Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date7 Nov 2024
Closing Soon28 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 38,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678130_2Tender No
8211/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Fixing only chain link fencing including line wires any mesh, size and type to any type of standards, rail straining bolts, etc, including provision of binding wire.
87
-
-
Supply only chain link MS glavanised fencing of any size or type, complete all as specified and directed.
Note:- Weight of chain link fencing shall be assessed by BOO
192
-
-
Supply only MS 10mm dia round bars as line wire for chain link fencing, complete all as specified and directed.
134
-
-
S&F for mild steel as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed. drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
515
-
-
S&F for mild steel screws bolt (machine made) with hexagonal or square heads one end screwed, each screwed end have two washer and one nut, dia of shank 11mm-15mm and length of bolt exc 5 cm and not exc 10 cm, complete all as specified and directed.
24
-
-
M&L for preparation of new steel and iron surfaces of any descripltion, exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
49
-
-
M&L for preparation of new steel and iron surfaces of any descripltion, not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
8.5
-
-
S&F for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed by Engr in charge.
2.2
-
-
Removing excavated material not exc. 50m and deposting where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed.
10.5
-
-
Dismantling of wall and ceiling or insulation boards/ slabs / PVC panelling any thickness and in any position incl frame grid and cover fillets and framework etc, complete all as specified and directed.
112
-
-
M&L for designer type gypsum ceiling board / mineral fibre board of size 595mm x 595mm x 12mm thick as in ceiling, fixed with screws on GI grid frame work of size 600mm x 600mm, GI T-section of size 25mm x 25mm x 1.25mm, GI L-section 25mm x 25mm x 1.25mm, hanging arrangements with roof with GI wire not less than 4.00 mm dia, including applying two coats of distemper oil emulsion (of approve shade) after preparation of surface, including taking down existing ceiling board of any description complete as per manufactures instructions , complete all as specified and directed by Engineer-in-Charge.
112
-
-
Surface dressing not exc 15cm deep in soft/loose soil, complete all as specified and directed.
27
-
-
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate as in subbase, complete all as specified and directed.
27
-
-
M&L for 100mm thick cement concrete work in hard standing of flexural strength 40 Kg per sqm in field using 400 kg of cement per cum thickness of concrete 25 cm or less, complete all as specified and directed.
2.7
-
-
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but not 4 Sqm each, complete all as specified and directed.
6
-
-
S&F for powder coating aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and directed.
34
-
-
S&F for powder coating aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
81
-
-
M&L double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, complete all as specified and directed.
16
-
-
S&F for 4.8mm thick sheet glass, ordinary quality and in square exc 0.5 sqm in each pane in any position, complete all as specified and directed.
30
-
-
S&F in repair door closer hydraulically regulated, design No 3 universal type suitable for door shutter 851 mm to 1000 mm in width and of weight 61 to 80 Kg each cast iron body, complete all as specified and directed.
8
-
-
M&L for PCC 1:2:4 type B2 (40mm graded stone aggregate) filling in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) and other similar work, complete all as specified and directed.
1.5
-
-
S&F for mild steel for framed structure like trussed, purlins, crane gantries, post rails and fastenings and heavy bracket framming (Beam, Tee, Angle, Channels, Tube, flate sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified and directed.
730
-
-
M&L for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr. in-charge.
70.6
-
-
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
75
-
-
M&L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sqmm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 sqmm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge.
-
-
-
One light/fan/exhaust fan point controlled by by one switch, complete all as specified and directed.
75
-
-
S&F for switch piano flush button single pole one way 5 amp 240 volts, complete all as specified and directed.
75
-
-
Taking down old U/S light fitting and supply, installation, Testing and commissioning of LED luminaire 600mm x 600mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source 28 Watt with nominal system lumen output of 2800 lumens and a minimum system efficacy of 100 lm/W. The luminarie shall have a rated system lifetime of 50,000 burning hours at L70. The luminarie should have a color temperature of 6500K and CRI 70. The luminarie shall meet IP 66 rating and IK 09 rating with THD 20% and PF 0.9 including connecting up with driver three core flexible copper conductor cases, complete all as specefied and directed.
75
-
-
Supply, install, testing and commissioning of Servo controlled voltage stabilizer 125 KVA (Confirming to BIS 9815:Part 1 :1994) Three phase,50 Hz, Naturally Oil cooled , indoor , unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks four nos , digital display type with multi functional meter , relay free smooth and silent operation with 1st filling of Transformer oil up to level ( minimum 330 ltr BIS certified ) having following specification:-
Input voltage 360V-480V,Output voltage stabilized at 415V ± 1% Rated frequency 50 Hz, No distortion in wave form, Response time not to exceed 20 mile seconds, Sensitivity (±)1%, Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase, Efficiency more than 95%,
Note-(i) Similar or higher bcapacity specification & drawing shall be approved by Accepting officer
(ii) Pre dospatch Inspection of stabilizer unit shall be carried out at manufacturer's factory as per IS 9815 before dispatching to site by rep of Accepting officer within the rate quoted of item
1
-
-
Supply, install, testing and commissioning of Isolation transformer 125 KVA, Three phase ,50 Hz , indoor , Copper wound , oil cooled , class ofinsulation A ,metallic body duly powder coated designed for input Voltage range 415±5% and output voltage range 415±5% ,Ratio 1:1 , Vector Group :Dyn 11, Delta- star with first filling of transformer oil ( minimum qty 280 LTR ) of requisite dielectric strength up to level , efficiency more than 95 % , separate neutral bushing shall be brought out for earthing the transform shall be confirming to Is 1182: 2014
Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter, adequate number of cooling radiators , lifting hooks one set , Earthing terminal two nos complete, testing as per BIS 9815 and 2026, complete all as specified and directed.
1
-
-
Cont. item No 31.00.....
Note:-(i) Specification & drawing shall be approved by Accepting Officer
(ii) Pre commissioning test of transformer shall be carred out by Rep of Accepting Officer.
(iii) Factory test of transformer will be carried out in presence of Rep of Accepting Officer and necessary arrangement for visit and testing will be provided by contractor without any extra cost. (iv) Cost af all arrangements, machinery and labour for fixing and installation of transformer on specified site is included in quoted rates.
(v) Contractor has to produce OEM factory test certificate.
-
-
-
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%