Military Engineer Services Tender
View complete overview of Sikkim MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Feb 2024
Closing Date21 Feb 2024
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_640018_1Bid Award Id
ViewTender No
8207/A/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Description all as per item No. 2.00 above but for 15/16Amp switch socket out let, independent with 2.5 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 2.5 Sqmm for earth continuity conductor, complete all as specified and as directed.
90
-
-
Supply and fixing of switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
140
-
-
Supply and fixing of bell push, 5 Amp, 230Volt, complete all as specified and as directed.
10
-
-
Supply and fixing of bell electric Ding Dong type, AC 230 volts fixed complete all as specified and as directed.
10
-
-
Supply and fixing of ceiling rose, surface Bakelite 65 x 30mm, three terminals, complete all as specified and as directed.
50
-
-
Supply and fix switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, 2 screw with PVC box fix on wall complete all as specified and as directed.
100
-
-
Supply and fix switch socket combination 5 in 1 type, 3 pin 5 / 16Amp, 230 volt, multipurpose, 4 screws with PVC box to fix on wall complete all as specified and as directed.
90
-
-
Supply and fix in repair of switch paino, flush type, single pole, two way, 5/6 Amp, complete all as specified and as directed.
8
-
-
Supply and fix in repair factory made sheet metal enclosure with protected type 2 pin and earth plug socket and socket with one MCB SP 240 volt, 20 Amps complete all as specified and as directed.
5
-
-
Supply and fix in repair 10 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation having THD20% with complete fitting all as specified and as directed.
385
-
-
Supply and fix in repair of 10 Watt LED Bulk Head fitting Environmenatal friendly, ultra morden, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaries comprising of high brightness LEDs complete all as specified and as directed.
30
-
-
Supply and fix in repair of 20 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation having THD20 % with complete fitting all as specified and as directed.
500
-
-
Supply and fix in repair Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and as directed.
20
-
-
Supply and fix in repair of Factory made sheet metal enclosure for DBs single door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s, complete all as specified and as directed.
10
-
-
Supply and fix in repair MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, as complete all as specified and as directed.
70
-
-
Supply and fix in repair MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, as complete all as specified and as directed.
12
-
-
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering, water funnel complete all as specified and testing on completion.
5
-
-
Supply and fix in repair of LED Bldg security light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection with inbuilt surge protector and impact resistance of IK07 complete all as specified and directed by Engineer-in-charge.
45
-
-
Supply and fix in repair LED retrofit lamp B22 holder base with polycarbonate body and aluminium heat sink of 09/10W complete all as specified and as directed.
30
-
-
Supply and fix in repair angle holder for LED bulb of any type complete all as specified and as directed.
100
-
-
Supply and fix in repair LED bulb 9 Watt of any type complete all as specified and as directed.
200
-
-
S&F in repair heating element 2000 Watt capacity, 230 Volts, round / triangle base suitable for existing water heater of 50 litre capacity complete all as specified and as directed.
80
-
-
S&F in repair heating element 1500 Watt capacity, 230 Volts, round / triangle base suitable for existing water heater of 25 litre capacity complete all as specified and as directed.
150
-
-
S& F in repair stainless steel geyser tank of 25 Ltr capacity complete all as specified and as directed.
50
-
-
S& F in repair stainless steel geyser tank of 50 Ltr capacity complete all as specified and as directed.
20
-
-
S&F in repair 15 mm dia PVC flexible connections (pipe) 450mm long with two Nos brass nuts with washer at both ends complete all as specified and as directed.
60
-
-
S&F in repair 15 mm dia bore galvanised iron pipe medium grade with all fittings such as bends, elbow, tees, reducer, diminishing piece, caps, plugs and unions etc. complete all as specified and as directed.
50
-
-
S&F in repair 15mm dia bore stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
100
-
-
S&F in repair of thermostat of capacity 1500 / 2000Watt for geyser of any capacity complete all as specified and as directed.
190
-
-
S&F in repair Solar Water heater 1000 LPD inner tank thickness 3mm for non pressurized with HRCA ceramic coated sheet and outer tank pre coated laminated sheet with mirror finish 50 mm thick PUF (polyurethane foaming) complete all as specified and as directed.
2
-
-
S&F in repair Solar Water heating Tank Mounting Stand suitable for 500 LPD Tank complete all as specified and as directed.
2
-
-
S&F in repair Solar Water heater 500 LPD inner tank thickness 3mm for non pressurized with HRCA ceramic coated sheet and outer tank pre coated laminated sheet with mirror finish 50 mm thick PUF (polyurethane foaming) complete all as specified and as directed.
2
-
-
S&F in repair Solar Water heating Tank Mounting Stand suitable for 500 LPD Tank complete all as specified and as directed.
2
-
-
Supply only distil water bottle of capacity 20 Ltr Capacity for solar water heater batteries complete all as specified and as directed.
30
-
-
Taking down old exhaust fan and overhauling, painting of exhaust fan including oiling and greasing of exhaust fan complete including replacement of damaged screw of blade and body and refixing to exhaust fan and testing complete size of exhaust fan 250 / 300 mm sweep complete all as specified and as directed.
70
-
-
Taking down all parts of old exhaust fan and takinfg out old brunt copper winding of motor and rewinding with super quality super enamelled copper wire of existing gauge including testing complete of following size of fan :-
-
-
-
Exhaust fan 250 mm
20
-
-
Exhaust fan 300 mm
40
-
-
S & F in repair capacitor of capacity 4 Mfd, 50 Hz complete all as specified and as directed.
50
-
-
M& L for servicing including carrying out preventive maintenance of package type AC plant 5.5 TR capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed. cleaning of the condenser , evaporator, fins, chiller unit and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as specified and as directed.
3
-
-
M&L for gas charging with refrigerant gas suitable for package type AC capacity of 5.5 TR of any make, model and taking down leak testing upto 24 hrs and to achieve desired suction pressure and temperature complete all as per specified and directed.
2
-
-
Supply & fix in repair of LP/HP combination cut out suitable for R-22 gas complete all as specified and directed
2
-
-
Supply and fix in repair expansion valve for 5.5 TR condensor complete all as specified and as directed.
2
-
-
Supply and fix in repair PCB of ductable type air cooled split AC 5.5TR complete all as specified and as directed.
2
-
-
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz indoor and outdoor unit of split air conditioners 2.00 Ton capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. cleaning of the condenser , evaporator, fins and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC in good working condition complete all as directed by Engineer-in-Charge. Note :- (i) Spares part required will be measured and paid separately under respective item of this schedule. However for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz screws, washers, teflon seal, rubber bush, insulating tape, copper thimble, copper connecting jack, short length connecting wire, etc are deem to be included in the quoted rate.
2
-
-
All as per item No 46.00 above but for 1.50 Ton Capacity complete all as specified and as directed.
2
-
-
All as per item No 46.00 above but for 2 body deep freezer capacity 2 TR complete all as specified and as directed.
2
-
-
All as per item No 46.00 above but for Refrigerator capacity 180 Ltrs complete all as specified and as directed.
2
-
-
All as per item No 46.00 above but for Deepfreezer capacity 190 Ltrs complete all as specified and as directed.
2
-
-
Taking out unserviceable Compressor of 2.00 Ton capacity AC from site and replacement of compressor with new one to match the existing make/model R of compressor and fixing of new sealed unit in position, charging required quantity of refrigerant gas as per existing design of AC, brazing of discharge and suction line including leak testing after vacuum testing and repair to the system including testing on load complete all as specified and as directed.
Make :- Kirloskar/ Hitachi/ Copeland/ Danfoss Note :- Cost of copper capillary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
1
-
-
All as per item No 51.00 above but for 1.50 Ton Capacity complete all as specified and as directed.
2
-
-
All as per item No 51.00 above but for deep freezer 2 TR as per site requirement complete all as specified and as directed.
3
-
-
All as per item No 51.00 above but for Refrigerator upto 210 Ltr as per site requirement complete all as specified and as directed.
3
-
-
M&L for gas charging with refrigerant gas R-22/43 suitable for Split AC upto 2 Ton capacity of any make, model and capacity, and taking down leak testing upto 24 hrs and to achieve desired suction pressure and temperature complete all as per specified and directed.
3
-
-
All as per Ser Item No 55.00 above but for water cooler upto 60/120 Ltr of any type and capacity as per site requirement as described complete all as specified and as directed by Engineer-in-Charge.
2
-
-
All as per Ser Item No. 55.00 above but for refrigerator/Deep freezer upto 2 Ton of any type and capacity as per site requirement below all as directed by Engineer-in-Charge.
3
-
-
All as per Ser Item No. 55.00 above 2 body freezer upto 2 Ton of any type and capacity as described below all as directed by Engineer-in-Charge.
2
-
-
Supply only of PCB for split AC capacity 1.5/2 Ton capacity complete all as specified and directed.
2
-
-
Supply only starting capacitor 80 to 100 MFD suitable for Split type AC 1.5 / 2.0 Ton/Deepfreezer/Refrigerator of any make complete all as specified and as directed.
3
-
-
Supply only running capacitor 36 MFD suitable for split type A C 1.5/2.0 Ton/Deepfreezer/Refrigerato complete all as specified and as directed.
3
-
-
M&L for cleaning, servicing including carrying out preventive maintenance of Central AC plant 1X 22 TR capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed. cleaning of the condenser , evaporator, fins, chiller unit and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as specified and as directed by Engineer-in-Charge
3
-
-
Supply only Heating Coil 3 KW for 1x22 TR AC Plant complete all as specified and as directed.
6
-
-
Supply only R-22 Gas complete all as specified and as directed by Engr-in-charge.
10
-
-
Supply only Nitrogen gas cylinder and leakage testing complete all as specified and as directed.
3
-
-
Supply only expension valve of Central AC plant 1X 22 TR capacity complete all as specified and as directed.
3
-
-
S&F in repairs MCB TP 32A complete all as specified and as directed Make:- L&T Cat no - LK30320K or its equivalent in Siemens, Legrand L&T.
2
-
-
S&F in repairs Power contactor AC operational current upto 415V and 9Amp complete all as specified and as directed.
Make:- Siemens Cat no - 3RT1023-1A or its equivalent in ABB, L&T
2
-
-
S&F in repairs temperature controller of SubZero Cat No - 7510T of Danfoss complete all as specified and as directed.
2
-
-
S&F in repairs 3 Pole power contactor MNX12 AC operational current upto 415V complete all as specified and as directed.
Make:- L&T Cat no - CS94108/CS94109 or its equivalent in ABB, Siemens.
2
-
-
S&F in repairs 3 Pole power contactor MNX9 AC operational current upto 415V complete all as specified and as directed.
Make:- L&T Cat no - CS94106/CS94107 or its equivalent in ABB, Siemens.
2
-
-
S&F in repairs MN coil suitable for MNX Contactor 24-30A, 415V complete all as specified and as directed.
Make:- L&T Cat no - SS94145OOFO or its equivalent in ABB, Siemens.
3
-
-
S&F in repairs single phase preventor complete all as specified and as directed.
Make:-L&T Cat no - ST92166OOOO & CS94824COOO or its equivalent in ABB, Siemens.
2
-
-
S&F in repairs electronic timer complete all as specified and as directed.
Make:- L&T Cat no - ST80328OOOO or its equivalent in ABB, Siemens.
2
-
-
S&F in repair VAF + PF multifunction meter suitable for 415 Volt with CT's complete all as specified and as directed.
Make:- L&T Cat no - WL411021OOOO or its equivalent in ABB, Siemens.
2
-
-
S&F in Voltage monitoring relay 3 phase, 3 wire complete all as specified and as directed.
Make :- Siemens of Cat no - 7UG0818-1AA20 or its equivalent in ABB, L&T, Siemens.
1
-
-
S&F in Temperature controlling relay 110-240V AC phase, complete all as specified and as directed.
Make:- Siemens of Cat no - 7UG0480-1IU20 or its equivalent in ABB, L&T Siemens.
1
-
-
Supply and fix in water drier size 5/8" complete all as specified and as directed.
Make:- Danfoss or its equivalent in L&T, ABB
2
-
-
Supply & Fix in replacement of mini plate Hepa Filter of size(610X610X75) mm(WXHXD) of existing make and model at 178 MH (ICU & OT) with following specification. (i) Frame-Aliminium Extruded sections(Non Anodized)
(ii) Type of Filter-Flanged Type
(iii) Media- Micro fibre Glass(Imported) media protected with Al mesh
(iv) Sealing of Media-By Means of Epoxy
(v) Efficiency-Above 99.975 down to0.3 micron particle
(vi) I.P.D.-- 16+10% mm WG
(vii) F.P.D.-50 mm WG
(viii) Separators-Hotmelt Glue
(ix) Filter face velocity-125FPM
(x) Operating Temp- Normal atmospheric Temperature
(xi) Air flow direction-cassettle to flange
22
-
-
Supply and fix in replacement of PRE Filters EU4(washable Tpye) of size(610X610X50)mm (WXDXH) of existing make and model at 178 MH(ICU& OT) with following specifiction. (i) frame- Aliminium Extruded sections(Non- Anodized)
(ii) Type of filter-Box type
(iii) Media- Non Woven Synthetic media supported by Al mesh on one side& finished with HDPE mesh on the other side.
(iv) sealing of media-By means of Epoxy
(v) I.P.D.- 5mm WG
(vi) F.P,D.-15mm WG
(vii) No of folders-11 Nos/RFT of filteration
4
-
-
M&L for cleaning, servicing including carrying out preventive maintenance of 3 phase 415 volt 50 Hz inverter outdoor variable flow refrigerent type (22+22+14) 58 HP capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed. cleaning of the scroll compressor,condenser , evaporator, fins, and cooling coils shall be done using blower/ vacuum cleaner and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as directed by Engineer-in-Charge.
Note:-
(i) During period of contract any fault/defects obtained also shall be rectified and also included quoted rate
(ii) spare parts shall be measured and paid under respective items.
1
-
-
Supply only fan board PCB complete all as specified and as directed.
3
-
-
Supply only main board PCB complete all as specified and as directed.
2
-
-
Supply only BLDC motor complete all as specified and as directed.
3
-
-
Supply only drive board complete all as specified and as directed.
2
-
-
Supply only noise filter complete all as specified and as directed.
2
-
-
Supply only R-410a Gas all as directed by Engr-in-charge
30
-
-
M&L for cleaning, servicing including carrying out preventive maintenance of single phase 230 volt volt 50 Hz inverter indoor(ductable) Variable flow refrigerent typecleaning of the coil ,filter, fan of following capacity using suitable cleaning solution, tools and minor spares viz screws, washers, insulation tapes etc. as per site requirement and as directed and replacement of unserviceable spares and insuring its serviceability by keeping the AC plant in good working condition complete all as specified.
Note:-
(i) During period of contract any fault/defects obtained also shall be rectified and also included quoted rate
(ii) spare parts shall be measured and paid respective items.
-
-
-
2.0 TR capacity
9
-
-
2.5 TR capacity
6
-
-
8.0 TR capacity
2
-
-
1.7 TR capacity
2
-
-
Supply only Cordless display for indoor units for VRF Acs complete all as specified and as directed.
2
-
-
Supply and fix in replacement of 3 pole power contractor of MNX 50 Amps complete all as specified and directed.
1
-
-
M&L for pumping down the gas of the split ACs capacity 1.5/2.0 TR pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying and sealing the leakage by gas welding/ brazing pressure, completely vaccuming the system and re-charging the system with R133a or R 407 gas or as mentioned in the split ACs capacity 1.5/2.0 TR system, testing and commissioning all as specified and as directed.
2
-
-
M&L for pumping down the gas of the package type AC plant of 5.5 Ton capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying and sealing the leakage by gas welding/ brazing pressure, completely vaccuming the system and re-charging the system with R133a or R 407 gas or as mentioned in the AC plant system, testing and commissioning all as specified and as directed.
1
-
-
M&L for pumping down the gas of the Central AC plant of various capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying and sealing the leakage by gas welding/ brazing pressure, completely vaccuming the system and re-charging the system with R133a or R 407 gas or as mentioned in the AC plant system, testing and commissioning all as specified and as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements