Highways Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Highways Department Tender
Civil And Construction
Road Construction
Eprocure
Opening Date17 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 2,58,30,000
Costs
EMD
₹ 1,41,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tn No 26 2024 25 Hdo Dt 10 12 2024 Tvm Rf
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HWAY_511450_1Tender No
TN No 26 2024 25 HDO Dt 10 12 2024 Tvm RFTender Authority
Highways Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Road Markers/Road Stud with Lens Reflector
9926
480
4764480
... More
Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012 . ( as per MoRT&H Specification No.801)
-
-
-
... More
(90cm Equilateral triangle)
182
5126
932932
... More
(60cm Circular Boards)
107
4513
482891
... More
(90cm Octagon Boards)
6
8205
49230
... More
(60cm Equilateral triangle Boards)
52
3228
167856
... More
(80cm x 60cm Rectangular Boards)
20
6349
126980
... More
(60cm x 45cm Rectangular Boards)
34
4316
146744
... More
Providing and erecting of Direction and Place Identification Retro-reflectorised Sign made out of High Intensity Prismatic Grade Sheeting confirming to. Type-IV standards of IRC-67: 2012 land ASTM D 4956 -09, specification and fixed over 2mm thickAluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45emX45cmX60cm size including cost and conveyance of all materials, equipment. Machinery and labour with all leads and lifts, loading charges necessary For satisfactory completion of the work as directed by the engineer in charge. High intensity Retro ReJectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC157-2012 The retro- rellective sheeting shall be covered under 7 year warranty issued For field perForinance and a certified copy of three vears outdoor exposure report shall be obtained as per IRC 67 2012 (as per MORT&H Specification No.801)
-
-
-
... More
Rate per sqm (for sign having area upto 0.9 sqm) Type-IV
7.2
11491
82735.2
... More
Rate per sqm ( for sign having area more than 0.9 sqm) Type-IV
14.4
11805
169992
... More
Supplying and installation of delineators (road way indicators, hazard markers and object markers), 80-100 cm high above ground level, painted at alternatively black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 etc., complete (as per MoRT&H specification No. 806
-
-
-
... More
Road Delineators
10
2400
24000
... More
Providing and Erecting of Retro - Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 -09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm and 0.60m below ground level..The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary For satisfactory completion of the work as directed by the engineer in charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflective sheeting shall be covered under 7 year warranty issued For field perFormance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORISH Specification No.801) 30cm x 90cm rectangular
-
-
-
... More
Hazard Marker Traffic Sign
104
4000
416000
... More
Providing fixing of Rigid Median Marker double sided made of polycarbonate For impact resistance laininum loa her pact strengive an tun are used in an obamA he eradire, marker seal travel minimum Izod impact strength value of 600 J/m at room of the poly carbonate should not decrease to less than 70% of its initial value on being subjected to UV weathering as per ASTM G 155 For 1000 hours or exposure to 2 years of natural weathering. The body of the median marker shall be in the Form of an isosceles trapezoidal structure of length 15 em height and width of 10 × 10 cm. The median marker shall have fluorescent yellow retro - reflective sheeting confirming to Te XI specifications as per ASTM D 4956.Area of reflective sheeting should not be less than 70 cm2 .Edge of retro reflective shall be concealed using a grill/mesh/similar mechanism to prevent vandalism and sheeting pilferage. The logo of the manufacturer shall be embossed and painted in contrasting colour on both side of median marker For distinct identification.
-
-
-
... More
Rigid Median Marker
1954
470
918380
... More
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led
150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery - 1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation, pole painting including transportation charges, installation charges etc., complete as per standard specification.
-
-
-
... More
Solar powered Traffic Blinkers
62
25000
1550000
... More
Providing and fixing of retro-Reflectorised cautionary star sign made out of high intensity primatic grade reflective sheeting stricked over CR sheet 0.20 mm / 32.G thickness with black enamel paint firmly fixied with 1 1/2" x 14 G wire nails of size 100 mm x 100 mm.
-
-
-
... More
star sign
65
90
5850
... More
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Cantilever Informatory sign Board of Size 5.00m x 1.80m made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No.801).Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete
-
-
-
... More
Digitally Printed Retro Reflectorized Overhead Cantilever Informatory sign
Board
5
540490
2702450
... More
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign Board made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No.801).Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. of size 12.00 m X 1.8 m
-
-
-
... More
Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign
Board
3
1015160
3045480
... More
Providing and fixing of Digitally Printed Retro Reflectorized Sign Board using UV Inkjet Printer made out of cube corner micro prismatic grade sheeting of Type-XI standards of IRC 67-2012 and ASTM D 4956 – 09 specification, Digitally Printed using UV Inkjet Printer (UVIJ) for traffic colour, images/ logos/ text and laminated with clear electrocuttable film and applied to properly prepared sign substrates, fixed over 2mm Aluminium sheet with back supporting frame of 50x50x6mm Mild Steel ‘L’ angle and supported on a 150NB (Nominal Bore) pipe with 4.50mm thick with an overall height from top of the board to foundation. The sign board should be of 2.10m clear height from the ground level to the bottom of the sign board and 1.10m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete of size 450x450x1100mm including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. The Micro prismatic sheeting should have minimum 70% co-efficient of Retro-reflection values as per table 6.90 of IRC 67-2012. The retroreflective sheeting shall be covered under 10 Years warranty issued for field performance and a certified copy of 3 years outdoor exposure report shall be obtained as per IRC 67-2012. The warranty shall be inclusive of digitally printed images/ logos/ test/ legends and their bonding to the retro-reflective sheeting (as per MoRT&H specification no.801) of Size – 3.64m x 2.42m
-
-
-
... More
Digitally Printed Retro Reflectorized Sign Board using UV Inkjet Printer
2
157550
315100
... More
Providing and fixing of Digitally Printed Fluorescent Coloured Retro Reflectorized Sign Board using Latex Printer made out of cube corner micro prismatic grade Fluorescent Coloured sheeting of Type-XI standards of IRC 67-2012 and ASTM D 4956 – 09 specification, Digitally Printed using Latex printing for traffic colour, text and laminated with clear electrocuttable film and applied to properly prepared sign substrates, fixed over 2mm Aluminium sheet with back supporting frame of 50x50x6mm Mild Steel ‘L’ angle and supported on a 150NB (Nominal Bore) pipe with 4.50mm thick with an overall height from top of the board to foundation. The sign board should be of 2.10m clear height from the ground level to the bottom of the sign board and 1.10m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete of size 450x450x1100mm including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. The Micro prismatic Fluorescent Coloured sheeting should have minimum co-efficient of Retroreflection values as per table 6.90 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 Years warranty issued for field performance and a certified copy of 3 years outdoor exposure report shall be obtained as per IRC 67-2012. The warranty shall be inclusive of digitally printed test/ legends and their bonding to the retro-reflective sheeting (as per MoRT&H specification no.801). The Latex printer used for digital printing should have inks of low VOC emissions and have green guard, eco logo certificates as per UL2801 standards.of Size – 3.64m x 2.42m
-
-
-
... More
Digitally Printed Fluorescent Coloured Retro Reflectorized Sign Board using Latex
Printer
2
151502
303004
... More
Supply and fixing of Kilometre stone of standard design and drawing as per IRC:8-1980 (second revision),including painting and numbering etc., and all other incidental charges etc., complete
-
-
-
... More
Kilometre stone
12
2197
26364
... More
Supply and fixing of HM stone of standard design and drawing as per IRC:26-1967, including painting and numbering etc., and all other incidental charges etc., complete
-
-
-
... More
HM stone
44
574
25284.6
... More
Supply and fixing of RCC guide post of size1.20 x 0.20 x 0.20 m with reflective star stickers with tin M.s sheet with two side packing and top cover of 0.75 inches in RCC 1: 2: 4 Mix using 20 mm HBG ISS metal with 10 mm. dia bars as vertical with 8mm dia Stirrups including 8.25 inches x 4.25 feet mould with star shape of 5 inches and top projection by 0.75 inches x 3 inches including cost and conveyance of materials to worksite etc., complete
-
-
-
... More
RCC guide post
4
1220
4880.88
... More
Calculation of SubTotal, GST and Total Amount carried out by system automatically
-
-
-
... More
Basic cost of value put to tender as per estimate
1
21885540
-
... More
Add GST at 18%
1
3939397
-
... More
Total Value put to Tender
1
25824937
-
... More
Quoted value
1
-
-
... More
Final Quoted Value
1
-
-
... More
Add GST at 18% of Final Quoted Value
1
-
-
... More
Total Value of Contract Including 18% of GST
1
-
-
... More
Basic cost of value put to tender as per Estimate
-
-
21885540
... More
Quoted Rate in Figures (Total Value of Contract Including 18% of GST )
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%