Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_600162_1Bid Award Id
ViewTender No
8429/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M & L for topping up/change oil for transformer of 11KV/433 Volt of different capacity of dielectric strength /repturing capacity of oil not less than 50 KV (tested at site with testing kit with 2.5 mm gap ) and test the the dielectric strength of transformer oil before and after the topping up and make oil to the required level of transformer indicator level all as specified and directed by EIC. Make: Power/Savita or as approved by GE
418
-
-
... More
(a) The transformer oil shall be ISI marked and brought at site in sealed container only.
-
-
-
... More
(b) The M & L for necessary T & P for collection of transformerr oil samples , testing kit and filteration plant.
-
-
-
... More
Supply and fix in replacement breather for transformer oil conservator tank including filled with silica gel for transformer of 400 KVA complete all as specified and as directed by engineer-in charge
3
-
-
... More
S & F in replacement oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt complete all as specified and directed by engineer-in charge
1
-
-
... More
S&F in replacement drain cock ISI marked at the bottom of the main tank of transformer after , drain out oil up to safe working level and changing of existing HT bushing with stud, seal etc all as specified and directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in replacement HT bushings of transformer 11 KV/ 433 Volts including by disconnecting existng HT connectin, drain out oil up to safe working level and chnging of existing HT bushing with stud, seal etc all as specified and as directed by Engineer-In -Charge.
3
-
-
... More
Supply and fix in replacement LT stud of suitable for 400 KVA transformer of 11/433 Volt complete all as specified and directed by Engineer-In -Charge.
3
-
-
... More
M&L for painting of transformer/stablizer of 400/300 KVA including cleaning of exposed surface with emmery paper & brush, coat of zinc chrome red oxide primer and two coat of paint complete all as specified and directed.
5
-
-
... More
M & L for Maintenance/Over hauling of HT VCB 11 KV of any Make and rating at AF station Domestic and Tropo Area Jaipur by taking shunt down with prior intimation and cleaning of HT VCB by using air blower , tightning the control circuit , Checking the all fuses , to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Note: Quoted Rate is deemed to be included the following:-
2
-
-
... More
(i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code allas specified and as directedby Engineer - In - Charge.
-
-
-
... More
(ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
-
-
-
... More
Dismantling air break gang operated switche vertical/horizontal mounted including insulators and operating mechanism and carrying to MES store complete all as specified and as directed.
1
-
-
... More
Supply and fixing air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 400 amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceble air break switch,jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated complete all as specified and as directed by the Engineer - in - Charge. Make: Jaipuria/ Atlas/Pactil
1
-
-
... More
Taking out/down u/s LT UG cable of any size from trenches/pipe/ducts/ pole complete all as specified and directed.
1200
-
-
... More
M&L for LT under ground cable having size 10 sq mm 2.0 core 1100 V grade XLPE insulated screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductors laid in pipes, trenches/ducts fixed on pole etc complete all as specified and directed.
400
-
-
... More
Description all as per Item Ser No.13.00 here-in-before but having size size 16 sq mm 4 core.
400
-
-
... More
Description all as per Item Ser No.13.00 here-in-before but having size 25 sq mm 3.5 core.
300
-
-
... More
Description all as per Item Ser No.13.00 here-in-before but having size 50 sq mm 3.5 core.
100
-
-
... More
Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in soft/loose soil complete all as specified and directed .
170.1
-
-
... More
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed .
19.25
-
-
... More
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
150.9
-
-
... More
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size. Outer dia of pipe 50 mm with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified. (Excavation and earth work shall be measured and paid separately).
1140
-
-
... More
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
135
-
-
... More
M&L for 100mm thick PCC (1:3:6) type C-2, using 40mm graded aggregates as in sub base complete all as specified and directed.
13.5
-
-
... More
Supply and spreading fine aggregate (sand) for sand cusioning to receive interlocking tile complete all as specified and directed all as specified and directed by Engineer-in-Charge.
3.38
-
-
... More
M&L for refixing machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed by Engineer-in-Charge.
90
-
-
... More
M&L machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed all as specified and directed by Engineer-in-Charge.
45
-
-
... More
Dismantling and taking down fluorescent tube light single/double of any wattage or any size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store. Location: Domestic and technical Area.
96
-
-
... More
Repair only of existing street light fitting by replacement of defective Driver of capacity 15 W to 35 Watt as per site requirement including connection upto height of 11 mtr and cleaning the glass complete all as directed for domestic and technical area.
42
-
-
... More
Repair only of existing street light fitting by replacement of defective Driver of capacity 45 W to 60 Watt as per site requirement including connection upto height of 11 mtr and cleaning the glass complete all as directed for domestic and technical area.
15
-
-
... More
Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. Make: Havells/crompton Greaves/ Wipro/Philips/Bajaj/Orient/Polycab
15
-
-
... More
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. Make: Havells/crompton Greaves/ Wipro/Philips/Bajaj/Orient/Polycab
10
-
-
... More
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. Make: Havells/crompton Greaves/ Wipro/Philips/Bajaj/Orient/Polycab
6
-
-
... More
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant with driver and lamp complete all as specified and directed.
4
-
-
... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant with driver and lamp complete all as specified and directed.
3
-
-
... More
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant with driver and lamp complete all as specified and directed.
1
-
-
... More
Dismantling and taking down MCCB of any size for repair or replacement of burnt/worn out accessories or carrying to MES store complete all as directed. Location: Domestic and technical Area
11
-
-
... More
S&F MCCB 63A, 415V, 16KA, 4 Pole complete all as specified and directed. Make: L&T/ HPL/ Legrand/C&S/ Havells
4
-
-
... More
S&F MCCB 100A, 415V, 16KA, 4 Pole complete all as specified and directed. Make: L&T/ HPL/ Legrand/C&S/ Havells
3
-
-
... More
S&F MCCB 4 Pole , 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. Make: L&T/ HPL/ Legrand/C&S/ Havells
2
-
-
... More
S&F MCCB 4 Pole , 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. Make: L&T/ HPL/ Legrand/C&S/ Havells
1
-
-
... More
S&F MCCB 4 Pole , 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed. Make: L&T/ HPL/ Legrand/C&S/ Havells
1
-
-
... More
Comprehensive maintenance of addressable fire alarm system (Make- Honeywell-Morley) with rectification of faults, PMC (Pre Maintenance Check) of all smoke detectors, Modules and accessories along with database update complete all as specified and directed. Note (i) Item includes Two PMC visit (ii) Spare parts required will be measured and paid separately.
1
-
-
... More
S&F addressable photoelectric smoke detector complete all as specified and directed. Make Morley
4
-
-
... More
S&F Heat detector complete all as specified and directed. Make Morley