Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 17,330Document Cost
₹ 1,180Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_RRVPN_238288_14Bid Award Id
ViewTender No
NIT04(2021-22)Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
E060600 . Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thick Distribution board as per PWD specification for electrical
Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar,
shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with
detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All
as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR E060622 6 Way ( 18 O/G + 8 I/C )
1
-
1917
E231900 Supply & fabrication steel structure with MS channel / angle / joist / ISMB /
sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer
& two coat of enamel paint etc. as required complete in all respect. All as per
pre approved by Engineer in charge. For additional technical parameters of
products/ work , refer Annexure "A" attached with this BSR .
100
-
89
E110200. Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated
earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity 99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I
(b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E110215 10.0 Sq. mm E110215C 4 core
40
-
372
E222600 Providing & Fixing of ISI marked (IS : 4985 - 2000) Hard rigid PVC 25mm drain water piping with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge .For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
110
-
136
E222300 Supply , Installation, Testing and Comissioning of Interconnecting refrigerant copper pipe for split of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Material Test Certificate required with each supplied material. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
110
-
1166
E222400 Supply & fixing of external thermal closed cell elastomeric nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal nductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 in form of tubular sulation between each set of indoor & outdoor units as per specificationsnitrile including cost of adhesive complete as per specification and as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR (a) .E222413 6mm thick insulation and 13 mm internal Dia
125
-
27
(b) E222415 6mm thick insulation and 19 mm internal Dia
125
-
33
E080100 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:-
(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure
(b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar
and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.
(d) only outer area on all sides shall be measured & panel to be
fabricated only from CPRI approved fabricator. All as per drawing pre
approved by Engineer in charge. For additional technical parameters of
products/ work , refer Annexure "A" attached with this BSR .
3
-
3443
E060100 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity notless than 10KA (B/C tripping characteristic as per type of load and site requirement) 4KV impulse with stand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) / conforming to IEC 60898-12002, IEC 60947-2 , low watt losses, trip freem echanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq. mm., conduct or line load reversibility, label holding facility, IP20 contact protection and fitted with existing distribution board / sheets, min. operation 20,000 upto 32 A rating and 10,000 up to 63A ,5000 for 80A ratingin cluding making connections, testingetc. asrequired. .OEM shall have submit NABL / CPRI / ERD Aaccredia ted lab test reports before execution & All as perprea pproved by Engineer in charge. For additional technical parameters of products / work, refer Annexure "A" attached with this BSR . (a) E060140 Four pole MCB E060144 50-63 A rating
4
-
1265
E060400 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short - circuit and earth leakage protection as per PWD specification for electrical Works with ISI marked (IS12640-2) / conforming to IEC 61009 -1 , breaking capacity 10KA , true position indication and trip free mechanisum, line load reversibility, provision for padlock, min. operation 10,000 upto 63A rating and 5000 for 80A -100A rating, minimum phase termination capacity of 35sq. mm. , IP20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI/ERDA accrediated lab test reports before execution & All as per pre approved by Engineer incharge. For additional technical parameters of products / work, refer Annexure "A" attached with this BSR .E060430 Four pole 30 mA sensitivity E060433 63 A rating
3
-
3108
E090500
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flam eretardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50Hz ; O/L & S/C setting sa sper PWD specification for electrical Works , conforming to IS/IEC 60947 P-2:2003 with front face and central is edadjustable, trip free mechanisum, true contact position indicator, line load inter change ability, designed for both horizontal & vertical mounting with out any adverse effect one lectrical performance, suitable for operation upto 55degree and with out derating upto 40 degree, pollution degree3, having positive isolation capability, push (test) to trip, trip time less then 10 msunders /ccondition, Breaking capacity Ics = 100 % Icu . Uimp = 8 KV , rated insulation voltage 800V, provision for UVR, shunttrip, earth fault trip, door inter lock, padlock & rotary handle, including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediat edlab type test certificate before execution. All as per preapproved by Engineer incharge. For additional technicalparamet ersof products / work, refer Annexure "A" attached with this BSR .
up to E090512 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu Gr.1
1
-
7029
E080700 Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works, ISI marked as per IS2705-1992 / conforming to IEC60044-1, with secondary terminal of CT shall be brought out suitabl etoaterminal block which shall be easier accessible for testing and terminal connection, with all necessary supportin existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required. All as per preap proved by Engineer incharge. For additional technical parameters of products / work, refer Annexure "A" attached with this BSR .E080701
C T Class 1, Ratio upto 150/5, Burden 5 VA
3
-
355
E120400 Supplying and making end termination with heavy Copper / Bimetallic lugs Pin / ring type (IS8337-1976) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc of following size. All as per pre approved by Engineer incharge. For additional technical parameters of products / work, refer Annexure "A" attached with this BSR .E120405 10.0 Sq.mm
80
-
9
E081100 Providing & Fixing of IP51 Multifunction meter as per PWD specification for electrical Works, ISI marked (IS16444) / Confirming to IEC61557 & IEC 62052 with LCD/LED 3/4 line display capable of measuring electrical parameters like V,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarh display with 1A/5A CT input for LV/HV network, with / without RS485 communicatio nport etc. OEMM usthave BIS certificate and & shall have submit NABL/CPRI/ERDA lab test reports be fore execution & complete in all respect. All as per preapproved by Engineer incharge. For additional technical parameters of products / work , refer Annexure "A" attached with this BSR .E081102
Multifunction LCD meter with V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh, Run hours, On hours, Phase angle, Interrupts, THD, Events, Neutral Current class 1 accuracy with RS485 port.
1
-
7223
E140600
Supply & Laying following size earth strip in horizontal or vertical runing round / surface / recessin cluding riveting, soldering, saddles, Jointing shall be done by over lapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products / work , refer Annexure "A" attached with this BSR .E140604
30mm x 5 mm copper strip
2
-
962
E081000 Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .E081001 Red/yellow/Green colour
3
-
127
E140700 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E140702 8 SWG copper Wire
20
-
81
E110100 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E110138 70.0 Sq. mm E110138A 3.5 core
40
-
320
E307100. All in all comprehensive maintenance of Variable Refregarent Volume (VRV) air conditioning system including indoor units, outdoor units, cordless control, refregarent piping , control cables, Remote control, drain piping, consumables, LT panel etc complete in all respect as per OEM guideline to meet out the maximum efficiency of machine after defect liabality period. (Total HP For Three Year 40 X 3= 120 HP i.e 120 X 0.825 = 99 Ton)
99
-
2532