Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date28 Dec 2023
Closing Date25 Jan 2024
Tender Amount₹ 20,91,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.

11

-

-

... More
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.

4.1

-

-

... More
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.

5

-

-

... More
M&L for preparation of old decorated plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint complete all as specified & as directed.

27

-

-

... More
S&F pre-stressed concrete pole 11 metre long of cross section 152mm x 152mm at the top and 152mm x 260mm at bottom, class 9, complying with requirements of IS-1678-1998 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, including taking out old unserviceable pole complete all as specified & as directed Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid for separately.

14

-

-

... More
S&F Stay assembly complete with 20mm dia, 1800mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanized clamps made out of 40mmx6mm flat iron including MS galvanized nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanized stay plate, stay bow, galvanized stay strand 7/4 mm including shackle insulator and stay clamp, with & including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, all as shown in electrical plate No 1 of MES Schedule Part-I, including taking out old unserviceable stay assembly, complete all as specified and as directed. Note : Excavation & earthwork and PCC shall be measured & paid for separately under respective items of this Schedule.

13

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.

2

-

-

... More
M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of form work (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.

4

-

-

... More
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed.

2.16

-

-

... More
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.

7

-

-

... More
Supplying and laying factory made, un-reinforced precast concrete cable cover, ISI marked, Class HV, Type 1, flat, size 300mm x 180mm x 40mm, laid as cable protection cover in trenches, complete all as specified & as directed.

600

-

-

... More
Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 95 Sqmm, 3 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, including dismantling & taking out old unserviceable HT cable, complete all as specified & as directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.

200

-

-

... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.

6

-

-

... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.

3

-

-

... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.

5

-

-

... More
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

12

-

-

... More
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

12

-

-

... More
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on HT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/ type/ capacity, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.

2

-

-

... More
S&F GI continuous earth wire or guard/cradle made to shape of 3.15mm or 4mm dia as directed including Galvanized mild steel binding wire 1.63mm dia including dismantling & taking down old existing unserviceable GI continuous earth wire, guard, cradle, etc of any size from HT poles including disconnecting from the existing system complete all as specified & as directed. Note :- Galvanized wire shall be measured & paid for under this item and clamps, eye hooks where provided shall be measured and paid for separately.

1.5

-

-

... More
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size for 33 KV/ 11 KV over head structure with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, fixed as in repairs, complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.

2

-

-

... More
S&F Switch air break, gang operated outdoor, Horizontal operated type, HT 11 KV, Triple pole, 400 Amps, 3 insulator per phase, tilting/rocking horizontal type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, fixed in repairs, complete all as specified and as directed.

3

-

-

... More
M&L for repair to existing switch air break, gang operated outdoor, vertical / horizontal mechanically operated type, HT 11 KV, Triple pole by cleaning and servicing to operating mechanism, greasing etc of all joints for smooth operation replacement of defective parts where as required to make it fully functional with smooth operations and testing complete all as specified and as directed. Note : (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the quoted rates in this schedule. (ii) Major parts where required to be replaced shall be measured and paid for separately as 'Supply Only' under relevant items of this schedule. (iii) All T&P and minor parts such as nuts, bolts, washers etc shall be arranged by the contractor and the cost thereof shall be demeed to be included in the quoted rate of this item.

12

-

-

... More
Supply only the following spares parts/items repair/replacement to switch air break under serial item No. 25.00 here-in-before complete all as specified and as directed.

-

-

-

... More
Male contact/ moving contact blade heavy duty of high conductive metal (copper) any capacity vertical / horizontal operated GOD switch 11 KV, complete all as specified and as directed.

10

-

-

... More
Female contact / fix contact jaw heavy duty of high conductive metal (copper) with all necessary fittings any capacity vertical / horizontal operated 11 KV GOD switch, complete all as specified and as directed.

10

-

-

... More
Tinned copper flexible jumper 20 Amps complete all as specified and as directed.

10

-

-

... More
Ball bearing as per existing size complete all as specified and as directed.

20

-

-

... More
Post insulator for 11000 Volts capacity complete all as specified & as directed.

10

-

-

... More
Galvanized iron tubing, 25mm bore light grade, ISI marked, including all fittings and as in operating rod of GOD switch complete all as specified & as directed.

24

-

-

... More
S&F Lightning arresters HT 11 KV 65 kilo Amp Non linear expulsion type transmission class with standard fittings confirming to IS-3070 (Part-I) 1985, fixed in repairs, complete all as specified & as directed.

4

-

-

... More
S&F Pin type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.

25

-

-

... More
S&F Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90mm x 140 mm and clearance hole 25.5 mm, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.

20

-

-

... More
S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.

12

-

-

... More
Taking out silica gel from unserviceable breather assembly of transformer of any capacity and supply & filling new Silica Gel blue in crystal complete all as specified and as directed.

5

-

-

... More
M&L for disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity 63 KVA to 315 KVA for checking the condition to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bush rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil and testing on full load after connecting the HT/LT connections complete all as specified and directed. Notes : (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item. (ii) Major parts (as required) shall be measured and paid separately under appropriate item of this Sch ‘A’. (iii) Dehydration/filtration of existing transformer oil and new transformer oil required for topping up shall be measured and paid separately under appropriate item of this Sch ‘A’. (iv) T&P and minor parts such as nuts, bolts, washer, insulating material, copper wire for delta connection shall be arranged by the contractor and the cost thereof shall deemed to be included in the unit rate quoted against this item.

10

-

-

... More
Supply only the following spares parts/items to transformers under serial item No. 32.00 here-in-before complete all as specified and as directed.

-

-

-

... More
HT bushing complete with double check nuts, washers, gasket set for transformer of capacity 63 KVA to 250 KVA complete all as specified and as directed.

5

-

-

... More
LT bushing with brass spindle complete with double check nuts, insulation washers, gasket set for transformer of capacity 100 KVA complete all as specified and as directed.

4

-

-

... More
LT bushing with brass spindle complete with double check nuts, washers, gasket set for transformer of capacity 250 KVA complete all as specified and as directed.

6

-

-

... More
LT bushing with brass spindle complete with double check nuts, washers, gasket set for transformer of capacity 315 KVA complete all as specified and as directed.

3

-

-

... More
Gasket set made of rubberised cork/neoprene material for transformer of capacity 63 KVA to 100 KVA complete all as specified and as directed.

2

-

-

... More
Gasket set made of rubberised cork/neoprene material for transformer of capacity 250 KVA to 315 KVA complete all as specified and as directed.

2

-

-

... More
Supply and filling in replacement new mineral grade transformer oil EHV type conforming to IS-335 of 1993 test requirement for corrosive sulpher of BDV not less than 60 KVA for topping up of reduced level of distribution/ power transformer due to evaporation / leakage / losses due to dehydration in transformer oil duly filtered with filtration plant to obtain high dielectric strength not less than 60 KV (gap 4mm) complete all as specified and as directed. Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor and empty barrel will be the property of the Department and same shall be deposited to the AGE E/M Store Yard. Nothing extra shall be paid on this account.

2650

-

-

... More
Dehydration & filtration of old/ existing transformer oil including topping up of transformer oil with portable filtration cum dehydration machine to improve the dielectric strength minimium 60 KV within 1 minute with 4 mm Gap at site of any installation in MFFR area of any capacity/make of transformer installed on pole mounted, indoor/outdoor type plinth mounted complete all as specified and as directed. Notes: (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) Contractor shall ensure that there shall be no wastage of transformer oil. (iii) Contractor shall ensure that conservator tank is full to its level before starting the dehydration. (iv) New Transformer Oil required for topping up shall be measured and paid for separately under relevant item of this Schedule. (v) Testing of dielectric strength of dehydrated transformer oil of each transformer shall be carried out in the presence of Engineer-in-Charge and cost thereof shall be borne by the contractor.

8500

-

-

... More
M&L for preparation of external surfaces of distribution transformer of capacity upto 100 KVA including cleaning and removing oil spots from the body and painting with one coat of synthetic enamel paint (first quality) of approved tint with gun sprayer including marking of SM/MES No. etc on transformer with synthetic enamel enamel paint (white) complete all as specified & as directed.

10

-

-

... More
M&L for preparation of external surfaces of distribution transformer of capacity 250 KVA to 315 KVA including cleaning and removing oil spots from the body and painting with one coat of synthetic enamel paint (first quality) of approved tint with gun sprayer including marking of SM/MES No. etc on transformer with synthetic enamel enamel paint (white) complete all as specified & as directed.

10

-

-

... More
M&L for disconnecting carefully existing serviceable 11 KV/433 Volts distribution transformer of capacity 100 KVA by removing overhead conductor/underground cables and earth strips etc, taking out base frame carefully from foundation before dismantling the PCC in foundation, lifting, loading, transportation to other place located if required at about 30 to 40 KM, unloading, fixing, installation, making all connections, testing and commissioning at new location to full satisfaction of Engineer-in-Charge, complete all as specified and as directed. Notes : (i) All the T&P/Vehicle required for disconnection, shifting, re-connection, loading, unloading, etc including necessary petty items like bolts, nuts etc shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted. (ii) If transformer or any connected equipment/part is lost or damaged while in the custody of the contractor, the same shall be provided / repaired by the contractor at his own cost complete to the entire satisfaction of GE.

2

-

-

... More
M&L for disconnecting carefully existing serviceable 11 KV/433 Volts distribution transformer of capacity 250 KVA by removing overhead conductor/ underground cables and earth strips etc, taking out base frame carefully from foundation before dismantling the PCC in foundation, lifting, loading, transportation to other place located if required at about 30 to 40 KM, unloading, fixing, installation, making all connections, testing and commissioning at new location to full satisfaction of Engineer-in-Charge, complete all as specified and as directed. Notes : (i) All the T&P/Vehicle required for disconnection, shifting, re-connection, loading, unloading, etc including necessary petty items like bolts, nuts etc shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted. (ii) If transformer or any connected equipment/part is lost or damaged while in the custody of the contractor, the same shall be provided / repaired by the contractor at his own cost complete to the entire satisfaction of GE.

3

-

-

... More
M&L for disconnecting existing transformer step down 11 KV/0.433 KV indoor/ outdoor type of capacity 63 KVA to 100 KVA, taking down from site of installation, opening the top cover of transformer, draining out transformer oil from the housing in suitable containers (containers to be provided by the contractor) and deposit the oil in store yard of AGE MFFR, inspecting / assessing the defective / burnt parts, core assembly, etc in the presence of Engineer-in-Charge, shifting the transformer to workshop for repair including loading, unloading, transportation etc, cleaning and making good surface including internal cleaning, removing sludge, etc and painting with one coat of zinc chromate paint to the inner side of the transformer body and one coat of synthetic enamel paint (grey) on outer body of transformer by using spray machine after cleaning & removing oil spots etc, carrying out necessary repair to transformer at workshop, re-assembling, shifting back to site, reinstalling, re-connecting, re-commissioning the transformer and testing at site on full load, complete all as specified and as directed.

2

-

-

... More
M&L for disconnecting existing transformer step down 11 KV/0.433 KV indoor/ outdoor type of capacity 160 KVA to 250 KVA, taking down from site of installation, opening the top cover of transformer, draining out transformer oil from the housing in suitable containers (containers to be provided by the contractor) and deposit the oil in store yard of AGE MFFR, inspecting / assessing the defective / burnt parts, core assembly, etc in the presence of Engineer-in-Charge, shifting the transformer to workshop for repair including loading, unloading, transportation etc, cleaning and making good surface including internal cleaning, removing sludge, etc and painting with one coat of zinc chromate paint to the inner side of the transformer body and one coat of synthetic enamel paint (grey) on outer body of transformer by using spray machine after cleaning & removing oil spots etc, carrying out necessary repair to transformer at workshop, re-assembling, shifting back to site, reinstalling, re-connecting, re-commissioning the transformer and testing at site on full load, complete all as specified and as directed.

2

-

-

... More
M&L for disconnecting existing transformer step down 11 KV/0.433 KV indoor/ outdoor type of capacity 315 KVA, taking down from site of installation, opening the top cover of transformer, draining out transformer oil from the housing in suitable containers (containers to be provided by the contractor) and deposit the oil in store yard of AGE MFFR, inspecting / assessing the defective / burnt parts, core assembly, etc in the presence of Engineer-in-Charge, shifting the transformer to workshop for repair including loading, unloading, transportation etc, cleaning and making good surface including internal cleaning, removing sludge, etc and painting with one coat of zinc chromate paint to the inner side of the transformer body and one coat of synthetic enamel paint (grey) on outer body of transformer by using spray machine after cleaning & removing oil spots etc, carrying out necessary repair to transformer at workshop, re-assembling, shifting back to site, reinstalling, re-connecting, re-commissioning the transformer and testing at site on full load, complete all as specified and as directed.

1

-

-

... More
Notes for serial item No. 40.00 to 42.00 :- (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item. (ii) HT/LT coils where required shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule. (iii) All minor parts such as nuts, bolts, washers, insulating material, copper wire for delta connection, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Testing of transformer shall be arranged by the contractor for Type Test & Routine Test which shall be carried out in the presence of Engineer-in-Charge and contractor shall submit test certificates to this effect before processing the RAR for payment.

-

-

-

... More
Supply only the following spares/items for repair/replacement to transformers under serial item No. 40.00 to 42.00 here-in-before complete all as specified and as directed :-

-

-

-

... More
HT coil made out of super enameled aluminium conductor wire of suitable gauge and size as per requirement for distribution transformer capacity 63 KVA to 315 KVA complete all as directed.

90

-

-

... More
LT coil made out of super enameled aluminium conductor wire of suitable gauge and size as per requirement for distribution transformer capacity 63 KVA to 315 KVA complete all as directed.

90

-

-

... More
LT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer capacity 63 KVA to 315 KVA complete all as directed.

130

-

-

... More
HT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer capacity 63 KVA to 315 KVA complete all as directed.

135

-

-

... More
Supply & Fixing in replacement of Oil Temperature Indicator (OTI) of 33/11 KVA 5/3.15 MVA Power transformer including necessary wiring from OTI, marsalling box to 33 KV VCB complete all as specified and as directed.

3

-

-

... More
S&F in replacement of Winding Temperature Indicator (WTI) of 33/11 KVA 5/3.15 MVA Power transformer including necessary wiring from WTI, marsalling box to 33 KV VCB complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of buchhoiz relay of 11 KVA 5/3.15 MVA Power transformer including necessary wiring from transformer to Marsalling box to 33 KV VCB complete all as specified and as directed.

1

-

-

... More
Supply and fixing in replacement of Breather assembly complete including silica gel for transformer of capacity upto 63 KVA to 160 KVA complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement of Breather assembly complete including silica gel for transformer of capacity upto 200 KVA to 250 KVA complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement of Breather assembly complete including silica gel for transformer of capacity upto 315 KVA complete all as specified and as directed.

2

-

-

... More
Disconnecting the HT 11 KV VCB/SF6 panel indoor / outdoor capacity ranging from 630 to 1600 Amp, over hauling of complete panel by taking out the trolley of the breaker, opening the total mechanism of breaker, checking contact, baffle plates and other minor parts, cleaning all accessories carefully. Minor repairs, parts/accessories, the tank, baffle plates, rotating contact, upper supports, lower supports, drive assemblies and all other spare parts, reassembled after repair/ replacement of the spare parts including calibration, testing of existing IDTM relay as per load parameter complete all as specified and directed. Notes:- (i) Repair work shall be carried out only by the authorised technician of manufacturer of VCB. (ii) Spare parts as required for replacement of existing worn out parts shall be measured and paid separately under appropriate items. (iii) Labour for replacement/fixing of the supply only items shall be deemed to be included in the unit rate quoted against this item. (iv) Make of all spare part shall be used as per existing make of manufacturer.

3

-

-

... More
Supply only 11 KV VCB Contact Plugs (upper & lower) as required Amps complete all as specified & as directed.

2

-

-

... More
Supply only Finger Contact Assembly for 11 KV VCB complete all as specified & as directed.

2

-

-

... More
Supply only Closing Spring Assembly, Spring Charging motor assembly 110/230 Volt AC/DC for 11 KV indoor/outdoor VCB complete all as specified & as directed.

1

-

-

... More
Supply only Motor Cut Off Limit Switch for 11 KV indoor/outdoor VCB complete all as specified & as directed.

2

-

-

... More
Supply only Ratcet Handle for 11 KV indoor/outdoor VCB complete all as specified & as directed.

1

-

-

... More
Supply only Auxiliary Switch for 11 KV indoor/outdoor VCB complete all as specified & as directed.

2

-

-

... More
Supply only Tripping Shaft with Springs for 11 KV indoor/outdoor VCB complete all as specified & as directed.

2

-

-

... More
Supply only TNC Switch for 11 KV indoor/outdoor VCB complete all as specified & as directed.

1

-

-

... More
Supply only Power pack with battery backup 230 Volt AC input and 24 Volt DC output for VCB complete all as specified & as directed.

2

-

-

... More
Supply only Closing coil assembly for 11 KV VCB complete all as specified & as directed.

2

-

-

... More
Supply only Tripping Coil Assembly for 11 KV VCB complete all as specified & as directed.

2

-

-

... More
Supply only digital type Ampere meter and voltmeter suitable for HT VCB including making connection with copper conductor cable of suitable size complete all as specified and as directed.

2

-

-

... More
Supply only electronic hooter and alram system for VCB square type as required at site flush mounted including making connection with copper conductor cable of suitable size complete all as specified and as directed.

1

-

-

... More
Supply only indicator lamp in different colour code LED/Neon type suitable for VCB including making connection with copper conductor cable of suitable size complete all as specified and as directed.

2

-

-

... More
Supply only multi function relays (CGI 1-1 N) complete all as specified and as directed.

2

-

-

... More
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.

15

-

-

... More
M&L for 40mm graded crushed stone aggregate, deposited, spread and leveled in layers not exc 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed.

25

-

-

... More
Tightening of existing loose stay wire of stay assembly with suitable tension including providing nuts and repair to other wire, un-winded stay wire etc, complete all as specified and as directed

40

-

-

... More
S&F Danger notice plate of 25x20cm size, 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour for HT 11000 Volts and fixed with suitable MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size, fixed in repairs, complete all as specified & as directed.

30

-

-

... More
Re-straining/ re-stringing/tightening of existing HT 11 KV over head Aluminium Conductor Steel Reinforced (ACSR) and GI earth wire of any size/ type upto permissible sag in between existing span carefully without damaging other components such as insulators etc of HT distribution system with & including repair to broken conductor where required and replacement of binding wire with new 2mm dia aluminium binding wire complete all as specified and as directed. Note :- Unit for measurement and payment for this item “RM” is comprising of 3 Nos ACSR conductors and one GI earth wire in line.

2500

-

-

... More
Cutting/ trimming/ pruning of tree branches around the HT 11 KV overhead line 3 metre clearance alround from the external conductors and removing the same from site and depositing at places within the MFFR area complete all as specified and directed. Note : Unit for measurement and payment for this item is “Each span” irrespective of number of conductors in over head line.

12

-

-

... More
M&L for painting to steel tubular HT/LT pole of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.50 metre height from top of PCC coping/ pedestal and applying two coats of aluminium paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number in letters & figures of size not less than 8cm height including preparation of old surfaces for painting complete all as specified & as directed.

30

-

-

... More
Surface dressing not exc 15cm deep in soft/loose soil and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) surrounding Transformers, LT Panels, 02 Pole structures, 04 Pole Structures, 11 KV structure etc at various sub stations / E&M installations and removing rubbish upto a distance exc 200m & not exc 250m outside the periphery of the area under clearance complete all as specified & as directed.

900

-

-

... More
Supply and fixing in replacement Temperature Gauge (ISI marked) for transformer of any capacity indoor/outdoor type complete all as specified and as directed.

10

-

-

... More
Supply and fixing On Load tapping changer switch suitable for 11/0.433 KV transformer with 7 steps tapping complete with rod and gasket suitable for transformer of capacity 25 KVA to 1000 KVA including taking out unserviceable tapping switch of any type complete all as specified and as directed.

5

-

-

... More
Supply and fixing in replacement oil drain valve suitable for 25 KVA to 500 KVA transformers of indoor/outdoor type complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repairs aluminium strip of size 50mm x 6mm thick, 15cm long, 4 Nos (three Nos in phase and one No in neutral) including drilling, bending, nuts, bolts and washers of appropriate size to transformer of LT side bushing rod complete all as specified and as directed.

10

-

-

... More
S&F in repair Earth continuity conductor fixed to pole/wall or buried in ground or any other indicated situation for loop earthing aluminium strip 25mm x 3mm complete all as specified & as directed.

10

-

-

... More
S&F in repair Earth continuity conductor fixed to pole/wall or buried in ground or any other indicated situation for loop earthing Galvanized iron strip 32mm x 6mm complete all as specified & as directed.

10

-

-

... More
M&L for preparation of old steel & iron surfaces of cross arms, bracing, supports, clamps, back plates, etc of any length, shape, size on existing HT Poles of any height and applying two coats of aluminium paint complete all as specified & as directed.

95

-

-

... More
S&F in replacement of MCCB 4 Pole 400 Amps, thermal magnetic adjustable having, breaking capacity 36 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.

4

-

-

... More
S&F in replacement of MCCB 4 Pole 630 Amps, thermal magnetic adjustable having, breaking capacity 50 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.