State Agricultural Marketing Board Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
State Agricultural Marketing Board Tender
Eprocure
Opening Date26 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 1,23,00,000
Costs
EMD
₹ 1,47,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TAMBC_514174_1Bid Award Id
ViewTender No
TNSAMB-2024-38-03Tender Authority
State Agricultural Marketing Board ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
146.5
-
-
... More
Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification.
324.5
-
-
... More
Cement concrete 1:5:10 (One cement five M sand and ten broken Machine crushed stone jelly) using HBG Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.
152
-
-
... More
Plain Cement Concrete 1:2:4 (one cement, two M sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
55.4
-
-
... More
Reinforcement Cement Concrete 1:1-1/2:3 (One Cement, One and a half M sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three M Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
-
-
-
... More
Foundation and Basement
130.6
-
-
... More
For Ground floor
35.6
-
-
... More
Cement Concrete 1:3:6 (One Cement, Three M sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three M Sand and Six hard broken stone jelly).
159.39
-
-
... More
Vacum dewatering on freshly laid and thoroughly vibrated concrete surface to produce a homogeneous and smooth concrete surface .Suction matshall be spread over the levelled fresh concrete surface and shall be connected by the suction hose to the vaccum pump for dewatering of surplus water in the concrete . After dewatering is complete , the concrete surface is trawled with minimum two passes to achieve a wear resistance concrete surface
360
-
-
... More
Supplying fabricating and placing in position steel reinforcement using mild steel or ribbed star rods for all RCC works as per the design given including cost of steel and binding wire also in all floors steel and binding wire shall be supplied by the contractors etc., complying with standard specifications.
139.77
-
-
... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
-
-
-
... More
a) For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,
414.5
-
-
... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid)
-
-
-
... More
a) For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
146.3
-
-
... More
c) For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
248.4
-
-
... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
179.42
-
-
... More
Brick work in following Cement Mortar 1:5 using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction.
-
-
-
... More
For foundation & basement
8.5
-
-
... More
In Ground floor
4.2
-
-
... More
Supplying and laying high strength flexible geogrids (HSFG) as soil reinforcement/ basal reinforcement sa per MORTH 3100 and IRC 113, made of high tenacity polyester core with polyethylene coating with Minimum long term Design strength (LTDS) of more then 50% of ultimate Tensile strength at 30 degree Celsius corresponding to 12% strain. Ultimate Tensile Strength – 100 kn/m
382
-
-
... More
Brick work in following Cement Mortar 1:6 using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and for superstructure including curing, etc., complete complying with standard specifiction.
-
-
-
... More
For foundation & basement
21.3
-
-
... More
In Ground Floor
73.5
-
-
... More
Brick partition walls of 11.50cm thickness using best quality II Class Table Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
-
-
-
... More
For Ground floor
1.2
-
-
... More
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
4
-
-
... More
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two M sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
13.5
-
-
... More
Plastering with Cement Mortar 1:5 (One cement and Five M sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
915.5
-
-
... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc.,in all floors complying with standard specification and as directed by the departmental officers
277.2
-
-
... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of Paris putty, wherever required etc., complete complying with standard specification.
1337.45
-
-
... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
72
-
-
... More
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
2
-
-
... More
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
2
-
-
... More
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
1
-
-
... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
-
-
-
... More
75mm Dia
5
-
-
... More
110mm Dia
20
-
-
... More
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
-
-
-
... More
20mm Dia
10
-
-
... More
32mm Dia
20
-
-
... More
40mm Dia
10
-
-
... More
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
-
-
-
... More
PVC Elbow
-
-
-
... More
75mm Dia
1
-
-
... More
110mm Dia
5
-
-
... More
Supplying and fixing of 1000 litres capacity PVC water tank with IS specification IS 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary.
1
-
-
... More
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two M sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
2
-
-
... More
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
6
-
-
... More
Supplying and fixing in position best quality and approved make Indian made white / glazed earthernware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
1
-
-
... More
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
3.2
-
-
... More
Fabricating and supplying and erecting the required number of trusses with structural steel members like angle iron MS plates for all truss members including cleats to receive the purlines all cutting drilling holes welding and fixing of members with necessary bolts nuts anchor bolt of approved quality hoisitn aligning and glazing the trusses inposition as per plan. The rate should include the cost painting the members with one coat of red oxide primer and zinc chromate etc., complete complying with standard specification and an directed bya the departmental officers.
9765
-
-
... More
Supplying and laying of Profiled Galvalume Sheet of TCT 0.47 mm and standard width of 1.060 mm with yield strength of 550 MPA of approved quality for roofing with necessary U or J bolts and unts bitumen GI washers washers etc., complete complying with standard specification.
455.4
-
-
... More
Supplying and laying of Gal volume sheet ridge pieces approved quality with necessary U or J bolts and nuts GI washers etc., complete complying with standard specification.
31
-
-
... More
Providing Groove cutting in flooring concrete for 10mm width and 20mm depth and filling the groove with combination of Anabond Tuffseald 2G and bitumen tar including cost of all materials and labours etc complete.
280
-
-
... More
Supplying and fixing of rolling shutters with ISI mark shall be of pull and push type made out of 18/Gauge x3’’ lathe sections which consists of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below; Curtain; Shall be of 18/Gx3' lath sections cut to required size and filled with heavy cast iron/ M.S. Clips for 8'0"[2.45m] high rolling shutter lathe sections provided shall be not less than 37 numbers. Lock Plate; Shall be 10gaue M.S.Sheet reinforced with 40mmx 6mm M.S angles at the bottom and fitted with heavy latches of 12mm thick locking arrangements on either sides. There should be one handle on either side Guide channel; Pressed guide channels shall be of 10 gauge M.S.Sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10 Gauge angle M.S.Plate and cost iron 'U' clamps shall be reveted to the side brackets Roller; Shall be of heavy cast iron pullies fitted with heavy duty C' Class 40mm steel pipes and high tensile high carbon coil springs-2 springs shall be supplied. Supplying and fixing of Hood Cover; Shall be of 0.9mm CRCA sheet reinforced with 25mm x 25mm x 3mm M.S. angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated with heavy coat of zinc chromite primer. The above specifications for various components of rolling shutter shall be invariably followed and verified with the rolling shutters supplied by the firms at site. If the rolling shutters supplied do not confirm to the above specifications, the concerned firms should be asked to replace the shutter or supply the missing components
-
-
-
... More
Manually operated (up to 8 m2 area)
24
-
-
... More
Manufacturing and supplying and fixing in position of 'N' type ventilators of required size made out of 25x25x5mm MS "L" angles frames alround the ventilator. MS TEE of 25x25x5 mm to be fixed in between the frames at 30 cm intervals. Hold fast to be used 25x25x5 mm "L" angle 23 cm length 4 Nos. 3 mm pin headed glass to be fixed in-between the angles by using Teak wood beadings of size 15x12 mm with screw, washer and nut wherever necessary. In the inclined portion, 1"x1" weld mesh to be embedded by using 25x5 mm Flat at 30 cm centre to centre. 12 mm sq. steel rods to be fixed horizontally between the frames in vertical portions at 10 cm centre to centre (approximately). The rate inclusive of transporting charge, dismantling, redoing to the original condition, one coat of red oxide primer etc., complete complying with standard specification and as directed by the departmental officers.
6.21
-
-
... More
Supplying and fixing in position of Iron grills of required size using 32 x 32 x 6mm angle around and 2 Nos of vertical at center with MS flats diagonally to the existing open space for grills into necessary hold fast conveyance and one coat of primer etc., complete
330
-
-
... More
Providing Pre construction of Anti termite Treatment for the Construction of building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment, spraying chemicals and other incident charges etc.,complete. The rate shall be inclusive of giving anti termite treatment to the building for the following four stages including breaking the termite moulds, making holes with crow bars at an interval of 30 cms to a depth of 50 cms in the pheriphery of building and pouring chemicals etc., complete as per ISI 6313 ( Part 2) 2001. The antitermite chemical chloropyriphos 20 EC used should form 0.5% concentrate for the entire operation etc., as directed by the Engineer in charge and including cost of chemicals labour transportation etc.,complete
380
-
-
... More
Stage 1: Spraying Anti termite treatment chemical solution for the foundation before laying the foundation concrete at bottom and sides of the foundation.
-
-
-
... More
Stage 2: Spraying Anti termite treatment chemical solution to the grade beam level, spraying has to be done for the grade beam, brick masonry in the super structure in contact with back fill earth.
-
-
-
... More
Stage 3: Spraying Anti termite treatment chemical solution on sand for the flooring before laying the flooring concrete; the treatment has to be carried out on the sand filling in basement and after leveling operation is over.
-
-
-
... More
Stage 4: Spraying Anti termite treatment chemical solution around the building on outside by making crow bar holes at an interval of 15 cms to a depth of 30 cms before laying the plinth projection. These holes have to be closed after the treatment.
-
-
-
... More
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator)
53
-
-
... More
Supply and fixing of 18 W LED single industrial type flu.fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from the terminals to the fitting with flu.tube..(Philips/Crompton/Wipro.
2
-
-
... More
Supply and fixing of 2x36w CFL type street light fitting with complete with 32mm dia G.I. pipe class 'B with 1 No 32mm G.I. Bend complete on the existing post / well with 16A aerial fuse unit on MS plate with PVC unsheathed copper leads, MS clamps and aluminium paiting with 2 Nos 36w CFL. (Make CG SCE 13236EB / equivalent)
1
-
-
... More
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point
6
-
-
... More
Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 15A 3 pin flush type non inter locking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point
6
-
-
... More
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire onnection of 14 SWG TC wire with painting of suitable colour.
120
-
-
... More
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board insheetsteel enclosure double door (metal) with 40A4 pole MCB isola terasincoming and 12Nos. 6Ato 32 ASP MCB as out going inflush with wall and making good of the concealed portion with earth connection.The MCBDBandMCB's should be with the ISI mark(like standard make)
1
-
-
... More
Supply and run of 4 x 6 sq.mm (84/0.30) insulated SC unsheathed Cu . Conductor of 1100 V grade in 25mm did GI pipe ( Class -B ) bend at both ends with necessary angle iron up right and end supports for mains. ( SD . 73 )
15
-
-
... More
Supply and run of 4 x 6 sq.mm (84/0.3) pvc insulated SC unsheathed Cu.Conductor of 1100V on 7/20 GI bearer wire for service connection mains . ( SD .68)
55
-
-
... More
Supplying and fixing TNEB Meter Board suitable for 3 Phase 63 A Service connection made up of suitable angle iron frame work of size 2 feet 1 1/2 using angleiron of size 1 1/2 x 1 1/2 x 1/4 riddly fixed on wall covered with hylem sheet of size 2 feet x1/2
1
-
-
... More
Supply and laying of 2 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (sd.199)
49
-
-
... More
Supply and fixing of 4'40W twin street light fluorescent fitting complete with copper choke and condensor with 19mm dia GI pipe (Class 'B') with 1 No. 19mm GI bend complete on the existing post / wall with 16A aerial fuse unit on MS plate with PVC unsheat FRLS copper leads with MS clarnps and aluminium painting with fluorescent tubes
10
-
-
... More
Supply and fixing of 4'40W single industrial type fluorescent fitting complete with copperchoke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from the terminals to the fitting with fluorescent Tube SD 92
16
-
-
... More
Supplying and Run of 2 of 4sq.mm (56/0.30) PVC insulated SC unsheathed copper conductor cable of 1100V Grade on 7/20 GI bearer wire for service connection mains. (SD No.70)
28
-
-
... More
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
1
-
-
... More
Supply and run of 1 of No.8 SWG GI wire for earth connection. ( SD 74 )
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements