NHPC Limited Tender
View complete overview of Sikkim NHPC Tender
NHPC Limited - NHPC Tender
Eprocure
Opening Date18 Oct 2021
Closing Date8 Nov 2021
Tender Amount₹ 3,35,131 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_NHPC_653139_1Bid Award Id
ViewTender No
NH/RPS/ECD014(12)/1/2021- ECD/001743/302Tender Authority
NHPC Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Internal Electrification of Work Shop Office and Store and restoration of HRT HT (11KV) Line at Rangit Nagar Colony, Rangit Nagar
Internal Electrification of Work Shop Office and Store and restoration of HRT HT (11KV) Line at Rangit Nagar Colony, Rangit Nagar
BOQ Items
... More
Ventilating Fans 250mm 10" (Havells)
1
-
-
... More
LED Flood Lights Confirming to IS:16101 LED Flood Light 45 Watt
8
-
-
... More
Surface mounted CRCA LED Panel Confirming to IS : 16102 LED CRCA Panel 18W ECW 1x1 ft.
9
-
-
... More
Concreting of 11Mtrs Lattice Structure / Swaged STP in 1:4:8 cc in 0.9x0.9x2.05mtrs cement plaster of parapet in 1:4 mix.
1
-
-
... More
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate
2
-
-
... More
Concreting of H.T Guy Assembly in 1:4:8 cc in 0.40x0.40x1.05mtrs Pit.
2
-
-
... More
G.I Earth Spike conforming to IS 227.
1
-
-
... More
G.I Strips 35x6 mm of 1 Mtr length conforming to IS 227.
1
-
-
... More
Danger Board 11000Volts
1
-
-
... More
Anticlimbing Device GI Barbed Wire
2
-
-
... More
GI Wire 8 SWG
9.83
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
48
-
-
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
46
-
-
... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 100 mm X 100 mm X 60 mm deep
22
-
-
... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 180 mm X 100 mm X 60 mm deep
16
-
-
... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
22
-
-
... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
22
-
-
... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch
16
-
-
... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
16
-
-
... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
2
-
-
... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
5
-
-
... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
1
-
-
... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
40
-
-
... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
17
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
346
-
-
... More
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
3
-
-
... More
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
82.74
-
-
... More
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
82.74
-
-
... More
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres
2
-
-
... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements