Hindu Religious Institutions And Charitable Endowments Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Hindu Religious Institutions And Charitable Endowments - HRICE Tender
Civil And Construction
Building Construction
Eprocure
Opening Date4 Jul 2024
Closing Date19 Jul 2024
Tender Amount₹ 99,71,000
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of Shopping Complex Building
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRCE_459953_1Bid Award Id
ViewTender No
02/2023-2024Tender Authority
Hindu Religious Institutions And Charitable Endowments ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Documents of special attention and instruction to tenderers, Tender form and conditions,Tender Notice,Schedule A,Extract of Amendment,special conditions,Schedule B,Schedule C with General conditions of contract
BOQ Items
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification and as directed by the departmental officers.
29
-
-
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
a)For foundation and basement
65
-
-
b)For Super Structure(Ground floor)
49
-
-
c)For Super Structure(First floor)
43
-
-
d) For Super Structure(Second floor)
4
-
-
Brick work using Country Bricks Kiln burnt of size 8-3/4" x 4-1/4" X2-3/4"" in Cement Mortar1:5 (One cement,five sand) including curing neat finishing, etc., complete complying with standard specifiction and as directed by the departmental officers.
-
-
-
For foundation and basement
18
-
-
Brick work using Country Bricks Kiln burnt of size 8-3/4" x 4-1/4" X2-3/4"" in Cement Mortar1:6 (One cement,Six sand) including curing neat finishing, etc., complete complying with standard specifiction and as directed by the departmental officers.
-
-
-
For super structure(Ground Floor)
54
-
-
For super structure(First Floor)
56
-
-
For super structure(Second Floor)
16
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
For Footing and grade beam
160
-
-
For Column
300
-
-
For beams and slabs
660
-
-
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
22
-
-
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
1175
-
-
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
960
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
18
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200mm x 200mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
225
-
-
Painting two coats of newly plastered wall surface with Cement paint over a one coat of priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
960
-
-
Painting two coats of newly plastered wall surface withWater based Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
1175
-
-
Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (one cement three crushed stone sand), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc., complete as per standard speicification. and as directed by the departmental officers( The kota stone slabs and other materials to be used should be got approved by the Executive Engineer concerned before use on work)
315
-
-
Paving the floor with concrete eurokan anti-skid tiles Required shape and design of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
85
-
-
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
38
-
-
Supplying and fixing mild steel grills for windows, ventilators, etc. As per approved design including priming coat etc., complete complying with standard specification.and as directed by the departmental officers.
465
-
-
Supplying and Erecting Pull and Push type Rolling Shutter with ISImake of approved size and section using18GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate isinclusive of hood covers, transportation charges etc complete complying with standard specification and as directed by the departmental officers.
132
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
11
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete complying with standard specifications.
36
-
-
Painting two coats of new iron work and other similar works including zinc-chromite priming coat with two coats of best approved first quality and colour of synthetic enamel paint etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
277
-
-
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipe 110 mm dia having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
80
-
-
Supply and runof 4x6sq.mm. (84/0.3)PVCinsulatedSCunsheathedcopperconductorof1100Von7/20GI bearer wire for service connection mains
200
-
-
Supply and fixing of 3 phase 32A aerial fuse unit for 3Nos.32A fuse units(500V)on suitable Ms sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps
20
-
-
Wiring with 2x1.5sq.mm.(22/0.3)PVC insulated SC unsheathed copper conductor of 1100V grade insuitablePVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylumsheet cover with TWswitch box and 5AFT switch with continuous earth wire connection of 14 SWGTC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)
85
-
-
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed insuitable MS box in flush with wall and concealed with 3mm thick hylem sheet
40
-
-
Supplying and fixing of LED 18 watts bulp suitable for fixing it to pendent/bakelite battern holder of best approved variety and as directed by the departmental officers.
45
-
-
Supply and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp
20
-
-
Earthing as per PWD standard with an earth electrode of 2 metre Class'B' GI pipe of dia not less than 32 mm complete with necessary masonry work
1
-
-
Supply and run of 1 of No.8 SWG GI wire for earth connection
20
-
-
Supply and fixing of WT bulk head fitting with guard (Philips/Bajaj/Crompton/K.Lite) suitable for 11W CFL lamp with CFL directed by departmental officers.
20
-
-
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1"x1/8"copperflat) on TW plank of size 375mmx300mmx19mm with supporting TW reepers of 1"thick an either side with painting with suitable bolt and nuts for fixing theTW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit.
20
-
-
SUB TOTAL
-
-
-
GST 18 %
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements