to 50 tonne Safe Capacity :,, Routine Test (Test Load 1.5 times the Safe Capacity)

3

49602

16534.13

... More
IP 101 IP102 Composite ITC PUDUCHERY

-

-

-

... More
I MECHANICAL WORK COMPOSI CSW

-

-

-

... More
Supply and Erection of Structural Steel:Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.

10

954500

95450

... More
PU /liquid epoxy Coating of under ground piping: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.

60

114016

1900.27

... More
Painting: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. priming with one coat of primer and painting the surfaces with two coats as per specification, with approved materials, paints, brushes, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.

-

-

-

... More
Zinc Ethyl Slicate Primer

150

68463

456.42

... More
High Build EPOXY MIO

150

49431

329.54

... More
Isocynate Aliphatic Poly Urethene(PU)

150

62763

418.42

... More
Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping, The job includes cutting drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC. Note:- Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines.

-

-

-

... More
Up to 30 mm wide x 3 mm thick Copper str

192

111024

578.25

... More
II INST COMPOS CSW

-

-

-

... More
Taking delivery, shifting within a road distance of 500 meters and installation & testing of the following instruments (Pressure Gauge, Pressure Switch, Pressure Transmitter, Temperature Transmitters, Flow meters etc. of various types & ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables, supply and erection of all other required materials such as the supporting structure clamps ,cannopy, screws, nuts, bolts, aluminium sheets, GI wire,steel plats, cement concrete etc. complete in all respects including supply of suitable size non flame proof cable gland at control panel end and terminating the already laid cables at field, junction box and control panel end, mounting the junction boxes as per the Drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connected to the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. The scope shall include providing assistance in testing and commissioning of the instruments along with loop checking and providing assistance to control system vendor.

-

-

-

... More
INSTALLATION OF PI+PT: Installation, assistance in testing and commissioning of Pressure Gauge and Pressure Transmitter (PI+PT) of various ratings as per the directions of Engineer-in-charge/ Site engineer and drawings

2

14791

7395.89

... More
INSTALLATION OF TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of temperature elements/temperature transmitter(TT) by making necessary holes on the pipes, welding the socket for thermowell on the pipe including supply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings.

1

7307

7307.61

... More
INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of sub soil temperature lements/temperature transmitter (TT) by as per the directions of engineer in-charge/site engineer and drawings

1

10214

10214.65

... More
INSTALLATION OF EMERGENCY SHUTDOWN SWITCH: Installation and testing of emergency shut - down (ESD) Push button. This includes mounting of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour.

1

9494

9494.84

... More
Installation and testing of Scrapper Detector. This includes mounting of termination box etc as per OEM recommandations, vendor drawings, directions of engineer in-charge/site engineer and other approved drawings.

1

5142

5142.67

... More
INSTALLATION OF JUNCTION BOXES: Installation of all type of explosion proof/flame proof junction boxes, non-flame proof junction box for marshalling of control cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cement concrete, painting, GI wire etc. (excluding supply of the Junction Boxes) in all respects complete as per specifications, drawings and direction of site Engineer including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour, tools, materials, glanding, ferruling etc. complete in all respects.

3

14715

4905.24

... More
INSTRUMENTATION JOBS FOR GOVs: Carrying out the instrumentation and control system jobs on the already erected actuator assembly of Gas operated valves (GOVs), installation of GOV instrumentation tubings, fittings etc.(excluding the supply of tubings & fittings) & necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

1

5288

5288.56

... More
INSTRUMENTATION JOBS FOR HOVs: Carrying out the instrumentation and control system jobs on the already erected actuator assembly of Hydraulic operated valves (HOVs) & necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

2

7932

3966.42

... More
INSTALLATION OF CONTROL PANEL: Taking delivery, shifting the panels to installation site and erection, installation, testing of Control panels/ RTU panel, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, control desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levelling, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per drawings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all respects.The indicated quantity is cumulative weight of panels.

500

16400

32.8

... More
"STEEL STRUCTURAL WORKS: Supply, fabrication, erection and installation of steel/GI structural works of any type and shape such as cable racks, trays, push button, control posts, ladders, lugs, chain link, fencing, angles, joints, channels, plates, flats, bars etc as required as per specifications, drawings, directions of site engineer/engineer in-charge, inlcuding cost of all labour, materials, tools, consumables etc complete in all respects. Job is inclusive of taking delivery from owner's go down and shifting to site wherever required.

200

25396

126.98

... More
AIR CONDITIONERS - SPLIT TYPE: Supply & Installation of minimum 1.8 T Split Type five star BEE rated ACs along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per technical specifications and instruction of EIC / Site Engineer.

2

183058

91529.13

... More
EXPLOSION PROOF AIR CONDITIONERS - SPLIT TYPE Supply & Installation of minimum 1.8 T Explosion proof Split Type ACs along with MS stand for outdoor unit, refregerant piping, drain piping and other accessories complete as per technical specifications and instruction of EIC / Site Engineer.

1

228822

228822.83

... More
MAGNETIC PROXIMITY SWITCHES: Supply & installation of Magnetic Proximity switch for extending contact to control system for unauthorised entry of building / MOV fencing.

2

24652

12326.39

... More
INSTALLATION OF HYDROCARBON DETECTORS: Installation of Infrared Hydrocarbon detectors (point type & open path type), terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Hydrocarbon detector) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

2

7545

3772.64

... More
INSTALLATION OF HAZARDOUS AREA MCP: Installation of hazardous area Manual call points, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

1

2652

2652.49

... More
INSTALLATION OF HAZARDOUS AREA HOOTER: Installation of hazardous area hooters, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

1

2652

2652.49

... More
INSTALLATION OF HAZARDOUS AREA BEACON: Installation of hazardous area Beacons, terminating the cables at field and panel end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Points) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineer including all labour, tools, materials, glanding, ferruling etc. complete in all respects.

1

2652

2652.49

... More
INSTRUMENTATION JOBS FOR METERING SKID Carrying out the instrumentation and control system job on the already erected Metering skid,KOD,Filteration,PRS and Heating skids as applicable & necessary cable termination in the skid junction boxes at field end and control/ metering panel end (excluding the supply of cables) as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

1

7932

7932.84

... More
III OFC AND TELECOMM COMPOSI CSW ML

-

-

-

... More
IV OFC AND TELECOMM COMPOSI MAINLINE

-

-

-

... More
V ELECTRICAL COMPOSITE CSW

-

-

-

... More
Supply, installation & fixing of prefabricated perforated GI cable trays with cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

600

100284

167.14

... More
Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

111

79198

713.5

... More
Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

296

220440

744.73

... More
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

16

33502

2093.93

... More
LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

-

-

-

... More
Power cables LT : OD upto 20 mm

5

20649

4129.88

... More
Power cables LT : OD above 20 mm and upto 40 mm

5

25638

5127.74

... More
Power cables LT : OD above 40 mm and upto 60 mm

2

14773

7386.74

... More
Control cables LT : OD upto 20 mm

5

27452

5490.45

... More
"ACE Chemrod Earthing:Supply, installation, testing and commissioning of ACE (Artificial concept of earthing with chemical rod) Chemrod earthing electrode by digging earthing of 3.0 Meter depth & 150 mm diameter or higher by drilling/or any other method, placing ACE Chemrod Earthing Electrode, consisting Mild steel Galvanized pipe of size 2500 mm x 50 mm outer dia or higher size x 2 mm thick or above, Galvanized MS rod of size 2575 mmx 16 mm or higher size be welded with bottom. The epoxy insulator of not less than 100 mm length is to be filled in residual gap between pipe and rod. Highly conductive substances not less than 50 Kg are to be used for treatment of soil. Model NECO T-19 of Tosha make or equivalents of YK Trader / UniqueAssociates / Shriram make. Item includes the supply and installation of the CI/RCC cover in the earth pit, backfilling etc. and construction of chamber; complete including excavation, backfilling and supply of all materials required for making earth pit as per drawings, specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects. "

15

222945

14863.03

... More
"EARTHING PLATE : Supply & Installation of G.I. earthing plate as per drawing no. 9200-99900-404-009-00 outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels etc. and as per direction of EIC / Site engineer."

2

2782

1391.04

... More
"EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect. "

-

-

-

... More
50 mm X 6 mm G.I. earthing strip

100

25726

257.26

... More
40 mm X 5 mm G.I. earthing strip

200

35876

179.38

... More
25mm x 4 mm copper flat

50

36896

737.92

... More
25mm x 3 mm copper flat

55

30858

561.06

... More
GI wire (8 SWG)

120

6660

55.5

... More
GI wire / rope 35 sq. mm

50

5552

111.04

... More
GI wire / rope 10 mm diameter

50

6756

135.13

... More
Copper cable as per specifications - 95q.mm

70

124513

1778.76

... More
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge.

-

-

-

... More
25 mm

30

12193

406.46

... More
37 mm

30

17039

567.99

... More
50 mm

40

35029

875.73

... More
100 mm

40

62725

1568.13

... More
Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge.

1000

129150

129.15

... More
"FLAME PROOF FITTINGS : Note: All equipment under this category shall be suitable for location in zone-I gas group IIA & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure. "

-

-

-

... More
"FLP/WP PUSH BUTTON STATION : Supply ,erection,testing and commissioning of FLP/WP push button(ON/OFF) control station of approved make with /without ammeter for the motor off control at field including connection and termination of copper control cable, fabricating, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per the specification and directions of the Site Engineer/Engineer-in-charge."

-

-

-

... More
Without Ammeter

1

6145

6145.48

... More
"FLP & WP JUNCTION BOX Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable termination of motor, including connection and termination of earthing wire and conduits etc., including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect."

-

-

-

... More
8 way junction box with 8 cable entries (1 x 1" & 7 x 3/4") at bottom & 20 nos. terminals.

1

11066

11066.41

... More
6 way junction box with 6 cable entries (6 x 3/4") at bottom & 20 nos. terminals.

1

11037

11037.06

... More
4 way junction box with 4 cable entries (4 x 3/4") at bottom & 20 nos. terminals.

1

7394

7394.68

... More
FLP/WP EXHAUST FANS : Flame proof, weather proof, single phase, 12" exhaust fan, IP65, LM6 type EF1001 of FCG or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects

2

24587

12293.82

... More
FLP/WP ROTARY SWITCH : Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects

2

10118

5059.03

... More
FLP/WP DISTRIBUTION BOARDS : Supply, erection, installation, testing and commissioning of flameproof /weather proof (IP-65) distribution board as per technical specification of types mentioned for lighting purpose in MLPU / booster shed etc., including connection and termination of power cables, earthing wire and conduits etc. including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entriescomplete as per drawings, spe cifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

-

-

-

... More
Outdoor Type, floor mounted, flameproof, weatherproof (IP 65) Lighting Distribution board Type-I DB with Bus bar - 100 A TPN, Incomer - 1 no. 63 A TPN MCB & Outgoing - 9 no. 10 A SPN, MCB

1

78735

78735.78

... More
FLP/WP SWITCH CUM SOCKET : Supply, erection, installation, testing and commissioning of flameproof /weatherproof switch cum socket /welding receptacle of approved makes to be installed on walls, coloumns, structures, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., including connection and termination of earthing wire and conduits., etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

-

-

-

... More
250 V , 15 A switch cum socket with plug

1

2567

2567.52

... More
250V, 63 A Plug & welding receptacle

1

19506

19506.84

... More
415V, 63A, Switch & Socket with Plug (No. of Pins 3P +N+ E), Model EPSS 1563-61 of Baliga or Equivalent approved make

1

16158

16158.59

... More
WP 6 WAY JUNCTION BOX : Supply, erection, installation, testing and commissioning of weather proof 6 way junction box of approved make for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect.

1

5136

5136.98

... More
"SHOCK TREATMENT CHART : Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language)."

2

3905

1952.84

... More
"CAUTION BOARD : Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language."

2

3944

1972.27

... More
"STAINLESS STEEL INSCRIPTION PLATE : Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc."

2

1808

904.4

... More
"PLASTIC INSCRIPTION PLATE : Supply and installation of approved quality plastic name inscription plates including engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc."

2

1470

735.23

... More
"Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor."

-

-

-

... More
1 light point controlled by 1 switch.

10

11734

1173.44

... More
2 light points controlled by 1 switch

8

11310

1413.81

... More
3 light points controlled by 1 switch

6

10814

1802.44

... More
4 light points controlled by 1 switch

4

8614

2153.57

... More
Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular switch) including providing space for electronic regulator in switch box , providing and fixing fan hook in the ceiling as per specifications and drawings.

8

14695

1836.88

... More
"Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade including earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan including providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit. "

10

18898

1889.82

... More
Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specifications and drawings

5

14345

2869.1

... More
"Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st plug point for multiple exhaust fans in one circuit. "

5

10437

2087.57

... More
"Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box "

2

6340

3170.15

... More
"Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 3 numbers, 6 A 5 pin modular sockets and 10 A modular switches for UPS point as per specifications and drawings "

2

4094

2047.24

... More
"Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings "

-

-

-

... More
"Type III Distribution Board : Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification "

1

84101

84101.55

... More
Type IV DIstribution Board : Double Door Translucent Euro DB of Havells or approved make as per appendix -1, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification

2

152431

76215.9

... More
Type V Distribution Board : Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification

1

64587

64587.18

... More
Critical Light DB : Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB

1

8992

8992.53

... More
Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bottom of light fitting shall be 2 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof and Weatherproof 2x26W CFL well glass light fitting complete with lamp and builtin control gear and choke of approved make(Cat.No.WG/A/1234 of Sudhir Switchgears or equivalent approved make), including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe(radius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box(with 4 cable entries) having 8 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings and instructions of EIC / Site engineer.

5

121001

24200.28

... More
"Ceiling fan with electronic regulator & other accessories and fittings etc. of or approved make as per appendix -1 with the following sweep size:- 56"" Sweep"

8

23850

2981.26

... More
12" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect.

1

7768

7768.48

... More
"Exhaust fan Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greaves or of approved make as per appendix -1 fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications, drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete."

-

-

-

... More
18" Sweep

3

26508

8836.28

... More
12" Sweep

1

5452

5452.21

... More
"PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc."

-

-

-

... More
19 mm

100

9748

97.48

... More
25 mm

100

13782

137.82

... More
32 mm

100

16181

161.81

... More
Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S.458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jointing of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer.

-

-

-

... More
300 mm dia

10

24074

2407.42

... More
200 mm dia

10

12736

1273.6

... More
"Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid . "

2

8646

4323.21

... More
Installation, laying of 2 Pair PVC insulated copper conductor un-armoured telephone cables in 16 mm/ 25 mm/ 32 mm PVC conduits from IDF through ceiling/ wall/trench and post-laying end to end testing of telephone cables. The job includes supply, installation, fixing of wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O with modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and d irections of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

100

13152

131.52

... More
Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from network switch through ceiling/wall/trench and post-laying end to end testing of cables. The job includes installation & fixing of Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

100

9242

92.42

... More
Supply , fixing  and erection of Modular cable transit (MCT) for cable Entry to Building in proper frame including supply of  Peelable type, spare block, stay plates, compression wedgs etc. with all accessories as per specification, considering 20 % minimum spare in each module, to be installed as per the instruction of Engineer in Charge/site engineer. GALVANISED MILD STEEL frame- with Packing Space of min. 120 x240 mm with multi diameter Blocks and accessories with peeling off arrangement to adjust cable size from 3.5 MM to 99 MM outer dia .

1

26110

26110.66

... More
Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation shall be provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work and shall be taken up separately.

-

-

-

... More
For 30 M Height High Mast Tower

2

350765

175382.53

... More
"FLAME PROOF LIGHT FITTINGS : Supply erection , installation , testing and commissioning of flame proof light fittings of approved make alongwith flame- proof control gear box containing ballast & condensor and lamp, including fixing on walls,columns, structures, poles etc. as required ,grouting clamping , supporting including fabrication and installation of clamps, nuts, bolts ,earthing with 8 SWG GI wire , connecting the lamps, cable terminals at the light fittings, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc.complete as per drawings, specifications and directions of Site Engineer / Engineer-in-Charge including the cost of all labour ,tools, materials etc. complete in every respect."

-

-

-

... More
"FLAMEPROOF LED FITTING 125W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:- IIA/IIB, IP 65, T6. Complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with provision of Cable Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), Mounting Arrangement: with M.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye Bolt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5."

4

100122

25030.57

... More
"FLAMEPROOF LED FITTING 60W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:- IIA/IIB, IP 65, T6. complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with a provision of Cable Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), Mounting Arrangement: with M.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye Bolt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5. Without External reflector"

2

25030

12515.29

... More
Flameproof LED Tubelight fitting, fixture complete with Philips Essential LED Tube 1200MM 18W865 T8 Model complete.

4

58404

14601.17

... More
FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007

4

35200

8800

... More
FLAMEPROOF EXHAUST FAN,12", SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007

2

17444

8722

... More
"Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications."

-

-

-

... More
LED Light fitting type RC380B LED32S-6500 L120W30 PSU OD of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc suitable for installation in false ceiling

4

25030

6257.64

... More
WP Endura LED: Supply and fixing of surface mounted weather proof Endura LED WT 550 light fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation

4

35460

8865

... More
LED Light fitting suspended type Sereno SP824 P LED 30S-5000 GR OA of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

4

33374

8343.52

... More
LED Light fitting type TMC 501 P 2xT-LED 22W P3242 of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

16

33374

2085.88

... More
LED Light fitting Cirrus Mini pro SM200C LED16S 6500 PSU OD WH of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

2

10429

5214.7

... More
LED Light fitting GreenLED down light DN092B LED10S-6500 PSU WH of PHILLIPS or approved equivalent make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc.

2

5214

2607.35

... More
Installation, testing, commissioning charges of SPV based LED street light including supply of 5 m high GI pole (with suitable panel mounting arrangement) and associated civil foundation works complete in all respects

40

164534

4113.36

... More
VI ELECTRICAL PCP COMPOS MAINLINE

-

-

-

... More
Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings.

-

-

-

... More
Zinc Anode

2

15051

7525.85

... More
"Supply & installation of Anode bed ( deep well type with MMO anodes) as per the approved configuration for Impressed Current Cathodic Protection system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe, casing pipe , centralizers, vent pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection and providing foundation of Anode Junction Box as per specifications inlcuding supply, excavation, backfill of earth etc. as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour & material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
Mainline CP & Station CP : Anode bed deep well type

1

540159

540159.5

... More
"Supply & installation of Anode bed ( shallow type ) as per the approved configuration for 'Impressed Current Cathodic Protection' system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection, providing foundations of Anode Junction Box, chain link fencing around anode junction box wherever required, as per specifications including supply of back fill material, excavation, backfill of earth and filling the sand with requisite back fill material as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour and material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
Mainline CP : Anode bed shallow type

1

314640

314640.1

... More
"Cable Marker Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all materials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge."

-

-

-

... More
Cable marker

3

2785

928.65

... More
Supply & installation of GSM based digital data logger of approved make for remote monitoring of PSP, alongwith supply and installation of permanent reference cell of approved make with tail cable (10 m), including making all connections, all labour and materials as per specification and approved design.

-

-

-

... More
Data logger

1

158428

158428.64

... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

-

-

-

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for PSP Measurment)

4

71594

17898.62

... More
Type DAC (With Ingress Protection IP:55)

1

28467

28467.68

... More
Flameproof Type E (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment.

10

408167

40816.71

... More
Flameproof Type DMV (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment.

1

35822

35822.07

... More
"The job at each TLP of type DMV at stations for protection of Valve locations shall include Supply, installation, testing and commissioning of the following: A. TLP of type DMV shall be flameproof Ex#d casted from Aluminium alloy LM6 duly approved by PESO and weatherproof as per certified and approved drawing for flameproof junction box having all connection facilities as per latest revision of drawing 9200-99900-404-601-02 (STD-481) and 9200-99900-404-603-00 : (STD-483), Heavy Gauge MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal stud bolts, neoprene gasket for front door, vandal proof concealed lock, The work includes excavation and providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. Flameproof & weatherproof DMV type TLP shall house solid state diode decoupling device and Zinc anodes shall be used for grounding as detailed below. B. Zinc anodes (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. Number of zinc anodes shall be such that earth resistance value of up to 5 Ohm is obtained. C. Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Connection scheme for the above mentioned item shall be as per latest revision of standard drawing no.: 9200-99900-404-601-02 (STD-481). Flameproof certificate from PESO shall be submitted for the flameproof & weather proof TLP for the item."

-

-

-

... More
Flameproof Type DMV with inbuilt provision of Voltmeter & pushbutton for PSP Measurment (With Ingress Protection IP:55)

1

109054

109054.04

... More
"The job at each TLP of type DAC for protection from AC interference or for protection at Valve locations shall include supply, installation, testing and commissioning of the following; A. TLP type DAC fabricated of MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Gauge MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal stud bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of 9200-99900-404-601-02 (STD-481) and Standard AFC drawing 9200-99900-404-603-00 : (STD-483). The work includes excavation and providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal stud bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to pipe coating (with coating repair etc.), backfilling the cable trenches, clearing and cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cable required for the job (as per site conditions) and including lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the front side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. DAC/DMV type TLP shall house solid state decoupling device and Zinc anodes shall be used for grounding as detailed below. B. Zinc anodes (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter for each anode including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. Number of zinc anodes shall be such that earth resistance value of up to 5 Ohm is obtained. Zinc anodes shall be connected to the TLP through weather proof junction box/ boxes. C. Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations of voltage level 66 KV or above including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, etc. The job shall be complete in all respects including all required materials, tools, consumables, labour as per work specifications, engineering document & direction of the Site Engineer/Engineer-In-Charge. Connection scheme for the above mentioned item shall be as per latest revision of standard drawing no.: 9200-99900-404-601-02 (STD-481)."

-

-

-

... More
Type DAC (With Ingress Protection IP:55)

1

107551

107551.87

... More
VII ELECTRICAL TCP COMPOS MAINLINE

-

-

-

... More
Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable of size of 1c x 6 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings.

-

-

-

... More
Magnesium Anode

6

37670

6278.38

... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

-

-

-

... More
Type A (With Ingress Protection IP:55)

1

14562

14562.51

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for PSP Measurment)

1

17898

17898.62

... More
Type B (With Ingress Protection IP:55)

1

35000

35000.95

... More
Type C (With Ingress Protection IP:55)

1

22894

22894.15

... More
Type D (With Ingress Protection IP:55)

2

35521

17760.8

... More
Preparation & installation of corrosion coupon from owner supplied coated pipe. which involves preparation of sample of size 2"x4", application of pipeline coating material on the coupon, soldering 6 sq. mm. cable with coupon, sealing the soldered joint with epoxy, positioning the coupon at the pipe line depth and with in a distance of 0.5 M from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement for preparation of the coupon. The work complete in all respect shall include supply of all labour, tools etc complete as per the directions of the Site Engineer and as per drawing no. 9200-99900-404-601-01 & 9200-99900-404-607-01.

-

-

-

... More
Corrosion Coupons

2

3530

1765

... More
IP 101 IP 102 Service ITC PUDUCHERY

-

-

-

... More
I MECHANICAL WORK SERVICE CSW

-

-

-

... More
"Above Ground Equipments Installation: Taking delivery of equipments from designated stores/stockyard, shifting / transporting to station premises, placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water/ nitrogen as applicable, draining, checking, testing with Nitrogen, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instructions, specifications and instructions of Site Engineer / EIC."

-

-

-

... More
SCRAPER BARREL

-

-

-

... More
6"X10" x 600# Bi-Directional Scrapper Barrel

1

48862

48862.8

... More
INSULATING COUPLING

-

-

-

... More
6" x 600# Insulating Coupling

4

28148

7037.1

... More
4" x 600# Insulating Coupling

2

9382

4691.4

... More
FILTRATION SKID

-

-

-

... More
Filtration Skid

12

379961

31663.45

... More
METERING SKID

-

-

-

... More
Custody transfer Metering skid for Customer connectivity

3

94990

31663.45

... More
PRS SKID

-

-

-

... More
PRS skid

15

474951

31663.45

... More
FLOW TEE

-

-

-

... More
6" x 600# Flow tee (Equal)

2

14074

7037.1

... More
6" x 4" x 600# Flow Tee (Unequal)

2

14074

7037.1

... More
"Above ground piping: Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises/stockyard/store, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and intsalling pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC."

-

-

-

... More
FOR PROCESS PIPING

-

-

-

... More
6.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X 52

105

300589

2862.76

... More
4.5" OD x 0.337" ASTM A333 GR.6

55

114437

2080.68

... More
2.375" OD x 0.344" ASTM A333 GR.6

70

64933

927.62

... More
1.315" OD x 0.25" ASTM A333 GR.6

30

19177

639.24

... More
1.050" OD x 0.219" ASTM A333 GR.6

50

21300

426

... More
"Under ground piping:(Process Piping) Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises/stockyard/stores transporting the same to site, fabrication and erection of underground piping including cutting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., underground at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc., cleaning the material surface by sandblast cleaning, coating and wrapping the pipes/pipe fittings with coaltar base tape coating material (including the supply of coating tape, precoat material etc.), holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of the Site Engineer / EIC"

-

-

-

... More
6.625" OD x 0.432" ASTM A333 GR.6 /0.312" API 5L X 52

20

50325

2516.25

... More
4.5" OD x 0.337" ASTM A333 GR.6

30

55276

1842.56

... More
2.375" OD x 0.344" ASTM A333 GR.6

50

56534

1130.68

... More
1.315" OD x 0.25" ASTM A333 GR.6

30

30456

1015.2

... More
1.050" OD x 0.219" ASTM A333 GR.6

30

20817

693.92

... More
Installation of Valves

-

-

-

... More
API 6D BALL VALVE -GAS OVER OIL ACTUATED

-

-

-

... More
6"x ANSI 600# fully welded W/W, A/G, API 6D ball Valve -Gas over oil Actuated

3

35395

11798.48

... More
API 6D BALL VALVE -Lever / Gear Operated

-

-

-

... More
6"x ANSI 600#, Bolted F/F, A/G, Gear operated

3

28316

9438.78

... More
4"x ANSI 600#, Bolted F/F, A/G, Gear operated

9

56632

6292.52

... More
2"x ANSI 600#, Bolted F/F, A/G, Gear operated

27

56188

2081.04

... More
4"x ANSI 600#, fully welded, W/W, A/G, Gear operated

3

18877

6292.52

... More
2"x ANSI 600# fully welded,w/w, A/G, lever operated

12

24972

2081.04

... More
4"x ANSI 600# fully welded,w/w, U/G, Gear operated-Extended stem

2

12585

6292.52

... More
BS 5351/ISO 17292 BALL VALVE/ BS 1873 Globe Valve

-

-

-

... More
1"x ANSI 800# HOV W/W BS 5351 BALL VALVE

4

3136

784.19

... More
3/4"x ANSI 800# HOV W/W BS 5351 BALL VALVE

39

22937

588.14

... More
4"x ANSI 600# F/F BS 1873 GLOBE VALVE

4

22978

5744.54

... More
2"x ANSI 600# F/F BS 1873 GLOBE VALVE

9

18626

2069.6

... More
1" X 2" x ANSI 600# x150# F/F PSV

1

2930

2930.13

... More
Radiographic Inspection: Inspection of welding by radiographic method on all types of piping including processing of films and interpreting the results of weld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the welds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all pesonnel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i) Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii) Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii) For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor's cost. In case where radiography is not possible: v) Verification by utrasonic testing shall be done at contractors cost. vi) Magenetic particle inspection as and where required shall be done at Contractors cost. vii) Digitization of all films to be carried out.

-

-

-

... More
6" NB Pipe Joints

80

84698

1058.73

... More
4" NB Pipe Joints

80

80183

1002.29

... More
2" NB Pipe Joints

170

96216

565.98

... More
1" NB Pipe Joints

50

20804

416.09

... More
3/4" NB Pipe Joints

120

46872

390.6

... More
Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- FOR SV STATIONS

1

7500

7500

... More
Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- FOR RT STATIONS/TERMINALS

3

37500

12500

... More
Providing services assistance during pre-commissioning and commissioning of entire SV station piping with or without tap-off/with or without scraper barrel including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge

1

12500

12500

... More
Providing services assistance during pre-commissioning and commissioning of scraper barrel, Knock out drums, filters, metering skid, pressure reduction skids as applicable for entire Receipt station piping including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge

3

75000

25000

... More
II INST SERVIC CSW

-

-

-

... More
INSTALLATION OF PRESSURE INDICATOR: Installation, testing and commissioning of Pressure Indicator (PI) of various ratings with/ without gauge saver as per directions of Engineer in-charge/ Site engineer and Drawings.

3

10834

3611.64

... More
III OFC AND TELECOMM SUPPLY CSW ML

-

-

-

... More
Laying of HDPE pipe(excluding blowing of OFC) in mainline pipe trench/ independent trench at the bottom in all types of soil (including roads, canals, rivers, nullahs, water course crossings, submerged crossings, saltpan areas etc.) including supply and installation of suitable straps for strapping the HDPE duct with mainline pipe for anti buoyancy, installation of HDPE duct accessories such as plastic couplers, end caps, end plugs, cable sealing plugs, supply and installation of warning tape, consumable guide rods, HDPE jointing, inspection of HDPE joints, testing the installed HDPE duct by blowing "mandrel" with compressed air, pressure testing the HDPE pipe after laying as per procedure and performing all work as per drawings, specifications and instruction of the Engineer-in-charge/ Site Engineer and provisions of the contract document for making the duct ready in all respect for OFC blowing. The job includes transportation, loading and unloading of HDPE ducts in nominal length of 1000 meters and duct accessories such as couplers, end caps, end sealing plugs etc. to various sites along the entire ROW / HDD crossing locations as per specifications and directions of Engineer-in-charge/ Site Engineer

5

82145

16429

... More
Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (ROW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer.

5

135265

27053

... More
Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/ Site Engineer

2

17852

8926

... More
Installation of RF iD type Electronic Markers as per tender specifications. The job includes configuration & programming of the Electronic markers to write information data as per directions of Engineer-in-charge/ Site Engineer.

2

1336

668

... More
Installation of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer

5

5535

1107

... More
Installation of OFC Joint pit markers at every joint location as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer

2

2072

1036

... More
Installation of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer.

2

5064

2532

... More
IV OFC AND TELECOMM SERVICE MAINLINE

-

-

-

... More
V ELECTRICAL SERVICE CSW

-

-

-

... More
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

370

222270

600.73

... More
WBM ROAD / CONCRETE BREAKING : WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

15

57952

3863.53

... More
"Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge"

-

-

-

... More
Power cables LT : OD upto 20 mm

530

16424

30.99

... More
Power cables LT : OD above 20 mm and upto 40 mm

1200

54060

45.05

... More
Power cables LT : OD above 40 mm and upto 60 mm

400

29164

72.91

... More
Power Control cables LT : OD upto 20 mm

400

17784

44.46

... More
Control cables (T&I) : OD upto 20 mm

750

52335

69.78

... More
Control cables (T&I) : OD above 20 mm and upto 30 mm

20

1591

79.56

... More
Control cables (T&I) : OD above 30 mm and upto 40 mm

50

4712

94.24

... More
"Erection, Installation, Connecting, testing and commissioning of 25/20/15 KVA three/single phase 415V/240V Silent Emergency DG with PLC based AMF panel, batteries and acoustic enclosure, including execution of terminal connections of power and control cables for DG set & AMF Panel & other accessories of DG Set earthing of alternator neutral, frame and armour of the cable etc., as per drawings, specifications, recommendations of the D.G. Set manufacturer and directions of the Site Engineer. The job complete in all respects including supply and installation of all the required power and control cable upto AMF Panel, cable end lugs, cable glands,GI/Copper earthing wire/strip, acoustic enclosure etc.including all labour, tools, consumable etc. Cost is inclusive of Supervision & Assistance in installation & commissioning of above DG set(s) at site by DG supplier. It may be noted that all works related to foundation is included in the contractor's scope of work. ( The POL for the DG set commissioning & trial run shall be arranged by the owner, free of cost) Note : Main LT power cable from DG set to ACDB panel shall be provided by the Owner."

-

-

-

... More
25/20/15 KVA DG Set

1

42264

42264.33

... More
Installation of corrosion monitoring probes including 2" Flareweld on station piping at desired location and 12 O'Clock position for mounting of ER Probe under the supervision of ER probe supplier and site engineer. Flareweld assembly shall be supplied by contractor as per item mnetioned in supply part. The job complete in all respect with material, tools & tackles, consumables etc. Cost is inclusive of Supervision & Assistance in installation & commissioning of ER probe at site by ER probe supplier.

1

15431

15431.89

... More
Installation, testing and commissioning of Free Standing Floor mounted ACDB Panel as per the specifications including terminations, connections, supply of end lugs, cable glands, making spare entries blind, providing tags & ferrules, pasting panel wiring diagram with acrylic sheet inside the panel, all other materials, labour tools and tackles as per the directions of the Site Engineer / Engineer-in-charge.Cost is inclusive of Supervision & Assistance in installation & commissioning of ACDB panels at site by panel supplier.

-

-

-

... More
ACDB Panel

1

24809

24809.87

... More
Erection, Installation,Testing & Commissioning of the high mast tower with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour. Scope of work shall include erection & installation of high mast tower, cable connections, erection & installation of luminaries & aviation lights, lightning finial, all accessories, cables, etc., erection, foundation casting & grouting of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to base compartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mast tower including construction of earth pits to be operated in relevant separate item. Cost is inclusive of Supervision & Assistance in installation & commissioning of high mast at site by HMT supplier.

-

-

-

... More
For 30 M Height High Mast Tower

2

135303

67651.83

... More
VI ELECTRICAL PCP SERVIC MAINLINE

-

-

-

... More
Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.

-

-

-

... More
Solid State Decoupling Device

21

133251

6345.33

... More
Installation of grounding cells including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of grounding cell etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Gounding Cell

10

48446

4844.69

... More
Installation of surge arrestors including terminating the cables, laying of cable, testing & commissioning of surge arrestors etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Surge Arrestor/ Surge Diverter

10

63173

6317.34

... More
Installation of permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cable, testing & commissioning of cell etc. all complete with required material, excavation, backfilling etc. as per specifications, recommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Permanent half cell

3

22182

7394.23

... More
Conducting " Coating-Resistance Survey" for calculation of effective coating resistance of the pipeline in ohms-sq.m. along the entire pipeline and plotting on SEMILOG or X-Y GRAPH & submitting the report in graphical form as well as soft copy as per Specification / approved procedure and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Coating Resistance Survey

2

3093

1546.91

... More
Conducting Close Interval ON/OFF Potential Logging Survey at an interval of 1 m over the buried line in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Close Interval ON/OFF Potential logging survey

2

7636

3818.23

... More
"Conducting Direct Current Voltage Gradient Survey over the buried line to identify / pin point the coating defects in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects as per directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contractor, who will arrange to repair the defects."

-

-

-

... More
Direct Current Voltage Gradient Survey

2

8878

4439.34

... More
Conducting "Soil Resistivity Survey" at anode bed location after ascertaining its suitablity with respect to the existing system , for installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Soil Resitivity Survey

1

30992

30992.78

... More
"Conducting AC interference survey, to detect presence of any AC voltage induced on pipeline as per approved procedure. The work shall be completed in all respects including survey recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at all TLPs by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations."

-

-

-

... More
AC interference survey

2

23270

11635.11

... More
Conducting Mututal Interference Survey among the new and existing pipelines / facilities(foreign) by taking PSP survey of all the pipelines as per approved procedure to determine level of interference at different places along the pipeline and at point of crossing in common ROW including identifying points and providing the data/ record in graphical form and carrying out all necessary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remedial measures undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphs in six sets.The item should be complete in all respect including survey, work for mitigating the interference and post mitigating survey as per specifications/directions of site engineer / Engineer-in-Charge.

-

-

-

... More
Mutual Interference Survey

2

14527

7263.63

... More
"Cathodic Protection Units Erection, testing and commissioning of cathodic protection units (CPTR/CPPSM); including supply and installation of all facilities, materials etc., including fuses, all supporting structures, laying and connecting the 1100 V Grade power cable (2 runs of 1Cx25 sqmm Cu. conductor XLPE insulated Armoured Cable) from DCDB to CPPSM unit / laying and connecting the 1100 V Grade power cable (owner provided 1 run of 3Cx10 sqmm Al. conductor XLPE insulated Armoured Cable) from ACDB to CPTR unit, providing the earthing arrangement. The work includes furnishing the test results by conducting all the NO LOAD and ON LOAD tests on the CP units and adjusting settings as required and testing the pipeline section for full cathodic protection for entire stretch. The job complete in all respect shall include cost of all labour, tools as per specifications and directions of the Site Engineer / Engineer-in-Charge. "

-

-

-

... More
230V AC cum (-) 48V DC Operated automatic type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V, 25 A DC with with DC-DC converter & SCADA linkage facility as per specifications

1

42698

42698.64

... More
Installation, testing and commissioning of 48 V, 400 AH Battery bank system with rack, battery charger etc., as per specifications including interconnection with other equipments etc., all complete with materials like cables, lugs, sealing materials and other materials deemed necessary. Item includes supply, laying, connection and termination of all copper conductor XLPE cables from ACDB to Battery Charger

-

-

-

... More
Battery Bank System

1

91251

91251.59

... More
Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and all other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank

-

-

-

... More
DC distribution board

1

3512

3512.66

... More
Laying of anode header / cathode / reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / half cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleeve, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, backfilling etc.,; in all types of strata and soil (including rock) by making the trench, back filling the trench, cable terminations, work complete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engineer-In-Charge and approved drawings.

-

-

-

... More
1cx35 sq. mm

500

95025

190.05

... More
1cx25 sq. mm

250

35262

141.05

... More
2cx6 sq. mm

750

112230

149.64

... More
Measuring, recording and submitting the cathodic protection readings along the entire pipeline by repeated adjustments of the settings of the CPTR/CPPSM units etc as per specifications for achieving full/maximum protection of all the stretches as per the criteria of protection mentioned in the specifications. Measuring the relevant readings at the cathodic protection stations and "pipe to soil potential" readings at all the test lead locations along the pipeline including the CP station parameters like current(AC/DC), voltage(AC/DC),circuit resistance ,battery voltage/current etc.,preparing and submitting pipe to soil potential profile, graphs and other data pertaining to the cathodic protection of the pipeline,job complete in all respects as per specification and instructions of Site Engineer / Engineer-in-Charge, including cost of all labour, instruments and services rendered.

-

-

-

... More
CP Readings

2

911

455.79

... More
"Final Commisioning of CP system Final Commissioning of the impressed current cathodic protection system for the mainline for achieving full protection as per protection criteria as mentioned in the specifictions through repeated adjustments of the CP units after installation of galvanic anodes for hot spot protection and mitigation of AC/ DC interference, if any and submission of the resultant data to the owner and testing, measuring, recording and submitting all these data once again after the lapse of a period as per specifications / directions of the Site engineer / Engineer-in-Charge, including the cost of all labour tools and materials as required, complete in all respect."

-

-

-

... More
Commissioning

1

1520

1520.45

... More
VII ELECTRICAL TCP SERVIC MAINLINE

-

-

-

... More
Pipe to Soil potential Readings : Measurement, recording and submission of Pipe to Soil Potential readings by connecting / disconnecting the Mg anodes (for achieving optimal protection through TLPs) along the entire pipeline and at stations, including preparing and submiting relative PSP profile and other relevant data pertaining to the cathodic protection of the pipeline, including cost of all labour, instruments and services rendered. The readings shall be furnished as per the specifications and as per the directions of the Site Engineer/Engineer-in-Charge.

-

-

-

... More
PSP Readings

1

2820

2820.07

... More
TCP System Engineering Document : Prepare & Submit Engineering Document including detail engineering & drawings for TCP system and other documentations as mentioned in the specification and as per direction of Site Engineer / Engineer-in-Charge. The work includes submission of final document afterapproval in requisite sets.

-

-

-

... More
Engineering Document/ Technical report

1

1635

1635.64

... More
Conducting Pearson Survey over the buried line in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one reproducible containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects.

2

7476

3738.36

... More
IP 101 IP 102 Supply ITC PUDUCHERY

-

-

-

... More
I MECHANICAL WORK SUPPLY CSW

-

-

-

... More
Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
150#

-

-

-

... More
4" SWMG ANSI 150#

4

714

178.68

... More
1" SWMG ANSI 150#

5

268

53.77

... More
600#

-

-

-

... More
6" SWMG ANSI 600#

20

15710

785.54

... More
4" SWMG ANSI 600#

18

11598

644.37

... More
2" SWMG ANSI 600#

38

7119

187.35

... More
3/4" SWMG ANSI 600#

38

3112

81.9

... More
Supply and delivery of Insulating Gaskets at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
2" SWMG ANSI 600#

2

16000

8000

... More
Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
150#

-

-

-

... More
Fasteners for Flanges 4" x 150# (0.625" Dia. X 4.00" Length)

32

1965

61.43

... More
Fasteners for Flanges 1" x 150# (0.500" Dia. X 3.00" Length)

20

786

39.32

... More
600#

-

-

-

... More
Fasteners for Flanges 6" x 600# (1.0" Dia. X 9.0" Length) - extended stud length for flanges with spectacle blind

60

16335

272.26

... More
Fasteners for Flanges 6" x 600# (1.0" Dia. X 7.5" Length)

180

39947

221.93

... More
Fasteners for Flanges 4" x 600# (0.875" Dia. X 7.75" Length) - extended stud length for flanges with spectacle blind

48

13760

286.67

... More
Fasteners for Flanges 4" x 600# (0.875" Dia. X 6.50" Length)

96

23134

240.98

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 5.75" Length) - extended stud length for flanges with spectacle blind

64

7240

113.14

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 4.75" Length)

240

21739

90.58

... More
Fasteners for Flanges 3/4" x 600# (0.625" Dia. X 4.0" Length)

152

14204

93.45

... More
Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
WNRF-150#

-

-

-

... More
4", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2

4

4442

1110.72

... More
1", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2

6

1659

276.56

... More
WNRF-600#

-

-

-

... More
6", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

30

235369

7845.66

... More
4", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

20

75052

3752.63

... More
2", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

50

45412

908.25

... More
3/4", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1

60

22164

369.4

... More
BLRF

-

-

-

... More
600#

-

-

-

... More
6", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

1

7123

7123.68

... More
2", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

11

8757

796.11

... More
1", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2

6

2630

438.42

... More
SPECTACLE BLINDS:Supply and delivery of following mentioned Spectacle Blinds at respective stations as per Station wise Break up of material supply and as per technical specifications indicated in tender docuemnts.

-

-

-

... More
600#

-

-

-

... More
6" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

3

64452

21484.05

... More
4" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

4

55237

13809.49

... More
2" Spectacle Blind 600# F/F R/F - ASTM A350 LF2

3

25174

8391.5

... More
Supply and delivery of API 6D Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
API 6D BALL VALVE

-

-

-

... More
2" W/W ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCB

1

22047

22047.87

... More
2" F/F ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCB

1

21768

21768.21

... More
BS 5351 Ball valve

-

-

-

... More
1" W/W ANSI 800# A/G, BALL VALVE- BS 5351-ASTM A350 LF2/ASTM A352 LCB

2

21693

10846.93

... More
3/4" W/W ANSI 800# A/G, BALL VALVE-ASTM A350 LF2/ ASTM A352 LCB

30

244056

8135.2

... More
BS-1873 Globe valve

-

-

-

... More
600#

-

-

-

... More
4",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

2

106342

53171.36

... More
2",600#,F/F, A/G-ASTM A350 LF2/ASTM A352 LCB

3

63587

21195.79

... More
PSV

-

-

-

... More
1"x2"x600# x150# PSV -ASTM A350 LF2/ASTM

1

30000

30000

... More
Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
Un Equal Tee

-

-

-

... More
600#

-

-

-

... More
6"x4" x 600# (Sch 80x 80) Unequal Tee-ASTM A420 Gr.WPL6

1

4695

4695.6

... More
4"x2" 600# (Sch 80x 160) Unequal Tee-ASTM A420 Gr.WPL6

1

1276

1276.31

... More
3"x2" 600# (Sch 80x 160) Unequal Tee-ASTM A420 Gr.WPL6

1

1026

1026.16

... More
2"x3/4" 600# (Sch 160x 160) Unequal Tee-ASTM A420 Gr.WPL6

22

10926

496.66

... More
Equal Tee

-

-

-

... More
600#

-

-

-

... More
4" 600# Equal Tee (Sch 80 x 80)-ASTM A420 Gr.WPL6

1

1322

1322.4

... More
2" 600# Equal Tee (Sch 160 x 160)-ASTM A420 Gr.WPL6

7

2809

401.34

... More
1" 600# Equal Tee(Sch 160 x 160)-ASTM A420 Gr.WPL6

1

373

373.12

... More
3/4" 600# Equal Tee(Sch 160 x 160)-ASTM A420 Gr.WPL6

1

279

279.84

... More
Elbow-90 deg LR Bends

-

-

-

... More
600#

-

-

-

... More
6" 600# 90 deg LR Bend (Sch 80 )-ASTM A420 Gr.WPL6

15

36122

2408.16

... More
4" 600# 90 deg LR Bend (Sch 80 )-ASTM A420 Gr.WPL6

10

15701

1570.15

... More
2" 600# 90 deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

20

8953

447.67

... More
1" 600# 90 deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

3

799

266.4

... More
3/4" 600# 90 deg LR Bend (Sch 160)-ASTM A420 Gr.WPL6

6

1198

199.8

... More
Weld-o-let

-

-

-

... More
600#

-

-

-

... More
6"X2" 600# (Sch 80 x 160) W-o-L-ASTM A350 Gr.LF2, CL 1

15

42178

2811.9

... More
4"X2" 600# (Sch 80 x 160) W-o-L-ASTM A350 Gr.LF2, CL 1

2

3749

1874.6

... More
Supply of API 5L/ ASTM A333 Gr.6 pipes at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document.

-

-

-

... More
6.625" OD x Sch.80 ASTM A 333 Gr. 6 PIP

75

177422

2365.63

... More
4.50" OD x Sch.80 ASTM A 333 Gr. 6 PIPE

50

75858

1517.16

... More
2.375" OD x Sch.160 ASTM A 333 Gr. 6 PIP

50

29710

594.2

... More
1.315" OD x Sch.160 ASTM A 333 Gr. 6 PIP

15

5058

337.2

... More
1.050" OD x Sch.160 ASTM A 333 Gr. 6 PIP

20

5385

269.25

... More
FIRE FIGHTING EQUIPMENT: Supply and delivery of Fire Fighting Equipment at respective stations as per Station wise Break up of material supply and as per techhnical specifications indicated in tender documents.

-

-

-

... More
Pair of Rubber hand gloves for Electrical work bearing IS mark

4

4076

1019.21

... More
First Aid Box with Snake serum

4

6143

1535.84

... More
Safety Helmet

8

2374

296.86

... More
PCV suit

4

21334

5333.53

... More
Ear plug

8

1200

150

... More
Ear muff

8

3600

450

... More
Safety Torch

4

15292

3823.08

... More
Cotton hand gloves

60

9000

150

... More
Flame Arrestor:Supply and delivery of following mentioned Flame Arrestor at respective stations as per Station wise Break up of material supply and as per technical specifications indicated in tender docuemnts.

-

-

-

... More
4" Flame Arrester

1

167332

167332

... More
II INST SUPPLY CSW

-

-

-

... More
Pressure Indicators (PI) of the following ranges as per the technical specifications attached in the Tender.

-

-

-

... More
"Range: 0 to 1 kg/CM2."

1

3707

3707.56

... More
Range: 0 to 100 kg/cm2

4

16924

4231.23

... More
" Gauge Saver (0-1 Kg/Cm2) as per the technical specifications as per tender.

1

1800

1800

... More
"FLP/ WP Junction Box, Type D. Bottom entries: 1 No. 1# NPT (suitable for 12CX1.5sqmm) Left side entries: 3 nos. ½# NPT (suitable for 4CX1.5sqmm) Right side entries: 3 nos. ½# NPT (suitable for 4CX1.5 sqmm) "

3

9825

3275.17

... More
"FLP/ WP Emergency Shut Down Push Button Switch (with 2 nos. cable entry provision of 1/2"" NPT) with steel hammer chained with main unit.

1

1571

1571.84

... More
FLP/ WP cable Glands (Suitable Sizes)

-

-

-

... More
1 1/4" (5/4") Suitable for 40 C X 1.5 mm control & 8Tx1.5 Sqmm triad cable.

2

666

333.46

... More
1" Suitable for 12C X 1.5 mm control & 5Px 1.5 mm signal cables.

10

2165

216.51

... More
1/2" Suitable for 4C X1.5 mm control, 2Px 1.5 mm signa & 1Tx 1.5 Sqmm triad cable.

18

1633

90.76

... More
FLP/ WP Plugs (Suitable Sizes)

-

-

-

... More
1 1/4" FLP/ WP Plugs

2

125

62.96

... More
1" FLP/ WP Plugs

8

503

62.96

... More
1/2" FLP/ WP Plugs

15

464

30.97

... More
FLP/ WP Reducers (Suitable sizes)

-

-

-

... More
3/4" to 1/2" FLP/ WP Reducers

2

417

208.85

... More
1" to 1/2" FLP/ WP Reducers

3

516

172.2

... More
CHEQUERED PLATE Supply and placing in position 5 mm thick steel checkered plates over cable ducts, valves, pits etc including keeping provision of holes for lifting arrangement as per drawing complete in all respect inclusive of cost of all labour, material, carriage etc as per specification & the direction of the engineer in-charge/site engineer

5

22265

4453.19

... More
GI CONDUIT FOR BUILDING WIRING 19 mm ISI marked GI conduit along with all fittings & fixtures like Tees, bends, junction boxes, etc for wiring in buildings

50

18643

372.87

... More
Instruments SS Fittings & Tubings

-

-

-

... More
TUBE 1/2" OD (M)

27

35637

1319.89

... More
Bushing 3/4" Butt Welded x 1/2" FNPT

12

24478

2039.87

... More
Male Connector 1/2" MNPT x 1/2" OD Tube

30

29072

969.08

... More
Female Connector 1/2" FNPT x 1/2" OD Tube

3

4167

1389.09

... More
1/2" OD Tube End cap

5

3380

676.01

... More
Union Tee 3 x 1/2" OD Tube

4

27683

6920.83

... More
2 Way Valve Manifold 2 x 12.7 MM FNPT, Material : SS316 with blanking plug for each port.

8

81752

10219.06

... More
Nipple 1/2" MNPT x 1/2" MNPT, 150 mm long

4

4692

1173.24

... More
Scrapper Detector Switch (14" 600#), Type: Vane, Body Material: Stainless steel, End connection: Flanged, Switch action: DPDT, Voltage:24 VDC, Current: 1A complete as per tender specifications

1

64682

64682.89

... More
III OFC AND TELECOMM SUPPLY CSW ML

-

-

-

... More
Supply of OFC Jointing kits as per tender specifications in ROW.

2

13732

6866

... More
Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications

2

3516

1758

... More
Supply of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications

5

10535

2107

... More
Supply of Joint pit markers for OFC joint locations as per tender specifications

2

5556

2778

... More
Supply of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications

2

19850

9925

... More
IV OFC AND TELECOMM SUPPLY MAINLINE

-

-

-

... More
V ELECTRICAL SUPPLY CSW

-

-

-

... More
SAFETY EQUIPMENT Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge

-

-

-

... More
RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.

2

5695

2847.63

... More
"INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per specifications."

-

-

-

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)

10

21239

2123.96

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)

2

4851

2425.93

... More
Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest)

5

28933

5786.76

... More
Supply of fully charged CO2 fire extinguishers as per specifications (2 kg capacity as per IS: 2878 latest)

5

19872

3974.4

... More
Supply of fire buckets mounted on stand

5

14908

2981.62

... More
Copper Cables - 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvaznized armoured, PVC type ST-2 overall sheathed, Stranded

-

-

-

... More
3C x 2.5 mm² FRLSH

50

3056

61.13

... More
2C x 4 mm², FRLSH

300

19515

65.05

... More
4C x 4 mm² , FRLSH

80

8955

111.94

... More
3C x 6 mm² , FRLSH

50

6233

124.67

... More
2C x 10 mm² FRLSH

50

7059

141.19

... More
Aluminium Cables - 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvaznized armoured, PVC type ST-2 overall sheathed, Stranded

-

-

-

... More
4C x 16 mm² , FRLSH

400

29896

74.74

... More
3½C x 25 mm² FRLSH

400

39588

98.97

... More
3½C x 50 mm², FRLSH

400

54920

137.3

... More
3½C x 95 mm² , FRLSH

400

128944

322.36

... More
ACDB Panel

-

-

-

... More
ACDB Panel as per technical specifications IOCL-PL-ELEC-LVSB-22

1

252493

252493.53

... More
Silent Diesel Generating Set : Supply of Silent Type DG set alongwith processor based AMF panel, Industrial Lead-Acid Batteries for Starting of DG Set, Acoustic Enclosure, exhaust piping with its support structure,fuel tank, etc., as given in the technical specification IOCL-PLELEC-LVDG-14 complete in all respects

-

-

-

... More
25 KVA, 3-Phase, 415 V

1

460817

460817.04

... More
Supply of high mast tower as per technical specification enclosed IOCL-PL-ELEC-HMT-1.0. The job includes supply of (1) 30 M high mast structure with lantern carriage with raising/lowering mechanism by FLP motor, min. steel plates sheet thickness shall be 5 mm (2) LED flood light fixtures & lamps- 350 W (120 Lumens/W min. efficiency) - 12 nos. & LED Aviation obstruction lights - 02 nos. (3) Lightning arrestor-1200 mm length finial (4) FLP feeder pillar board with cables from feeder pillar to base compartment of high mast (5) Foundation bolts. The vendor will submit the foundation design based on soil strata (soil report shall be provided by IOCL) of locations. Further vendor shall provide supervision for testing & commissioning of high Mast

-

-

-

... More
High Mast Shaft with cables, FLP/WP motor, cables and accessories - For 30 M Height

2

908896

454448.1

... More
Foundation bolts with anchor plate & common template for high mast tower (30M Height)

2

32654

16327.2

... More
LED flood light type -350 W (12 nos.) & Aviation obstruction LED light - 02 nos.

2

726888

363444.07

... More
Outdoor stand mounted FLP/WP feeder pillar

2

236417

118208.62

... More
Electrical resistance based corrosion monitoring system consisting of following items:-

-

-

-

... More
Access fittings flareweld

1

17315

17315

... More
Hollow Plug assembly

1

12855

12855

... More
Heavy Duty Protective Cover

1

11175

11175

... More
Primary Packing for Hollow Plug Assy

1

500

500

... More
Probe extension adapter

1

18930

18930

... More
Retrievable flush ER probe

1

50335

50335

... More
Receiver with Safety Barrier, 3 digit LED display, suitable for interfacing with SCADA as per specification

1

286880

286880

... More
Transmitter (intrinsically safe) as per specification including 5m suitable cable for connection with ER probe.

1

236550

236550

... More
Supply of SPV based LED street light (panel, battery, LED) - Su-Kam Sunway LI5 (40W) GSM or equivalent (refer technical specifications) at site approved by EIC and complete in all respects

40

1124300

28107.51

... More
VI ELECTRICAL PCP SUPPLY MAINLINE

-

-

-

... More
"PERMANENT CATHODIC PROTECTION SYSTEM Supply of materials/equipments as given below complete in all respects, as per the specification as detailed in the tender document including transportation to site and storing :"

-

-

-

... More
Supply of Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of MOVs and at HT line crossing locations

-

-

-

... More
Solid State Decoupling Device

21

1620136

77149.38

... More
Supply of Zn Grounding cells ( with prepackaged backfill material) including required length of cable (minimum 10 m) of approved make & as per specification in accordance with dwg no. 9200-99900-404-611-00

-

-

-

... More
Grounding Cells

10

73895

7389.54

... More
Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings

-

-

-

... More
Surge Arrestor/ Surge Diverter

10

125957

12595.71

... More
Supply of Cathodic Protection unit of approved make, complete in all respects as given in the specification with all its accessories to ensure trouble free operation

-

-

-

... More
230V AC cum (-) 48V DC Operated automatic type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V, 25 A DC with with DC-DC converter & SCADA linkage facility as per specifications

1

363222

363222.19

... More
Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc.

-

-

-

... More
Junction Box having IP-55 degree of protection

2

37034

18517.25

... More
Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as given in technical specifications

-

-

-

... More
DC distribution board with one incomer, 100 A DP MCB & outgoing feeders 1x63A DP MCB & 2x32 A DP MCB

1

19304

19304.6

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make

-

-

-

... More
Copper Cable size 1cx35 sq. mm Armoured

500

161625

323.25

... More
Copper Cable size 1cx25 sq.mm Armoured

250

58242

232.97

... More
Copper Cable size 2cx6 sq.mm Armoured

750

114285

152.38

... More
Copper Cable size 2cx25 sq.mm Armoured

100

45342

453.42

... More
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make

5

40149

8029.9

... More
IP 101 IP 102 OFC TELE Non ITC PUDUCHERY

-

-

-

... More
I SUPPLY

-

-

-

... More
Supply of permanently-lubricated HDPE pipe of 40 mm OD (as per TEC GR) with minimum pressure rating of 6 Kg/cm2 and wall thickness of 3.5 mm, along with duct accessories such as couplers, end caps, end sealing plugs, warning tape etc. as per specifications.

5

271850

54370



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.