If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Aerospace and Defence
Eprocure
Opening Date14 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 36,90,000
Costs
EMD
₹ 73,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683871_1Tender No
8935-24/GE/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
15
-
-
Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed.
15
-
-
M&L for reinforced cement concrete M-25 Design Mixes 1:2:4 type B0 using 12.5mm graded stone aggregrate in Chajjas; complete all as specified and directed by Engr-in-charge.
1.5
-
-
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
20
-
-
S & F TMT Bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
200
-
-
S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
70
-
-
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge.
14
-
-
Supply only Integral water proofing compound complete all as specified and directed.
50
-
-
M & L for 50 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:30 complete all as specified and directed by Engineer-in-Charge.
360
-
-
M&L for Roof treatment to RCC roof as follows:-
(a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge.
Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
360
-
-
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed with grey cement and pigment over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment and no pigment in floors/roof, and cut and polished complete all as specified and directed.
360
-
-
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engr-in-Charge.
2
-
-
Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
15
-
-
Material and labour for brick work with Fly Ash bricks straight or curved on plan any radius half brick thick walls, built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
15
-
-
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed.
2
-
-
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) and removing from site complete all specified and directed directed.
28
-
-
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
110
-
-
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
48
-
-
M & L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc conforming to Fe-290 (Gde-E-165) complete all as specified and directed by Engr-in-charge.
170
-
-
S&F hold fast of flat iron conforming to Ge-290 (Gde-E-165) including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified & directed.
14
-
-
S&F 125 mm long aluminium alloy handles, fabricated type, anodised complete all as specified & directed by Engr-in-charge.
72
-
-
S&F aluminium anodised barrel tower bolt of extruded section 200mm long all as specified & directed by Engr-in-charge.
72
-
-
S&F 100 mm long butt hinge, extruded stainless steel with stain less steel hing pin, complete all as specified and directed by Engneer -in-Charge .
108
-
-
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engneer -in-Charge .
20
-
-
S&F 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engneer -in-Charge .
20
-
-
S&F 300 mm long aluminium sliding bolt plate type stove enamelled black with bright bolt not less than 16 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified
10
-
-
S&F in repair 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed.
8
-
-
S & F 2nd class hard wood (sal) or any other 2nd class hard wood articles not exc 200 Cubic Centimeter each Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labour etc complete all as specified
8
-
-
S&F factory made window, made out of MS hollow section of size 79mm x 39mm x 1.6mm thick frame with double shutter (glazed and wire guage shutter) made out of Z section using flush butt welding and tenon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutter, locking arrangement as per sample approved by GE, provided with knob 'Z' section handles 100mm size and 150 mm long hook and eye welded to frame and shutter,four number legs welded to frame including necessary flat iron beading for securing wire gauge and 8nos tower bolt 150mm length and guard bar used only 12mm square bars(guard bar measured and paid separately under respective item) etc complete all as specified & directed by Engineer-in-Charge.
10
-
-
S&F steel ventilator with top hung shutter incl hinges, handle, steel peg stay complete all as specified and directed by Engineer-in-Charge
17
-
-
S & F stainless steel wire cloth high quality corrosion resistant of grade SS 304, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
45
-
-
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
690
-
-
Material and labour for 25 mm thick Cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floor or laid under floor etc complete all as specified and as directed by Engineer-in-charge.
150
-
-
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
120
-
-
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.36 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
30
-
-
M&L for glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engneer -in-Charge
540
-
-
M&L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
3
-
-
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
80
-
-
Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
875
-
-
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:6 on wall, finished fair even and smooth all as specified and directed.
275
-
-
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 on wall, finished fair even and smooth including mixing with WPC all as specified and directed.
400
-
-
M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finished fair and even without using extra cement complete all as specified & directed by Engr-in-charge.
200
-
-
Material and labour for preparing newly plastered or pointed surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
110
-
-
M&L for two coats of white wash on old plastered surfaces on wall incl preparation etc. complete all as specified and directed.
900
-
-
M&L for 3 coats of white wash on newly plastered surfaces on ceiling incl preparation etc. complete all as specified and directed.
200
-
-
M&L for two coats of white wash on old plastered surfaces on ceiling incl preparation etc. complete all as specified and directed.
1200
-
-
M&L for two coats of acrylic distemper on newly plastered surfaces of walls over and including one coat of primer and 3mm thick wall care putty including preparation of surfaces complete all as specified and directed.
290
-
-
M&L for complete removal of existing treatment and two coats of acrylic distemper over and including one coat of primer and 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
2187
-
-
M&L for preparation of new plastered and applying two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3 mm thick wall care putty complete all as specified and directed by Engineer-in-charge.
400
-
-
M&L for preparation of old plastered and treating with two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3mm thick wall care putty complete all as specified and directed by Engineer-in-charge.
900
-
-
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified.
10
-
-
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of red oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge.
15
-
-
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of old surfaces with one coat of synthetic enamel paint ordinary tint all as spefified and directed
400
-
-
M&L for preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and apply one coats of synthetic enamel paint all as specified.
250
-
-
S & F 4.00 mm thick figured glass, pin head glazing with oil putty, n.exc 0.5 Sqm in each pane complete all as specified and directed.
16
-
-
S & F 4.00 mm thick sheet glass, ordinary quality and glazing with oil putty/beading in squares n.exc 1.5 Sqm in each pane all as specified and directed.
20
-
-
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engr-in-Charge.
35
-
-
Taking down eaves gutters and rainwater pipes/PVC SWR (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc.,complete all as specified and directed by Engineer-in-Charge. (measured overalll as fixed along the centre line over fittings and accessories)
250
-
-
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge.
250
-
-
S&F 450mm long mild steel GI pipe, medium grade of size 40mm dia as in spouts pipe in sunken floor including making holes in RCC and making good with CM 1:1 or PCC (1:2:4) complete all as specified and directed by Engineer-in-Charge.
14
-
-
S & F 110 mm bore PVC (SWR) bends any radius
10
-
-
S & F in repair 100 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed by Engineer-in-Charge.
65
-
-
S & F in repair cast iron 100 mm bore branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
18
-
-
S & F in repair cast iron 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
12
-
-
S & F in repair 75 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed by Engineer-in-Charge.
60
-
-
M & L in repairs 75 mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified and directed by Engineer-in-Charge.
24
-
-
S & F in repair cast iron 75 mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
12
-
-
S & F in repair cast iron 75 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
18
-
-
Taking down 15 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
150
-
-
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
150
-
-
Taking down 20 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
110
-
-
S&F 20 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
110
-
-
Taking down 25 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
60
-
-
S&F 25 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
60
-
-
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
45
-
-
S&F CP brass stop valve/ angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-charge.
20
-
-
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge.
72
-
-
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 25 mm bore complete all as specified and directed
6
-
-
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore complete all as specified and directed
6
-
-
S&F 8mm thick border designed looking mirror of selected quality glass mounted on laminated board fixed with PVC plugs and chromium plated brass screws and cup washers/adhesive including necessary fixing arrangement complete all as specified and as directed by Engineer-in-Charge.
16
-
-
S&F in repair tubular towel rail, Brass chromium plated 20 mm dia, 'D' type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
18
-
-
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests but including CI 'P' trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge.
15
-
-
S&F in repair vitreous china white wash down water closet pan, padestal pattern, white, including fixing bolts, but excluding flushing cistern and flush pipe and connection to drain (or out going pipe) etc. complete and making good to floor all as specified and directed
3
-
-
S & F in repairs Vitreous China urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe complete all as specified and directed.
12
-
-
S&F in repair vitreous china wash hand basin coloured counter top (bowl type/oval shape) of size 550x400mm, including 32mm dia chromium plated waste coupling long screwed shank and fly nut, flanged end including cutting for and pinning in ends of brackets in CM 1:3 all as specified .
18
-
-
S&F in repairs grating doom CP 100 mm dia of SS with waste hole complete all as specified and directed
30
-
-
S & F 32 mm PVC waste down pipe suitable for WHB and urinal complete all as specified and directed by Engr-in -Charge
18
-
-
S&F in repair pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed. Note: Wt not less than 450 gms
18
-
-
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed.
18
-
-
S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm long complete all as specified and directed.
45
-
-
Supply & fixing in repairs CP swivel shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed complete all as specified and directed by Engr-in-Charge.
18
-
-
Supply and fixing in repair glass corner shelf with CP brackets and CP railingcomplete all as specified and directed by Engineer-in-Charge.
18
-
-
S&F in repair chromium plated fancy type soap dish 10cm/15cm complete all as specified and directed by Engineer-in-Charge
18
-
-
Dismantling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified and directed.
5
-
-
S&F for Rotational moulded polythene water storage tank 2000 ltr capacity vertical with closed top, ISI marked hoisted and fixed in position connection nipple 2 Nos complete all as specified and directed..
2
-
-
S&F for Rotational moulded polythene water storage tank 1000 ltr capacity vertical with closed top, ISI marked hoisted and fixed in position connection nipple 2 Nos complete all as specified and directed..
3
-
-
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed for 25 mm dia pipe complete all as specified and directed.
Note: Minimum weight 20 mm - 210 gms
5
-
-
M&L continous brick edging using old size bricks width equal to the depth of the brick laid dry on end vertically complete all as specified & directed by Engr-in-charge .
25
-
-
M&L for 75mm thick PCC (1:2:4) type D-2 using 40mm graded stone aggregate as in sub base below floors and paving etc all specified and directed.
10
-
-
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc and laided, bedded and pointed in any mortar complete all as specified and directed.
8.5
-
-
Material and labour 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding the edges half round on exposed side over and including 20mm thick screed base in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
25
-
-
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
50
-
-
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
10
-
-
S&F in repair drapery stainless steel rods, standrad quality, not less than 28 mm dia with brackets and heads at both ends, etc. complete all as specified and directed by Engr-in-charge.
240
-
-
M & L PCC type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in benching /haunching manhole, coping & bed block etc including weathering, slightly, rounded or chamfered angles and throating including necessary form work including forming channels Complete all as specified.
2.3
-
-
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
0.5
-
-
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
53
-
-
M&L Machine pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over and including Fazilka sand cushion and incl dismantling all as specified and directed.
53
-
-
E/M Portion
Taking down carefully existing copper/aluminium point wiring for light, socket or power bell complete with fittings such as switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of wall, matching the colour with existing surface complete all as specified and directed
84
-
-
Material and labour for concealed Point wiring for one light point controlled by one way one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
64
-
-
,---ditto--- all as per srl item No 115 above but One socket out let 5/6 amps point controlled by one switch on the same board completed all as specified and as directed by Engineer-in Charge
6
-
-
,---ditto--- all as per srl item No 115 above but One socket out let 5/6 amps point controlled by one switch on independent board completed all as specified and as directed by Engineer-in Charge
6
-
-
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
8
-
-
Supply and fix modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
80
-
-
Supply and fix modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
8
-
-
Supply and fix modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
12
-
-
Supply and fix modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
18
-
-
Supply and fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed.
24
-
-
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.
39
-
-
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
30
-
-
Supply and fixing ventilating Air fresher Fan of size 250mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge.
Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
6
-
-
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.
Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
100
-
-
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
2
-
-
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
4
-
-
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
10
-
-
Supply and fixing PVC Blanking Plates one way with internal lock complete all as specified and as directed by Engineer-in-charge.
2
-
-
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
4
-
-
Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body with 3 level safety, capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet with feroglas coated (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for hot and cold water of suitable length, three core PVC insulated PVC Sheathed copper conductor flexible cable, including 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Note : Old U/S water heater will be deposited to MES store yard.
6
-
-
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications
(a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt.
(b) Input Voltage range : 140 to 270 volts
(c) Temp operating range : Minus 10°C to Plus 45°C
(d) Power factor : Minimum 0.95
(e) CRI : More than 70
12
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI Medium grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
2
-
-
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified.
Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
28
-
-
Supply and laying and commissioning LT XLPE cable 1100 Volt grade 50 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 7098 (Part-I) laid in trenches/along poles/ through pipe/through duct complete including taking out of existing cablel all as specified and directred.
Excavation and earthwork shall be paid and measured separately
80
-
-
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
19.44
-
-
Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed.
12.34
-
-
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
7.1
-
-
M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified.
(Note : Punned thickness shall be considered for payment purpose)
5.83
-
-
Supply and laying well brunt clay brick old size class 'B' laid dry flat for protection over the cable, width equal to length of cable complete all as specified and directed.
0.64
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%