Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date10 Jan 2025
Closing Soon31 Jan 2025
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CI Impeller complete with impeller key.

3

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

3

-

-

... More
Wearing ring (DE & NDE) CI

4

-

-

... More
Set of 'O' ring

3

-

-

... More
CI gland cap with eye bolt complete.

3

-

-

... More
GM gland sleeve bush.

4

-

-

... More
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 12.5 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed. Note : (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item of this Schedule. (ii) Unit rate shall be deemed to include for all minor spares/extras.

1

-

-

... More
Supply only the following spare parts for centrifugal pump set of capacity 12.5 HP against serial item No. 3.00 here-in-before as per existing make, complete all as specified & as directed. Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE.

-

-

-

... More
SS Pump shaft.

1

-

-

... More
CI Impeller complete with impeller key.

1

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

1

-

-

... More
Wearing ring (DE & NDE) CI

1

-

-

... More
Set of 'O' ring

1

-

-

... More
CI gland cap with eye bolt complete.

1

-

-

... More
GM gland sleeve bush.

1

-

-

... More
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 20 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed. Note : (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item of this Schedule. (ii) Unit rate shall be deemed to include for all minor spares/extras.

2

-

-

... More
Supply only the following spare parts for centrifugal pump set of capacity 20 HP against serial item No. 5.00 here-in-before as per existing make, complete all as specified & as directed. Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE.

-

-

-

... More
SS Pump shaft.

1

-

-

... More
CI Impeller complete with impeller key.

1

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

1

-

-

... More
Wearing ring (DE & NDE) CI

1

-

-

... More
Set of 'O' ring

1

-

-

... More
CI gland cap with eye bolt complete.

1

-

-

... More
GM gland sleeve bush.

1

-

-

... More
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 25 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed. Note : (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item of this Schedule. (ii) Unit rate shall be deemed to include for all minor spares/extras.

2

-

-

... More
Supply only the following spare parts for centrifugal pump set of capacity 25 HP against serial item No. 7.00 here-in-before as per existing make, complete all as specified & as directed. Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE.

-

-

-

... More
SS Pump shaft.

1

-

-

... More
CI Impeller complete with impeller key.

2

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

1

-

-

... More
Wearing ring (DE & NDE) CI

2

-

-

... More
Set of 'O' ring

2

-

-

... More
CI gland cap with eye bolt complete.

1

-

-

... More
GM gland sleeve bush.

1

-

-

... More
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 40 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed. Note : (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item of this Schedule. (ii) Unit rate shall be deemed to include for all minor spares/extras.

2

-

-

... More
Supply only the following spare parts for centrifugal pump set of capacity 40 HP against serial item No. 9.00 here-in-before as per existing make, complete all as specified & as directed. Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE.

-

-

-

... More
SS Pump shaft.

1

-

-

... More
CI Impeller complete with impeller key.

1

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

1

-

-

... More
Wearing ring (DE & NDE) CI

1

-

-

... More
Set of 'O' ring

1

-

-

... More
CI gland cap with eye bolt complete.

1

-

-

... More
GM gland sleeve bush.

1

-

-

... More
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 50 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed. Note : (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item of this Schedule. (ii) Unit rate shall be deemed to include for all minor spares/extras.

2

-

-

... More
Supply only the following spare parts for centrifugal pump set of capacity 50 HP against serial item No. 11.00 here-in-before as per existing make, complete all as specified & as directed. Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE.

-

-

-

... More
SS Pump shaft.

1

-

-

... More
CI Impeller complete with impeller key.

1

-

-

... More
Shaft sleeve bronze with locking screw & lock nut.

1

-

-

... More
Wearing ring (DE & NDE) CI

1

-

-

... More
Set of 'O' ring

1

-

-

... More
CI gland cap with eye bolt complete.

1

-

-

... More
GM gland sleeve bush.

1

-

-

... More
M&L for taking down defective induction motor of following capacity from the foundation, disconnecting the electric connections, coupling pully and transporting to work shop for repair, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire : CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEE

-

-

-

... More
10 HP capacity, 3 phase, 415 Volt, 50Hz

3

-

-

... More
12.5 HP capacity, 3 phase, 415 Volt, 50Hz

1

-

-

... More
20 HP capacity, 3 phase, 415 Volt, 50Hz

2

-

-

... More
25 HP capacity, 3 phase, 415 Volt, 50Hz

1

-

-

... More
40 HP capacity, 3 phase, 415 Volt, 50Hz

1

-

-

... More
50 HP capacity, 3 phase, 415 Volt, 50Hz

1

-

-

... More
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete all as specified & directed.

7

-

-

... More
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 100mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified & directed.

5

-

-

... More
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 150mm bore, complete all as specified & directed.

6

-

-

... More
Supply and fixing Non Return Valve (NRV) of size 80mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 80mm bore complete all as specified and as directed.

5

-

-

... More
Supply and fixing Non Return Valve (NRV) of size 100mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 100mm bore complete all as specified and as directed.

5

-

-

... More
Supply and fixing Non Return Valve (NRV) of size 150mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 150mm bore complete all as specified and as directed.

4

-

-

... More
S&F in replacement of high tensile mild steel screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, bolts and washers of any sizes complete all as specified & as directed.

55

-

-

... More
S&F in replacement of MS pipe 80mm bore heavy duty Class 'C' (ISI Marked) for pumping set suction line/ discharge water line including with necessary fittings sch as bend, elbow, tee, socket including cutting, threading, welding etc and replacement of wornout, MS nut, bolts, washers & sockets flange etc including complete painting with two coat of bituminous paint over a coat of zinc chrome primer complete all as specified and directed.

20

-

-

... More
S&F in replacement of MS pipe 100mm bore heavy duty Class 'C' (ISI Marked) for pumping set suction line/ discharge water line including with necessary fittings sch as bend, elbow, tee, socket including cutting, threading, welding etc and replacement of wornout, MS nut, bolts, washers & sockets flange etc including complete painting with two coat of bituminous paint over a coat of zinc chrome primer complete all as specified and directed.

20

-

-

... More
Collecting treated water sample from UG Sump of Main Pump House respectively and testing of both for Chemical and Bacteriological analysis from Govt/ NABL accredited laboratory monthly or whenever required or ordered by Engineer - in-Charge.

8

-

-

... More
M&L for Earthing complete to equipments with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15 cm thick all around bottom and top, including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with RCC (1:2:4 type B1) using 20mm graded stone aggregate cover of size 30cmx30cmx8cm thick reinforced with expanded metal weighing not less than 4kg/sqm, PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in earthing pit complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.

9

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 10 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

3

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 12.5 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

2

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 20 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

3

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 25 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

2

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 40 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

2

-

-

... More
M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 50 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed. Make : Asian paint/Burger/Nerolac

2

-

-

... More
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.

2

-

-

... More
M&L for name board with green acrylic radium sheet for pump house/ installation with suitable sheet of size 1.20 mtr x 0.90 mtr with suitable stainless steel frame work with pedestal of dimension 2.5 mtr x 1.20 mtr, 40 mm dia stainless steel rod including suitable size & shape of letters printed on both side with necessary earth work, PCC foundation etc including painting/framing work complete all as specified and directed. Note:- (i) Size and shape of letters and other things should be as per sample kept in AGE office sample room. (ii) The cost of above item deemed to be inclusive in qouted rates of this item.

4

-

-

... More
Supply & installation of Smart Integrated All in one Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500 K having capacity 20 Watt ,IP 65, 120 lumens/watt, min 12.8 Volt/ 21 AH lithium ferrous phopshate battery, 40 W (monocrystalline) 18 Volt Solar panel, LED life 50000 hours including bracket made out of suitable size of GI tubing medium grade and fixed with clamps nuts and bolts, washer, suitable length MS tubular pole medium grade with painting as per manufacturer recommendation, testing & commissioning complete including taking down old unserviceable lighting system complete all as specified and directed. Make : Bajaj Cat Part No. BSZSL 20 W LED, Surya, Orient, Crompton, Philips Note: (i) Contractor has to furnish a replacement warranty of 05 years for solar street light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.

11

-

-

... More
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.

0.3

-

-

... More
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundations of poles/struts etc. filling and mass concrete complete all as specified and as directed.

2.86

-

-

... More
M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of poles/ struts including necessary formwork as required complete all as specified and as directed.

0.32

-

-

... More
Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), indoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:-

1

-

-

... More
(Description of serial item No. 37.00 Contd….) Incoming (a) MCCB, 4 Pole, 250 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 01 No. (Incoming). (b) Bus bar electrolytic grade aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply - 01 No. (Incoing). (c) Digital Volt meter, Digital Amp meter with built in selector switch including necessary CTs (set of three) - 1 Set. (d) Neon Indicator lamps Set RYB, “LED” type (set of three) - 01 Set Outgoing (For 20 HP pump set no-01) (a) MCCB, 4 Pole, 100 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 01 Nos. (b) Star-delta starter suitable for 20 HP pump set alongwith suitable size of contactor (Main, star and delta) alongwith add on block if desired, overload relay, Single Phasing preventor and timer - 01 No. (c) Neon Indicator lamps Set RYB, “LED” type (set of three) - 01 Set (d) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box. (For 20 HP pump set no-02) (a) MCCB, 4 Pole, 100 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 02 Nos. (b) Star-delta starter suitable for 20 HP pump set alongwith suitable size of contactor (Main, star and delta) alongwith add on block if desired, overload relay, Single Phasing preventor and timer - 01 No. (c) Neon Indicator lamps Set RYB, “LED” type (set of three) - 01 Set

-

-

-

... More
(Description of serial item No. 37.00 Contd….) (d) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box. (For 10 HP pump set no-03) (a) MCCB, 4 Pole, 63 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 01 Nos (Outgoing). (b) MCB 63 Amp rating, TPN , rupturing capacity 10 kA, ‘C’ Series - 03 No (Outgoing) (c) MCB 32 Amp rating, DP, rupturing capacity 10 kA, ‘C’ Series - 03 No (Outgoing) (d) MCB 6 to 32 Amp rating, SP, rupturing capacity 10 kA, ‘C’ Series - 04 No (Outgoing) (e) On Load Changeover switch 200 Amps, 4 Pole, 415 volt, 50 Hz, sheet steel enclosure with front handle - 01 (Outgoing) (f) Star-delta starter suitable for 10 HP pump set alongwith suitable size of contactor (Main, star and delta) alongwith add on block if desired, overload relay, Single Phasing preventor and timer - 01 No. (c) Neon Indicator lamps Set RYB, “LED” type (set of three) - 01 Set (d) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.

-

-

-

... More
Notes for serial item No. 37.00 Contd :- (i) Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates. (vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box. (vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work.

-

-

-

... More
De-watering the existing RCC semi underground water reservoir of 450000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed.

3

-

-

... More
De-watering the existing RCC semi underground water reservoir of 525000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed.

1

-

-

... More
Note for serial item No. 38.00 & 39.00 Contd... :- (i) The sludge may be including water slush type of solids and the contractor shall not have any claim whatsoever on this account. (ii) The mixture of bleaching powder & water for cleaning shall be prepared by mixing 250 gm of bleaching powder in 10 litres of fresh water. (iii) All inlets/outlets/over flow/wash out connections shall be cleaned. Any leakage in joints shall be made good as directed and quoted rate also includes this aspect. (iv) The existing water, water used for cleaning etc shall be bailed out at the nearest open drain available. (v) Any damage occurred to the assets during cleaning etc shall be made good by the contractor at his own cost. (vi) All protective & safety measures for workmen against Honey Bee, insects, creatures, gases, height etc shall be responsibility of the contractor. The quoted rate shall be deemed to include for this provision. (vii) The contractor must carried out all the process in such a way that the complete inside cleaning process as mentioned above must be finished in stipulated time decided by Engineer-in-charge to produce minimum disturbance to regular water supply to connected area. If contractor fails to restore the water supply within stipulated time, as decided by Engineer-in-charge, the penal recovery of Rs - 2000.00 per day will be recovered from contractor's dues. (viii) All the equipment/material required for cleaning of tank / sump such as sludge pump/Raw water pump/DG Set with connecting cable will be brought by the contractor and no extra cost will be paid in this effect. (ix) Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc. (x) Tank to be sterilized and disinfected with the help of UV lamp for min 01 hr to make bacteria free. (xi) Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free. (xii) Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners.

-

-

-

... More
Supply and fixing in replacement of PVC insulated 3 core, 4 sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and confirming to IS:694 and connecting to submersible pump and to LT Panel complete all as specified and directed.

40

-

-

... More
Supply and fixing in replacement of PVC insulated 3 core, 6 sqmm copper multistranded PVC sheathed flexible cable ISI marked and confirming to IS:694 and connecting to pump set and to LT Panel complete all as specified and directed.

25

-

-

... More
Supply and fixing in replacement of PVC insulated 3 core, 10 sqmm copper multistranded PVC sheathed flexible cable ISI marked and confirming to IS:694 and connecting to pump set and to LT Panel complete all as specified and directed.

20

-

-

... More
M&L for taking out existing flange joint of 80mm dia & make new flange joint complete with rubber or fibre board gaskets, tightening by existing nut bolts complete with welding as desired testing for flange joints etc complete all as specified & as directed.

6

-

-

... More
M&L for taking out existing flange joint of 100mm dia & make new flange joint complete with rubber or fibre board gaskets, tightening by existing nut bolts complete with welding as desired testing for flange joints etc complete all as specified & as directed.

5

-

-

... More
M&L for painting of OH tank of capacity 20000 gallon upto 18 metre staging height with Apex paint of make Asian/Burger/Dulko including scrabbing of old paint and making smooth the surface complete all as specified and directed. Note - (i) Painting to be done on outer surface of OH Tank from ground level to dome portion including stair case. (ii) Cost of required T&P shall be included in the quotated rates.

1

-

-

... More
Supply and fixing with replacement of ladder inside the UG sump etc made out of MS channel, angle iron, flat iron of any size including drilling of holes with and including nuts, bolts and washers etc, as required, including painting with two coats of synthetic enamel paint over a coat of red oxide paint complete all as specified and directed.

200

-

-

... More
M&L for painting of Raising main, Delivery main, Over flow and wash out pipe line (Height of OHT approx 21.0m) as per colour code as directed by Engineer-in-charge including scrapping of pipe before painting and painting with two coats of synthetic enamel paint over a coat of red oxide paint and making the arrow to show the direction and writing the Raising main, Delivery main, Over flow and wash out on the pipe line complete all as specified and directed. Note : (i) The contractor must cater for all safety arrangement i. e. safety belts/ helmet / safety harness, shoes etc for working man power and inspecting staff and no extra cost will be paid in this effect. (ii) The T&P and other necessary equipment shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect.

1

-

-

... More
Supply and fixing in replacement of stainless steel wire mesh of width upto 6 feet suitable on wooden frame for pump houses including drilling of holes with and including nuts, bolts and washers etc, as required,complete all as specified and directed.

500

-

-

... More
Supply and fixing of cast iron body flow water meter size 150mm, temprature up to 50 degree centigrade and 1000 liters per pulse class B IP 68 etc and testing, including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete all as specified & directed. Notes : For all items of BoQ, all old unserviceabale valuable material from above item no 01 to 49 shall be deposited to AGE (E/M) yard.

1

-

-

... More
Notes for serial item No. 1 to 49 above :- (i) all old unserviceabale valuable material from above item no 01 to 49 shall be deposited to AGE (E/M) yard.Concerned AGE will take material in charge and entry shall be endored in ledger.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.