Military Engineer Services Tender

View complete overview of Sikkim MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Sep 2024
Closing Date17 Sep 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for preparation of old surfaces of wall as per srl item No 1.00 here-in-before but two coats of cement base paint over one coat of chalk whiting primer on wall including curing and complete removal of existing treatment complete all as specified and as directed.

300

-

-

... More
All as per Sl Item No 1.00 here-in-before but one coat of acrylic emulsion distemper on wall surfaces complete all as specified and as directed.

4800

-

-

... More
M&L for applying two coats of acrylic emulsion distemper, white or tinted (As approved by GE) including complete removal of existing treatment and preparation of old surfaces even and smooth complete all as specified and as directed.

2000

-

-

... More
M&L for 3mm thick wall care putty on wall surfaces complete all as specified and as directed.

800

-

-

... More
Material and labour for applying two coats of exterior acrylic emulsion painting (weather coat) including complete removal of existing treatment from wall surfaces including scafolding and preparation of old wall surfaces complete all as specified and as directed.

9200

-

-

... More
All as per Sl Item No 8.00 here-in-before but one coat of exterior acrylic emulsion painting (weather coat) on wall old surfaces complete all as specified and as directed.

2000

-

-

... More
M&L for preparation of old painted surfaces of any description over 10cm width or girth of wood and wood based surfaces and applying one coat of synthetic enamel paint (1st grade quality) complete all as specified and as directed.

300

-

-

... More
Material and labour for applying one coat of synthetic enamel paint (1st grade quality) on old painted steel and iron surfaces of any description over 10 cm in width or girth including necessary preparation of surfaces complete all as specified and as directed.

500

-

-

... More
Material and labour for applying one coat of anti-corrosive coptic green paint on old treated roof/wall rusted surfaces of CGI/PGI sheeting of any description and in any position over 10cm width or girth including necessary preparation of surfaces complete all as specified and as directed.

2000

-

-

... More
Material and labour for applying two coats of anti-corrosive coptic green paint on old treated roof/wall rusted surfaces of CGI/PGI sheeting of any description and in any position over 10cm width or girth including necessary removal of old paint & preparation of surfaces complete all as specified and as directed.

372

-

-

... More
Taking down cement mortar plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.

232

-

-

... More
M/L for 15 mm thick rendering with CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement etc complete all as specified and as directed.

80

-

-

... More
M&L for rendering 15mm thick in cement mortar (1:4) in two layers of (10+5mm) each using WPC @ of 3% by weight of cement in finishing layer on brick or concrete surfaces finished even & smooth (WPC for finishing layer will be seperately as supply only).

100

-

-

... More
M&L for rendering 5mm thick in cement mortar (1:3) on brick or concrete surfaces in ceilings, finished even and smooth without using extra cement complete all as specified and directed.

52

-

-

... More
Supply only integral water proofing compound complete all as specified and as directed.

12

-

-

... More
M&L for preparation of newly plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling including comices, pillasters and other wall features complete all as specified and as directed.

52

-

-

... More
E/M Portion: Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed.

85

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed.

83

-

-

... More
Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.

2

-

-

... More
M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 100mm thick complete all as specified and as directed. Note- (i)GI pipe shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables,water supply pipelines,OFC cables etc during the excavation works shall be made good by the contr as per original and GE Cost of the same is deemed to be included to be included in the unit quoted rate.

10

-

-

... More
M&L for 50mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya.

12

-

-

... More
M&L for 80mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya.

6

-

-

... More
Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including relaying in same or different position/location complete all as specified and as directed.

970

-

-

... More
All as per above item No. 26.00 but 95 to 240 qmm complete all as specified and as directed.

330

-

-

... More
Laying,jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floord/roof/ceiling etc of size 2/3/3.5/4 core 16 to 70 sqmm including necessary cable lugs, gland etc complete all as specified and as directed.

150

-

-

... More
Supply & laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated PVC sheathed IS-7098 (Part-I), screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core including cable lugs, glands, insulation tape etc complete all as specified and as directed.

100

-

-

... More
All as per item No 29.00 here-in-above but size of 10 sqmm 4 core

120

-

-

... More
All as per item No 29.00 here-in-above but size of 16 sqmm 2 core

100

-

-

... More
All as per item No 29.00 here-in-above but size of 16 sqmm 4 core

120

-

-

... More
All as per item No 29.00 here-in-above but size of 25 sqmm 4 core

120

-

-

... More
All as per item No 29.00 here-in-above but size of 35 sqmm 4 core

150

-

-

... More
All as per item No 29.00 here-in-above but size of 50 sqmm 3.5 core

100

-

-

... More
All as per item No 29.00 here-in-above but size of 70 sqmm 3.5 core

160

-

-

... More
All as per item No 29.00 here-in-above but size of 95 sqmm 3.5 core

100

-

-

... More
All as per item No 29.00 here-in-above but size of 120 sqmm 3.5 core

150

-

-

... More
M&L for straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10 to16sqmm 3/3.5/4 core cables including testing complete all as specified and as directed.

3

-

-

... More
All as per item No 39.00 here-in-above but size of 25 - 50 sqmm 3/3.5/4 core

3

-

-

... More
All as per item No 39.00 here-in-above but size of 70 - 150 sqmm 3/3.5/4 core

2

-

-

... More
All as per item No 39.00 here-in-above but size of 185 - 300 sqmm 3/3.5/4 core

6

-

-

... More
S&F in repair MCCB 200 Amp,4 pole, 25 KA thermal magnetic based of 50Hz,415 V adjustable type including necessary cable lugs & wire etc complete all as specified and as directed.

2

-

-

... More
All as per item No 43.00 here-in-above but 160 Amps, 4 pole, 25 KA thermal magnetic based

2

-

-

... More
All as per item No 43.00 here-in-above but 100 Amps, 4 pole, 16 KA thermal magnetic based

3

-

-

... More
All as per item No 43.00 here-in-above but 63 Amps, 4 pole, 16 KA, thermal magnetic based

2

-

-

... More
Supply and fix in repair for 300 Sqmm LT UG XLPE aluminium conductor cable wornout/heated/detoriated aluminium lugs including nuts,bolts,washers and PVC tape complete all as specified and as direcred.

80

-

-

... More
All as per item No 47.00 here-in-above but 240 sqmm LT UG XLPE aluminium conductor cable lugs.

80

-

-

... More
All as per item No 47.00 here-in-above but 120 sqmm LT UG XLPE aluminium conductor cable lugs.

60

-

-

... More
All as per item No 47.00 here-in-above but 95 sqmm LT UG XLPE aluminium conductor cable lugs.

50

-

-

... More
All as per item No 47.00 here-in-above but 70 sqmm LT UG XLPE aluminium conductor cable lugs.

65

-

-

... More
All as per item No 47.00 here-in-above but 50 sqmm LT UG XLPE aluminium conductor cable lugs.

55

-

-

... More
All as per item No 47.00 here-in-above but 25 sqmm LT UG XLPE aluminium conductor cable lugs.

50

-

-

... More
M & L for servicing of LT panels/Feeder piller box of any size by complete cleaning of panel and bus bar at chamber with CTC solution, and welding the door using arc welding and fixing of haevy duty hinges/Locking Handles/latches and necessary nut, bolts, washers/Leads/busbar and made it completely functional for open/close and incl checking of incoming and out going cable connections, Re-fixing of existing Cables, ACBs & MCCBs, and repair to connected PCC foundation and frame works, rewiring of control and power wiring of LT panel/Feeder with suitable size of FRLS cable but not less than 1.5 sqmm, replaceing of various unserviciable ON/OFF switches, lugs/Gland/Base plate/indicating Lamp/CT Coil etc making the panel fully functional including numbering the LT panel/feeder box and marking on panels (incoming and locations of outgoing MCCBs), to the satisfaction of Engr-in-Charge complete all as specified and as directed.

10

-

-

... More
M&L for painting of LT panel board of sqmtr not less than 20 sqmtr by spraying two coats of epoxy based weather proof paint of ivory/Red colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.

10

-

-

... More
M&L for painting of LT panel board of sqmtr not less than 10 sqmtr by spraying two coats of epoxy based weather proof paint of ivory/Red colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.

8

-

-

... More
M & L for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25x4mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead/Strip and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC (1:3:6) type C1 for chamber & Pre-cast RCC cover of size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete all as specified and as directed. Note- Rate quoted included the cost of earthwork , GI protection & GI strip from earthpit to LT panel upto 15 mtr.

6

-

-

... More
S & F LED Multifunctional meter with CTs complete all as specified and as directed.

4

-

-

... More
S & F Indication Lamp (LED type) Set of 3 complete all as specified and as directed by Engr in-Charge.

6

-

-

... More
Supply and fix in repair of three phase digital type Ammeter 0-400 Amps, class 1.0 with selector switch complete all as specified and as directed.

5

-

-

... More
Supply and fix in repair of three phase digital type Voltmeter 0-500 Volts, class 1.0 with selector switch complete all as specified and as directed.

5

-

-

... More
Supply and fix in replacement of LT CTs copper wound capacity as per site requirement complete all as specified and as directed.

6

-

-

... More
Supply and fix in repairs isolator of 3 pole of 63 Amps, 25KA 415 volt, complete with connection ,testing and commissioning complete all as specified and as directed.

7

-

-

... More
Supply and fixing 1100 volts grade heavy duty duty 16 sqmm stranded cable PVC insulated aluminium conductor,served with inner sheathing of PVC and overall PVC sheathed in service connections supended by insulating hangers not more than 01 meter apart including 4 mm suspnsion wire one twin core cable flat/circulaor complete all as specified and as directed.

200

-

-

... More
Supply and laying of DWC HDPE pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 50 mm outer dia complete all as specified and as directed by Engr-in-Charge

1500

-

-

... More
Supply and laying of DWC HDPE pipe, ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 75 mm outer dia complete all as specified and as directed by Engr-in-Charge

350

-

-

... More
Supply and fix in repairs MCB of 4 pole of 63 Amps, 25 KA,415 volt complete with connection ,testing and commissioning complete all as specified and as directed.

6

-

-

... More
Supply and fix in repairs isolator of 3 pole of 100 Amps, 25 KA 415 volt, complete with connection ,testing and commissioning complete all as specified and as directed.

5

-

-

... More
Supply and fix in repairs MCB of 2 pole of 63 Amps,25 KA, 240 volt, complete with connection ,testing and commissioning complete all as specified and as directed.

6

-

-

... More
Supply and fix in repairs MCB of 2 pole of 40 Amps,10 KA, 240 volt, complete with connection ,testing and commissioning complete all as specified and as directed.

10

-

-

... More
S&F of street light terminal boxes made out with SMC material, shock & dust proof of inside size 300x200x105mm as per IS and including 20 Amp, TPN busbar fixed on insulators, 01 No 10Amp, SP MCB, earth termination with nuts & bolts and including 02 sets of flat iron 25x6mm clamps of suitable size with nuts, bolts and washers including two coats of aluminium paint over a coat of primer on exposed steel surfaces complete all as specified and as directed.

20

-

-

... More
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation complete all as specifed and as directed.

1.1

-

-

... More
M& L for preparation of old painted surfaaces of street light steel tubular poles above GL/Copping including cross section channels,flat iron clamps by srapping with wire brush applying one coats of aluminium paint including pole numbering using three layer of radium strip of min 4-5 inch wide (Yellow, Green, Blue) on each pole using printer letter complete all as specified and as directed. Note-:(i) Ladders scaffolding,safety belts etc required for execation of works shall be arranged by contractor & cost of the same is deemed to be included in the unit rate quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people enagaged by him & any issues(if any) arising during the work shall be dealt by the contractor& the Dept shall be no way responsibile whatever.

220

-

-

... More
S&F Pathway light 10 watt LED Mount LED Bollard sturdy IP 65 LED bollard with excellent light out put through its PMMA windows ensuring maximum ilumination aspect in surrounding better uniformity etc complete all as speficifed and directed by Engr-in-charge.

12

-

-

... More
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation complete all as specifed and as directed.

1

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanised iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to DBs including necessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and as directed by Engineer-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.