Bhabha Atomic Research Centre Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Bhabha Atomic Research Centre - BARC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Nov 2024
Closing Date2 Dec 2024
Tender Amount₹ 64,60,000
Costs
EMD
₹ 1,29,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BARC_835716_1Bid Award Id
ViewTender No
MARC/PRPD/MW/K-2992/2024Tender Authority
Bhabha Atomic Research Centre ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Inspection and servicing of Local Safety Earth provisions and making them healthy by suitable means including pouring of bentonite/earth enhancement powder, water, replacement of earth electrode, conductor, accessories etc. for Street Light Poles/PTLs and other places as directed by department Engineer. Excavation as required for the work shall be measured separately. All the material required for the work will be provided by department.
30
-
-
... More
Painting of Street/periphery light poles (Single/Double arm) including supply of paint, Aluminium paint and all other items including numbering using stencils (enamel paint) as directed by the Engineer-in-charge.
50
-
-
... More
Painting of Post top lanterns including supply of exterior emulsion paint, Aluminium paint and all other items including numbering using stencils (enamel paint) as directed by the Engineer-in-charge.
15
-
-
... More
Cleaning of bushes, plants, garbage material etc. and making good in the surrounding area up to Two feet on all sides of Street Light poles/PTLs as directed by the Engineer-in-charge..
300
-
-
... More
Earth work excavation in all types of soil including backfilling of trenches as directed by the EIC.
750
-
-
... More
Supply & installation of plate type earth electrode including excavation, construction of Brick chamber as per drawing & as directed by the engineer in charge.
12
-
-
... More
Supply & Installation of RCC Cable route markers as detailed in the drawing containing various alphanumerical text as directed by Engineer-in-charge
3
-
-
... More
Supply and installation of Electrolytic copper in form of bare wire and flat in built in trench/cable trays/open areas as per the detailed specification.
100
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC.
For Nickel Cadmium battery bank, 110 V, 85 AH/100AH.
12
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. For Motor Control Centres (MCC) with 1 vertical section
10
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. for MCC with 2 V-sections OR Industrial pattern SWBDs
10
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. for MCC with 3 Nos. vertical section or Control panel
10
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. for MCC with 4 Nos. vertical section
10
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. for MCC with 5/ 6 V-sections OR 415 V OCB Switch Board
10
-
-
... More
External cleaning of Electrical Equipment with nylon wire brush, banian waste etc. as directed by the EIC. for 1500 KVA indoor oil filled transformer or 2 Nos. of 750KVA Dry Transformers
10
-
-
... More
Maintenance of Power and Lighting Distribution Boards located in various Buildings including RCD Testing, cleaning, tightening, repair of any burnt termination, replacement of components if damaged and painting including supply of paint.
For 4/6 Way 16/32/63 Amps Fuse Distribution boards
30
-
-
... More
Maintenance of Power and Lighting Distribution Boards located in various Buildings including RCBO/RCD testing, cleaning, tightening, repair of any burnt termination, replacement of components if damaged and painting including supply of paint.
For 4/6 Way 16/32/63 Amps MCB Distribution boards
15
-
-
... More
Maintenance of Power and Lighting Distribution Boards located in various Buildings including RCBO/RCD Testing, cleaning, tightening, repair of any burnt termination, replacement of components if damaged and painting including supply of paint.
For 8/12 Way 16/32/63 Amps Fuse Distribution boards
50
-
-
... More
Maintenance of Power and Lighting Distribution Boards located in various Buildings including RCD Testing, cleaning, tightening, repair of any burnt termination, replacement of components if damaged and painting including supply of paint.
For 8/12 Way 16/32/63 Amps MCB Distribution Bards
25
-
-
... More
Repair of single phase 5/16A switch & socket boxes in various buildings as detailed in the scope of work.
150
-
-
... More
General Maintenance and rectification of faults on portable Single Phase Power Extension Socket and Switch boards as per the scope of the work.
350
-
-
... More
Maintenance and Servicing of canteen electrical appliances as detailed in technical specification.
20
-
-
... More
Removal of termination of armoured cables from electrical equipment or reconnecting of removed termination for size up to 4C X 25 sq.mm
100
-
-
... More
Removal of termination of armoured cables from electrical equipment or reconnecting of removed termination for above 4C X 25 sq.mm and up to 4C X 70 sq.mm
100
-
-
... More
Disconnection of service connection with Energy meter board & shifting the board including connected cable.
5
-
-
... More
Maintenance of service connection meter boards (including Energy meters and switch fuse units)
5
-
-
... More
Installation of Energy meter board & providing service connection at various locations.
4
-
-
... More
Supply and installation of 18/20 W Four Feet LED Tubes for direct replacement in 4 feet Box fittings including modification of wiring as detailed in scope of work.
50
-
-
... More
Supply and installation of 50 W LED Street Light Outdoor Luminaires for street lighting poles.
5
-
-
... More
Repair of fluorescent fittings as detailed in the scope of work.
Type of Light Fitting: '1 No in 1 X 40/65 W fitting OR 1 No in 2 x 40/65 W fitting
75
-
-
... More
Testing of circuit, replacement, rewiring and energisation of street lighting LED luminaires of rating up to 100Watts.
50
-
-
... More
Testing of circuit, replacement, rewiring and energisation for Post top lantern fittings
30
-
-
... More
Replacement, rewiring and energisation of 250/400 Watt high bay SV/MV fixture at a height not more than 30 Mtrs.
15
-
-
... More
Conditioning of Power Contactors and other relays including supply of half litre CRC Spray with execution of each item.
25
-
-
... More
Installation of GI/MS boxes on brick masonry concrete wall/false ceiling/MS structure/ concealed in brick masonry with all materials, connecting the conduits with checknut of various sizes complete with making suitable holes, earthing, etc.
Box Size: Upto and including 300x300 mm size
20
-
-
... More
Installation of GI/MS boxes on brick masonry concrete wall/false ceiling/MS structure/ concealed in brick masonry with all materials, connecting the conduits with checknut of various sizes complete with making suitable holes, earthing, etc.for Box Size: exceeding 300x300 mm but upto 1000 x 1000 mm.
6
-
-
... More
Installation of GI/MS boxes on brick masonry concrete wall/false ceiling/MS structure/ concealed in brick masonry with all materials, connecting the conduits with checknut of various sizes complete with making suitable holes, earthing, etc.
for Box Size: Upto and including 300x300 mm size concealed in brick walls including chipping and replastering.
25
-
-
... More
Pulling of 3 nos. '0.75/1.0/1.5/2.5 sq mm. size single core 1100 Volts grade copper conductor wire or single/two pair Tele cable through the existing conduits/casing capping including termination at both ends. The required material will be supplied free of cost by the department.
1500
-
-
... More
Pulling of 3 nos. 4.0/6.0/10.0 sq mm. size 1100 Volts grade copper conductor wire along with earth conductor or single/two pair Tele cable through the existing conduits/casing capping including termination at both ends. The required material will be supplied free of cost by the department.
500
-
-
... More
Supply and installation of good quality Aluminium perforated/meshed Louvres suitable for 300mm Exhaust Fans at heights including minor civil works as detailed in scope of work.
5
-
-
... More
Supply and installation of good quality Aluminium perforated/meshed Louvres suitable for 450mm Exhaust Fans at heights including minor civil works as detailed in scope of work.
5
-
-
... More
Maintenance of 11KV & 6.6 kV indoor substation equipments and power supply installations in different buildings in general shift or round the clock shift as directed by EIC for attending emergencies, maintenance works as per specific technical requirements of the work and as directed by the Engineer-in-Charge. (Set = 1 Electrician + 1 Helper)
600
-
-
... More
Maintenance of Electrical installations in Bldg-1 in general shift or round the clock shift as decided by EIC for attending the emrgencies during plant operation, and other maintenance works as per specific technical requirements of the work and as directed by the Engineer-in-Charge. (1 Set = 1 Electrician + 1 Helper).
500
-
-
... More
Laying and installation of 3-1/2 C LT armoured cable (1 No) of size from 185 sq.mm up to 400sqmm OR Control Cable of size 52C x 1sqmm (1 No) in excavated trenches as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department).
500
-
-
... More
Laying and installation of Cable Size: 3-1/2 C x 120/95/70 sq.mm Cable (1 No) OR 100 pair tele. Cable (1 No) OR Control Cable of size 19C/37C x 1sqmm (1 No) in excavated trenches as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department).
150
-
-
... More
Laying and installation of Cable Size: 3/4 C x 35/16/10 sq.mm Cable (1 No) OR 30/50 pair tele. Cable (1 No) in excavated trenches as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department)
150
-
-
... More
Laying and installation of Cable Size: 5/10/20 Pair jelly filled Telephone Cable (1No) OR 3/4 C x 1.5/2.5/4/6 sq mm copper cable (1No). in excavated trenches as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department)
100
-
-
... More
Laying and installation of 3-1/2 C x 400/185 sq.mm LT armoured Cable (1 No) in built-in-trenches on cable supports, on Wall/ RCC Masonry surface as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department).
100
-
-
... More
Laying and installation of 3-1/2 C x 120/95/70 sq.mm Cable (1 No) OR 100 pair tele. Cable (1 No) in built-in-trenches on cable supports, on Wall/ RCC Masonry surface as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department)
300
-
-
... More
Laying and installation of 3/4 C x 35/16/10 sq.mm Cable (1 No) OR 30/50 pair tele. Cable (1 No) in built-in-trenches on cable supports, on Wall/ RCC Masonry surface as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department)
250
-
-
... More
Laying and installation of 5/10/20 Pair jelly filled Telephone Cable (1No) OR 3/4 C x 1.5/2.5/4/6 sq mm copper cable in built-in-trenches on cable supports, on Wall/ RCC Masonry surface as detailed in the scope of work excluding excavation but including transporting from stores to worksite and installation of cables (required cable alone will be supplied free of cost by the Department)
150
-
-
... More
Retrieval and relaying of armoured cables in size 3/3-1/2 C X 400/185 sq mm Cable (1 No) for rerouting in excavated trenches using the retrieved brick/slab at 750mm level, including supply of river sand.
300
-
-
... More
Retrieval and relaying of armoured cables for rerouting in excavated trenches using the retrieved brick/slab at 750mm level, including supply of river sand.
Cable size: 3-1/2Cx95/70/35.sqmm Cable (1 No)
100
-
-
... More
Retrieval and relaying of armoured cables for rerouting in excavated trenches using the retrieved brick/slab at 750mm level, including supply of river sand.
Cable size: 3/4 C x 10/16 sq.mm Cable (1 No) OR 30/50 pair tele. Cable (1 No)
300
-
-
... More
Retrieval and relaying of armoured cables for rerouting in excavated trenches using the retrieved brick/slab at 750mm level, including supply of river sand.
Cable Size: 5/10/20 Pair Telephone Copper Cable (1No) OR 3/4 C 1.5/2.5/6 sq. mm armoured cable (1 No)
100
-
-
... More
Retrieval and relaying of 3/3-1/2 C X 400/185 sq mm armoured cable (1 No.) for rerouting in built-in trenches on cable supports, on wall/RCC Masonary surfaces as detailed in the scope of work.
100
-
-
... More
Retrieval and relaying of Cable Size: 3-1/2Cx120/95/70/50.sqmm Cable (1 No) for rerouting in built-in trenches on cable supports, on wall/RCC Masonary surfaces as detailed in the scope of work.
100
-
-
... More
Retrieval and relaying of Cable Size: 3/4 C x 35/25/16/10 sq.mm Cable (1 No) OR 30/50 pair tele. Cable (1 No) for rerouting in built-in trenches on cable supports, on wall/RCC Masonary surfaces as detailed in the scope of work.
150
-
-
... More
Retrieval and relaying of Cable Size: 5/10/20 Pair Telephone Copper Cable (1No) OR 3/4 C 1.5/2.5/6 sq mm armoured cable (1 No) for rerouting in built-in trenches on cable supports, on wall/RCC Masonary surfaces as detailed in the scope of work.
100
-
-
... More
Temporary laying of LT cables in open air / in Built in trench for sizes up to 3.5C X 70 Sq.mm Aluminium conductor
500
-
-
... More
Temporary laying of LT cables in open air / in Built in trench
Cables of sizes more than 3.5C X 70 Sq.mm up to 3.5Cx185sqmm Aluminium conductor
300
-
-
... More
End termination of armoured cables including earthing of cable glands as detailed in the enclosed specification.
'Cable Sze: 3-1/2 C x 400/185 sq.mm or screened control cables of size 37/52 C x 1.5/2.5 Sq. mm or 50 pair Telephone cable
10
-
-
... More
End termination of armoured cables including earthing of cable glands as detailed in the enclosed specification.
for Cable Size: '3-1/2 C x 120/95/70/35 sq.mm or screened control cables of size 19 C to 37 C x 1.5/2.5 Sq. mm
10
-
-
... More
End termination of armoured cables including earthing of cable glands as detailed in the enclosed specification.
for Cable Size: '3 or 4 C x 6/10/16 sq.mm. or screened control cable of size 7 C to 14 C x 1.5/2.5 Sq. mm
30
-
-
... More
End termination of armoured cables including earthing of cable glands as detailed in the enclosed specification.
for Cable Size: '3 or 4 C X 2.5/1.5 sq mm
20
-
-
... More
End termination of armoured cables including earthing of cable glands as detailed in the enclosed specification.
for Cable Size: 5/10/20 Pair Telephone Cable
6
-
-
... More
Cleaning of cable trenches inside various buildings from dust, cobwebs, removal of debris if any etc.
Size of Trench: Upto and including 600 x 600 mm size
150
-
-
... More
Cleaning of cable trenches inside various buildings from dust, cobwebs, removal of debris if any etc.
Size of Trench: Exceeding 600 x 600 mm but upto 1000 x 1000 mm
100
-
-
... More
Cleaning of cable trenches inside various buildings from dust, cobwebs, removal of debris if any etc.Size of Trench: Exceeding 1000 x 1000 mm but upto 1500 x 1500 mm
60
-
-
... More
Supply, installation and testing of Telephone Instruments (With Caller Id)
10
-
-
... More
Supply, installation and testing of Basic Telephone Instruments (Without Caller Id)
40
-
-
... More
Supply, installation and testing of 12 V 150 AH Lead Acid Batteries for Heavy Vehicles.
2
-
-
... More
Supply, installation and testing of 12 V 100 AH SMF Lead Acid Batteries for Telephone Exchange
2
-
-
... More
Supply, installation and testing of 12 V 45 AH SMF Lead Acid Batteries for Control Supply
4
-
-
... More
Calibration and testing of Residual Current Devices (RCBO/RCCB/ELCB) of Lighting and Power Distribution boards in various buildings.
100
-
-
... More
Supply, installation, wiring and testing of 25/32 A, 2P, 30 mA leakage Current RCBO) in electrical extension boxes.
60
-
-
... More
Supply and Installation of 5 A three pin Bakelite sockets in switch boxes
10
-
-
... More
Supply and Installation of 15 A three pin Bakelite sockets in switch boxes
30
-
-
... More
Supply and Installation of 5 A three pin Bakelite Plug top
30
-
-
... More
Supply and Installation of 15 A three pin Bakelite Plug top
30
-
-
... More
Supply and Installation of 10 A three pin Metal Clad sockets in switch boxes
10
-
-
... More
Supply and Installation of 10 A three pin Metal Clad Plug top in switch boxes
10
-
-
... More
Supply of rectangular / circular pre-fabricated MS Earth Pit cover plates.
5
-
-
... More
Supply and installation of Four Feet Box type Fitting at a height up to 5mtr. including 2 No. of side holders (Without choke/ballast/Tubes/Diffuser) retrofitting works in existing 4/5 Feet Fluorescent Fittings on false ceiling/open ceiling/down rods/brick or concrete walls, wiring and energisation etc. as detailed in scope of work.
150
-
-
... More
Supply and Installation of 5 A Crabtree Switchs
250
-
-
... More
Supply and Installation of 10 A Crabtree Switchs
250
-
-
... More
Supply and Installation of 20 A Crabtree Switchs
250
-
-
... More
Supply and Installation of BCH make 63 A Industrial (Metallic) Plug and Socket Set.
3
-
-
... More
Supply and external installation of 25mm Dia, 2mm wall thickness Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, as per the detailed specification.
115
-
-
... More
Supply and Installation of 18/20 W Round Recessed Fittings.
100
-
-
... More
Supply and installation of 6 A / 10 A / 16 A / 20 A / 25 A / 32 A, Single Pole, 10kA, C curve (IEC-60747-2) MCBs in Extension Boxes and distribution boards.
250
-
-
... More
Supply of HG/NS types fuse link suitable for FD 20H/20P/20B/32H/32P/32B fuse base in various ratings of 2 A, 4A, 6 A, 8 A, 10 A,16 A, 20 A, 25 A with fuse size (F1) .
300
-
-
... More
Supply of 12 Modular Crabtree Cover
60
-
-
... More
Supply of 8 Modular Crabtree Cover
61
-
-
... More
Supply of 3mm thick Hylam sheet (4 feet x 2 feet) and its installation for electrical extension boxes and Distribution Boards of various sizes including supply of fasteners and fabrication works.
15
-
-
... More
Supply and installation of 2 Ton Split AC as per scope of Technical Specifications in Annexure.
1
-
-
... More
Supply and fixing of 26x18x5mm size high quality Sm2Co17 Magnets in magnetized condition (magnetised through 5mm) as per the technical specifications.
112
-
-
... More
Testing of Transformer Oil Sample including Furon Analysis and providing of detailed results, certificates and documentation in NABL format as per the technical specifications and as directed by Engineer-in charge.
8
-
-
... More
Calibration of 3.5 Digits Digital Multimeter including providing of NABL accredited certificates and documentation.
3
-
-
... More
Calibration of 4.5 Digits Digital Multimeter including providing of NABL accredited certificates and documentation.
2
-
-
... More
Calibration of Tachometer up to 10000 RPM including providing of NABL accredited certificates and documentation.
2
-
-
... More
Calibration of Digital AC/DC Clamp Meter up to 1000 A including providing of NABL accredited certificates and documentation.
2
-
-
... More
Calibration of Digital AC/DC Clamp Meter up to 20 A including providing of NABL accredited certificates and documentation.
2
-
-
... More
Calibration of High Voltage Tester up to 1 KV including providing of NABL accredited certificates and documentation.
2
-
-
... More
Calibration of High Voltage Tester up to 5 KV including providing of NABL accredited certificates and documentation.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements