AAI Cargo Logistics And Allied Services Company Limited Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
AAI Cargo Logistics And Allied Services Company Limited - AAICLAS Tender
Eprocure
Opening Date21 May 2021
Closing Date14 Jun 2021
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_AAICL_77721_1Bid Award Id
ViewTender No
AAICLAS/FMC/FIRE-25/2021-2022Tender Authority
AAI Cargo Logistics And Allied Services Company Limited ViewPurchaser Address
-Website
http://https://aaiclas-ecom.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SUB HEAD: II (ARC Works- to carryout the works, Separate manpower other than manpower mentioned in SH:I Should be deputed when as required basis)
-
-
-
Dismantling of existing split case/ radially split case type Centrifugal pump sets of following make/ models for necessary overhauling/ repairing i/c supply and replacement of both side bearings, mechanical seal, petty materials like stud bolts, gland packing, gasket, rubber bush for coupling etc. Cleaning and Greasing of bearings, reassembling, realignment of the pump with motor, testing, commissioning and painting etc. complete as required.
-
-
-
Kirloskar 85HP to 100 HP
2
-
-
Kirloskar 60HP to 75 HP
1
-
-
Kirloskar/Mather-platt 15HP
2
-
-
1-5HP
1
-
-
Dismantling of following valves from the existing fire fighting water pipe line, Complete removal of scale deposits by acid dipping, scrapping and overhauling, replacement of packings, nut & bolts and gaskets etc. as required & reinstalling the same in its original postion i/c. testing and commissioing complete as required.
-
-
-
For 10" and 12" Gate/Non Return/Globe/Foot valves
4
-
-
For 6" and 8" Gate/Non Return /Foot valves
9
-
-
From 2" to 4" Gate/Non Return/Foot valves
3
-
-
Dismantling of following damaged Ms Heavy class pipes from the system which are on surface, supplying and installing new MS Heavy class pipes complete with flanges, bends, tees, supports etc. by welding with approved make & specifications as required.
-
-
-
25mm (IS: 1239, Heavy class)
30
-
-
50mm (IS: 1239, Heavy class)
20
-
-
80mm (IS: 1239, Heavy class)
30
-
-
100mm (IS: 1239, Heavy class)
30
-
-
150mm (IS: 1239, Heavy class)
200
-
-
200mm (6.35 mm Thick)
10
-
-
250mm (6.35 mm Thick)
10
-
-
SUB HEAD: III BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
-
-
-
80mm dia (PN 1.6 Rated)
1
-
-
100mm dia (PN 1.6 Rated)
5
-
-
150mm dia (PN 1.6 Rated)
10
-
-
Providing and fixing the following size of Non return valves of approved make after dismantling the existing damaged one i/c replacement of the gasket, nut, bolts etc. as required.
-
-
-
100 mm Non return valve
2
-
-
150 mm Non return valve
3
-
-
Dismantling of following existing faulty sprinkler flexible hose drops from the system, which are inside the false ceiling, supplying and installing new flexible hose drops up to 1.5Mtr Length along with all required connectors, threading, coupler etc. as required.
10
-
-
Providing one welder and one Khallasi along with Electric welding/ gas cutting machine and welding rods/ Oxygen Acetlyne gas for carrrying out leak arresting/ welding of fire fighting hydrants or other welding works during any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency work as and when required.
10
-
-
Supply & replacement of following suitable parts in hydrant delivery/ Landing valves(Single/ Double head), First aid Hose reel drums, other related accessories and valaves in Fire hydrant and sprinkler system (as and when required basis).
-
-
-
Coupling washer
50
-
-
Seating washer
50
-
-
Gasket of suitable thickness
10
-
-
Nut bolts 12mm dia, 3" long
20
-
-
Rubber hose 20mm x 30 Mtr. Suitable for First aid Hose reel drum
5
-
-
O ring seal inside First aid Hose reel drum
30
-
-
25mm forged brass Ball Valve
10
-
-
Brass Shutoff Nozzle with 1/2" ball valve
10
-
-
Hose clamps for rubber hose
20
-
-
25mm GM Air release valve (Screwed type)
10
-
-
Supply and replacement of 100mm dia Pressure guages, 0-200PSI, H. Guru make or as per the approved make, specifications & directions of E.I.C.
2
-
-
Supply & replacement of pressure switch suitable for the existing system with a pressure range of 1 to 10 Bar.
2
-
-
Disconnecting and dismantling of burnt out Induction motor from the system. Complete dismantling of burntout stator winding and through cleaning of stator slots. Rewinding the stator with Class 'F' polyester coated super enameled copper wire and insulating materials i/c. baking, varnishing, finishing and refixing the stator in the motor frame & re-installation in Fire pump room including transportation to and from Pump room etc as required. (Rebate for taking away the burnt copper winding shall be considered while rate quoting done by the contractor)
-
-
-
60 to 75HP
1
-
-
15 HP
1
-
-
1 to 3HP
1
-
-
Painting with two coats of Synthetic enamel paint of approved shade and colour over a coat of red oxide primer over pipe lines including cleaning/ scrapping and remarking the existing indications/numbers with white paint/sticker etc., as required.
400
-
-
Providing & fixing of MS fire Hose box with mounting accessories as per standard with complete as required.
3
-
-
Supply and replacement of SS holding lugs for hydrant valve with complete as required.
20
-
-
Providing & fixing of female coupling of 1 to 2 inch size with nut and bolt with complete as required.
3
-
-
Providing & fixing of MS wheel with nut and bolt with suitable of exisiting for fire hydrant valve as complete as required.
10
-
-
Providing & fixing MS trim kit and gong bell for alarm valve 150 NB with nut and bolt with complete as required.
1
-
-
Supply of 15 mm and 50 mm ball valve with complete as required.
-
-
-
15mm
3
-
-
50 mm
3
-
-
Providing & fixing of pressure gauge needle valve set with suitable exiting pipe complete as required.
2
-
-
Providing & fixing of hose reel nozzle in the exisiting First aid hoze reel with suitable nut and bolt with complete as required.
2
-
-
Providing & fixing of hydrant valve PVC cap, disk washer with nut and screws with suitable existing complete as required.
5
-
-
Providing & fixing of MS key & SS branch with washers etc with complete as required.
10
-
-
Providing & fixing of suitable glass with screws and nuts with exisiting fire box complete as required.
10
-
-
Providing & fixing of fire fighting hose with nut in fire box each length of 15 meters with suitable couplings etc, complete as required.
6
-
-
Providing & fixing of Nipple for sprinkler drainage drain line with complete as required.
2
-
-
Providing & fixing of 150 mm dia MS C class heavy type pipe with double type welding, Suitable Bends and arrenging scoffoding with proper jointing with nut ,bolt and channel in the pipe fixing above surface and below false ceiling with complete as required with the direction of E.I.C
50
-
-
Supply of distilled water with complete as required.
50
-
-
Providing & fixing of 200 mm PN16 Butter fly valve wheel type with suitable nut and bolt with washers complete as required.
1
-
-
Providing & fixing of 250 mm PN16 Butter fly valve wheel type with nut and bolt with washers complete as required
1
-
-
Supply of 25mm ball valve with complete as required.
5
-
-
Suppy & fixing of hose reel drum set with hose 20mm x 30 mtr, hose reel nozzle with nut, bolt, clamp etc. complete as required.
2
-
-
Providing & fixing of single headed fire hydrant Landing valve with suitable bolt nuts and gaskets, etc., with complete as required.
2
-
-
Numbering of Fire hydrant box/Fire hydrant landing pipe with double coated Red enamel paint with numbering in white paint of suitable size as complete as required
20
-
-
SUB HEAD: IV - Fire Alarm system Monitoring & Maintenance of Fire Alarm & PA Systems at cargo admin block Export & Import shed courier sections CUDCT area and all other buildings annexes in coming under the Intergrated Air Cargo complex Chennai, Airport as per inventory comprising of Fire Alarm system (Low Ceiling) & few items(high ceiling), including maintaining records/ reports/ Supervision of the total system etc up to the specifications & directions of Engineer-In-Charge.
(Refer Annexure-A2 for inventory of Fire alarm system, Annexure-B2 for monitoring & maintenance activities,
Annexure-C for man power)
-
-
-
For First Year
12
-
-
For Second Year
12
-
-
Providing mobile communication facility at two locations with minimum monthly topup of Rs. 300/- for each mobiles etc., as required for the entire contract period.
-
-
-
For First Year
12
-
-
For Second Year
12
-
-
SUB HEAD: V SUPPLY OF SPARES AS AND WHEN REQUIRED BASIS. (Separate manpower)
Fire Alarm Accessories
-
-
-
Providing & Fixing of Single Input Module complete as required. SIGA-CT1. Make: Honeywell/EST
5
-
-
Providing & Fixing of Detector Base - Standard complete as required. SIGA-SB. Make:Honeywell/EST
50
-
-
Providing & Fixing of Intelligent Fixed Temperature Heat Detector - 135F complete as required. XLS-HRS. Make:Honeywell/EST
1
-
-
Providing & Fixing of Isolator Module complete as required. XLS-IM. Make: Honeywell/EST
2
-
-
Providing & Fixing of Intelligent Photoelectric Smoke Detector complete as required. XLS-PS. Make: Honeywell/EST
50
-
-
Providing & Fixing of Control relay module complete as required. SIGA - CR. Make: Honeywell/EST
10
-
-
Providing & Fixing of Manual pull station - Lexan complete as required. XLS-278. Make: Honeywell/EST
20
-
-
Supply of 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable complete as required.
1000
-
-
Laying of one number 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable on surface for fire alarm circuit etc., complete as required.
1000
-
-
Providing & Fixing of Pla relay complete as required. (Pla mpc-2c-24D-5A-L)
2
-
-
Providing & Fixing of power supply for Pla relay complete as required. (230/24v Dc)
1
-
-
Sub Head - VI
Supply of following items for recharging / maintenace of fire extinguishers
-
-
-
Printed Stickers with required information as per Instruction of EIC
300
-
-
Dry Type chemical Powder for fire extinguishers
500
-
-
Evaluation Notes How It Works ?