Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 72,590Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_703004_1Tender No
8317/GE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc or for shafts ,wells cesspits ,manholes ,pier holes etc n exc 10 sqm on plan and n exc in depth and getting out in hard rock complete all as specified and directed.
1
-
-
... More
Returning, filling in and including spreading, leveling, watering and well ramming in layers n exc 25 cm using excavated soil complete all as specified and directed.
63
-
-
... More
Removing excavated material exc 1.5 km but n exc 5.00 km and depoting where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
45
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
8
-
-
... More
M&L for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete (B1 1:2:4 20mm aggregate) complete all as specified and directed.
5
-
-
... More
M&L for PCC 1:4::8 type D-2 using 40 mm graded stone aggregate as foundation / mass concreting complete all as specified and directed.
6
-
-
... More
M&L for Pre-cast cement concrete block masonry with solid blocks type C1 (1:3:6) set in cement mortar 1:6, exc. 10 cm in width and setting in mortar complete all as specified and directed.
7
-
-
... More
M&L for hard core of gauge exc 63mm but not exc 100 mm depoted ,spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface broken stone or boulders complete all as specified and directed.
10
-
-
... More
Providing 100 mm thick PCC 1:3:6 type C-2 (40 mm stone agg) as in sub bases complete all as specified and directed.
60
-
-
... More
M&L for 100mm thick PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in floors finished even and smooth without using extra cement complete all as specified and directed.
60
-
-
... More
M&L for forming 12mm thick expanon joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for100mm thick slab
2
-
-
... More
M&L for round bars 10 mm dia and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming complete all as specified and directed.
200
-
-
... More
-Ditto- all as per item No-15 above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders complete all as specified and directed.
80
-
-
... More
M&L for preparation of newly plastered surfaces and applying two coats of cement based paint of approved tint complete all as specified and directed.
33.74
-
-
... More
Excavation in post holes in any type of soil, n exc 0.50 cum in each post, getting out returning, filling in and ramming earth or broken rubble mix with earth around in layers n exc 25 cm watering and removing surplus soil to a distance n exc 50 M and making good surface and all as specified.
2
-
-
... More
M&L for framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. Railings, frame work of of water tanks and ssimilar work conforming to Fe-410 complete all as specified and directed.
20
-
-
... More
M&L for applying two coats of synthetic enamel paints on old steel surfaces over a coat of red oxide primer including surface preparation complete all as specified and directed.
5
-
-
... More
M&L for joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match IN cm 1:4 15 mm thick screed complete all as specified and directed.
10
-
-
... More
S&F for aluminim snap grid frame work for falce ceiling complete all as specified and directed.
7
-
-
... More
Providing and Fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
7
-
-
... More
M&L for 10 mm thick rendering over PCC block masonry wall surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
33.74
-
-
... More
Labour only for Dismantling of RCH hut properly with all necessary arrangement and precautions complete all as specified and directed.
1
-
-
... More
Coveyance of RCH parts from stores to the site by suitable mode of conveyance upto 10 km all as directed by authority complete all as specified and directed.
1
-
-
... More
Labour and transportation for shifting of RCH hut upto 500 mtr from existing location including all necessary arrangement complete all as specified and directed.
1
-
-
... More
Labour only for reerection of RCH at proposed site all as directed by authority.
1
-
-
... More
Vehicle for carrying workers (5 nos) from camp to site (morning 8 O clock ) and back to camp (in evening by 5 o clock) upto 10.00 km complete all as specified and directed.
15
-
-
... More
Extra payment to firm if work delayed beyound 15 days complete all as specified and directed.
1
-
-
... More
M&L for mild steel purpose made with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 30.cm long, dia of shank exc 12 but n exc 20 mm complete all as specified and directed.
10
-
-
... More
M&L for hand rails, half rounded or other stock section or core for wooden hand rails straight portion drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps incl embeding in concreteand screwing etc wind ties for roof incl securing bolts posts and struts in fencing including cuttig tops to shape as dircted, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc incl all necessary drilling, bolting or rivitting etc and similar works conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
10
-
-
... More
M&L for Mild steel J hook rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30 cm long Diameter of neck in 25 mm complete all as specified and directed.
5
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc or for shafts ,wells cesspits ,manholes ,pier holes etc n exc 10 sqm on plan and n exc in depth and getting out in hard rock complete all as specified and directed.
1
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc or for shafts ,wells cesspits ,manholes ,pier holes etc n exc 10 sqm on plan and n exc in depth and getting out in soft disintegrated rock complete all as specified and directed.
1
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc or for shafts ,wells cesspits ,manholes ,pier holes etc n exc 10 sqm on plan and n exc in depth and getting out in hard dense soil complete all as specified and directed.
1
-
-
... More
Form work to sides of concrete foundations ,footings , bases of columns ,raft and raft beams , sides and soffits ( if any) of foundation and plinth beams and milar vertical or to a batter flat fair finished surface complete all as specified and directed.
5
-
-
... More
Form work to sides of pillars , posts , struts , piers , columns and stantions rough finished surface square , rectangular or polygonal complete all as specified and directed.
5
-
-
... More
M&L for providing reinforced cement concrete type B1 (1:2:4) ung 20 mm graeded stone aggregate as in columns ,pillars piers ,posts and struts complete all as specified and directed.
3
-
-
... More
M&L for M-25 providing reinforced cement concrete type B1 (1:2:4) using 20 mm graeded stone aggregate as in foundation ,including rafts,footings foundation beams , plinth beams, bases of columns etc ,basement slab ,underreamed piles and mass concrete all as specified.
3
-
-
... More
Form work to sides of pillars , posts , struts , piers , columns and stantions rough finished surface square , rectangular or polygonal complete all as specified and directed.
15
-
-
... More
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level), including removing out of MD Land complete all as specified and directed.
10
-
-
... More
Stability test of building including submitting test report complete all as specified and directed.
1
-
-
... More
M&L for stone walling of random or polygonal rubble ,uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 brought upto course complete all as specified and directed.
8
-
-
... More
M&L for 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces on fair face , surface finished even and smooth without using extra cement complete all as specified and directed.
30
-
-
... More
M&L for cement concrete 1:2:4 type B-1(20 mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
0.81
-
-
... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement incl moulds, forms, mitred/stripped ends complete all as specified and directed.
10
-
-
... More
Add or deduct to above mentioned item No for 11 for each 25 mm girth or part thereof over or under 30 cm girth complete all as specified and directed.
120
-
-
... More
M&L for providing precast cement concrete1:2:4 type B-1 in cover slabs (for manholes etc ) ,shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and directed.
2
-
-
... More
M&L for concrete bed in cement concrete 1:4:8 bed to drain pipes incl. packing under and haunching against the sisides of pipes after they are laid and tested bore of pipe 150mm complete all as specified and directed.
137
-
-
... More
M&L for salt glazed stone ware drain pipe 150mm internal dia laid in trenches and jointed, including dismantling complete all as specified and directed.
137
-
-
... More
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level), including removing out of MD Land
10
-
-
... More
Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles
13.5
-
-
... More
Demolition of reinforced cement concrete on roofs, floors (other than ground floors) beams ,stairs ,landing, chajjas, water tank and similar suspended work
15
-
-
... More
Taking down chowkats or frames with shutters exc 1.50 Sqm each but not exc 4.00 sqm each (without taking off shutters from the frames).
7
-
-
... More
Taking down chowkats or frames with shutters not exc 1.50 Sqm each (without taking off shutters from the frames).
3
-
-
... More
Taking up or down steel tubing and connections of 15mm bore, fixed on walls, ceiling, floors etc.
10
-
-
... More
Taking up or down steel tubing and connections of 20mm bore, fixed on walls, ceiling, floors etc.
15
-
-
... More
Dismantling old unserviceable RCC / PVC water tank capacity exc 250 and not exc 500 ltrs & removal from site complete all as directed
1
-
-
... More
Taking out the existing LT cables of size 25 sqmm 4 core after disconnecting from LT Panels, DBs and other similar equipments from trenches, wall etc and kept aside for schedule of credit all as required and directed at site. Note: excavation and earth work joints will be measured and paid seprately
250
-
-
... More
Taking down old Unserviceable air termination rod of any size and capacity complete all as specified and as directed by Engineer-in-Charge.
1
-
-
... More
Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
Taking down old Unserviceable GI rusted pipe from roof or wall any size and position including making good to disrurbed surface of wall and roof complete all as specified and as directed by Engineer-in-Charge.
3
-
-
... More
Demolition of cement concrete (un-reinforced) of any description and any position n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-Charge.
0.1
-
-
... More
Dismantling of existing broken PCC earth chambers of any description and M&L providing earth chamber of size 300 mm x 300mm (Internal size),and depth 280mm and 75mm thick with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Taking down carefully copper/Aluminium point wiring for one light/fan/socket/power point and taking down of teak wood batten / PVC casing caping and making good disturbed surfaces of walls/ceilings /floors etc incl dismentling of fittings.
25
-
-
... More
Taking up or down GI Water tubing and connections of 20 mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed.
Note :- (I) Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
(II) Before quoting the tender , contractor must see the feasiblity of site and see the location of site and must be ensure that no sewage line and cable will be damaged.
20
-
-
... More
Taking up or down GI Water tubing and connections of 25 mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed.
Note :- (I) Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
(II) Before quoting the tender , contractor must see the feasiblity of site and see the location of site and must be ensure that no sewage line and cable will be damaged.
20
-
-
... More
Material and labour for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm SSRngle core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade including 1.50 Sqmm SSRngle core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC caSSRng & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in New wooden terminal box for mounting fittings like switches, sockets, regulators etc with and including new 3mm thick phenolic laminated sheet top cover, fixed on top of terminal box complete, all as specified & directed.
14
-
-
... More
All as per item No. 69 here-in-before but for one ceiling fan point controlled by one switch and regulator complete, all as specified & directed.
1
-
-
... More
All as per serial item No. 69 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board complete, all as specified & directed.
5
-
-
... More
All as per serial item No. 69 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete, all as specified & directed.
.
5
-
-
... More
M&L for surface Sub main wiring with two runs of 4 sqmm single core PVC insulated unsheathed multistranded with copper conductor cable , 1100 Volts FRLS-H grade ISI marked drawn through in and including stove enamelled steel conduit & including one run of 4 sqmm PVC insulated unsheathed stranded copper conductor cable green in colour for earth continuity conductor and making good the distrubed surfaces after completing the work and clearing the site complete all as specified and directed. Note :- Two runs of 4 sqmm cable and one run of 4 sqmm earth wire and steel conduit pipe shall be measured as one length.
20
-
-
... More
S&F of switch socket combination 2 in 1, 5 and 15 Amps multipurpose flush type complete all as specified and directed.
10
-
-
... More
Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
25
-
-
... More
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 with brushless direct current motor (BLDC) complete all as specified and directed.
1
-
-
... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
4
-
-
... More
S&F LED type street-DRACO SERIES light luminaire 25 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed.
5
-
-
... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
2
-
-
... More
Supply and fixing of LED desk light as per sample with multi function to regulate the light as per the requirement of the controller complete all as specified and directed.
2
-
-
... More
S&F Ceiling rose with earth terminal connection, 3 terminal PVC/ polycarbonate body complete all as specified.
11
-
-
... More
Supply, installation, testing, and commissioning of twin LED-based aviation obstruction lights, ultra-slim and energy-efficient, suitable for installation at a Runway Controller Hut. These lights shall provide a steady-burning red light for night-time visibility and low-intensity obstacle marking, with a total power consumption of 20W to 25W per unit. The lights will be housed in a weatherproof, impact-resistant polycarbonate or tempered glass cover for enhanced durability. The system shall operate on a 220V AC supply and include built-in surge protection to safeguard against electrical surges, lightning, and voltage fluctuations. The lighting system will be fully compliant with ICAO (International Civil Aviation Organization) Annex 14 and DGCA (Directorate General of Civil Aviation) guidelines for low-intensity obstacle lights.including complete wiring and other necessary minor work all as directed by Engr-in-Charge.
1
-
-
... More
S&F Sheet Metal enclosure for VTPN DBs, 4 Ways, Double Door(IP-43), built- in bus bars complete suitable for 415 Volts, AC, 50 Hz supply, suitable for incoming MCCB and outgoing MCBs and fixed in recess in brick masonary wall complete all as specified and directed by the Engr-in-charge. Make - Legrand, C&S, Hevells
1
-
-
... More
M&L for 4 Pole MCCB 63, 50 Hz, 415 V with rupturing capacity 16 KA.complete including connecting to MCB DB all as specified and directed. Make/brand: Havelle/ABB/Legrand
1
-
-
... More
S&F for MCB 6-40 Amp, single pole 240 Volt complete all as pecified & directed.
12
-
-
... More
Supply&Fix single pointed air termination aluminium rod 12mm dia, 300 mm dong complete all as specified and as directed by Engineer-in-Charge.
1
-
-
... More
Supply&Fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 50 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
2
-
-
... More
M&L for test point terminal block made of gun metal or phosphorus bronze 75X75X25 mm thick with arrangement by making 2 Nos of hole suitable with and 2 Nos of nuts, bolts & washer of 8mm dia for fixing GI strip complete all as specified and as directed by Engineer-in-Charge.
2
-
-
... More
Supply and Fix Tube galvanised, 40mm bore, medium grade with all fittings and fixed to walls and ceiling or laid in floor all as specified.complete all as specified and as directed by Engineer-in-Charge.
3
-
-
... More
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing of size 25x4mm galvanised iron strip complete all as specified and as directed by Engineer-in-Charge.
16
-
-
... More
M&L for PCC 1:2:4 type B-1, 20 mm graded aggregate filling and mass concrete, for road finishing, PCC blocks, earthing pit cover, and foundation concrete complete all as specified and directed by Engr-in-Charge.
0.03
-
-
... More
Supply&Fixing for MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only.
0.5
-
-
... More
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified by Eng-in-charge
250
-
-
... More
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified.
70
-
-
... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by engineer-in-charge
28
-
-
... More
M&L for tibba sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr-in-Charge.
19
-
-
... More
M&L Stone patti 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35 cm wide and not less then 60 cm in length laid dry abutting each other with gap between adjacent slab not excedding 10mm over sand cushioning complete all as specified and directed.
71
-
-
... More
M&L for GI Tubes, of size 40mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
2
-
-
... More
Boring holes under road pavement by bocky manually, in any type of soil upto 200 mm bore Complete all as specified and as directed.
10
-
-
... More
M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and directed by Engineer-in-Charge.
1
-
-
... More
M&L for galvanized steel water tubing medium grade of 20 mm bore with & including all fittings such as bends,elbow,tee,union etc. and fixed complete to walls with using of clamps and ceilings or laid in floors. Note :- Excavation & earthwork shall be measured & paid for separately.
20
-
-
... More
M&L for galvanized steel water tubing medium grade of 25 mm bore with & including all fittings such as bend,elbow,tee,union etc.complete laid in trenches. Note :- Excavation & earthwork shall be measured & paid for separately
20
-
-
... More
S&F 20 mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked.
1
-
-
... More
Cutting and screwing the existing steel tubing 20 mm bore for addition & alteration or lengthening screw on pipe to form connector complete all as specified and as directed.
3
-
-
... More
Cutting and screwing the existing steel tubing 25 mm bore for addition & alteration or lengthening screw on pipe to form connector complete all as specified and as directed.
3
-
-
... More
Supply and install wall split units indoor / outdoor complete with cordless remote control unit and with in built heating and cooling arrangements and digital inverter twin rotary of capacity 1.5 TR all as specified and directed by engineer-in-Charge.
1
-
-
... More
Supply & Install Wall mounted type Automatic Voltage Stabilizer with digital display for low and high voltage correction, suitable for correction on single phase 50 cycles AC supply and designed for input voltage of 160 volts to 260 volts and out put voltage stablized between 230 volts + 1% including time leg relay complete all as specified and as directed.for capacity 4 KVA all as specified and directed by engineer-in-Charge.
1
-
-
... More
S&F for sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacity all as specified and directed by engineer-in-Charge.
1
-
-
... More
Supply, installation, testing, and commissioning of an online Uninterruptible Power Supply (UPS) system with a rated capacity of 7.5 KVA, designed to provide a minimum backup of 30 minutes under full load conditions. The UPS shall be compatible with a three-phase AC input voltage range of 300V to 450V and shall deliver a regulated three-phase output of 415V ±1%, ensuring stable and uninterrupted power supply to connected equipment. The system shall include a high-efficiency, microprocessor-controlled inverter, automatic bypass facility, and intelligent battery management system to optimize performance and extend battery life. The battery bank shall be of a sealed maintenance-free (SMF) or VRLA type, capable of delivering the required backup time with appropriate AH rating. Also including the supply and laying of all necessary cabling, earthing, mounting arrangements, and safety protections such as overvoltage, short circuit, and overload protection. The installation shall be carried out as per relevant IS/IEC standards, and all required functional tests shall be conducted to ensure seamless operation complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for earthing to electric equipments / panels with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized wire 4mm as earth lead, welding at top of electrode and other end of strip connected to equipment body/panel/test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level fixed along equipment body/panel with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past