Military Engineer Services Tender
View complete overview of Sikkim MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Jun 2022
Closing Date26 Jul 2022
Tender Amount₹ 42,87,000
Costs
EMD
₹ 85,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_530130_1Bid Award Id
ViewTender No
8058ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish of the site complete all as directed (reinforcement cut as required to facilitate demolition).
17.2
-
-
... More
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid in cement mortar complete all as specified and as directed.
6
-
-
... More
Dismantling of wall and ceiling hard boards/AC sheets(Fibre pulp insulation etc) or insulation board and plywood in any thickness & any position including cover fillets complete all as specified and as directed.
190
-
-
... More
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), removing from the Sites and rubbish off the premises, complete all as specified and as directed.
240
-
-
... More
Taking down chowkats with shutter of any description (without taking down shutter from the frame) n.exc 1.5 Sqm each and removing from site complete all as specified and as directed.
8
-
-
... More
Taking down chowkats with shutter of any description (without taking down shutter from the frame) exc 1.5 Sqm and n.exc 4.00 Sqm each and removing from site complete all as specified and as directed.
4
-
-
... More
M&L for 75mm thick PCC type C-2 (1:3:6) using 40mm graded aggregate in plinth protection path/hardstanding/drain bed/Jhura bed finished cement concrete surfaces fair and even including forming construction joints filled with CM (1:6) complete all as specified and as directed.
155
-
-
... More
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
27
-
-
... More
Material & labour for precast PCC 1:3:6 type C1 (by using 20mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed by the Engr-in-Charge.
4.2
-
-
... More
M&L for rendering 20mm thick in cement mortar (1:4) in two layer of 10mm thick each with using WPC shall be mixed with cement mortar in finishing outer layer only as per manufacturer's instruction, on other than fair face of brick/stone masonry (external surfaces) finished surface fair and even without using extra cement complete all as specified and as directed. Note : (WPC shall be measured and paid separately as supply only)
120
-
-
... More
M&L for flush pointing IN cm (1:4) to block in course or ashlar masonry or concrete block walling complete all as specified and as directed.
6
-
-
... More
M&L for rendering 15mm thick in cement mortar (1:6) on fair face of brick or concrete surfaces finished surface even and smooth without using extra cement complete all as specified and as directed.
120
-
-
... More
M&L for applying two coats of exterior acrylic emulsion painting over a coat of alkali resistant primer including scafolding upto 15m height and preparation of old/new surface complete all as specified and as directed.
200
-
-
... More
M&L Preparation of newly or previously plastered surfaces of walls and applying three coat of white wash on new surfaces of walls complete all as specified and directed.
20
-
-
... More
M&L for applying two coats of white wash on old plastered wall surface including preparation of old surfaces of wall complete all as specified and as directed.
40
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer applied over 3mm thick super fine Birla or altek wall care putty finish complete all as specified and as directed.
120
-
-
... More
Complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc and applying two coats of oil bound distemper over a coat of primer over super fine Birla or altek putty finish as required and complete all as specified and as directed.
650
-
-
... More
S&F powder coated grid frame work for false ceiling comprising of the following sections for making partitions of 600 x 600m size fixed to walls with rawl plugs & screws and hanged to roof with and including 1mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mm x 23mm x 0.3mm thick, cross tee shall be 24mm x 23mm x 0.3mm thick and wall angle shall be 20mm x 20mm x 0.3mm thick complete all as specified and as directed.
190
-
-
... More
M&L 4 mm thick E-board for insulation and accoustic purposes, 595 x 595 mm in size,fixed with staple on snap gird as in ceiling with and including dusting of surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
190
-
-
... More
Hacking out old broken glass any thickness, size, quality or description from wooden frames glazed with putty complete all as specified and as directed.
2
-
-
... More
S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
0.17
-
-
... More
M&L for 2nd class hardwood timber scantling of any size or in any position such as truss, purlin etc and if in repairs, to replace old and decayed timber (including piercing, scarifying etc of old and new timbers if required) and removing defected portions to store complete all as specified and as directed.
0.25
-
-
... More
M&L for 35mm thick 2nd class HW plain, framed, paneled shutters (two panel) with lock rail and panel of 9mm thick BWR commerical ply or 12mm veneered particle board with commercial face veneering on both faces. The size of rail & site as per IS : 1003 (Part-I), Kiln, seasoned & chemically pressure, treated complete all as specified and as directed.
6.74
-
-
... More
M&L for 30mm thick 2nd class hard wood well seasoned glazed and skeleton shutters, open rebated and prepared to receive glass gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified and as directed.
8.5
-
-
... More
Material and labour for 2nd class hard wood fillets, square, rectangular and triangular in section, wrought, secured with nails,sectional area exe 6 Sqcm but n.exc 13 Sqcm in section complete all as specified and as directed.
13.5
-
-
... More
S&F Mild steel butt hinges 100mm long, medium weight, cold rolled complete all as specified and as directed.
12
-
-
... More
S&F Mild steel butt hinges 75mm long, medium weight, cold rolled complete all as specified and as directed.
32
-
-
... More
Supply and fix 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by the Engr-in-Charge.
8
-
-
... More
S&F Aluminium anodised barrel tower bolts, 100 mm long, of extruded section complete all as specified and directed by the Engr-in-Charge. .
24
-
-
... More
S&F 150mm long aluminium handles, cast type, anodised complete all as specified and as directed.
8
-
-
... More
S&F 100mm long aluminium handles, cast type, anodised complete all as specified and as directed.
16
-
-
... More
S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed.
4
-
-
... More
M&L preparation of new or previously untreated wooden surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
33
-
-
... More
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
50
-
-
... More
M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
8.4
-
-
... More
M&L for preparation of new or previously treated steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of syntheitc enamel paint over old steel surface complete all as specified and as directed.
15
-
-
... More
S&F 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
4.5
-
-
... More
S&F in repair stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
6.5
-
-
... More
M&L preparation of old or previously treated wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint over wooden surface complete all as specified and as directed.
80
-
-
... More
S&F in repair 2nd class hard wood weather boarding, clean sawn, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps with nails etc complete all as specified and as directed.
25
-
-
... More
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified and as directed.
4.2
-
-
... More
Material & labour for non skid coloured ceramic tiles of 7 to 8mm thick ( Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floors etc conforming to IS-13712, grade B-II-(a) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including cement screed bed/bedding layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.
30
-
-
... More
All as per Sl item No. 45 here-in-above but on vertical surface of wall like skerting/dado etc on 15mm thick rendering complete all as specified and as directed.
5
-
-
... More
M&L for Dark shade vitrified ceramic tiles 10mm thick (Square/Rectangular) polished, area of each tiles not exceeding 0.36 Sqm, as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed/bedding layer in cement mortar (1:6) complete all as specified and as directed.
185
-
-
... More
All as per Sl item No. 47 here-in-above but on vertical surface of wall like skerting/dado etc on 15mm thick rendering complete all as specified and as directed.
20
-
-
... More
M&L RCC (Nominal mix) type B1, 1:2:4 using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
0.5
-
-
... More
M&L for mild steel TMT bars, 10mm dia and over cut to length, bent to shape required including cranking, bending spirally, hooping for columns, hookings ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
690
-
-
... More
M&L for labour for Mild steel TMT bars 5mm dia and over upto including 10mm dia as in stirrups, spacers and binders cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
410
-
-
... More
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays betwen floors and beams etc complete all as specified and as directed.
5
-
-
... More
Disconnecting existing tanks of capacity exc 500 ltr but n.exc 1000 Ltr setting aside (or lowering if required) for repairs clenaing etc and hoisting if required reconnecting and refixing in position (Cleaning repairing etc shall be measured & paid separately).
1
-
-
... More
S&F in repairs decorative type curtain rod, chromium plated with fixing brackets, stops and complete fitments complete all as specified and as directed.
32
-
-
... More
Supply only integral Water Proofing Compound, conforming to IS-2465-2003 of approved make complete all as specified and as directed.
10
-
-
... More
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof padding, roof curbs to bring top surface of slab in slope including finish the surface even and fair complete all as specified and as directed.
15.5
-
-
... More
M&L for 15mm thick rendering in cement plaster in CM (1:4) in two layer on fair faces of stone masonry wall including finish the surface even and fair with using extra cement complete all as specified and as directed.
340
-
-
... More
M&L for cutting of the construction joints 'V' shapped grooves and patching the 'V' shaped grooves with cement, admixed with quick setting compound complete all as specified and as directed
100
-
-
... More
M&L for fixing the PVC nozzels on the surface of grooved concrete surface of water tank and grouting with quick setting compound complete all as specified and as directed.
472
-
-
... More
M&L for grouting by injectinxture wiht intraplast EP/Arm grout through the PVC nozzles provided with high pressure injection pump complete all as specified and as directed.
442
-
-
... More
M&L for applying entire damaged wall surface and additional buffer zone of water storage tank with one coat of flexible acrylic polymer coating TOP GUARD complete all as specified and as directed.
340
-
-
... More
M&L for applying entire damaged wall surface and additional buffer zone of water storage tank with two coat of edible grade water base epoxy TANK COAT complete all as specified and as directed.
340
-
-
... More
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in beam, band, wall etc with any span complete all as specified and as directed.
23.1
-
-
... More
M&L for formwork to faces of walls, retaining wall etc, vertical or batter for rough finished surface complete all as specified and as directed.
50
-
-
... More
Labour only for drilling holes for bolts, pipes etc n.exc 25mm dia as in concrete surface complete all as specified and as directed.
20
-
-
... More
M&L for applying two coats of exterior acrylic emulsion painting over a coat of alkali resistant primer including scafolding upto 15m height and preparation of old/new surface complete all as specified and as directed.
125
-
-
... More
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting in soft/loose soil for foundation complete all as specified and as directed.
42
-
-
... More
M&L for PCC 1:3:6 type C2 (40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and as directed.
9
-
-
... More
Supply & fix in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with necessary clamps,bolts etc.or laid in trenches complete all as specified and as directed
20
-
-
... More
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
2.5
-
-
... More
M&L for formwork to faces of walls, retaining wall etc, vertical or batter for rough finished surface complete all as specified and as directed.
80
-
-
... More
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed by the Engr-in-Charge.
15
-
-
... More
Removing excavated materials(soil) to distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
27
-
-
... More
Supply and fix 200mm dia CI pipe complete all as specified and as directed.
10
-
-
... More
Supply and fix 150mm dia CI pipe complete as vent pipe etc complete all as specified and as directed.
5
-
-
... More
S&F CI bends (any type radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch. 'Y' junction, double branch, cross (all socket or socket and spigot) complete all as specified and as directed.
2
-
-
... More
E/M Portion
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, inlcuding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
142
-
-
... More
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and as directed.
16
-
-
... More
Taking down submain wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and as directed.
250
-
-
... More
M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including 25 mm size PVC rigid non matellic casing caping (Double lock) with all casing capping fittings & accessories with 1.60 mm thick pressed steel or mild steel sheet sunk box covered with 3 mm thick backelite sheet fixed with brass screws & cup washers including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and directed.
-
-
-
... More
All as per Sl item No. 80 here-in-above but one light point/ceiling fan/call bell point controlled by one, one way switch.
48
-
-
... More
All as per Sl item No. 80 here-in-above but one 3 pin 5 Amps switch socket outlet point on independent board.
79
-
-
... More
All as per item No. 80 above but for one socket outlet of 15 Amps fixed on independent board with 4 Sqmm multistranded copper conductor wire FRLS PVC insulated and 4 Sqmm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and as directed.
15
-
-
... More
Supply and fix modular switch 1 way 6 A, 1 module 230 Volts, 50 Hz, ISI marked complete all as specified and as directed.
127
-
-
... More
S&F socket 6A-2/3 pin combined 2 module 230 Volts, 50 Hz, ISI marked complete all as specified and as directed.
79
-
-
... More
Supply and fix modular switch 1 way 16 A, 1 module 230 Volts, 50 Hz, ISI marked complete all as specified and as directed.
15
-
-
... More
S&F socket 6A/16A-2/3 pin combined 2 module 230 Volts, 50 Hz, ISI marked complete all as specified and as directed.
15
-
-
... More
S&F in repairs bell push, flush type, 6 amps, 240 volts ISI marked all as specified and directed.
Make : Anchor Product Code No 50075 or equivalent of approved make
6
-
-
... More
S&F in repairs bell ding dong, AC single pole 220/240 volts white/ivory finish, surface type complete all as specified and directed.
Make : Anchor Product Code No 8272 or equivalent of approved make
6
-
-
... More
S&F in repairs ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed
Make : Anchor Product Code No 39040 or equivalent of approved make
8
-
-
... More
Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
24
-
-
... More
S&F in repairs LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed (Make : Havells Cat No LUMLINEPLUSBS20WLED865SPCSS or equivalent of approved make)
8
-
-
... More
Supply & fix white metal hanging light for office complete all as specified and as directed.
5
-
-
... More
S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.vells/ABB/Legrand)
(Make : L&T cat No DBSPN008DD or equivalent of approved make)
16
-
-
... More
S&F in repairs MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge.
(Make : L&T cat No BB20400C to BB20630C or equivalent of approved make)
16
-
-
... More
S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T cat No BB10060C to BB10320C or equivalent of approved make)
96
-
-
... More
M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one run of PVC casing and caping will be measured and paid as one length.)
250
-
-
... More
M & L for earthing in repairs complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and as directed .
2
-
-
... More
Taking down ceiling fan of any type 1200/1400mm from its location and kept in safe custody and refix the same after finishing of ceiling work, painting the fan complete with sysnthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and as directed.
5
-
-