Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date1 Apr 2025
Closing Soon29 Apr 2025
Tender Amount₹ 29,00,000 
Notes
Download

Costs

Summary

Repair / Maint Of Summer And Winter Applicances, Window And Split Acs And Misc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed.

950

-

-

... More
S&F in replacement ball bearing of size/No. 6203 confirming to IS complete all as specefied and as directed.

200

-

-

... More
S&F in replacement brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed.

500

-

-

... More
S&F in replacement broken bottom cover (bowl) of PVC suitable for ceiling fan of any make and model complete all as specefied and as directed.

40

-

-

... More
S&F in replacement shaft for ceiling fan as per existing size and shape complete all as specefied and as directed.

40

-

-

... More
S&F in replacement down rod (60-240) cm long suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed.

100

-

-

... More
S&F in replacement D Clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed.

500

-

-

... More
S&F in replacement PVC Canopies (Set of two) as required at site and complete all as specefied and as directed.

300

-

-

... More
S&F in replacement flexible wire of size 23/0.0076 standered copper conductor complete all as specefied and as directed.

1200

-

-

... More
S&F in replacement fan blade suitable for 1200mm sweep ceiling fan of any make as per existing complete all as specefied and as directed.

238

-

-

... More
S&F in replacement fan blade suitable for 1400mm sweep ceiling fan of any make as per existing complete all as specefied and as directed.

150

-

-

... More
Cleaning and preparation of old surface of the ceiling fan complete of size 1200/1400mm sweep and applying two coat of spray painting with synthetic enameled paint complete all as specified as directed.

980

-

-

... More
Taking down and dismantling of exhaust fan 225mm/ 300mm/ 375mm/ 450mm sweep of any make and model, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete to the satisfaction of Engineer in charge.

180

-

-

... More
Fixing only Exhaust fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperate in approprite item of this Schedule)

180

-

-

... More
S&F in replacement blades of suitable size for exhaust fan 225mm dully approved by GE complete all as specefied and as directed.

25

-

-

... More
S&F in replacement blades of suitable size for exhaust fan 300mm dully approved by GE complete all as specefied and as directed.

50

-

-

... More
S&F in replacement blades of suitable size for exhaust fan 375mm dully approved by GE complete all as specefied and as directed.

10

-

-

... More
S&F in replacement blades of suitable size for exhaust fan 450mm dully approved by GE complete all as specefied and as directed.

30

-

-

... More
S & F in replacement MS shaft for exhaust fan as per existing size and shape complete all as specefied and as directed.

35

-

-

... More
S&F in replacement MS back side cover including set and fastners (M 8,10,12,14,16 mm) for Exhaust fan of any sweep, size and make complete all as specefied and as directed.

400

-

-

... More
S&F in replacement of exhuast fan Parts like jaali, legs, rubber parts of any size complete all as specified and as directed.

45

-

-

... More
S&F in replacement exhuast fan louver shutters of size( 225/300/375/450 mm ) complete all as specified and as directed.

60

-

-

... More
Cleaning and preparation of old surface of the Exhuast fan complete of size ( 225/300/375/ 450mm) and applying two coat of spray painting with synthetic enameled paint complete all as specified as directed.

180

-

-

... More
Taking down and dismantling of cabin/wall mounting fan of any size/make/sweep, opening the cover separating the motor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective parts, fleaxible wire of size 23/0.0076, oiling/greasing the fan and re-assembling the fan, testing and refixing the fan complete all as specefied and as directed.

15

-

-

... More
S&F in replacement brass bush suitable for cabin/wall mounting fan of any make/model confirming to IS complete all as specefied and as directed.

15

-

-

... More
S&F in replacement push button cover of plastic suitable for cabin/wall mounting fan of any make/model with lock nut confirming to IS complete all as specefied and as directed.

5

-

-

... More
S&F in replacement push button regulator for selecting speed of cabin/wall mounting fan of any make/model complete all as specefied and as directed.

15

-

-

... More
S & F volume type fan regulator suitable for bldc fan not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed.

200

-

-

... More
S&F in replacement of ceiling fan BLDC motor kit for 5 star 1200/1400 mm, 26/32 watt, 230 volts 50 Hz complete all as specefied and as directed.

200

-

-

... More
Disconnecting the electric connection and taking out Window type AC 1.5 TR/ 2TR capacity from wall and overhauling and servicing AC by help of Blower gun, Soap water etc, oiling greasing as required and painting the AC including outer cover after work the machine refixng in original position and reconnecting the electric connection and making serviceable complent all as specified. (Note : Refrigerant gas will be measured & paid separately.)

100

-

-

... More
Disconnecting the electric connection and taking out Split type AC 1.5 TR/2 TR capacity from wall and overhauling and servicing the any type AC by help of Blower gun, Soap water etc, oiling greasing as required and painting the AC including outer cover after work the machine refixng in original position and reconnecting the electric connection and making serviceable complent all as specified. (Note :Refrigerant gas will be measured & paid separately.)

112

-

-

... More
Attending the complaints to observe the defects of Window type AC/Split AC of any capacity complete all specified and as directed. Note : (i) Supplying of new accessories/components required for the system shall be measured & paid separately. (ii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge. (iii) Completion of Each Job will be considered only after complete rectification of defect upto satisfaction of Engineer -in - Charge (iv) Complaint shall be attended on the same day after obtaining complaints & intimate to JE incharge by evening. (v) Rate for necessary stationary for complaint register & complaint slips shall be deemed to include in quoted rate. (vi) It complaint is not attended within 24 hrs, a sum of Rs. 250/- per complaint shall be recovered as penellty from contractor dues. Proper record of complaints given & rectified shall be maintain by the concerned JE and Contractor duly signed by all concerned.

100

-

-

... More
Dismantling of defective Window type AC/ Split type Air conditioner 1.5 TR indoor/outdoor unit of any make of following capacity for thorough checking / repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed by Engineer – In – Charge including transportation to workshop and back. Note : (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after (ii) Replacement of seald compressor unit, painting etc shall be measured and paid separately (iii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.

20

-

-

... More
Dismantling of defective Window type AC/ Split type Air conditioner 2.00 TR indoor/outdoor unit of any make of following capacity for thorough checking / repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed by Engineer – In – Charge including transportation to workshop and back. Note : (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after (ii) Replacement of seald compressor unit, painting etc shall be measured and paid separately (iii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.

25

-

-

... More
Taking out old unserviceable compressor rotary energy efficient/ reciprocal type and replacement the same compressor having same size , capacity and connecting with existing system testing to leakage including recharging of refrigerant gas after installation sealed unit with the split type AC 1.5 TR capacity commissioning complete all as specified and directed.

20

-

-

... More
Taking out old unserviceable compressor rotary energy efficient/ reciprocal type and replacement the same compressor having same size , capacity and connecting with existing system testing to leakage including recharging of refrigerant gas after installation sealed unit with the split type AC 2 TR capacity commissioning complete all as specified and directed.

15

-

-

... More
Taking down old unserviceable Aluminium fan blade and replacement the same suitable for outdoor unit of following capacity for split /mega ductable split type AC 1.5 TR capcity including complete all as specified and directed.

25

-

-

... More
Taking down old unserviceable Aluminium fan blade and replacement the same suitable for outdoor unit of following capacity for split /mega ductable split type AC 2 TR capcity including complete all as specified and directed.

20

-

-

... More
Taking out old unserviceable each blower motor from existing location of 1.5 TR capacity of Split AC, Window AC, mega split/ductable outdoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing of existing and size and reassembling the blower motor and fixed complete all as specified and directed.

15

-

-

... More
Taking out old unserviceable each blower motor from existing location of 2 TR capacity of Split AC, Window AC, mega split/ductable outdoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing of existing and size and reassembling the blower motor and fixed complete all as specified and directed.

20

-

-

... More
Taking out old unserviceable blower motor from existing location 1.5 TR capacity of Split AC Indoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing and reassembling the blower motor and fixed complete all as specified and directed.

14

-

-

... More
Taking out old unserviceable blower motor from existing location 2TR capacity of Split AC Indoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing and reassembling the blower motor and fixed complete all as specified and directed.

16

-

-

... More
Dismantling old unsv remote control assembly and replacing unsv items such as IC,PCB,Transformer and magnetic coil suitable for indoor 1.5 TR capcity split type AC and reassembling the same after testing complete all as specified and directed.

4

-

-

... More
Dismantling old unsv remote control assembly and replacing unsv items such as IC,PCB,Transformer and magnetic coil suitable for indoor 2.0 TR capcity split type AC and reassembling the same after testing complete all as specified and directed.

6

-

-

... More
Dismantling the old condensing coil and supply and fix the new condensing coil made of copper pipe 1.5 TR Capacity Split AC/ Window type AC complete all as specified and directed.

7

-

-

... More
Dismantling the old condensing coil and supply and fix the new condensing coil made of copper pipe. 2 TR Capacity Split AC/ Window type AC complete all as specified and directed.

5

-

-

... More
M&L for detecting leakage of Air conditioning system rectifying the leakage and testing 1.5 TR split AC complete all as specified and directed.

20

-

-

... More
M&L for detecting leakage of Air conditioning system rectifying the leakage and testing 2.0 TR split AC complete all as specified and directed.

15

-

-

... More
Taking down old unserviceable suction/Discharge 5/8" valve and replacement the same complete all as specified and directed.

4

-

-

... More
Taking down old unserviceable suction/Discharge valve do but 1/2" each and replacement the same complete all as specified and directed.

3

-

-

... More
Taking down old unserviceable suction/Discharge valve do 3/8" each and replacement the same complete all as specified and directed.

4

-

-

... More
Taking down old unserviceable suction/Discharge valve do 1/4" each and replacement the same complete all as specified and directed.

5

-

-

... More
Supply & filling refrigerant gas R-22 for charging of 1.0 TR to 3.0 TR capacity split, mega split type AC complete all as specified and directed.

10

-

-

... More
Supply & filling refrigerant gas R-32 for charging of 1.0 TR to 3.0 TR capacity split, mega split type AC complete all as specified and directed.

50

-

-

... More
Supply only suitable refrigerant gas R-407/410a for charging of 11 TR capacity central type Air Conditioner complete all as specified and directed.

30

-

-

... More
Dismantling of old window type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including brick work, plaster and making good by painting with existing color at old and new location complete all as specified and directed.

3

-

-

... More
Dismantling of old Split type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including necessary civil work complete all as specified and directed.

5

-

-

... More
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed. (Note : PVC cable and PVC conduit shall be ISI marked)

80

-

-

... More
As per srl item No. 61 but 2x 4 sqmm submain wiring with 1x 4 sqmm complete all as specified and directed.

100

-

-

... More
S&F Copper refrigerant pipe 3/8” complete all as specified and directed.

15

-

-

... More
S&F Copper refrigerant pipe 1/4" complete all as specified and directed.

12

-

-

... More
S&F Copper refrigerant pipe 1/2" complete all as specified and directed.

11

-

-

... More
S&F Copper refrigerant pipe 5/8" complete all as specified and directed.

10

-

-

... More
S &F Insulation for cooling line complete all as specified and directed.

50

-

-

... More
Taking out old unserviceable starting relay for following capacity 1.5 TR / 2 TR window / split type AC and replacement the same complete all as specified and directed.

10

-

-

... More
S&F in replacement Sheet metal enclosure for SP, with two pin earth plug and socket complete with one SP, MCB 20 Amps complete all as specified and directed.

10

-

-

... More
Dismantling the u/s 15mm drain water pipe and supplying and fixingthe same new drain out pipe 15mm dia including provision of saddles/clamps upto 100 mm above the ground level complete all as specified and directed.

60

-

-

... More
Comprehensive maintenance of central AC plant of capacity 3 x 11 TR (installed at 16 RAPID Div HQ, Ops room) Air condiioner of voltas make .The Each Job includes as under;- (i) Inspection, checking, cleaning with soap water and carbon tetra chlorite to the cooling coil and condenser unit (ii) Inspection, checking and repair of all electrical components (iii) Servicing of blower motors by greasing, oiling and servicing by cleaning thoroughly air filter iv) During the servicing of the unit existing refregerant (Gas) shall be pump down and to kept safe custody for re use. (v) Shell & tube type condenser - 03 Nos (vi) AHU with electric driven motor - 01 Nos (Note : (a) Above Each Job shall be carried out once in a every Qtr (b) Unserviceable item involving the above Each Job shall be measured and paid separately)

2

-

-

... More
Dismantling of old u/s Air filter and replacement the same for AHU of central AC 11 TR complete all as specified and directed.

1

-

-

... More
M&L for complete overhauling of Cooling Tower of 11 TR Central AC Plant by dismantling PVC Honeycomb fills, cooling fan, sprinklers, draining out of water, removing algae, silt, cleaning complete cooling tower body by removing scale, dust, dirt, cleaning existing external surface and servicing of mechanical components including repair / replacement of bottom tray of cooling tower, including replacement of gear box bearing, gear oil, mechanical coupling and overhauling of the complete transmission system of cooling tower and re-assembling all the dismantled components to its original position, testing complete all as specified and directed.

1

-

-

... More
Servicing of Hot water generator tank and elements after flushing the system of suction, discharge, liquid line and all valves and making hot water pump functional with proper necessary servicing by using CTC chemical and making operational complete all as specified and directed. (Note-Minor part rates i.e heating element is included in this quoted rates.)

1

-

-

... More
Supply and fixing in replacement electronic High Pressure and Low Pressure transducer/ transmitter of range 0 to 10 bar with glanded cable upto 5 metre as per installed in 11 TR chiller unit complete all as specified and directed.

2

-

-

... More
Dismantling of 1 to 3 HP motor electric from foundation and pump opening the same and only servicing of motor by cleaning internally and externally, varnishing of stator, greasing of bearing, fittings alignment, connecting electrically, re-fixing with pump after greasing & refilling gland packing of pump and testing etc complete all as specified and as directed.

6

-

-

... More
Supply only Lub oil for compressor for topping up of voltas or equivalent etc complete all as specified and directed.

10

-

-

... More
Supply and installation wet & dry bulb thermometer at A/C plant room etc. complete all as specified and directed.

2

-

-

... More
Disconnecting the electrical and mechanical connection of burnt electrical motors 1 to 2 HP capacity from the site , transporting to and from to work shop. Rewinding of electrical motors by dismantling and removing the burnt cut copper winding wire, cleaning , winding polyester based super enamelled copper wire of same gauge complete. After rewinding reassembling all parts including reinstalling connection to original position and testing on full load all as directed by Engineer in charge for different capacity of motor complete all as specified and directed.

1

-

-

... More
Disconnecting the electrical and mechanical connection of burnt electrical motors 3 to 5 HP capacity from the site , transporting to and from to work shop. Rewinding of electrical motors by dismantling and removing the burnt cut copper winding wire, cleaning , winding polyester based super enamelled copper wire of same gauge complete. After rewinding reassembling all parts including reinstalling connection to original position and testing on full load all as directed by Engineer in charge for different capacity of motor complete all as specified and directed.

2

-

-

... More
Painting of complete air conditioning plant equipments refrigerant/water suction / discharge / liquid piping of any specification with enamel paint of approved quality after preparation of surface including concealed fitments e.g., condenser , chillar, valves etc as per IS colour code of Central air conditioning plants including writing MES / SM No etc. complete all as specified and directed.

1

-

-

... More
Dismantling and opening up the defective Voltage Stablizers of capacity 5.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed.

10

-

-

... More
All as per Srl Item No. 82 here in before but capacity of 3.0 KVA complete all as specified and directed.

7

-

-

... More
Supply and fixing in replacement relay rating 08/05 Amps as per existing pattern suitable for voltage stabilizers 1.0/0.5 KVA complete all as specified and directed.

10

-

-

... More
Supply and replacement of PCB assembly complete with necessary accessories suitable for 5.0/3.0 KVA capacity voltage stabilizers as per existing model complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.