Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_637866_1Bid Award Id
ViewTender No
8800/23-24/66/07/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per items ser No 1 above for system No 5 (42 HP) installed at MH Jodhpur main bldg terrace
4
-
-
... More
All as per items ser No 1 above for system No 6 (56 KW) installed at MH Jodhpur Adm Bldg terrace Make : Voltas
4
-
-
... More
Servicing and cleaning of Cassette unit (ceiling mounted) of VRV System of any make any capacity installed at various location in NEW MH and Adm Block Jodhpur including Filter Wash, Cooling / Evaporative coil wash and remove the dust, replacement complete all as specified and as directed Note:- 1. Servicing of ceiling mounted cassette type will be carried out two times during contract period as directed.
122
-
-
... More
Servicing and cleaning of Air Handling Unit(AHU) indoor type for VRF system of any make any medel/capacity installed at various location, including Filter Wash ,Cooling/Evaporative Coil Wash and remove the dust particles, cleaning/greasing of all part including minor replacement parts such as nut bolts screw of any type for system units upto satisfactory complete all as specified and as directed Note :- Servicing of AHU units will be carried out four times during contract period as directed.
8
-
-
... More
Supply and Fixing in replacement of complete outdoor unit 18 HP for VRV system, 420 Volt Make Daikin including testing, commissioning, necessary electric connection, brasing of copper pipes, syncronize with the old systems complete all as specified and as directed Note : (i) Gas charging will be paid separately (ii) Nitrogen with vacuum test will be done on the quoted rates only.
1
-
-
... More
Supply and Fixing in replacement of compressor 5 HP 420 Volt for outer unit of VRV System make Daikin of any capacity complete all as specified and as directed
1
-
-
... More
Supply and Fixing in replacement of compressor 6 HP 420 Volt for outer unit of VRV System of Make Daikin any capacity complete all as specified and as directed
1
-
-
... More
Supply and fixing in replacement of compressor Invertor Type 6 HP for outer master unit of VRV System of Make Daikin any capacity complete all as specified and as directed
1
-
-
... More
Supply and gas charging refrigerant gas 410A or as required for system up to required level incl connected work including pressure testing with nitrogen before filling regrigerant gas in VRV System of 12 to 18 HP make Dakin complete all as specified and as directed Note : Nitrogen test will be incuded on quoted rates only
300
-
-
... More
Supply, fixing and testing in replacement unserviceable Heat Exchanger/condensor for Out door unit of VRV System of DAIKIN/VOLTAS any capacity complete all as specified and as directed
3
-
-
... More
Material & Labour in replacement burnt Electric exhaust (Condensor) DC fan Motor of any type and size capacity from VRV outdoor unit for replacement of DC fan motor on existing location with proper fitting and testing after completion of work complete all as specified and as directed
1
-
-
... More
Supply , fixing and testing of Invertor PCB for Out door unit of VRV System of DAIKIN/VOLTAS any capacity including taking down unserviceable complete all as specified and as directed
3
-
-
... More
Supply and fixing of Mother Board / Main / Control PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
2
-
-
... More
Supply and fixing of filter PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
1
-
-
... More
Supply and fixing of Power / Over voltage PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
1
-
-
... More
Supply and fixing of Fan PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
1
-
-
... More
Supply and fixing of Expansion Valve assembly for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
2
-
-
... More
Supply and fixing in replacement of high pressure / low pressure switch for outdoor unit of VRV System incl all connected work with pressure testing of nitrogen before filling regrigerant gas in VRV System of 12 to 18 HP make Dakin complete all as specified and as directed Note : (i) Refrigerant Gas 410A will be paid separately (ii) Nitrogen testing will be included on the quoted rate only.
2
-
-
... More
Supply and fixing Return Air Sensor for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
10
-
-
... More
Supply and fixing Display Sensor for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
5
-
-
... More
Supply and fixing Drain Pump for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
6
-
-
... More
Supply and fixing of suitable Bearing for AHU of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
4
-
-
... More
Supply and fixing Expansion Valve for AHU of VRV System of any capacity including taking down unserviceable complete all as specified and as directed
2
-
-
... More
Supply and fixing in replacement of unserviceable PCB for indoor unit cassette type of VRV System with remote of any capacity complete all as specified and as directed
12
-
-
... More
Supply and fixing Connector for elctric cable/wire for VRV System of any description including taking down unserviceable complete all as specified and as directed
10
-
-
... More
Prevantive maintenance and cleaning of the following Air cooling plants filters (Pre AIR Filters and Honey comb filters) by use of liquid soap solution/detergent powder including minor replacement of defective parts of Air cooling plants- 20 Nos electrically operated installed in MH Jodhpur area complete all as specified and directed of the Engr-in-Charge for for Air cooling plant 4000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 5000 CFM, installed at MH main bldg terrace Make : CAIR (02 Nos)
12
-
-
... More
All as per items Ser No 25 but for Air cooling plant 6000 CFM, installed at MH main bldg terrace Make : CAIR (02 Nos)
12
-
-
... More
All as per items Ser No 25 but for Air cooling plant 7000 CFM, installed at MH main bldg terrace Make : CAIR (03 Nos)
18
-
-
... More
All as per items Ser No 25 but for Air cooling plant 8000 CFM, installed at MH main bldg terrace Make : CAIR (02 Nos)
12
-
-
... More
All as per items Ser No 25 but for Air cooling plant 9000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 10000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 12000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 14000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 15000 CFM, installed at MH main bldg terrace Make : CAIR (03 Nos)
18
-
-
... More
All as per items Ser No 25 but for Air cooling plant 16000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 20000 CFM, installed at MH main bldg terrace Make : CAIR (01 No)
6
-
-
... More
All as per items Ser No 25 but for Air cooling plant 28000 CFM, installed at MH Adm bldg terrace Make : Zeco (01 No)
6
-
-
... More
Supply and fixing V-belt any size ISI mark including taking down unserviceable complete all as specified and as directed Make :- fanner/goodwill/Suprime.
50
-
-
... More
Supply and fix Ball bearing set suitable for Air Cooling blower rotor shaft/motor of any description as approved for Air blower/motor of any capacity for Air cooling system unit as per existing air cooling system including taking down complete all as specified and as directed
1
-
-
... More
Supply and fix Base frame (with anti vibration pads) of any size and description as per required existing size on ground for Electric motor of Air Cooler complete all as specified and as directed Note : - Base frame should match as par existing unserviceable frame and should be fitted in proper location by matching the alingment of system with blower fan upto satisfacory condition as per directed by Engr-in-Charge
1
-
-
... More
M & L for rewinding of motor water pump set 0.5 HP capacity from foundation dismantling pump motor for servicing/ replacement of unserviceable bearing, gland bush and rewinding of motor reassembling after repair/servicing reinstall on existing location & testing complete all as specified and as directed
1
-
-
... More
M & L for rewinding of motor water pump set 1 HP capacity from foundation dismantling pump motor for servicing/ replacement of unserviceable bearing, gland bush and rewinding of motor reassembling after repair/servicing reinstall on existing location & testing complete all as specified and as directed
2
-
-
... More
S&F in replacement of monoblock pump set 1 HP capacity for Air cooling plant installed at MH Jodhpur complete all as specified and as directed
1
-
-
... More
S&F in replacement of monoblock pump set 0.5 HP capacity for Air cooling plant installed at MH Jodhpur complete all as specified and as directed
1
-
-
... More
Supply and fixing Gate Valve 20/25 mm for water control for Air Cooler unit including taking down unserviceable complete all as specified and as directed
5
-
-
... More
As per item No 31 above but for size of 50 mm
3
-
-
... More
Supply and fixing Float Valve with complete tab assembly 20 mm including taking down unserviceable complete all as specified and as directed
1
-
-
... More
Supply and fixing Float Valve with complete tab assembly 25 mm including taking down unserviceable complete all as specified and as directed
1
-
-
... More
M&L Pre Air Filter EU-4 type for fresh Air for Air Cooling Unit including taking down unserviceable complete all as specified and as directed
3
-
-
... More
M&L for filter Honey Bee Pad of size 8" thickness for air cooling system installed various location at New MH as per existing including taking down unserviceable complete all as specified and as directed
6
-
-
... More
Supply and fixing Complete Canvas Clothes (Zip arrangement) with S/S body frame of suitable size of any description as per existing complete all as specified and as directed
2
-
-
... More
Taking out old damaged AC duct insulation and supply and fixing for duct insulation with Alluminium laminated (for UV protection) with nitrle insulation of thickness 13 mm and including the following:- (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
50
-
-
... More
M&L for painting of Air cooling system inner body, scratch and remove old rusting materials with sand paper and after necessary painting will be done through one coat with red oxide and other coat with rubber based paint complete all as specified and as directed
50
-
-
... More
Excavation in trenches in loose / soft soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly complete all as specified and as directed
110.7
-
-
... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed
66.1
-
-
... More
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed
44.7
-
-
... More
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) complete all as specified and directed
2733
-
-
... More
M&L for Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed. Note : Punned thickness shall be measured and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
33.2
-
-
... More
S&F of galvanized iron pipe of 80 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
6
-
-
... More
-Ditto- all as srl item no 43 here-in-before but for galvanized iron pipe of 50 mm dia
6
-
-
... More
M&L for PCC (1:3:6) type C-2, using stone aggregate 40mm graded, with and incl necessary form work where required, fair finish to the exposed surfaces complete all as specified and as directed
1.5
-
-
... More
M&L for PCC (1:2:4) type B-2, using stone aggregate 20mm graded, with and incl necessary form work where required and fair finish to the exposed surfaces complete all as specified and as directed
0.5
-
-
... More
M&L for PCC (1:4:8) type D-2, using stone aggregate 12.5mm graded, with and incl necessary form work where required and fair finish to the exposed surfaces, complete all as specified and directed
0.6
-
-
... More
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed
990
-
-
... More
Supply, laying, testing and commissioning of LT UG cable XLPE insulated galvanized steel strip heavy duty armoured electric power cable with stranded aluminium conductor 1100 volts grade 240 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed
Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
30
-
-
... More
All as srl item no 49 here-in-before but for cable size of 150 sqmm 3.5 core.
60
-
-
... More
All as srl item no 49 here-in-before but for cable size of 120 sqmm 3.5 core.
90
-
-
... More
All as srl item no 49 here-in-before but for cable size of 95 sqmm 3.5 core.
90
-
-
... More
All as srl item no 49 here-in-before but for cable size of 70 sqmm 3.5 core.
210
-
-
... More
All as srl item no 49 here-in-before but for cable size of 50 sqmm 3.5 core.
150
-
-
... More
All as srl item no 49 here-in-before but for cable size of 35 sqmm 3.5 core.
90
-
-
... More
All as srl item no 49 here-in-before but for cable size of 25 sqmm 4 core.
90
-
-
... More
All as srl item no 49 here-in-before but for cable size of 16 sqmm 4 core.
120
-
-
... More
All as srl item no 49 here-in-before but for cable size of 16 sqmm 2 core.
60
-
-
... More
M&L for taking out faulty XLPE LT Cable of size 16 sqmm to 70 Sqmm x 3.5/4 core and repair the same with straight through Joint (Tublar sleeve version) including suitable size of line connector complete all as per directed
Note : Cost of necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location will be deemed to include in quoted rates.
2
-
-
... More
All as per item No 51 above but XLPE LT Cable of size 95 sqmm to 240 Sqmm x 3.5 core
2
-
-
... More
Labour only for taking down of old conductor of any description / size from LT Poles of any size, complete all as specified and directed
0.1
-
-
... More
S&F of Aluminium conductor, steel reinforced (ACSR) of any size, straining properly on insulators and binding on existing LT poles or new poles with and incl 02mm dia aluminium binding wire,complete all as specified and directed by Engr-in-Charge. Make of ACSR : ICC/ NICCO/ BHARAT CONDUCTORS or equivalent.
Note : The 3% for sag, joints & jumpers shall be added in measurements.
0.1
-
-
... More
M&L for Unbinding from insulators and restretching ACSR conductor of any size on LT poles with and including binding with 2mm dia aluminium binding wire to insullators, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of binding wire is deemed to be included in quoted rates. 2. The distance between two poles for one single LT conductor will be consider as one span.
5
-
-
... More
Labour only for taking down of old rusted GI wire of any description / size from LT Poles of any size, complete all as specified and directed by Engr-in-Charge.
0.1
-
-
... More
S&F of contineous GI earth wire/gaurd/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on LT poles complete all as specified and directed
0.1
-
-
... More
Labour only for taking down / dismantling of old unserviceable insulators any type and any make from cross arms / pole of any size, complete all as specified and directed.
9
-
-
... More
S&F, in replacement, pin type insulators, vitreous porcelain white, brown or green of 100 mm height and 65 mm dia, with and incl one galvanised MS spindle, two galvanised iron washers and one galvanised iron nut, suitable for 1100 volts grade, complete all as specified and directed
Make : MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS
5
-
-
... More
S&F, in replacement, shackle type insulators, vitreous porcelain white, brown or green of size 75 mm height and 90 mm dia, with and incl GI strip, two galvanised iron washers and one galvanised iron nut, suitable for 1100 volts grade complete all as specified and directed Make : MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS
2
-
-
... More
S&F, in replacement, loop type insulators, vitreous porcelain white, brown or green large size with over all dismensions 90x140mm and clearance of hole 25.5 mm complete all as specified and directed Make : Rashtriya / Jaipuria Bros / Petco
2
-
-
... More
Takingdown old unserviceable / broken PVC spacers from over head lines and supply and fixing PVC spacers with clamp and nut bolt for LT 3 Phase 4 wire lines complete all as specified and as dirrected. Note : Spacing between one spacer to another spacer should be 4 to 5 mtr approx)
120
-
-
... More
Dismantling of cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers etc complete all as specified and directed
0.1
-
-
... More
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed
0.1
-
-
... More
M&L for stay assembly complete comprising of stay bow 40 cm long, 14mm dia complete with accessories as shown in electrical plate No - 1 of SSR 2009 Part - 1 (on page 495), with and incl 20 mm dia, 1.8 mtr long galvanised stay rod with threaded ends, GI nuts, bolts , washers, thimbles with and incl 300mmx300mmx6mm stay plate, with and incl dismentling of existing damaged assembly, complete all as specified and directed.
Note : The stay clamps, stay strand wire, PCC, Loop type insulator, excavation and earth work shall be measured and paid for seperately.
1
-
-
... More
S&F in replacement of stay wire stranded of size 7/3.15mm, made of galvanised steel wire with and incl dismantling of existing damaged stay wire, complete all as specified and directed
0.1
-
-
... More
M&L for preparing old painted steel or iron surfaces of LT Panel of any size and description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush / emery paper etc, with and incl repairing/refixing of existing panel doors with hinges, by using of gas welding or fixing new panel door of same size and shape made of 2.0 mm thick steel sheel, as per site requirement, with and incl all kind of machine work i.e. cutting, bending, pressing, threading, welding, jointing etc, after disconnecting LT electric connection and apply two coat of synthetic enamel paint over one coat of red oxide primer etc and making all electric connections and testing the same, complete all as specified and directed
2
-
-
... More
Replacement of UNSV Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the GI earth strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to LT Panel / DG Sets / Voltage Stabilizer / Building all as specified or indicated including testing on complete all as specified and as directed
4
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 25 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
2
-
-
... More
M&L for Aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed
20
-
-
... More
S&F, in replacement, MCCB, 415 volts, 4 pole, 63 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
Make : Schneider / L&T / C&S / Indo Asian / Havells
2
-
-
... More
S&F, in replacement, MCCB, 415 volts, 4 pole, 100 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
Make : Schneider / L&T / C&S / Indo Asian / Havells
2
-
-
... More
S&F, in replacement, MCCB, 415 volts, 4 pole, 160 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
Make : Schneider / L&T / C&S / Indo Asian / Havells
1
-
-
... More
S&F, in replacement, MCCB, 415 volts, 4 pole, 200 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
Make : Schneider / L&T / C&S / Indo Asian / Havells
1
-
-
... More
S&F, in replacement, MCCB, 415 volts, 4 pole, 250 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
Make : Schneider / L&T / C&S / Indo Asian / Havells
1
-
-
... More
S&F of all in one LED solar street light fitting of 50 Watt capacity, 6500K including 9 mtr galvanised steel pole in built lithium ion battery, mono crystalline solar panel, charge controller with dusk down sensor complete all as specified and directed
Make : Urja Global Ltd / Omega Solar / Tata Power Solar System / Fevino / Solmitra. Note : Excavation & earth work shall be measured separately
4
-
-
... More
Supply and fixing security light termination/junction box box, weather proof, along with connector for 3 phases and MCB SP 6 Amps incl 4 aluminium strip bus bar mounted on insulator of size 200x250x150mm complete all as specified and directed
Make : Sintex / Hensel
6
-
-
... More
S&F bus bar chamber of size 900x600x600 mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed by engineer-in-charge.
1
-
-
... More
M &L for replacment of on Load Changeover switch 4 pole with advance neutral of capacity 100 A in sheet steel enclosure with handle complete including doing connections with bus bar and outgoing cables, nuts bolts washers, thimbles complete all as specified and directed.
Make : Havells/ L&T/Standard
2
-
-
... More
Taking down old unserviceable existing LT panel board and Supplying, installing, testing and commissioning of panel board of size 1x1.2x0.45 mtr, outdoor cubical type KIOSK factory made (CPRI approved) double door type on front & back side openable with locking arrangement, main panel board fabricated out of CRCA MS sheet 3.15 mm thick, 40 x 40 x 6 mm angle iron and Tee section frame, dust and vermin proof, complete with Aiuminium bus bar 4 Nos, 300 Amps capacity in horizontal position mounted on porcelain insulators, totally enclosed, chamber for protection 3 phase 440 volt with suitable size of PVC insulated copper cable control wiring duly mounted on PCC (1:2:4) foundation/platform of height 450mm with suitable size of bolts, nuts & washers. The panel board shall be powder coated with smoke gray synthetic enamel paint over a coat of red oxide zinc chrome primer complete including the followings :- INCOMING :- MCCB, 415 volt, 125 Amps, 4 pole, 25 KA - 01 No (incoming) with Digital Volt meter 0 - 500 volt - 01 Amp meter 0 - 500 Amps with in-built CT's and selector switch - 01 set with three phase indicating lamp OUTGOING:-(i) MCCB, 415 volt, 63 Amps, 4 pole, 16 KA - 03 Nos (outgoing)