If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

North Western Railway - NWR Tender

Works
Ireps
+1Tonk, Rajasthan
Opening Date10 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 76,13,08,465.49 
Notes
Download

Costs

Summary

Design, Manufacture, Supply, Installation, Testing And Commissioning Of Microprocessor Based Electronic Interlocking (ei) System In "hot Stand By Mode"at

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of the following essential spares to the extant of 10% of the quantities 4 installed(subject to minimum 1 number):-(i) Each type of Input/output cards(ii) Each type of vendor specific relays(iii) DC-DC converters of all voltages (iv) Switches, connectors, fuses, couplers. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after Supply.

2

5353953

9765611.49

... More
Supply of work station note book as per Technical Specifications . It also includes supply 5 of Laser Printer (Only branded). The workstation should be capable of reconfiguring the system in case of any alteration in yard interlocking in future. Technical Specifications should be attached with the tender document by Tendering authority. Inspection: Consignee Inspection charges: None Payment terms: 100% after supply

5

86892

396230.85

... More
Supply of Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations . (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, 6 spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose pliers etc. & measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at site). Each set comprises of the following :- * Crimping tool for all types of special cable assembly used in EI system. * Insertion tool for all types of special cable assembly used in EI system. *Removal tool for all types of special cable assembly used in EI system. * Digital multimeter (Fluke 111 or better) * Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485 mm depth (Godrej Make/Jalaram) of good quality to store tool, spare cards and documents. * Steel Book rack Size: 1850mm height, 900 mm width and 316 mm depth for keeping documents. (Godrej Make/Jalaram) * Clamp Earth Tester.(as per specs mentioned in tender document.) * Clamp Current Meter (fluke 362 or superior) Inspection: Consignee Inspection charges: None Payment terms: 100% after supply

4

125748

458731.15

... More
Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system. (Hard copies of training material/ course modules to be given to each participant). Inspection: Consignee Inspection charges: None Payment terms: 100% after execution

120

1106

121065.81

... More
Design, preparation & supply of drawings in computer print copies and original tracing 8 in AUTO CAD FORMAT for Electronic Interlocking at each station. After completion of the work, the completion drawings incorporating completion details are to be supplied as per Technical Specifications given in tender document (upto 6 Line). The techinical specifications are as per ANNEXURE 1.13 of SOR. Inspection: Consignee Inspection charges: None Payment terms: 100% after execution

12

175967

1925786.68

... More
Training of Officers for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system.(Hard copies of training material/ course modules to be given to each participant). Inspection: Consignee Inspection charges: None Payment terms: 100% after execution

40

1097

40023.3

... More
Supply of embedded fanless PC based VDU control terminal as per RDSO spec. No. 10 RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 . The size of VDU shall be minimum 42 inch. Note: (i) Technical requirements shall be mentioned in the tender document. (ii) One revolving chair should be supplied with control terminal. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply.

20

409839

7475467.01

... More
Installation, wiring, testing and commissioning of embedded fanless PC based VDU 11 control terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 . Note: (i) Technical requirements shall be mentioned in the tender document by tendering authority. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning.

20

102459

1868866.75

... More
Supply of embedded fanless PC based Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 . The 12 size of VDU shall be minimum 42 inch. Note: (i) Technical requirements shall be mentioned in the tender document by tendering authority. (ii) One table of suitable size alongwith revolving chair should be supplied with Maintenance terminal. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply

8

385774

2814610.31

... More
Installation, wiring, testing and commissioning of embedded fanless PC based 13 Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 . Note: (i) Technical requirements shall be mentioned in the tender document. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning.

8

96443

703652.58

... More
Preparation of SWR literature in english alongwith associated mid-section interlocked gate with all corrections as per approved SWRD & approved SIP. For this all technical corrections, 14 editing, grammatical correction etc. are to be carried out and one rough print to be given to railways for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.

13

3598

42665.24

... More
Translation of Station Working Rules from english to hindi and framing out in DIGLOT 15 form (or similar software )as per extant Rly practice. The required SWR in english will be provided by the contractor and has been covered separately in item no. 1.21 of Chapter 1 of this SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. 01012300 130.00 Set 178.52 23207.60 (-) 8.80 21165.33

13

4478

53093.3

... More
Making photocopies & binding of the SWR literature in English/hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.

-

-

16

... More
Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spec.No.IRS/S- 76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include 17 bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases(G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning.

1100

-

8.8

... More
Supply of maintainer's furniture of godrej make or superior and each set consist of(i) 18 executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no .(iii) visitor chair seat & back cushion with high density foam with plastic pvc handle capsule type painted back-03 nos. Inspection: Consignee Inspection charges: None Payment terms:100% after supply.

10

22986

209640.35

... More
Supply of Micro Processor based Data Logger System with 1280 digital and 32 analog inputs as per RDSO Spec. No. IRS (S) 99/2006 or latest with laser printer 22 ppm (Only branded HP/Brother/Canon). It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring 19 arrangement & monitoring of DG sets, ELD , IPS, UFSBI, BI ,interlinking and networking of Data logger. It also includes supply of leased line MODEM , suitable online UPS (minmum 6 hours backup) and other interfacing cards, if required for networking of Data Logger.This also includes supply of one no. composite computer and printer table (Godrej work station table or similar) for keeping processor module and one number Godrej operator chair Model PCH7001 or similar. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply

10

485984

4432182.11

... More
Installation, wiring, testing & commissioning of Micro Processor based Data Logger System with 1280/ 4096 digital and 32 analog inputs as per RDSO Spec. No. IRS (S) 99/2006 or latest It cover complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & DG sets,ELD , IPS,UFSBI, BI interlinking and networking of Data logger. All material required for wiring, networking, power supply monitoring, door-locking arrangement etc will be supplied by contractor.. Note: Total numbers of relays and other signalling 20 functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines. Networking of data logger includes extraction of data report from test room. For networking, required communication channel(Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC Porta Cabin and it will be extended by contractor upto location of data logger by using CAT-5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre- Commissioning checklist (circulated by RDSO) with the OEM representative. Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning

10

121496

1108045.53

... More
Supply of Failure Analysis & Fault Diagnostic software for data logger upto 4096 digital inputs at a station. Inspection: Consignee, Inspection charges: None Payment terms:100% after supply.

10

39122

356796.47

... More
Installation and commissioning of Failure Analysis & Fault Diagnostic software for data logger upto 4096 digital inputs. Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning

10

9780

89199.07

... More
Supply of Failure Analysis System (FAS) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The 23 Specification of FAS shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge.(Technical specification shall be provided in tender documents.) Inspection: Consignee Inspection charges: Borne by Railways Payment terms:100% after supply

10

163959

1495309.45

... More
Installation, testing and commissioning of Failure Analysis System (FAS) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge 24 before supply. Note: The Specification of FAS shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge.(Technical specification shall be provided in tender documents.) Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning

10

40989

373827.34

... More
Supply of 750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make of Emerson/APC or superior as per Engineer in-charge. Inspection: Consignee, Inspection charges: None Payment terms:100 % after supply.

10

26250

239400

... More
Supply of Sealing wire used for sealing of signaling relays & equipments. Inspection authority:- Consignee Inspection charges:-None Payment Terms:- 100% after supply.

6

175

959.08

... More
Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be 27 of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

2

5813

10603.39

... More
Supply of 1 x 6 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 84 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 28 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply

1100

36

36486.38

... More
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 29 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

1100

57

57714.1

... More
Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 127 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 30 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply

1100

99

99768.24

... More
Supply of 1 x 25 Sqmm (Red/Black) multi strand copper power wire as per IS:694:2010 or latest, 197 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 31 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

1100

155

155786.93

... More
Supply of 1 x 35 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 277 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 32 76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

1100

176

177496.18

... More
Supply of wiring material in relay room for potential free relay contacts for digital & analog Inputs (1280 digital inputs and 32 analog inputs). It includes supply of PVC insulated indoor Railway Signalling cable (1/0.6 sqmm dia), 60-Core/40-Core/Single Core as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest, PVC insulated jumper wires multi strand, tinned in all colours as per RDSO Specn.No. IRS: S-76/89 (Amnd.3) or latest. The item also includes supply & wiring of Modular 33 disconnect terminals /Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751 or latest. The wiring for getting potential free contacts of relays for complete PI/RRI/EI installation including points, tracks, signals, panel, power supply, IPS, SSDAC,TLBI,LC Gates, crank handle control etc will be done by contractor. All material will be supplied by contractor except the relays. The Relays will be supplied by Railway. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Installation & commissioning

12

38132

417318.25

... More
Supply of Powder Coated Relay Racks as per Drg.No.CSTE/ NWR/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be supplied & completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200-Way tag 34 blocks with poly carbonate covers, grouting bolts, tripods etc. It includes supply of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

20

46394

846227.29

... More
Erection of Powder Coated Relay Racks as per Drg.No.CSTE/ NWR/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200-Way tag 35 blocks with poly carbonate covers, grouting bolts, tripods etc. It includes fixing of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. After installation of relay racks, one coat of paint will be done by contractor before fixing the fuses. Scaffolding should include 1 relay rack position as spare at every Station/ Level Crossing Gate for future expansion. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on execution

20

11598

211556.82

... More
Supply of Cable Termination(CT) racks as per Drg.No.CSTE/NWR/ SOR/02 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw 36 less terminals/ ARA terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be Powder Coated. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply

47

22732

974402.02

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 37 scaffolding and suitable grouting arrangements with installation of 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on NWR & the instruction of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on commissioning.

47

8687

372364.71

... More
Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg.No. SA-23741A(Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply.

94000

87

7493484.48

... More
Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply.

3000

152

418553.28

... More
Supply of indicating type fuse inserts with holder (material will be supplied only from approved vendors of RDSO). Inspection: Consignee Inspection Charges: Borne by Railways. Payment Terms: 100% on supply.

-

-

103026.82

... More
Supply of indicating type fuse inserts without holder (material will be supplied only from approved vendors of RDSO). Inspection: Consignee Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. 04011900 3000.00 Numbers 54.64 163920.00 (-) 8.80 149495.04 42 42

-

-

35066.4

... More
Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. 04012900 200.00 Numbers 50.08 10016.00 (-) 8.80 9134.59 46

-

-

2224385.33

... More
Installation, Wiring and testing of Integrated Power Supply System. This includes power 52 distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of Thermo flasher relay, ELD's, fixing & wiring of change over switch (program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc.Any masonry work required will be carried out by contactors own material. It includes transportation of IPS from consignee depot to work site/station/ LC gate. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution 05012400 19.00 Numbers 122346.29 2324579.51 (-) 8.80 2120016.51 53

-

-

1338157.89

... More
Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply.

-

-

3494528.64

... More
Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups 55 & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. 05015700 15.00 Numbers 2390.64 35859.60 (-) 8.80 32703.96 56

-

-

514032.02

... More
Supply of Tools Kit for High frequency Digital Axle Counter Multi section 07012500 12.00 Set 862518.19 10350218.28 (-) 8.80 9439399.07

-

-

526877.57

... More
Erection of CLS Post with base and signal unit on top or on OFFset Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own 86 brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after commissioning. 08010900 81.00 Numbers 26768.11 2168216.91 (-) 8.80 1977413.82

-

-

628199.04

... More
Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding 147 Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. 11010900 520.00 Numbers 9563.45 4972994.00 (-) 8.80 4535370.53

-

-

5152126.4

... More
Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location 150 box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. 11011300 102000.00 Numbers 12.52 1277040.00 (-) 8.80 1164660.48

-

-

1561791.56

... More
Supply of Rapid Joint LS3, suitable for cable Jonting of Signalling cable of various size, 155 having dielectric strength > 20KV/mm, Non Toxic, low viscosity, Flamability point > 200 C, Re-entrable, Long storage life Make RAYTECH or Similar. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. 12010200 2300.00 Metre 760.66 1749518.00 (-) 8.80 1595560.42

-

-

162438.73

... More
Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee 12010700 3000.00 Numbers 1798.20 5394600.00 (-) 8.80 4919875.20

-

-

327006.72

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever 208 required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways.NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). Inspection:Consignee Inspection Charges: None Payment Terms: 100% after Execution 14011100 10.00 Numbers 5145.23 51452.30 (-) 8.80 46924.50 209

-

-

271201.94

... More
Design, Manufacture & Supply of Electronic Interlocking (EI) System (with centralized arrangement) for 5 Line (Five line) Durgapura (DPA) stations with 1 OC as per Signal Interlocking Plan in 'Hot Standby architecture'. EI system shall be provided to operate with dual VDU Control Terminal as per RDSO Specification No.RDSO/SPN/ 192/2019 Ver. 2 or latest and from RDSO approved source only. It mainly consist of Microprocessor Equipments, Interface Equipments, EI vendor specific Interfacing Relays , In-built event Logger, In-built Power Supply Equipments, Racks (Only Relay Rack/EI Rack), 1 Indoor cables, Wires, Fuses , Fixtures, Mounting arrangements along with all accessories required to make complete EI system functional. Design of indoor EI system should be compatible as per outdoor interlocking requirement based on Signal Interlocking Plan & Selection Table of station/yard. This item also includes supply of following :- (a) Supply of documents/manuals for EI system as per RDSO Specn.No. RDSO/SPN/192/2019 Ver. 2 or latest. (b) Supply & provision of protective devices like surge and lightning protection devices compatible to RE standards as recommended by OEM / RDSO. c) Supply of as made document as per tender condition and specfication. Note: It includes supply of all the material which is required to make complete EI system to be functional and as recommended by RDSO in Specn.No.RDSO/SPN/192/2019 Ver. 2 or latest. Design , manufacture & Suupply of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time.The Technical Requirements are attached with the tender document. Railway will supply RDSO approved type of relays with approved contact configruation only . I n case of requirement of vendor specific relays/relays with non-RDSO approved contact configruation being supplied, the same shall be supplied by the tenderer and cost of required relays shall be included in the cost of EI (Electronic Interlocking) system and number & type of such relays shall be indicated separately. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply

1

24341939

24341939

... More
Addition, alternation and wiring in existing of Design, Manufacture & Supply of Medha make Electronic Interlocking (EI) System (with centralized arrangement) with I/O gathers for Jaipur (JP) station with 1OC as per Signal Interlocking Plan in 'Hot Standby architecture'. EI system shall be provided to operate with dual VDU Control Terminal as per RDSO Specification No.RDSO/SPN/ 192/2019 Ver. 2 or latest and from RDSO approved source only. It mainly consist of Microprocessor Equipments, Interface Equipments, EI vendor specific Interfacing Relays , In-built event Logger, In-built Power Supply Equipments, Racks (Only Relay Rack/EI Rack), Indoor cables, Wires, Fuses , Fixtures, Mounting arrangements along with all accessories required to make complete EI system functional. Design of indoor EI system should be compatible as per outdoor interlocking requirement based on Signal Interlocking Plan & Selection Table of station/yard. This item also includes supply of following :-- (a) 2 Supply of EI Cards & module, wires, cable and other material etc required for alteration. (a) Supply of documents/manuals for EI system as per RDSO Specn.No. RDSO/SPN/192/2019 Ver. 2 or latest. (b) Supply & provision of protective devices like surge and lightning protection devices compatible to RE standards as recommended by OEM / RDSO. Note: It includes supply of all the material which is required to make complete EI system to be functional and as recommended by RDSO in Specn.No.RDSO/SPN/192/2019 Ver. 2 or latest. Design , manufacture & Supply of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time.The Technical Requirements are attached with the tender document. Railway will supply RDSO approved type of relays with approved contact configruation only . In case of requirement of vendor specific relays/relays with non-RDSO approved contact configruation being supplied, the same shall be supplied by the tenderer and cost of required relays shall be included in the cost of EI (Electronic Interlocking) system and number & type of such relays shall be indicated separately. Inspection: RDSO Inspection charges: Borne by Railways Per

1

21617590

21617590

... More
Design, Manufacture and Supply of Electronic Interlocking System (Hot Standby) ) equipments asper RDSO specification no. RDSO /SPN/192/2019 Ver 2.0 with latest amendments (I/O gatherer or object controller OC , CIU (if required) ) for mid section Relay Huts/Goomties for Auto- Signalling EI working in conjunction and in tandem with Auto E.I. being provided at Stations in North Western Relay Room/End Goomties etc. (item wise break up cost and details to be supplied with unit, rate, quantity and brief description of their function should be listed by tenderer in Annexure). Rate for supply of essential spares to be quoted separately (item wise details to be supplied with unit, rate, quantity and brief description of their function should be listed by tenderer in (ANNEXURE-"F" as enclosed below ) which consists circuits packs/ boards/terminals, power supply equipments, cards, ancilliary equipments, interconnecting cables/couplers/ connectors of each type which may be lowest level field replacable module/ assembly/ device. Itemwise details of essential spare minimum @ 10% of the quantities used in the equipment subject to minimum of one to be supplied as stipulated in the Para 10 of Special Condition of Contract of EI system at above station. Inspection: by RDSO.However, items not covered under RDSO inspection, will be inspected by the representative of CSTE/C/NWR as per RDSO acceptance test format. Drawing to be submitted in this cost - Supply of completion Drawing and Documents for approval, Technician/ Jr. Engg at installation and maintenance level - Manual for installation, testing,commissioning and maintenance of the system. 6 sets for each E.I. Supply of completion Drawing and Documents: c) Supply of completion drawing and documents: Completion documents- 6 Sets for each EI Station. Inspection: Representative of CSTE/C/NWR. The Input/output of Auto E.I. and other related informations shall be send/received to other adjacent Auto EI or Existing E.I. to take corresponding inputs/outputs wherever required for Indications/Interlocking processing purposes. or Esixitng E.I. to take corresponding Inputs/outputs wherever required for Indications/Interlocking processing purposes. Note:-- Unit of 1 Nos Auto Goomty will be treated as One(01) Nos "Station

-

-

3

... More
Supply ,installation, wiring, testing and commissioning of embedded fanless PC based VDU control terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - 4 STS/E/TAN/3007 version 1 dated:02.11.12 . The size of VDU shall be minimum 55 inch. Note: (i) Technical requiements shall be mentioned in the tender document. (ii) One revolving chair should be supplied with control terminal. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply.

10

479960

4799605.4

... More
Supply ,installation, wiring, testing and commissioning of embedded fanless PC based Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - 5 STS/E/TAN/3007 version 1 dated:02.11.12 . The size of VDU shall be minimum 55 inch. Note: (i) Technical requiements shall be mentioned in the tender document by tendering authority. (ii) One table of suitable size alongwith revolving chair should be supplied with Maintenance terminal. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply

5

462157

2310788.85

... More
Change over switch 200 Amp. 3 Phase, 415VAC, 50Hz (Side Handle) four pole, Make Havels IHCFFE 200 or superior. Inspection: Consignee Inspection Charges:None

9

9995

89963.01

... More
Supply of 2.5 Sqmm (Red/Black) Multistrand copper wire for Track feed Charger and battery. Inspection: Consignee Inspection Charges:None

4000

26

105680

... More
Supply of Edge PC for Data receiving and routing to the central processing and storage system at Zonal HQ and Central cloud as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest

10

282341

2823416.7

... More
Supply of station Gateway equipment to receive the data from various IoT devices at field , relay room, equipment room as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest. Note: Necessary Public IP and its recurring charges should be borne by the railway.

15

183840

2757605.4

... More
Supply of IoT device for various S&T gears and transmit the data to the station gateway system as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest.

550

72724

39998546.5

... More
Supply of IoT device for sensing 110 V DC Battery Bank parameters and transmit the data to the station gateway system as per FRS Document No. RDSO/ RDPM/FRS/2021 dated 06.05.2021 or latest.

15

184576

2768650.5

... More
Supply of voice modem at station gateway to connect field IoT device to the station gateway via copper cable.

35

26262

919201.85

... More
Supply of Dual serial to EI converter card to connect station gateway to Central systemat Zonal HQ.

15

43809

657140.4

... More
Supply of led indication system with indication, buzzer and acknowledgment button up 14 to 6 line station with interface facility to existing data logger and modification of Data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train. Inspection by RITES.

10

59514

595149.9

... More
Supply of Microprocessor based interface for SSDAC/HASDAC/MSDAC to monitor upto 8 ports of DAC reset boxes in SM / Relay Room as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest.

20

147012

2940252.6

... More
Data Logger System and alternation work in the existing Data logger at Jaipur with 1OC for Doubling with Auto signalling work

1

64250

64250.23

... More
Supply of Data logger with 512 digital inputs and 32 Analog inputs as per RDSO spec No. IRS:S:99/2006 (Amendt.3) or latest. (Inspection RDSO) 18

4

269747

1078991.76

... More
Supply of Cartridge fuse PPTC.

500

129

64945

... More
Supply of Dual RS232 to E1 converter card suitable to Insert in the data logger euro 19 rack for Interlinking Data loggers installed at various stations on JP-SWM section on jp division One no required per Data logger ,that converts Voice to E1 channel at Stations,24 for FEP in control room) (Inspection by RITES)

10

31256

312565.9

... More
Supply of Dual channel serial optical fibre Media converter(data logger to Data logger NETWORKING VIA DUAL PATH )(Inspection by Consignee)

10

31613

316138.1

... More
Supply of Data concentrator (Additional T port connectivity in between existing rings (Inspection by consignee) 22

6

120561

723366.9

... More
Supply of Protocol converter (Inspection Consignee)

10

37315

373151.3

... More
Rubber hand gloves suitable for 1500 Volts.ISI marked tested certificate to IS: 4770- 1968-91 as per IS:13774-1993. make commander/ similar.

30

476

14285.7

... More
Tool kit for signal maintenance with following items (with small size canwas log) (i) Insulated combination plier of 8" = 1no. (ii) Insulated long nose plier of (road wise) 6" =1 no. ( iii) 24 Insulated wise stroper plier of 6"=1 no ( iv) Insulated screw driver set(5 piece) =1 set (v) Side cutting plier 6" =1 no (vi) Hex with frawise 12"= 1 no (vii) Double end spanner set (6 to 32mm) = 1 set (viii) Adjustable spanner set 8" =1 no (ix) Ball pin hammer 200 gm =1 no (x)Soldering iron 25 watt =1 no ( xi)Torch cell LED (3 cell) everady/jeep = 1no (xii) Auto ranging digital multimeter (Branded) =1 no (xiii) Crow bar steel/ tommy bar =1 no

6

4676

28058.94

... More
Supply & Installation of Solar Distilled water plant capable to produce minimum 50 Liter distle water per day complete assembly containing following components. (a) Interconnection & different valves for connection inlete, outlete tank, internal distribution system. Pipe should be 3/4" astrial make, incl. supply of pipe and accessories like valves, elbow, Tsocket joint etc. (min requirement 25 25 Mtrs approx). (b) Water pump 1 HP workable on 230 V AC with all accssories like 15 AMP plug, socket & cord etc. Same water pump will be unlisted for pumping water to inlete tank & recharging the resin cation / nion column by providing interconnection valves, sockets etc. (c) Water storage tank of 50 liter capacity, 02 nos of reputed make like Sintex for storing of inlet and outlet water by suitable pipe fitting. (d) Campers of 12 liter capacity-05 Nos. (e) Testing Kit or connectivity meter for online checking of the quality of water. Inspection: Consignee Inspection charges: None

4

66749

266996

... More
Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.

500

609

304955

... More
Supply of Multi section digital axle counter complete set with all accessories consisting 27 of complete indoor and outdoor equipment including including reset box, and monitoring console as per RDSO specification no.RDSO/SPN/176/2013 (ver. 3) with latest ammendmend/revision of required track section. It includes transportation to SSE depot and from SSE depot to site.Inspection by RDSO (1 Number = 1 DP).Note: 1. If any housing is required to keep outdoor equipment, it has to be supplied with the equipment with no extra cost. 2. Maintenance free earthing (supply and installation) for track device/mushroom housing to be done by the contractor if required by system design. No separate payment will be made. 3. Automatic resetting will be provided by providing soft supervisory track section as per scheme plan. All hardware software for auto resetting to be provided by the contractor. 4. All other hardware like extra cards modem etcs required for commissioning will be supplied by the contractor. Separate Evaluator to be provided for up and Dn line as well as at station or RH as decided by the site engineer. ABS scheme will be as per letter no. SG/42/NWR/HQ/Vol VII dtd. 31.05.2022

550

349776

192376926.5

... More
Supply of DC to DC Converter, 24-32 V/5Amp as per RDSO spec no. RDSO/SPN/165/2012 or latest

15

19098

286472.4

... More
Supply of DC to DC Converter, 24-32 V/10Amp as per RDSO spec no. RDSO/SPN/165/2012 or latest 30

15

19628

294429.9

... More
Supply of 1KVA inverter module as per RDSO spec no. RDSO/SPN/165/2012 or latest 31

1

66623

66623.91

... More
Supply of 1KVA transformer module as per RDSO spec no. RDSO/SPN/165/2012 or latest

1

14897

14897.62

... More
Supply of HDPE pipe 4"/110mm for HDD crossing as per IS Spicification 4984: 2016 or latest

11000

404

4450820

... More
Supply of insulation mate, rubber mate for electrical purpose 2.5mm thick size 2m x1m suitable for 3.3KV to 11KV (class-B) confirming to IS 15652-2006. 34

200

1644

328982

... More
Supply of Smoke Detector Tester, Aerol 9980,117g 35

40

1078

43159.6

... More
Supply of Heat Gun (2000W)

10

2958

29582.4

... More
Supply of modular power supply arrangement for VDU (42" to 85") andembedded PC (As specified in NWR HQPolicy letter No. SG/184/1-Vol.VII dtd01.03.24) with input and outputredundancy arrangement and hot plug-able modules having voltage & loadcurrent digital display on each module.Each set consisting of: - 1.Isolatedinverters (master/slave with autochangeover) -2 Nos. input: 110VDC,output: 110 VAC, 500VA (as per RDSO TAN No. STS/E/TAN/3012 Version 3.0Dated.03.11.22) 2.Isolated DC-DCconverters - 02 Nos. connected inparallel with built in O-ring 36 diode,active current sharing as perRDSO/SPN/165/2023 version 4.0 orlatest (input: 110VDC, output:24VDC/10A) 3.Input (redundancy) O-ringdiode module with two input sourcesand one output supply along withpotential free contacts, alarm andacknowledgment switch. 4. 3Ustainless steel rack with back panelmother board and front panel powerconnectors, power cord for VDU panel.Technical detail is mentioned inAnnexure-TS-1(B). Make-Gallant/Phoenix/APC or better.Inspection: RITES, Inspection charges:Borne by Railways, Paymentterms:100% after supply(Item is alsoplanned to be use at midsection LCgates (where IPS is not provided) toproduce the 110V AC for road usersignal and 24 V for gate circuits fromcommon 110 V DC input extendedfrom nearest IPS.)

32

163135

5220320

... More
Supply and printing of PVC ferrules in various colours as per colour coding of S&T policy of the cable termination (5 cm in length) for CTR/Location box and junction box suitable for Railway S&T cables. 38

205000

5

1053700

... More
Printing of vinyl board with lamination

870

1829

1591543.2

... More
Supply of Multi section digital axle counter GGTronics (MSDAC-G39 Version 00) For Jaipur station as per annexure.( Per DP)

8

271400

2171200

... More
Supply of way station control equipment as per RDSO specification No. RDSO/SPN/TC/66/2007 with amendement-2, including latest amendment with necessary mounting arrangment on composite rack or wall as decided by site engineer. It shall be 48V DC operated provide to give connect to atleast 4 stations telephone and have a facility to give more connections by using 3 way amplifier. Inspection: RDSO Inspection charges: Borne by Railways

-

-

41

... More
Supply of push button telephone Pulse/Tone switchable telephone set with redial, mute, pause, flash tone, pulse facility as per TEC spec No. GR/TEL-02/04 Sept 02 with amendment 2, including latest amendment. Inspection: Consignee Inspection Charges:None

40

1622

64911.2

... More
Push Button CLI Phone, Handfree Make Beetel or superiar. Inspection: Consignee Inspection Charges:None

40

796

31840.4

... More
Supply, Transportation & Testing of VHF based secured communication equipment consisting of microcontriller based equipment with built in Voice/Data storage facilites. 25 W VHF radio 44 with talking instrument, power supply (12V DC/15Amp) sealed maintenance free battery bank 12V/120AH, Omni directional stacked dipole antena, 50 mtr length RG-217 cable, inclding portable programing and data back up terminal . Make -AE Telelink as per RDSO specfication no. RDSO/SPN/TC/73/2008 with latest amenments.( VHF set should be digital or as per latest Rly Bd. guidlines)

10

351334

3513349.5

... More
Supply of 24 port Layer3 network switches with 4 Nos. 10/100/ 1000 Base-T/1000 Base- X SFP ports make model DG-GS4628HPSE2 DIGISOL /CISCO/JUNIPER or superior. Inspection: Consignee

10

117460

1174600.8

... More
Supply of PVC Conduit pipes 25 mm dia.ISI marked MS Series as per IS-9537 Part-III - 1983 Sta standered or latest inspection by Consignee

3000

20

62760

... More
Supply of RJ-45 Cat-6 Patch chord /LAN Cable length 1 mtr. Make of D- link,Amp/Tyco,DAX,Legrand,Molax or Similaror superior

100

191

19118

... More
Supply of maintanance tool kit as per technical specification as per Annexure 1.)Digital multimeter4 1/2 digit with liquid cristal display o1 no. Fluke-287 or similar/Motwani/stenley (ii) Utility Knife-01 no.(iii) Cable slitter-1 no. (iv) Tubing cutter for cable armour-1 no.(v) Bare fiber adaptor -01 no. (vi) Miller heigh precision stripper for fiber buffer-1 No. (vii) Cleaver Fujikura make or similar-1 no. (viii) 48 Mechnicial splice joint set,01 set consiting of 6 nos. (ix) ceramic scissor CSI -01 NO. (x) FC/PC Adopter with ODB Loss 10 no.(xi) Optical fiber terminal block v groove-02 nos. (xii) Earth resistance measuring instrument with all accessories suitable for measuring earth resistance in range of 0.1 ohms to 10 ohms-01 no. (xiii) Megger-01 no.(xiv) laser distance meter PRO-L100-02 No.(xv) supply of digital multimeter 3 3/4 digit liquid crystal display type (Stenly or motwane or similar) ( xvi) supply of LPG Blow lamp -02 no. (for use in copper cable jointing) (xvii) supply of medium hammer set with chiesel set with covered holder inspection by consingee

2

186906

373812.92

... More
Supply of standered 19"rack mountable LER ,IP-MPLS Router with redundant -48 VDC 49 Power supply ,2x 10 G SFP + Port along with 2 Nos of 10 G SFP +MODULE(40 Kms),4x 1Gbe optical interface with 04 no. of 1Gbe SFP (10 Kms) module,4x iGbe copper WAN based interface and 16x E1 (G.703) Interface module ,with upgrade option as per Sn.B Item 3 of RDSO Document no: STT/TAN/IP- MPLS/2020 Version 1.0 or latest (inspection by RDSO)

5

281826

1409130.4

... More
Supply of 16 port Channelised E-1 Interface card (including 120 ohms cable) suitable for the IP -MPLS router for Sr no. Inspection by RDSO

4

78875

315503.68

... More
Supply of 8x 10 Gbps WDM Interface module card or channelized STM-1/4 Card suitable for the above as per the site requirement and as instruction by site incharge inspection by RDSO.

2

83526

167053.46

... More
Supply of 8 port X1G E4FE/4 FX module card suitable for the IPMPLS Router for Sr.no. 38 inspection by RDSO

5

31909

159545.45

... More
Supply of 4 port x 10G SFP Mdule card suitable for IPMPLS Router for Sr.no.38 inspection by RDSO

5

27216

136082.9

... More
Supply of GSM 4G FCT Phone with 4G Connectivity ( Fixed cellular phone) with built in battery and extendable battery charger .make:- Binatone or similar or latest Accepted make:- beetal modal F03-4G inspected by Consignee

12

5020

60241.92

... More
Supply of indoor PA counter communication system Ahuja CCS-2300/Herman/ Bosch/ similar or superior

12

9800

117603.36

... More
Supply, installation, testing, wiring& commissioning of router havingports WAN ports04 Nos. of10/100/1000 MBBase T EthernetPorts, 04 Nos of1000 MB SFP Slotand 4 nos. ofE1 port along 56 withdual powersupply along with allassociatedacessories, power cable,Consolcable mannualsMountinghardware etc.. Router alsomustequiped with 4 XcompatibleSFP 1.25 GBPS SingleModeDual fibeer 20Km.PreferredMake/Model TechroutesTSR-2900-40 or equivalentmodelwith same specificationinJuniper, HP make. Inspection byConsignee

10

205049

2050491.2

... More
Supply of Network wire crimper,Cable Stripper, Crystal HeadCutter,Cable Stripping Plier,Crimping toolfor CAT-5,CAT-6, CAT-7 ComputerNetwork CrystalHead(Black). Make:Thenki or D- Link, AMP/Tyco/Digisol or similar.Inspection by Consignee.

2

3330

6660.62

... More
Supply of WI-FI Acess point Indoor -Indoor AP With directional/omni directional antenna including mounting kit along with controller in 1+1/N+1 Redundancy/or cloud based controller .(CISCO or Cambium or Superior) . (Inspection Agency Consignee.

20

17685

353703.8

... More
Supply of Central Data Controller (CDC) unitswith central Data Switch(CDS) along with allsoftware vide spec no:-RDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection :RDSOInspection charges :Borne by Railway, Payment Terms : 100%after supply

1

522844

522844.29

... More
Supply of Single line double faced TrainArrival/Departure DisplayBoards as per RDSO Spn.No.RDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection: RDSOInspection charges: BorneBy Railways Paymentterms: 100% after supply

12

130711

1568532.84

... More
Supply of Platform Data Controller spe no. as perRDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection RDSO.Inspection charges: Borneby railways Paymentterms: 100% after supply

6

27636

165816.36

... More
Supply of Armoured Outdoor CAT-6 cable(305 mtrs Roll) of make -D- Link/Pollycab/Digisol/Finolex (Box-Roll of 305 Mtrs.) (Inspection by consignee)

10

21270

212701.8

... More
Supply of True colour Outdoor Video Display (OVD) size Pixel Resolution(WxL) 432x128 as per RDSO specfication no. RDSO/SPN/TC/108/2019 Rev.0.0 with amendment -1 or latest Inspection by RDSO

2

1980000

3960000

... More
Supply of 48V Managed media converter(Ethernet/E1 to Optical) as per RDSO spec No.RDSO/SPN/TC/103, Rev 2.0 or latest and as perdetails given below for SCADA working. Itssupply includes three tributary slots & oneoptical module supporting distance of 20 Kmswith (1+1) protection on optical interface (onedual core & one single core), 2E1 ports and four 100Mbps ETH interface through Optical interfaceand built in DSL modem to work on quad orcopper (2W) up to five kms with 65 auto changeover feature between DSL line (2W) & Opticalinterfaces and three tributary slots loaded withone four port E&M interface supporting 2W/4Wconfigurable for TPC / EC provision; onetributary slot loaded with ETH modulesupporting RSTP feature for connecting RTU andone tributary module support four port two wirevoice for connecting hotline & Auto phone (2port each (FXO & FXS). Unit to be standardtelecom rack mountable and supplied with rackmounting kit / Unit to have E1 tributary modulesupporting two E1 as option for converting E1 toETH for RTU purpose at SSP/SP/TSS locations.Type of Media convertor- option3, Mediaconvertor- without POE, patch cord cable- notrequired, SFP- should support 20KMS distance.

10

266935

2669359.1

... More
Supply of 110V Managed media converter(Ethernet/E1 to Optical) as per RDSO spec No.RDSO/SPN/TC/103, Rev 2.0 or latest and as perdetails given below for SCADA working. Itssupply includes three tributary slots & oneoptical module supporting distance of 20 Kmswith (1+1) protection on optical interface (onedual core & one single core) , 2E1 ports and four100Mbps ETH interface through Optical interfaceand built in DSL modem to work on quad orcopper (2W) up to five kms with auto changeover feature between DSL line (2W) & Opticalinterfaces and three tributary slots loaded withone four port E&M interface supporting 2W/4Wconfigurable for TPC / EC provision ; onetributary slot loaded with ETH modulesupporting RSTP feature for connecting RTU andone tributary module support four port two wirevoice for connecting hotline & Auto phone ( 2port each (FXO & FXS ). Unit to be standardtelecom rack mountable and supplied with rackmounting kit / Unit to have E1 tributary modulesupporting two E1 as option for converting E1 toETH for RTU purpose at SSP/SP/TSS locations.Type of Media convertor- option3, Mediaconvertor- without POE, patch cord cable- notrequired, SFP should support 20KMS distance.

10

243896

2438962.9

... More
Supply of Two Port E1 module which can beaccommodated in the Managed media converterto convert E1 to ETH for SCADA purpose similar.

10

20273

202735

... More
Supply of Pathfinder High Pow er Pipe and Cable locating kit (Bluetooth enabled to transfer data to Mobile App) with DA2 GNSS RTK receiver, with RTX performance based on Catalyst Correction service for upto 2cms horizontal / 5cms vertical accuracy & Mobile App for data acquisition of GNSS coordinates of route traced and depth data and digital map generation, including cloud data backup & map output in .kml, AutoCAD, .csv . Pathfinder PLDL receiver with 36 user configurable Active multi frequency options including 200Hz, 512Hz, 797Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 200kHz upto 476.2kHz, passive detection @ 50Hz for pow er cables, Radio Mode for locating metallic utilities whether energised or not, Live Current measurement, LCD Display with left-right arrow 68 function , Modes: peak, peak with arrow , pin point peak and null modes, Compass function; Live Depth measurement. Supply includes locating Bluetooth enabled Pathfinder PLDL receiver, Transmitter (Max pow er : 12Watt with high pow er output >= 130Volts) with Li-ion Rechargeable Batteries for both Transmitter & Receiver, Battery charger, GNSS receiver with pre-configured RTX Catalyst correction service for accuracy as mentioned above(w ith 3 years license), Dual bluetooth mobile phone with pre- loaded Mobile App & cloud access for real time map generation (with 5 years license). Make/Model : Rycom Pathfinder PLDL Cable Route Locator with Trimble DA2 GNSS Receiver(Detailed Specifications as per Annexure I). Pathfinder PLDL Pipe Cable route tracer with GNSS receiv er & auto correction serv ice upto 5cms accuracy, Mobile app for generating maps, and dual bluetooth mobile phone Model No:10194600+DA2+C1+TF+A23

1

1250345

1250345

... More
Supply of the following essential spares to the extant of 10% of main Equipment/Module for EI System) of the input Cards/ Modules as speccified by OEM For Durgapura station Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after Supply

1

2719100

2719100

... More
Supply of professional LED VDU monitor of display size 55 inch. 4K UHD, Resolution 70 3840x2160(UHD),Refresh Rate-60 hz,HDR_HDR 10 Pro-yes,HDR_HLG-Yes,Audio out-10w+10w ,Processor-@ 5Gen6 AL Prosser 4K,Magic remote compatibility-Yes,Air play-yes,,wifi-yes,Universa Remote setting-yes,HDMI in-03 no.,RF in-01,USB-02 No,RJ-45-01 No.Make:- SONY,LG,Samsung or superior

10

68627

686270.8

... More
Supply and installation of Earth Electrode including MS flate for Signalling Equipments as lever frames, appratus cases, signal, Relay Rack, Block Instrument etc. (Supply and fixing of each earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post and other equipment as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35 mm x 6 mm and fixing of lead M.S. flat to earth electrode and lever frame, signal post and apparatus cases as per drg. no. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/ S&T/ Sig / Tender /SK/13/85 Alt.-'A'.) Inspection: Consignee Inspection charges: None

-

-

2

... More
Supply, installation,wiring, testing and commissioning of Magneto Telephone in ASM office, locations, Relay Room, Point location, siding point control location , LC gates or at any other location as per instructions issued by site engineer incharge . Contractor has to supply magneto telephone as per RDSO Specn.No.IRS:TC-79/2000 (Amnd.2) or latest.

50

110780

110780.5

... More
Shifting and installation of Apparatus Cases on CC foundation on grouted bolts. The item includes fitting of E Type locks and fabrication of slotted angle frame and fixing it inside location box. Railway will supply only location boxes. Apparatus Case Single (Full)

20

2424

48497.6

... More
Shifting and installation of Apparatus Cases on CC foundation on grouted bolts. The item includes fitting of E Type locks and fabrication of slotted angle frame and fixing it inside location box. Railway will supply only location boxes. Apparatus Case (Half)

15

1599

23992.35

... More
Supply and fixing of teakwood planks 25 mm thick duly varnished for keeping batteries, 6 power supply equipment etc. Required size (i.e. length & breadth) will be decided by Engineer at site as per requirement. This item also includes supply and fixing of material like nuts, bolts, screws, nails etc.

7

56164

393150.03

... More
Modification/Alteration of existing DC track circuits covering points zones also.The item includes provision of doubled continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2mm dia, skimming of fish plate, insertion of insulated block joint if required, fixing of TLJB (separate for positive & negative rails) with angle iron for track feed/jumper/track relay ends of track 8 circuits and also for fixing jumper cables as per approved Track Circuit Plan, making rail connections through suitable insulated sleeves from TLJB at TF, jumper & TR end with GI wire, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on TLJB terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins, Hooks etc. Inspection: Consignee Inspection charges: None

80

3469

277557.6

... More
Provision of fully furnished Camp office at site for SSE/JE for keeping documents, drawing, tool etc and supervision of work.

48

17443

837297.6

... More
Testing and commissioning of Data logger with 512 digital inputs and 32 Analog inputs as per RDSO Spec No: IRS:S:99/2006 (Amendt.3) or latest

4

22479

89916

... More
Shifting of existing colour light signal with foundation along the track to meet the schedule of dimension required in connection with RE modification

10

26860

268600

... More
Configuration and mapping of gear wise signaling information in remote diagnostic software, testing and Commissioning as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest

704

1067

751660.8

... More
Installation, testing & commissioning of IoT Devices as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest.

704

5323

3747497.6

... More
Installation, testing & commissioning of IoT Devices for IPS Battery Bank as per FRS Document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest

20

26615

532315

... More
Installation of Gateway at station as per FRS document No. RDSO/RDPM/FRS/2021 dated 06.05.2021 or latest.

20

43698

873978.4

... More
MTC Networking Software with HASP 18

10

331063

3310634.5

... More
MTC Networking design, Installation, testing & commissioning 19

10

224789

2247899.6

... More
Communication Device to suit railway STM availability/OFC Communication 20

10

168538

1685385.2

... More
Ethemet LAN Cable-CAT 5e/6e (Coils of 90 Mtr) 21

10

12415

124156

... More
DC-DC Converter (230V/24V) Inspection Agency:-Consignee 22

5

52964

264820.55

... More
Monthely Basis Cab & Taxi Hiring Services- MUV:- 2500 Km 23

-

2728704

2728704.6

... More
Extra per KM charge

72000

7

524160

... More
Supply, Fabrication, Installation and Fixing of panel operator console with arrangement to fix upto 55" VDUs- 02 nos, reset boxes and other S&T gadgets, This shall be made of not less than 24 18mm thick plywood/ novapan of better material (as per requirement of Railways) with storage facility of approved colours with contreators material, lead, lift and manpower as per instructions of engineer incharge and as per enclosed drawing, Modification in size & layout is permissible as per site & room requirement. Finishing work to be done as per instruction of engineer incharge. Inspection:- Consignee 25

10

268670

2686707.1

... More
Installation, Testing and commissioning of Data concentrator

5

13502

67513.8

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately) Inspection: ConsigneeInspection Charges: None.Payment Terms: 100% after Execution.

500

19

9730

... More
Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) Complete set with all accessories Consisting of complete indoor and outdoor equipment including reset box and monitoring console as per RDSO Specification No. RDSO/SPN/176/2013 (ver. 3) with latest 28 ammendmend/revision of required track section. It includes transportation to SSE depot and from SSE depot to site (1 Number = 1 DP). Note: It includes supply of HDPE pipe for laying of transmitter and receiver cable, digging of trench under track upto location/mushroom housing. All other accessories required for commissioning will be provided by the contractor. ABS scheme will be as per letter no. SG/42/NWR/HQ/Vol VII dtd. 31.05.2022

550

12213

6717337

... More
Re-designing of EI program, testing and commissioning in connction with Phase work of Double line.

4

554462

2217851.72

... More
Testing and commissioning of led indication system with indication, buzzer and 30 acknowledgment button up to 6 line station with interface facility to existing data logger and modification of Data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train. Inspection by Consignee.

3

7638

22916.55

... More
Supply and transportation of self lubricated HDPE pipe of 50 mm inner dia and 63 mm outer dia .

3000

160

481170

... More
Installation, Wiring,Testing and Commissioning of modular powersupply arrangement for VDU (42" to85") as per RDSO TAN No.STS/E/TAN/3012 Version 3.0Dated.03.11.22 item includes supplyand fixing of suitable mountingarrangement.Inspection: Consignee,Inspection charges: None ,Paymentterms:100% after commissioning.

32

18644

596608

... More
Fixing of Electrical high thrust (220mm) point machine on the extended sleepers at thick web point as per section of rails used. Item included fixing of switch extension bracket, fixing of switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting of the point machine with crank handle. The item also includes (i) Complete material for installation of point machine and fixing of ground connection/ switches extension bracket like point insulator 33 materials, S pipe, wiring materials various fixing nuts & bolts including casting nuts, spring washers, etc. (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate. (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine & junction box/ cable hut as per extent practice of WCR and the instruction of railway Engineer at site. (v) supply and fixing of suitable size GI pipes with flange for taking cable into point machine, Electrical point machine, ground connection and M6 Screw less terminals will be supplied by Railways, covered in schedule seperately.

130

21002

2730262.6

... More
Installation, Wiring, Testing and commissioning of way station station control equipment as per RDSO specification No. RDSO/SPN/TC/66/2007 with amendement-2, including latest amendment with necessary mounting arrangment on composite rack or wall as decided by site engineer. It shall be 34 48V DC operated provide to give connect to atleast 4 stations telephone and have a facility to give more connections by using 3 way amplifier.(Installation, Wiring, Testing and commissioning of way side equipments on the rack or wall as per station wise. (This includes supply of all materials for execution of work except way side equipment which will be procured by Railway against other item. ) Inspection: Consignee Inspection charges: None

20

18443

368862.8

... More
Installation of push button telephone Pulse/Tone switchable telephone set with redial, 35 mute, pause, flash tone, pulse facility as per TEC spec No. GR/TEL-02/04 Sept 02 with amendment 2, including latest amendment.(Installation of DTMF/way side telephone in all stations or advice by site engineer. This includes supply and fixing of DP, PVC channel, telephone bracket and laying/termination of switch board cable.) Inspection: Consignee Inspection charges: None

50

405

20284.5

... More
Supply ,installation ,Testing & Commissioning of 4K UHD Bullet type IP Camera along 36 with the mount .all the accessories and fixing material including mount required for this installation are to be supplied by contractor within the same cost as per RDSO SPEC. NO. RDSO/SPN/TC/65/2021/Version 6.0 or latest.

25

40171

1004281

... More
Supply installation ,testing, wiring and commissioning of Full HD Resolution large format display LED Monitor Screen size 55" (inch) or large as per RDSO specification no.RDSO/SPN/TC/65/2021/Version 6.0 or latest.

5

46673

233369.9

... More
Supply and Installation Surveliance Hard Disc of survillance harddisk drive of 6 TB Capicity with 64 MB cach and SATA 6 Gb/s interface for DVR/NVR Of standered make like WD or superior 6TB. Inspection: Consignee Inspection charges: Nil

20

16955

339107.8

... More
Supply, Installation, Testing & commissioning of 32 Channel NVR with 4K Support and 4HDD 32 IP Channel input ; HDMI,I/I Audio I/O and 2/I Alarm I/O; 12 MP,8 MP,5MP,3MP,2MP,1080 P,DI & CIF Recording Resolution ; 5x4K/16X 3MP/24X1080P/54X720 64XD1 Decoding ; 4 SATA HDD Support 39 (10 TB Capacity per slot,Hard disk not include); save storage space with adaptive recordinng & camera wise recording retention ; SMS & Email notification /calling from mobile application ; 512 mbps throughput-256 uplink,256 Down link cascading : built in CMS to monitor manage multiple NVRS; ONVIF and major camera brand support Slot64 IP Channel Inputs: Inspection: Consignee Inspection charges: Nil

5

49941

249706.15

... More
Supply,installation,testing and commissioning of modem E-1G 703 and V-35 as per RDSO Specification RDSO/SPN/TC/80/2008,Rev.0.0 or latest,of Dax Networks/signus make or similar or reputed make.

14

14219

199069.08

... More
Fixing of PVC Conduit pipes 25 mm dia with all required fixing accessories (such as bends,metal clamp,fixture etc as per instruction by consignee.

3000

7

22110

... More
Laying of OFC/Power cable/CAT-6 cable through HDPE pipe/casing caping/fall ceiling with laying/fixing of HDPE pipe/casing caping for IP Based video surveillance system and for connecting/interfacing various components and system integration. All materials for jointing and termination of power cable/CAT-6 cable as per site requirement are to be supplied by contractor. This item also include supply of RJ-45 connector with cap for terminating CAT-6 cable and supply and installation of power board with 4 points (3 nos 5 amp sockets and 1 nos 50 amp socket )as per site requirement.

24000

21

521040

... More
Installation,Testing,and commissioning of 8/ 24 port layer-3/Layer-2 switch Payment Term-100% after execution

20

4563

91263.8

... More
Installation of IP MPLS Router and switches,with power distribution panel and all accessories in the rack 19 inch 42 u,DDF ,Aluminium runway ladder,patch chord etc.and their testing 44 and commissioning.this include all E1s on DDF,Connection of pigtails,optical patch chord and 48 volt equipments confirming with the approved system design including end to end testing for realization of optical fiber system.this also include supply of all as made document for the entire section (six copies)plus technical maintanance and installation manual for IP MPLS ,NMS ,Charger and power supply unit with OEM Certificate.per station

5

22148

110743.35

... More
Training of railway staff and officers at the factory premises/Rly site of manufactureer of IP MPLS Document or at a reputed training instition as approved by railway executive incharge. (travel expenses will be born by the railway)

10

16611

166114.9

... More
Writing work of cable termination details of 6 Quad,OFC,PIJF Cables and Equipment details at OFC Room/Cable hut and station building and wherever necessary as per direction of engineer in charge per station.

10

1319

13195.4

... More
Supply, preparation, splicing and installation of straight joint for 48 fibers along with enclosures with heat shrinkable splice protection sleeve as per TEC No. TEC/GR/TX/FTP-01/03/May- 2010 or latest. Splice losses in no case should be more than 0.1 dB.

30

11466

343988.1

... More
Supply, installation and complete wiring of Optical fiber cable termination box for 48 fibers complete with base housing, base mountings with fixing arrangement etc & splicing of fibers with low loss of pigtail cables as per detailed specification mentioned in respective tender documents. Two pairs of fibers shall be derived from either side of OFC cable at every OFC cable hut provided at 48 wayside stations through pigtails with SC/APC connectors and remaining fibers on either side will be made through by splicing. At OFC terminal stations/MW repeater stations, all fibers shall be derived from either side and to be terminated in OFC termination box through pig tails and SC/APC connector. The OFC termination box to be supplied as per TEC No. TEC/GR/TX/FTP-01/03/May-2010 or latest. Splice losses in no case should be more than 0.1 dB. Necessary 0 dB connectors should be provided by contractor in OFC termination box. This items includes patch chord as per site requirement.

28

21906

613378.92

... More
Installation &commissioning of CentralData Controller (CDC)units with central 49 DataSwitch (CDS) along withall software vide spec no:-RDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection :Consignee Inspection charges: NonePayment terms: 100%after execution

1

8216

8216.13

... More
Installation & commissioning of Single line double faced TrainArrival/Departure 50 Displayboard. This includes allrequired accessoriesrequired includinghanging structure forfixing arrangements tocommissioning the item.RDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection: ConsigneeInspection charges: NonePayment terms: 100%after execution

12

10038

120463.32

... More
Installation &commissioning of Double Faced Coach Guidance Display Boards in 51 shadearea This includes allrequired accessoriesrequired includinghanging structure forfixing arrangements tocommissioning the itemas perRDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection: ConsigneeInspection charges: NonePayment terms: 100%after execution

40

2987

119507.6

... More
Installation &commissioning of Double Faced Coach Guidance Display Boards in 52 openarea This includes allrequired accessories including hanging structure, pole and fixingarrangements tocommissioning the item.Rain hood/sun guardshould be provided inopen area for displayboards as perRDSO/SPN/TC/108/2019Ver 1.0 or latest withlatest Amendment.Inspection: Consignee

78

5975

466078.08

... More
Cutting of the platform surface (Tile/Slab)for adepth of 25cm and awidth of 54 10cmsandrefilling/Reconditioning/Concerting/Repairing theplatform after laying HDPE pipe and cable.Cutting should be donewith marble cuttingmachine in proper mannerand restore the same asbefore in such a mannerthat aesthetic of theplatform is not disturbed.Inspection: ConsigneeInspection charges: NonePayment terms: 100%after execution

1500

165

248670

... More
Installation of PA system at Rly station as per instruction of Railway site Engineer Incharge, the requred cable , conduct,Amplifire and equipment shall be supplied by Rly. Cable shall be laid in proper conduict.

10

4427

44278

... More
Installation, testing and commissioning of True colour Outdoor Video Display (OVD) size Pixel Resolution(WxL) 432x128 as per RDSO specfication no. RDSO/SPN/TC/108/2019 Rev.0.0 with amendment -1 or latest Inspection by RDSO

2

44000

88000

... More
Supply, installation , testing and commissioning of Train information At a glance display board with all accesseries as per RDSO specfication no. RDSO/SPN/TC/108//2019 Rev.0.0 with amedt.1 or latest (ispection by RDSO) 58

7

227865

1595057.66

... More
Submission of detailed placement plan for Telecom item

10

17600

176000

... More
Installation and commissioning of WI-FI Acess point on pole/structure/roof/platform and marking of access point with all material ,manpower and machine arrange by contractor .

17

399

6798.64

... More
Per route kilometer price offer for S&T cable route locating by Geo-Tagging route in trench for metallic signalling or telecom cable, with GNSS coordinates acquired generally with upto 5 10 cms location accuracy (inaccuracy upto 40 cms range permitted for locations with tree cover etc, final accuracy depending on weather & interference conditions), with depth of cable in trench based on ground level at that location to be indicated. 1. Data Output should be mapped provided on .kml format with integrated depth data of cables mapped. Equipment utilised will be cable route locator with GNNS RTK receiver mounted on equipment. 2. Equipment utilised should be cable route locator with >=120V &>=12Watts transmitter power using low frequencies of 200Hz , 640Hz, 1kHz & RTK mounted directly on equipment with RTX Correction service for upto 5cms accuracy, with Utility mapping 60 software used on mobile phone (Mobile phone with Utility mapper software should take data via bluetooth from both Cable locator & RTK GNSS receiver , with Auto correction Catalyst service simultaneously to provide integrated data output) 3. Additional map required with cable distance from nearest track/ OHE Pole to be included and provided as hard copy with GNSS coordinates of cable mentioned. seperate color code to be used for different trench for S&T cables, capture Images for Manhole/OFC JC Location with nearest reference point, if applicable. 5. In route map, Geotagging to be done at interval distance of 30 meters for approximate straight path. for track crossing, diversion, culvert, jointing locations, interval distance shall be less than 20meters or as as per site condition. 6. Data output will be provided on : 1. USB 2. Hard copy print. backup . \"\" 7. Client to provide the data engine access & Cable route locator Make Rycom USA Pathfinder PLDL for the data acquisition. 8. Training on Geo-Tagging of cable route included. Railway Per route kilometer price offer for S&T Cable Route Locating & Geotagging with depth , with digitized maps in .kml Format

70

37760

2643200

... More
Re-installation, Shifting & commissioning of existating Double Faced Coach Guidance Display Boardsasat outside shed at KWP per instruction of site in-charge. This includes all required accessories including hanging structure, fixing arrangements to commissioning the item. 62

30

4249

127483.2

... More
Installation & commisssioning of GGTronics MSDAC systems For Jaipur station. (Per DP)

8

17700

141600

... More
Installation, wiring, testing and commissioning of EI System with 'Hot Standby' architecture as supplied in distruibuted architecture at Durgapura station . It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipments, 63 interface equipments, power supply equipments and all other associated accessories to make completeEI system to be functional. Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time. Inspection: Consignee Inspection charges: None Payment terms: 100% after commissioning

1

1850000

1850000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.